• 제목/요약/키워드: Dynamic Displacement Field

검색결과 223건 처리시간 0.028초

Discrete element numerical simulation of dynamic strength characteristics of expanded polystyrene particles in lightweight soil

  • Wei Zhou;Tian-shun Hou;Yan Yang;Yu-xin Niu;Ya-sheng Luo;Cheng Yang
    • Geomechanics and Engineering
    • /
    • 제34권5호
    • /
    • pp.577-595
    • /
    • 2023
  • A dynamic triaxial discrete element numerical model of lightweight soil was established using the discrete element method to study the microscopic mechanism of expanded polystyrene (EPS) particles in the soil under cyclic loading. The microscopic parameters of the discrete element model of the lightweight soil were calibrated depending on the dynamic triaxial test hysteresis curves. Based on the calibration results, the effects of the EPS particles volume ratio and amplitude on the contact force, displacement field, and velocity field of the lightweight soil under different accumulated strains were studied. The results showed that the hysteresis curves of lightweight soil exhibit nonlinearity, hysteresis, and strain accumulation. The strain accumulated in remolded soil is mainly tensile strain, and that in lightweight soil is mainly compressive strain. As the volume ratio of EPS particles increased, the contact force first increased and then decreased, and the displacement and velocity of the particles increased accordingly. With an increase in amplitude, the dynamic stress of the particle system increased, and the accumulation rate of the dynamic strain of the samples also increased. At 5% compressive strain, the contact force of the particles changed significantly and the number of particles deflected in the direction of velocity also increased considerably. These results indicated that the cemented structure of the lightweight soil began to fail at a compressive strain of 5%. Thus, a compressive strain of 5% is more reasonable than the dynamic strength failure standard of lightweight soil.

비정렬 동적격자를 이용한 블레이드-와류 간섭에 따른 공탄성 변위예측 (Prediction of Aeroelastic Displacement Under Close BVI Using Unstructured Dynamic Meshes)

  • 조규원;오우섭;권오준;이인
    • 한국항공우주학회지
    • /
    • 제30권8호
    • /
    • pp.37-45
    • /
    • 2002
  • 본 연구에서는 이차원에서 비정상 비점성 유동해석을 위한 비정렬 동적 편자 기법을 개발하였다. 유동해석 기법은 시간에 대해 2차의 정확도를 갖는 내재적인 시간적분법을 사용하였으며, 격자중심의 유한 체적법과 Roe의 풍상차분법을 이용하여 공간에 대한 차분화를 하였다. 시간과 공간에 대한 정확도를 증가시키기 위해서는 해에 따라 원하는 위치에 격자점들을 임의로 추가할 수 있는 비정상 동적 적응격자 기법을 사용하였다. 이를 이용하여 이차원의 2자유도를 갖는 스프링 에어포일 시스템의 와류와의 간섭현상에 따른 공탄성적 변위를 예측하였다.

Effects of traffic-induced vibrations on bridge-mounted overhead sign structures

  • Kim, Janghwan;Kang, Jun Won;Jung, Hieyoung;Pack, Seung-woo
    • Structural Engineering and Mechanics
    • /
    • 제55권2호
    • /
    • pp.365-377
    • /
    • 2015
  • Large-amplitude vibration of overhead sign structures can cause unfavorable psychological responses in motorists, interfere with readability of the signs, and lead to fatigue cracking in the sign structures. Field experience in Texas suggests that an overhead sign structure can vibrate excessively when supported within the span of a highway bridge instead of at a bent. This study used finite element modeling to analyze the dynamic displacement response of three hypothetical sign structures subjected to truck-passage-induced vertical oscillations recorded for the girders from four actual bridges. The modeled sign bridge structures included several span lengths based on standard design practices in Texas and were mounted on precast concrete I-girder bridges. Results revealed that resonance with bridge girder vertical vibrations can amplify the dynamic displacement of sign structures, and a specific range of frequency ratios subject to undesirable amplification was identified. Based on these findings, it is suggested that this type of sign structure be located at a bridge bent if its vertical motion frequency is within the identified range of bridge structure excitation frequencies. Several alternatives are investigated for cases where this is not possible, including increasing sign structure stiffness, reducing sign mass, and installing mechanical dampers.

자계해석을 통한 영구자석형 차단기 조작기의 동작특성 해석 (ANALYSIS OF MAGNETIC FIELD AND DYNAMIC BEHAVIOR OF THE PERMANENT MAGNETIC ACTUATOR)

  • 강종호;박상훈;배채윤;정현교
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.46-48
    • /
    • 2002
  • This paper formulates the principle of the permanent magnetic actuator (PMA) and its dynamic characteristic calculation. Some results of the calculation and analysis of the dynamic curves are presented. Due to its great advantages, PMA that presented recently drew great attention from engineers all over the world. We present the magnetic field and actuator using finite element method associated to parameter calculating the displacement of the moving parts and the supplying current when the actuator is DC voltage supplied or capacitor supplied. In this paper, We will do compare of dynamic behavior between DC voltage supplied and capacitor discharge supplied.

  • PDF

A Case Study on the Effect of Damaged Expansion Joint for Safety Assessment of Highway Bridges

  • Kim, Kwang-Il;Chai, Won-Kyu;Lee, Myeong-Gu;Son, Young-Hyun
    • International Journal of Safety
    • /
    • 제9권2호
    • /
    • pp.16-21
    • /
    • 2010
  • In this study, the variations of transformed impact factors and load carrying capacity of highway bridges measured from the state of expansion joint are evaluated. the field loading tests were performed on the highway bridge with damaged expansion joint to investigate the variation of the load carrying capacity. From the field loading tests in case that damaged expansion joint exist or do not exist, the static displacements and dynamic displacements were measured, and TIF were calculated, respectively. dynamic test is performed in order to estimate dynamic displacement and TIF according to the level of damage of expansion joint. From the results of TIF, the load carrying capacity of highway bridges with damaged expansion joint were estimated.

상시 진동을 이용한 교량 정적 처짐 산정 기술의 현장 적용성 연구 (A Study on the Field Application of the Measurement Technique for Static Displacement of Bridge Using Ambient Vibration)

  • 오상혁;문대중;이광명
    • 한국건설순환자원학회논문집
    • /
    • 제11권4호
    • /
    • pp.355-363
    • /
    • 2023
  • 노후 교량의 안전성을 평가하는 방법에 있어서 동특성과 처짐은 구조계의 강성과 직접 연관이 있으며, 처짐의 경우에는 교량 사용자가 직접 감지할 수 있는 물리량으로 가장 중요한 인자이다. 하지만 교량의 처짐을 측정하기 위해서는 교량의 하부에 처짐계를 설치하고 교통 차단 및 재하시험을 실시해야 하는 번거로움이 있어 교량의 환경에 따라서 비용이 증가하거나 측정이 불가능한 문제들이 발생하고 있다. 본 연구에서는 처짐계의 설치 없이 가속도계만을 이용하고 재하시험 없이 상시 진동을 이용하여 교량의 처짐을 측정하는 방법을 제안하였다. 상시 진동을 이용한 교량 동특성 및 처짐 분석을 위해 단순한 연산으로 빠른 분석이 가능하다고 알려진 TDD 기법을 이용하여 교량의 모드형상과 고유진동수를 추출하였으며, 유연도 분석을 통하여 교량의 단위하중 처짐을 분석하여 정적 처짐까지 산정하였다. 본 제안 기술의 검증을 위해 공용중 교량인 C대교(사장교)에 적용하여 모드형상, 고유진동수, 정적 처짐 분석을 수행하였으며 재하시험 실측값과 구조해석 자료와 비교하였다. 그 결과 모드형상 및 고유진동수는 0.42~1.13 %, 중앙경간에서의 최대 처짐은 3.58 %의 오차율을 확인하였다. 따라서 제안기술은 처짐계의 설치가 어려워 실측이 불가능한 교량의 처짐을 추정하여 설계값 및 해석값 대비 처짐 발생량 비교로 교량의 안전성을 간접적으로 파악할 수 있는 근거 자료로 활용 가능할 것으로 사료된다.

영종대교 강직결 궤도 및 종형거더 단부의 거동 분석 (Evaluation of Behavior of Direct Fixation Track and Track Girder Ends on Yeongjong Grand Bridge)

  • 최정열;정지승;김준형;이규용;이선길
    • 한국안전학회지
    • /
    • 제31권6호
    • /
    • pp.45-51
    • /
    • 2016
  • The purpose of this study is to investigate the influence of train-induced end rotation of simple supported track girder on the performance of a direct fixation track system (DFTS) in Yeongjong grand bridge. In this study, the influences of deflection of a DFTS and track girder on dynamic rail-track girder interaction forces for the track girder ends currently employed in airport express lines were assessed by performing field tests using actual vehicles running along the service lines. Therefore, the dynamic displacement of rail and track girder and the fastener stress on the center and ends sections of DFTS were measured for two different trains (AREX and KTX) running in Yeongjong grand bridge. A three-dimensional finite element analysis (FEA) model using the time-history function based on the design wheel load was used to predict the train-induced track and track girder displacement, and the FEA and field test results were compared. The analytical results reproduced the experimental results well within about 3-7% difference in the values. Therefore, the FEA model of DFTS on track girder is considered to provide sufficiently reliable FEA results in the investigation of the behavior of DFTS. Using the analytical and experimental results, the influence of train-induced end rotation of simple supported track girder on the interaction behavior of rail and track girder installed on a simple supported track girder ends, i.e., upward displacement of rail-track girder and the fastener stress, was investigated. It was found that the train-induced end rotation effect of track girder was not significantly affected by the upward displacement of rails and the fastener stresses of track girder ends. Further, the interaction behavior of rail and track girder were similar to or less than that of the general railway bridge deck ends, nevertheless the vertical displacement of track was higher than that of conventional DFTS on the general railway bridge. From the results, the dynamic responses of the DFTS on track girder ends were not significantly affected by the safety and stability of DFTS ends.

굽힘 압전 복합재료 작동기의 하중 특성 (Load Capability in a Bending Piezoelectric Composite Actuator with a Thin Sandwiched PZT Plate)

  • 우성충;구남서
    • 대한기계학회논문집A
    • /
    • 제31권8호
    • /
    • pp.880-888
    • /
    • 2007
  • This article describes the load capability of bending piezoelectric actuators with a thin sandwiched PZT plate in association with the stored elastic energy induced by an increased dome height after a curing process. The stored elastic energy within the actuators is obtained via a flexural mechanical bending test. The load capability is evaluated indirectly in terms of an actuating displacement with a load of mass at simply supported and fixed-free boundary conditions. Additionally, a free displacement under no load of mass is measured for a comparison with an actuating displacement. The results reveal that an actuator with a top layer having a high elastic modulus and a low coefficient of thermal expansion exhibits a better performance than the rest of actuators in terms of free displacement as well as actuating displacement due to the formation of the large stored elastic energy within the actuator system. When actuators are excited at AC voltage, the actuating displacement is rather higher than the free displacement for the same actuating conditions. In addition, the effect of PZT ceramic softening results in a slight reduction in the resonance frequency of each actuator as the applied electric field increases. It is thus suggested that the static and dynamic actuating characteristics of bending piezoelectric composite actuators with a thin sandwiched PZT plate should be simultaneously considered in controlling the performance.

Shock absorption of concrete liquid storage tank with different kinds of isolation measures

  • Jing, Wei;Chen, Peng;Song, Yu
    • Earthquakes and Structures
    • /
    • 제18권4호
    • /
    • pp.467-480
    • /
    • 2020
  • Concrete rectangular liquid storage tanks are widely used, but there are many cases of damage in previous earthquakes. Nonlinear fluid-structure interaction (FSI) is considered, Mooney-Rivlin material is used for rubber bearing, nonlinear contact is used for sliding bearing, numerical calculation models of no-isolation, rubber isolation, sliding isolation and hybrid isolation concrete rectangular liquid storage tanks are established; dynamic responses of different structures are compared to verify the effectiveness of isolation methods; and influences of earthquake amplitude, bidirectional earthquake and far-field long-period earthquake on dynamic responses are investigated. Results show that for liquid sloshing wave height, rubber isolation cause amplification effect, while sliding isolation and hybrid isolation have reduction effect; displacement of rubber isolation structure is much larger than that of sliding isolation with limiting-devices and hybrid isolation structure; when PGA is larger, wall cracking probability of no-isolation structure becomes larger, and probability of liquid sloshing wave height and structure displacement of rubber isolation structure exceeds the limit is also larger; under bidirectional earthquake, occurrence probabilities that liquid sloshing wave height and structure displacement of rubber isolation structure exceed the limit will be increased; besides, far-field long-period earthquake mainly influences structure displacement and liquid sloshing wave height. On the whole, control effect of sliding isolation is the best, followed by hybrid isolation, and rubber isolation is the worst.

소형무인경전철(PRT)궤도 레일이음매의 동적거동 분석 (Evaluation of Dynamic Behavior of Rail Joints on Personal Rapid Transit Track)

  • 최정열;김준형
    • 한국안전학회지
    • /
    • 제31권5호
    • /
    • pp.89-94
    • /
    • 2016
  • The objective of this study was to estimate the dynamic behavior of a personal rapid transit(PRT) track system using a rail of rectangular tube section and a rail joint of sliding type, and to compare the results with the normal rail and rail joint of a PRT track system by performing field measurements using actual vehicles running along the service lines. The measured vertical displacement of rail and sleeper, and vertical acceleration of rail for the normal rail and rail joint section were found to be similar, and the rail joint of sliding type satisfied the design specifications of the track impact factor for a conventional railway track. The experimental results showed that the overall dynamic response of the rail joint were found to be similar to or less than that of the normal rail, therefore the rail joint of sliding type for PRT track system was sufficient to ensure a stability and safety of PRT track system.