• 제목/요약/키워드: Dynamic Crack Initiation Toughness

검색결과 15건 처리시간 0.02초

SS41강 용접부의 동적균열개시인성 평가 (An Evaluation of Dynamic Crack Initiation Toughness in SS41 Steel Welding)

  • 정재강;김건호
    • Journal of Welding and Joining
    • /
    • 제12권2호
    • /
    • pp.108-118
    • /
    • 1994
  • In the present study, the dynamic crack initiation toughness and total absorbed energy behavior of Heat Affected Zone(HAZ) was experimentally evaluated for SS41 steel welding. The materials were submerged arc-welded SS41 steel plate with thickness 19mm. The test temperature range was from $20^{\circ}C$(room temperature) to $-70^{\circ}C$ The HAZ of welding were divided into three sub-zones for analysis; H1, H2, H3, according to the distance from the fushion line. From the experimental studies, the reference value of dynamic crack initiation toughness $(J_{Id(R)})$ can be use to estimate dynamic fracture toughness characteristics of steel welding.

  • PDF

유효 $K_{1d}$ 산정을 위한 샬피 충격시험편의 노치형상에 관한 연구 (An Evaluation of Notch Shpae for Estimation of Available $K_{1d}$ by Instrumented Charpy Impact Test)

  • 우창기;강동명;이하성
    • 한국자동차공학회논문집
    • /
    • 제7권6호
    • /
    • pp.135-143
    • /
    • 1999
  • This investigation evaluates effects of notch depth, fatigue precrack length and side groove in impact specimen for estimation of a valid K1d by instrumented Charpy impact test. Specimen material is 6005-T6. for notch depth 2.0mm and 2.5mm specimens or within about 2mm fatigue precrack length with notch depth 2.0mm and 2.5mm specimens or within about 2mm fatigue precrack length with notch depth 2.0mm , dynamic fracture toughness [$K_{1d,(1)}$] obtained by crack initiation load($P_m$) should be used. Dynamic fracture toughness of side grooved specimens are overestimated to that of standard impact specimen about 15 %-20%. It is confirmed that the formula of dynamic fracture toughness obtained by impact absorbed energy is inappropriate for ductile materials.

  • PDF

콤포케스팅법에 의해 제조된 알루미늄 금속복합재료의 동파괴 인성치에 관한 연구 (Experimental Investigation of the Dynamic Fracture Toughness for Aluminum Alumina Whisker Metal Matrix Composites)

  • Kim, M.S.;Lee, H.C.
    • 한국정밀공학회지
    • /
    • 제10권3호
    • /
    • pp.152-160
    • /
    • 1993
  • This paper presents experimental study of the static and dynamic fracture toughness behavior of a A1-6061 aluminum alloy reinforced alumina( .delta. -A1$_{2}$0$_{3}$) whiskers with 5%, 10%, 15% volume fraction. The static fracture tests using three-point bending specimen were performed by UTM25T. And drop weight impact tester performing dynamic fracture tests was used to measure dynamic locads applied to a fatigue-precracked specimes. The oneset of crack initiation was detected uwing a strain gage bonded near a crack tip. The value of static fracture toughness $K_{IC}$ and dynamic fracture toughness $K_{ID}$ were decided on the basis of linear elastic fracture mechanics. The effects of fiber volume fraction and loading on fracture toughness were investigated. The distribution of whiskers, bonding state and fracture interfaces involved in void, fiber pull-out state were investigated by optical microscopy(OM) and scanning electron microscopy(SEM)

  • PDF

균열정지현상에 관한 기초적 연구 (A Basic Study on the Crack Arrest Phenomena)

  • 이억섭;김상철;송정일
    • 대한기계학회논문집
    • /
    • 제14권1호
    • /
    • pp.112-118
    • /
    • 1990
  • 본 연구에서는 ASTM-E24.01.06에서 제안하고 있는 실험방법을 응용하여 균열 정지 파괴인성값을 측정하였다.즉 쐐기와 분리형 부싱(wedge and split bushing)으 로 압축하중을 가함으로 균열선 웨지하중 시편[crack line wedge loaded specimen(CL- WL시편)]에 인장력을 발생시켜서 균열정지 응력확대계수( $K_{1a}$)를 결정하였다. 그리고 균열개시 응력확대계수가 균열정지 응력확대계수에 미치는 영향들을 여러가지 재료들에 대하여 체계적으로 검토하였다.다.

매우 취성인 재료의 동적 파괴인성치 결정법 (Determination of Dynamic Fractrue Toughness for very Brittle Materials)

  • 이억섭;한유상
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1996년도 춘계학술대회 논문집
    • /
    • pp.724-728
    • /
    • 1996
  • The instrumented Charpy impact test is generally used to evaluate the dynamic fracture toughness for varying engineering materials. However, the test is known to be difficult to evaluate the dynamic fracture toughness for very brittle materials because of the small crack initiation load. To evaluate the dynamic fracture toughness of verybrittle materials, it is necessary to develop a load sensitive instrumented tup. In this study, a polymer tup, which has small Young's modulus, is used for the instrumented Charpyimpact test and a proper testing method is developed. The results show that the developed method can measure rapidly changing loads from the moment of contact between the tup and the specimen to dynamic crack initation of the very brittle materials.

  • PDF

계장화 샬피 충격시험에 의한 동적 파괴거동 해석 (Analysis of Dynamic Fracture Behavior by Using Instrumented Charpy Impact Test)

  • 이억섭;김선용;홍성경
    • 한국정밀공학회지
    • /
    • 제12권12호
    • /
    • pp.64-71
    • /
    • 1995
  • This investigation evaluates dynamic fracture characteristics of two alloy steels (STD-11 and STS-3) and a gray cast iron (GC-30). The dynamic fracture toughness of crack initiation and some of the dynamic fracturing characteristics were evaluated by using the instrumented Charpy impact testing procedures. It was found from experimental results for three kinds of materials that inertia force is directly proportional to impact velocity. The duration time of inertia force was found to be constant regardless of impact velocities in steel specimens.

  • PDF

계장화 샬피충격시험을 이용한 WC-Co 초경합금의 동적 균열개시인성치 결정 (Determination of Dynamic Crack Initiation Toughness Using Instrumented Charpy Impact Test in WC-Co Alloy)

  • 이억섭;박원구;홍성경;윤경수
    • 대한기계학회논문집
    • /
    • 제19권3호
    • /
    • pp.688-696
    • /
    • 1995
  • Cemented carbides, best known for their superior mechanical properties such as high strength, high hardness and high wear resistance, have a wide range of industrial applications including metal working tools, mining tools, and wear resistance components. The cobalt has been used as a binder in the WC-based hard composites due to its outstanding wetting and adhesion characteristics even though its expensiveness. Therefore many studies attempted to find a better substitute for cobalt as binder to decrease production costs. This investigation is a pre-step to study dynamic fracture characteristic evaluation of a WC-Co hardmetal were evaluated by using the instrumented Charpy impact testing procedures. It was found that the dynamic characteristics of used strain amplifier were very important experimental factors to extract valid dynamic fracturing data in WC-Co specimens. It was suggested by showing some experimental examples that when we wished to evaluate dynamic fracture toughness for cemented carbide composites by using the instrumented Charpy impact testing procedure, a careful attention must be given to obtain valid results.

다양한 노치 반경을 갖는 17-4PH강의 동적균열개시 특성 (Dynamic Crack Initiation of 17-4PH Casting Steel for Various Notch Radius)

  • 박성욱;김덕회;김재훈;문순일
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2003년도 제20회 춘계학술대회 논문집
    • /
    • pp.160-163
    • /
    • 2003
  • 본 논문에서는 17-4PH강의 동적파괴인성을 노치시편의 겉보기 동적파괴인성으로부터 평가하고자 한다. 0.1mm∼4mm의 다양한 노치반경을 갖는 시험편을 이용하였다. 임계노치반경 이상에서는 노치 반경이 증가할수록 겉보기 동적파괴인성도 증가하는 결과를 보인다. 노치시편을 이용하여 측정한 겉보기 동적파괴인성으로부터 동적파괴인성을 예측할 수 있다.

  • PDF

저속 충격하에서의 금속복합재료의 동적 특성 (Dynamic Behaviors of Metal Matrix Composites in Low Velocity Impact)

  • 남현욱;;;한경섭
    • Composites Research
    • /
    • 제12권1호
    • /
    • pp.68-75
    • /
    • 1999
  • 본 연구에서는 저속 충격에서 충격 속도에 따른 금속복합재료의 동적 거동을 연구하였다. 시험에 사용된 재료는 모재로 AC8A와 보강재로 알루미나($Al_2O_3$)와 탄소를 사용하였으며 용탕 주조법을 이용하여 금속복합재료를 제조하였다. 금속복합재료에는 15%의 부피분율을 가진 알루미나 예비성형체와 알루미나와 탄소를 각각 12%와 3% 사용한 혼합 에비성형체가 사용되었다. 제조된 금속복합재료는 인장 시험과 진동 시험을 통해 인장 강도와 탄성계수를 구하였으며, 저주파 여파기(low pass filter)와 계장화 충격 시험기를 이용하여 충격 속도에 따른 금속복합재료의 충격 거동을 연구하였다. 저주파 여파기를 이용함으로써 충격 속도에 관계없이 안정적인 실험치를 확보할 수 있었다. 충격 속도의 증가에 따라 모재와 금속복합재료의 충격에너지는 증가하였으나, 동적인성치는 일정한 값을 보였다. 충격 속도가 증가할수록 충격에너지 중 균열전파에너지의 향상이 두드러졌으며, 재료의 변형량이 증가하였다. 충격에너지 중 균열개시에너지와 동적파괴인성치의 관계를 설명하기 위하여 변형율 에너지와 노치에서의 응력 분포를 이용하여 간단한 모델을 제시하였으며, 이로부터 균열개시에너지는 동적 파괴 인성치의 자승에 비례하고 탄성계수에 반비례하는 것을 보였다.

  • PDF

計裝化 샬피 시험법 에 의한 알루미늄 합금 용접부 의 동적파괴 인성 (The dynamic fracture toughness of aluminum alloy weld zone by instrumented charpy test)

  • 문경철;강락원;이준희
    • Journal of Welding and Joining
    • /
    • 제3권2호
    • /
    • pp.42-51
    • /
    • 1985
  • The dynamic fracture toughness, fracture characteristics, impact tension and tensile properties of Al-Mg-Si T5 alloy and Al-Zn-Mg T6 alloy respectively welded with filler metal of Alcan 4043 were investigated. The dynamic fracture toughness values were obtained rapidly and simply for the specimen of small size by using instrumented Chirpy impact testing machine. the testing temperatures of the specimen were a range of room temperature and-196.deg. C. The results obtained in this experiment are summarized as follows. With decreasing the testing temperatures, dynamic tensile stress and fracture load were increased, on the other hand the deflection and impact value showed decreasing tendency in order of base metal>HAZ>weld. Changes of total absorbed energy were more influenced by the crack propagation energy than the crack initiation energy. At the low temperatures, the unstable rapid fracture representing the crack propagation appeared for the specimens of Charpy press side notched in Al-Zn-Mg alloy, but it was difficult to obtain the unstable rapid fracture in Al-Mg-Si alloy. Because of the development of plastic zone at the notch root, it was difficult to obtain thevalid $K_{1d}$ value in Al-Mg-Si alloy. Therefore the fatigue cracked specimens were effective in both Al-Mg-Si and Al-Zn-Mg alloys. With decreasing the impact testing temperatures, specimens underwent a transition from dimple-type transgranular fracture to lamella surface-type intergranular fracture because of the precipitate at the grain boundaries, impurities and crystal structure of the precipitates.s.

  • PDF