• Title/Summary/Keyword: Duty Rate

Search Result 367, Processing Time 0.029 seconds

Design of CMOS Optical Link Receiver for FTTH (FTTH용 CMOS Optical Link Receiver의 설계)

  • Kim Kyu-Chull
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.1
    • /
    • pp.47-52
    • /
    • 2004
  • This paper presents a CMOS optical receiver design featuring wide input dynamic range and low bit error rate suitable for FTTH application. We achieved 60dB input dynamic range for up to 100Mbps by controlling the PMOS feedback resistance of transimpedance preamplifier according to its output signal level. Auto-bias circuit is designed in current mirror configuration to minimize duty error. Circuit simulation has been performed using 2-poly, 3-metal, 0.6um CMOS process parameters. The designed receiver consumes less than 130mW at 100Mbps with 5V power supply.

A Numerical Study on the Thermopneumatic and Flow Characteristics of Diffuser-Nozzle Based Thermopneumatic Micropumps (디퓨져와 노즐을 이용한 열공압형 마이크로 펌프의 열공압 및 유동특성에 관한 수치해석적 연구)

  • Jeong Jin;Kim Chang Nyung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.7
    • /
    • pp.642-648
    • /
    • 2005
  • This study has been conducted to investigate the thermopneumatic and flow characteristics of diffuser/nozzle based thermopneumatic micropumps. In this study, a transient three-dimensional numerical analysis using FSI (Fluid-Structure Interaction) model has been employed to analyze the effects of the interaction between the membrane and two fluids (air and water) in the thermopneumtic micropump. The transient temperature and pressure in the cavity, the transient displacements of the membrane and the net flow rate of the micropump have been closely calculated for the frequency of 1 Hz. It has been found that the difference of the flow rates at the inlet and outlet is larger in the cooling period than in the heating period and that the duty ratio is very important in association with pump performance because the temperature in the cavity ascends drastically in the heating period and descends slowly in the cooling period. This study can be regarded as fundamental understandings for the design and analysis of thermopneumatic micropumps.

Work Types and Work Postures of the Workers in an Automobile Industry (자동차 제조업 근로자들의 작업유형과 작업자세)

  • Kim, Soon-Lae
    • Korean Journal of Occupational Health Nursing
    • /
    • v.7 no.2
    • /
    • pp.130-135
    • /
    • 1998
  • To investigate the working characteristics of the workers by place of duty, a study was carried out among 591 male workers aged 20-55 employed in an automobile industry in Korea. Workers participated to this study were divided into low back pain(LBP) and control group, according to the self-reports by written questionnaires. Work factors and complaint rates of low back pain were compared to the work places. The results were as follows ; 1) The complaint rates of low back pain were 49.2%(292 men) as a whole, 58.6%(34 men) in Production Control Department I, 50.2%(120 men) in Stamping Tool Department, 46.9%(138 men) in Bus Department. 2) Lifting and earring work of individual workers were directly associated with low back pain. Frequency of lifting and carring work is higher in the Final Body Section(Production Dept. I) and Body I Section(Bus Dept.). 3) LBP group were more frequently involved in working in awkward position(Quality Control Section of Stamping Tool Dept.), bending(Body I Section of Bus Dept.) and twisting posture(Sash Section and Body I Section of Bus Dept.). 4 )Workers exposed to vibration during working shows the higher complaint rate of low back pain.

  • PDF

The Effect of the Embedded WGV on the Engine Performance for a 2-liter Turbo-charged Gasoline Engine (2 리터급 터보과급 가솔린 기관에서 내장형 WGV가 기관 성능에 미치는 영향)

  • Jang, Jongkwan
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.24 no.2
    • /
    • pp.232-241
    • /
    • 2016
  • The turbocharger, to decrease the harmful exhaust gas(CO, HC and etc.) and $CO_2$ emission as well as the increase of the engine output, would be an useful method for engine downsizing. Therefore the thermal endurance of turbine blade, the lubrication of turbine shaft and the engine knock according to the supercharge of the inlet air, had been studied. And there had been much progress in these research tasks to be achieved a breakthrough. But a study on the built-in WGV of a gasoline engine for a passenger car which may effect on the engine performance, is few. In this paper, the effect of the embedded WGV on the engine performance was performed through the endurance test, which was conducted more than 300 hrs using the 4 stroke, 1998 cc, water-cooled engine. To sum up the major results, there were an abrasion in the area of the WGV head edge and the thermal deformation on the WGV head face, These phenomena led to reducing the boost pressure which caused the reduction in the volumetric efficiency of the engine. It resulted in decreasing the engine power gradually during the life cycle of the embedded WGV.

Effect of Flashing Light on Oxygen Production Rates in High-Density Algal Cultures

  • Park, Kyong-Hee;Kim, Dong-Il;Lee, Choul-Gyun
    • Journal of Microbiology and Biotechnology
    • /
    • v.10 no.6
    • /
    • pp.817-822
    • /
    • 2000
  • A proper flashing light is expected to enhance microalgal biomass productivity and photosynthetic efficiency. The effect of flashing light on high-density Chlorella kessleri (UTEX 398) cultures was studied using light-emitting diodes. A frequency modulator was designed to flash LEDs, and the device successfully provided wide range of frequencies and various duty cycles of flashing. A relatively high frequencies of 10, 20 and 50 kHz were used in this study. These frequencies have very short flashing time ($2-50{\mu}s$), which corresponded to the time constant of the light reaction of photosynthesis. The specific oxygen production rates of photosynthesis under flashing light were compared with those under an equivalent continuous light in specially designed illumination cuvette. The specific oxygen production rates under flashing light were 5-25% higher than those under the continuous light. A range of cell concentration was discovered, where the benefit of flashing light was maximized. The photosynthetic efficiency was also higher under flashing light with frequencies of over 1 kHz, which was a clear indication of flashing light effect and the degree of mutual shading could by overcome by flashing lights, particularly at high-density algal cultures.

  • PDF

Pump Performance Analyses with High Viscous Fluids (점성이 높은 유체를 사용하는 펌프의 성능해석)

  • Kim, Dong-Joo;Roh, Hyung-Woon;Suh, Sang-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.7 no.2 s.23
    • /
    • pp.21-26
    • /
    • 2004
  • In this study the effects of fluid viscosity on the pump performances for a conventional centrifugal pump were experimentally investigated. The study aimed to compare the pump characteristics between water and viscosity fluids. In order to measure the flow rate and pressure, v-notch welt and bourdon pressure gauges were used for the codes of KS B6301 and KS B6302. The working fluids were water, aqueous sugar and glycerin solutions. The results were summarized as follows : The experimental results were summarized as follows : the pump characteristics of the total head, shaft power, and efficiency with high viscosity fluids were different from those of water. When the viscosity of the applied fluid was increased, the total head and efficiency were more decreased than those of water. The decreasing gradients of the total head and the efficiency were larger than water due to the increased disk friction losses at the duty operation point. However, the shut-off head was almost constant regardless the viscosity of applied fluids. Each efficiency curves for the sugar $20w\%$ and glycerin $20w\%$ solutions was decreased up to $15.1\%$ and $34.4\%$ than that of water, respectively.

Battery Cell Balancing with Hybrid Architecture of Serial and Parallel Charging (직·병렬 하이브리드 충전 구조를 사용한 배터리 균형 충전)

  • Jeong, Euihan;Yang, Changju;Han, Seungho;Kim, Hyongsuk
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.2 no.4
    • /
    • pp.609-613
    • /
    • 2016
  • A hybrid charging method with serial and parallel architecture has been developed to resolve the unbalanced charge problem among battery cells for Electric Vehicles. In this method, the major charging is performed with serial part and the balancing is carried out with the parallel part, where the serial part is big and heavy but the parallel part is smaller and lighter than serial part. A sensor array to detect the individual battery cell voltage, duty rate control incorporated IGBTs, and battery management system are employed as the core parts of the proposed system.

Character of Induction Heating ZCS PWM SEPP High Frequency Inverter (유도가열용 ZCS PWM SEPP 고주파 인버터의 특성)

  • Mun, Sang-Pil;Kim, Chil-Ryong;Kwak, Dong-Kurl;Kim, Choon-Sam;Nakaoka, Mutsuo
    • Proceedings of the KIPE Conference
    • /
    • 2007.11a
    • /
    • pp.133-135
    • /
    • 2007
  • This research presented the new zero-current switching pulse width modulation SEPP(Single Ended Push-Pull)high frequency inverter for solving the problem of the zero-current SEPP high frequency inverter circuit which is using widely in the practical application of an induction heating apparatus, the soft switching operation and power control are impossible when the lowest power supply in the zero-current switching pulse width modulation SEPP high frequency inverter. The inverter circuit which is attempted by on-off operation of a switch has the reduction effect of the power loss due to a soft switching and a high frequency switching. And it confirmed that the power regulation is possible continuously from 0.25[kW] until 2.84[kW] in the case the duty rate(D) changes from 0.08 to 0.3 under zero-current switching operating by a dissymmetry pulse width modulating control and the power conversion efficiency comes true the efficiency of 95[%]. Due to the result above, the ZCS PWM SEPP high frequency inverter will be effective as sources of an induction heating apparatus.

  • PDF

Study on the development of small-scale hydrogen production unit using steam reforming of natural gas (천연가스 개질 방식 중소형 고순도 수소제조 장치 개발 연구)

  • Seo, Dong-Joo;Chue, Kuck-Tack;Jung, Un-Ho;Park, Sang-Ho;Yoon, Wang-Lai
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.720-722
    • /
    • 2009
  • This work is mainly focused at developing the hydrogen production unit with the capacity of 20 $Nm^3/h$ of high purity hydrogen. At present steam reforming of natural gas is the preferable method to produce hydrogen at the point of production cost. The developed hydrogen production unit composed of natural gas reformer and pressure swing adsorption system. To improve the thermal efficiency of steam reforming reactor, the internal heat recuperating structure was adopted. The heat contained in reformed gas which comes out of the catalytic beds recovered by reaction feed stream. These features of design reduce the fuel consumption into burner and the heat duty of external heat exchangers, such as feed pre-heater and steam generator. The production rate of natural gas reformer was 41.7 $Nm^3/h$ as a dryreformate basis. The composition of PSA feed gas was $H_2$ 78.26%, $CO_2$ 18.49%, CO 1.43% and $CH_4$ 1.85%. The integrated production unit can produce 21.1 $Nm^3/h$ of high-purity hydrogen (99.997%). The hydrogen production efficiency of the developed unit was more than 58% as an LHV basis.

  • PDF

Soft Switching High Frequency Inverter for New Induction Heating (새로운 유도가열용 소프트 스위칭 고주파 인버터)

  • Kim, C.Y.;Mun, S.P.;Kim, M.Y.;Kim, H.J.;Lyu, J.Y.;Kim, S.W.
    • Proceedings of the KIEE Conference
    • /
    • 2007.11c
    • /
    • pp.119-124
    • /
    • 2007
  • This research presented the new zero-current switching pulse width modulation SEPP(Single Ended Push-Pull)high frequency inverter for solving the problem of the zero-current SEPP high frequency inverter circuit which is using widely in the practical application of an induction heating apparatus, the soft switching operation and power control are impossible when the lowest power supply in the zero-current switching pulse width modulation SEPP high frequency inverter. The inverter circuit which is attempted by on-off operation of a switch has the reduction effect of the power loss due to a soft switching and a high frequency switching. And it confirmed that the power regulation is possible continuously from 0.25[kW] until 2.84[kW] in the case the duty rate(D) changes from 0.08 to 0.3 under zero-current switching operating by a dissymmetry pulse width modulating control and the power conversion efficiency comes true the efficiency of 95[%]. Due to the result above, the ZCS PWM SEPP high frequency inverter will be effective as sources of an induction heating apparatus.

  • PDF