• 제목/요약/키워드: Dust surface

Search Result 389, Processing Time 0.029 seconds

Monitoring of Particulate Matter Concentration for Forage Crop Cultivation during Winter Season in Saemangeum (새만금 내 동계 사료작물 재배에 따른 미세먼지 농도 변화 모니터링)

  • Lee, Seong-Won;Kang, Bang-Hun;Seo, Il-Hwan
    • Journal of Bio-Environment Control
    • /
    • v.31 no.2
    • /
    • pp.114-124
    • /
    • 2022
  • The Saemangeum has a dry surface characteristic with a low moisture content ratio due to the saline and silt soil, so the vegetation cover is low compared to other areas. In areas with low vegetation cover, wind erosion has a high probability of scattering dust. If the vegetation cover is increased by cultivating crops that can withstand the Saemangeum reclaimed environment, scattering dust can be reduced by reducing the flow rate at the bottom. Thus, the purpose of this study is to analyze the effect of suppressing the generation of fine dust and scattering dust by cultivating winter forage crops on the Saemangeum reclaimed land. While growing 0.5 ha of barley and 0.5 ha of triticale in Saemangeum reclaimed land, the concentration of fine dust was monitored according to agricultural work and growth stage. Changes in the concentrations of PM-10, PM-2.5, and PM-1.0 were monitored on the leeward, the windward and centering on the crop field. As a result of monitoring, PM-1.0 had little effect on crop cultivation. the concentration of PM-10 and PM-2.5 increased according to tillage and harvesting, and tillage had a higher increasing the concentration of PM-10 and PM-2.5 than that of harvesting. According to the growth stage of crops, the effect of suppressing scattering dust was shown, and the effect of suppressing scattering dust was higher in the heading stage than in the seedling stage. So, it was found that there was an effect of suppressing scattering dust other than the effect of land covering. Through this study, it was possible to know about the generation and suppression effect of scattering dust according to crop cultivation.

The Characteristics Asian Dust Observed in Japan Deflecting the Korean Peninsula (2010. 5. 22.-5. 25.) (한반도를 돌아 일본에서 관측된 황사의 특징 (2010년 5월 22일-5월 25일))

  • Ahn, Bo-Young;Chun, Young-Sin
    • Journal of the Korean earth science society
    • /
    • v.32 no.4
    • /
    • pp.388-401
    • /
    • 2011
  • Asian dust was observed a total of 66 times in the springtime during the period from 2002 to 2010, with 26 cases in March, 23 cases in April and 17 cases in May. This study investigates a Asian dust episode that occurred during the period from 22 to 25 May 2010, based on synoptic weather patterns, wind vector at 850 hPa, relative humidity at 1000 hPa, Jet streams and wind vector at 300 hPa, PM10 concentration in Korea and satellite imagery. In this case, Asian dust originated on 22 May along the rear of a developing low pressure system in Mongolia. The Asian dust was then transported southeastward and bypassed the Korea peninsula from 23 to 24 May, before reaching Japan on 25 May. Jet streams on 24 May bypassed the Korean peninsula and induced the development of a surface low pressure centered over the peninsula. The resulting air flow was critical to the trajectory of the Asian dust, which likewise bypassed the Korean peninsula. 72-hour backward trajectory data reveal that the Shandong Peninsula and the East China Sea were the points of origin for the air flows that swept through the Japanese sites where Asian dust was observable to the naked eay. The Asian dust pathway is ascertained by horizontal distribution of the Asian dust of RGB imagery from MODIS satellites which captured the Asian dust moving over the Shandong Peninsula, the East China Sea, and northwest of the Kyushu region in Japan. Since the synoptic pattern and the transport way of the Asian dust case are far from typical ones, which Asian dust forecasting technique has long been based on, this study can be good example of exceptional Asian dust pattern and it will be used for more accurate Asian dust forecasting.

Binary Forecast of Asian Dust Days over South Korea in the Winter Season (남한지역 겨울철 황사출현일수에 대한 범주 예측모형 개발)

  • Sohn, Keon-Tae;Lee, Hyo-Jin;Kim, Seung-Bum
    • The Korean Journal of Applied Statistics
    • /
    • v.24 no.3
    • /
    • pp.535-546
    • /
    • 2011
  • This study develops statistical models for the binary forecast of Asian dust days over South Korea in the winter season. For this study, we used three kinds of data; the rst one is the observed Asian dust days for a period of 31 years (1980 to 2010) as target values, the second one is four meteorological factors(near surface temperature, precipitation, snowfall, ground wind speed) in the source regions of Asian dust based on the NCEP reanalysis data and the third one is the large-scale climate indices. Four kinds of statistical models(multiple regression models, logistic regression models, decision trees, and support vector machines) are applied and compared based on skill scores(hit rate, probability of detection and false alarm rate).

Structural analysis and design proposal of fine dust mask with nanofiber filter fabricated using electrospinning (전기방사 나노섬유 필터를 활용한 미세먼지 마스크의 구조 분석 및 디자인 제안)

  • Han, Sang Yun
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.27 no.4
    • /
    • pp.191-195
    • /
    • 2017
  • The microstructures of nonwoven fabric with and without nanofibers used as a filter for air purification type mask were investigated using scanning electron microscope. Moreover, we proposed a new mask design which is effective in the improvement of the fine dust blocking property. When comparing to nonwoven fabrics of which an average diameter was $25{\mu}m$, the nanofibers formed by the electrospinning process had a tight mesh structure arranged irregularly with a relatively large specific surface area, which could be associated with their much smaller diameter ranging from 25 to 120 nm. Such a prominent structural feature at nanofibers led to mechanical adsorption of fine particles, resulting in enhancement of filtering behavior maintaining high permeability. In addition to the excellent performance of the mask filter, wearing the mask properly is expected to maximize the blocking property of fine dust. To meet such a requirement, a new mask design that can be closely attached to the face in order to effectively block fine dust entering the gap between the face and the mask.

Dust collection optimization of tunnel cleaning vehicle with cyclone-based prefilter (사이클론 전처리부를 지닌 터널집진차량의 집진효율 최적화)

  • Jeong, Wootae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.3
    • /
    • pp.679-686
    • /
    • 2018
  • A new dust cleaning vehicle is needed to remove fine and ultra-fine particulate matter in subway tunnels. Therefore, the recently developed tunnel cleaning vehicle is equipped with an efficient suction system and cyclone-based prefilter to handle ultra-fine particles. To treat various sizes of particulate matter with an underbody suction system, this paper proposes a cyclone-based prefilter in the suction system and validates the dust removal efficiency through Computational Fluid Dynamics (CFD) analysis using ANSYS FLUENT. Using the created surface and volume mesh, various particle sizes, materials, and fan flow rates, the particles were tracked in the flow with a discrete phase model. As a result, the dust cleaning vehicle at a normal operational speed of 5km/h requires at least a fan flow rate of $1500m^3/min$ and 100mm of suction inlet height from the tunnel track floor. Those suction modules and cyclone-based prefilters in the dust cleaning vehicle reduces the dust accumulation load of the electric precipitator and helps remove the accumulated fine and ultra-fine dust in the subway tunnel.

Analysis of Vertical Profiles and Optical Characteristics of the Asian Dust Using Ground-based Measurements (지상관측장비를 이용하여 관측한 봄철 황사의 연직분포와 광학적 특성 분석)

  • Lee, Byung-Il;Yoon, Soon-Chang;Kim, Yoonjae
    • Atmosphere
    • /
    • v.18 no.4
    • /
    • pp.287-297
    • /
    • 2008
  • The vertical profiles and optical properties of Asian dust are investigated using ground-based measurements from 1998 to 2002. Vertical profiles of aerosol extinction coefficient are evaluated using MPL (Micro Pulse Lidar) data. Optical parameters such as aerosol optical thickness ($\tau$), ${\AA}ngstr\ddot{o}m$ exponent ($\alpha$), single scattering albedo ($\omega$), refractive index, and volume size distribution are analyzed with sun/sky radiometer data for the same period. We can separate aerosol vertical profiles into three categories. First category named as 'Asian dust case', which aerosol extinction coefficient is larger than $0.15km^{-1}$ and dust layer exists from surface up to 3-4km. Second category named as 'Elevated aerosol case', which aerosol layer exists between 2 and 6km with 1-2.5km thickness, and extinction coefficient is smaller than $0.15km^{-1}$. Third category named as 'Clear sky case', which aerosol extinction coefficient appears smaller than $0.15km^{-1}$. and shows that diurnal variation of background aerosol in urban area. While optical parameters for first category indicate that $\tau$ and $\alpha$ are $0.63{\pm}0.14$, $0.48{\pm}0.19$, respectively. Also, aerosol volume concentration is increased for range of 1 and $4{\mu}m$, in coarse mode. Optical parameters for second category can be separated into two different types. Optical properties of first type are very close to Asian dust cases. Also, dust reports of source region and backward trajectory analyses assure that these type is much related with Asian dust event. However, optical properties of the other type are similar to those of urban aerosol. For clear sky case, $\tau$ is relatively smaller and $\alpha$ is larger compare with other cases. Each case shows distinct characteristics in aerosol optical parameters.

Fabrication of Large-Area Photovoltaic Crystal with Modified Surface Using Trimethoxysilyl Propyl Methacrylate (TMSPM) for Solar Cell Protection

  • Kang, Kwang-Sun
    • Current Photovoltaic Research
    • /
    • v.2 no.3
    • /
    • pp.84-87
    • /
    • 2014
  • Protection of solar cell surface is important to prevent from dust, pollen, sand, etc. Therefore, development of large area antifouling film is urgent for high performance of solar cells. The surface of silica spheres was modified to fabricate large area antifouling film. The surface of monodisperse silica spheres has been modified with 3-(trimethoxysilyl) propylmethacrylate (TMSPM) to fabricate large area photonic crystal. Although the surface modification of silica spheres with TMSPM has been failed for the base catalyst, the second trial using acid catalyst showed the following results. The FTIR absorption peak at $1721cm^{-1}$ representing C=O stretching vibration indicates that the TMSPM was attached on the surface of silica spheres. The methanol solution comprised of the surface modified silica spheres (average diameter of 380 nm) and a photoinitiator was poured in the patterned silicon wafer with the dimension of 10 cm x 10 cm and irradiated UV-light during the self-assembly process. The result showed large area crack and defect free nanostructures.

Atmospheric Aerosol Optical Properties in the Korean Peninsula

  • Oh, Sung-Nam;Sohn, Byung-Ju;Chung, Hyo-Sang;Park, Ki-Jun;Park, Sang-Soon;Hyun, Myung-Suk
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.05b
    • /
    • pp.423-423
    • /
    • 2003
  • The radiative properties of atmospheric aerosol are determined by the mass and chemical characteristics, and optical properties such as aerosol optical depth (AOD), ngstr m parameter ( $\alpha$) and single scattering albedo (SSA). In particular these aerosol optical properties also determine surface temperature perturbation that may give some information in understanding the regional atmospheric radiative forcing. For understanding the radiative forcing and regional surce of aerosol, this paper summarizes and compares the aerosol optical properties results from and compares the atmospheric aerosol optical properties results from two different experiments: Anmyeon 2000 and Jeju 2001. Korea Global Atmosphere Watch Observatory (KGAWO) at Anmyeon island and ACE-Asia super-site at Gosan Jeju island have measured the radiations and aerosols since the year of 2000. The sites are located in the mid-west and south of Korea peninsula where it is strongly affected by the Asian dust coming from China region in every spring. Aerosol optical properties over both sites were measured through the ground-based sun and sky radiometers were analyzed for understanding the radiation and climate properties. Number concentration and chemical components of aerosol were additionally analyzed for the source estimation in the transportation. The frequency distributions of aerosol optical depth are rather narrow with a modal vaiue of 0.38 at both sites. However, the distributions of show one peak (1.13) at Jeju but two peaks (0.63 and 1.13) at Anmyeon. In the cases of Anmyeon, one peak around 0.63 corresponds to relatively dust-free cases, and the second peak around 1.13 characterizes the situation when Asian dust is presented. The correlation between AOD and resulted high correlation on the wide range with high values of optical depth at Anmyeon, otherwise a narrow range of with moderate to low AOD at Jeju. In dust free condition SSA decrease with waveleneth while in the presence of Asian dust SSA either stays neutral or increases slightly with wavelength. The change of surface temperature shows the stronger positive correlations with aerosol optical depth increase at Anmyeon than Jeju. In the chemical properties the aerosol are related to high concentrations in inorganic matters, SO$^4$, NO$_3$, CA2+ in fine and coarse.

  • PDF

A Basic Study on the Continuous Purification of Zinc Chloride Plating Solution (전기아연도금조업에서 연화아합도금용술의 연질쟁액에 관한 공기연구)

  • 이선우;도만형
    • Journal of the Korean institute of surface engineering
    • /
    • v.25 no.3
    • /
    • pp.117-125
    • /
    • 1992
  • In the electrolysis process of zinc plating impurity ions must be removed from zinc chloride plating solution because it's harmful to the current efficiency and the purity of zinc plating. In this study using zinc ball as a prcipitant instead of zinc dust, the fundamental data for continuous cementation process was studied. Based upon two series of experiments that consist of batch experiment with cylindrical zinc specimen and continuous experiment with zinc balls, following results have been obtained. In the continuous experiment all impurity ions have been removed within 1 hour regardless of various experimental conditions.

  • PDF