• 제목/요약/키워드: Dust reduction

검색결과 278건 처리시간 0.031초

급·만성 기관지염과 알레르기성 비염의 국내 의료 이용 현황 분석 (Analysis of Korean Medical status of Acute Bronchitis, Chronic Bronchitis and Allergic Rhinitis patients)

  • 정유진;양웅모
    • 대한한의학회지
    • /
    • 제40권3호
    • /
    • pp.87-98
    • /
    • 2019
  • Objectives: Patients with respiratory diseases are increasing as air pollution due to fine dust gets worse. Diseases that occupy a large proportion of respiratory diseases in medical institutions are acute bronchitis, chronic bronchitis and Allergic rhinitis. The number of patients with all three diseases is gradually increasing. This study was to suggest assignment of medicine policy for improving accessibility to Korean medical treatment of respiratory diseases analyzing the current treatment status of acute bronchitis, Chronic bronchitis and Allergic rhinitis patients in Western medical and Korean medical institutes in this situation. Methods: This study used 2017 National patient sample data from the Korean Health Insurance Review and Assessment Service for research. Acute bronchitis, Chronic bronchitis, Allergic rhinitis was according to KCD code. This research contains Socio-demographic analysis classified by sex and age, the number of three disease's patients. Also the number of medical treatment, the expense of recuperation cost, medical practices were analyzed compare with Western and Korean medicine. Results: The incidence of three diseases is higher among female than male. There are many patients under the age of 10 in the case of acute bronchitis and allergic rhinitis, while there are many patients over 50 years of age in chronic bronchitis. Western medical treatment take up a larger proportion than Korean medical treatment in part of the number of three disease's patients, the number of medical treatment, the expense of recuperation cost. Conclusions: Much more patients of these diseases visit in Western medical clinic and hospital than Korean medical clinic and hospital for treatment. There are many parts of Korean medical treatment that are not covered by Health insurance benefits like herbal decoction, pharmacopuncture, etc. Korean medicine need to do the efforts for expanding medical field in variety. Also it is demanded for institutional support for reduction of the cost burden and improving on accessibility of Korean medical treatment in order to treat with the increase in respiratory diseases due to fine dust.

Evaluation of ammonia (NH3) emissions from soil amended with rice hull biochar

  • Park, Seong-Yong;Choi, Ha-Yeon;Kang, Yun-Gu;Park, Seong-Jin;Luyima, Deogratius;Lee, Jae-Han;Oh, Taek-Keun
    • 농업과학연구
    • /
    • 제47권4호
    • /
    • pp.1049-1056
    • /
    • 2020
  • Ultrafine dust causes asthma and respiratory and cardiovascular diseases when inhaled. Ammonia (NH3) plays a big role in ultrafine dust formation in the atmosphere by reacting with nitrogen oxides (NOx) and sulfur oxides (SOx) emitted from various sources. The agricultural sector is the single largest contributor of NH3, with the vast majority of emissions ensuing from fertilizers and livestock sector. Interest in using biochar to attenuate these NH3 emissions has grown. This experiment was conducted to study the effects of using rice hull biochar pyrolyzed at three different temperatures of 250℃ (BP 4.6, biochar pH 4.6), 350℃ (BP 6.8), and 450℃ (BP 10.3) on the emission of ammonia from soil fertilized with urea. The emissions of NH3 initially increased as the experiment progressed but decreased after peaking at the 84th hour. The amount of emitted NH3 was lower in soil with biochar amendments than in that without biochar. Emissions amongst biochar-amended soils were lowest for the BP 6.8 treatment, followed in an ascending order by BP 10.3 and BP 4.6. Since BP 6.8 biochar with neutral pH resulted in the lowest amount of NH3 emitted, it can be concluded that biochar's pH has an effect on the emissions of NH3. The results of this study, therefore, indicate that biochar can abate NH3 emissions and that a neutral pH biochar is more effective at reducing gaseous emissions than either alkaline or acidic biochar.

선형엑츄에이터를 이용한 실내 공기질 개선 시스템에 대한 연구 (A Study on Indoor Air-quality Improvement System Using Actuator)

  • 서도원;윤근영
    • 한국전자통신학회논문지
    • /
    • 제16권1호
    • /
    • pp.183-190
    • /
    • 2021
  • 본 논문은 실내 공기질 개선을 위한 스마트 공기청정 시스템 구현 및 구동에 관한 연구이다. 최근 다양한 환경적 요인으로 인해 실내 공기질 오염에 따른 문제가 심각해지고 있다. 본 연구에서는 이와 같은 실내 공기질 오염의 문제점을 개선하기 위해, IoT 센서를 활용한 스마트 공기청정 시스템을 구현하고자 한다. 특히 공기질 오염도를 실시간으로 측정하고, 오염도에 따라 서로 다른 공기 정화 경로를 가변시켜 줄 수 있는 시스템을 제안하였다. 이를 통해 효율적인 공기질 개선 및 필터의 수명 연장, 시스템 에너지 저감 등을 검토하였다. 또한 실내 공기질 개선 시스템에 대한 기능을 구현하기 위해 주요 부품을 선정하였고, 시제품을 제작하여 동작성을 확인하였다. 최종적으로 선형엑츄에이터를 활용한 실내 공기질 개선 시스템의 구현을 통해, 공기질 개선에 대한 효용성을 검토하였다.

지하철 역사 내 코로나 바이러스 저감을 위한 이온풍 집진기 개발 (Development of an ionic wind dust collector towards coronavirus reduction in subway stations)

  • 신동호;김영훈;한방우
    • 한국입자에어로졸학회지
    • /
    • 제18권1호
    • /
    • pp.1-8
    • /
    • 2022
  • Since 2019, the corona virus has been continuously affect human life. In particular, in the indoor space where people live, infection by airborne transmission of viruses is a problem. Among them, the spread in the subway, which is the main mode of transport for humans, can be serious. To solve this problem, our research team developed an ionic wind collector to collect and remove corona virus using an ionic wind collector and ozone. In order to apply the ionic wind collector to the subway, it must operate in two modes. Because large amounts of ozone are harmful to the human body. There is a mode that collects bio-aerosol from the air using ionic wind and a mode that inactivates viruses floating in the air by generating a large amount of ozone. As the applied voltage increased, the cleaning ability of the ionic wind collector increased, and the farther the distance between the discharge electrode and the ground plate, the higher the cleaning ability even at low current. In addition, clean air delivery rate (CADR) of an ionic wind collector was up to 5.5 m3/min. As a result of measuring the amount of ozone generated, it was confirmed that 50 ppb to 250 ppb was generated, and it was confirmed that ozone generation was controllable in the ionic wind dust collector.

Simultaneous Determination of Polycyclic Aromatic Hydrocarbons and Their Nitro-derivatives in Airborne Particulates by Using Two-dimensional High-performance Liquid Chromatography with On-line Reduction and Fluorescence Detection

  • Boongla, Yaowatat;Orakij, Walaiporn;Nagaoka, Yuuki;Tang, Ning;Hayakawa, Kazuichi;Toriba, Akira
    • Asian Journal of Atmospheric Environment
    • /
    • 제11권4호
    • /
    • pp.283-299
    • /
    • 2017
  • An analytical method using high-performance liquid chromatography (HPLC) with fluorescence (FL) detection was developed for simultaneously analyzing 10 polycyclic aromatic hydrocarbons (PAHs) and 18 nitro-derivatives of PAHs (NPAHs). The two-dimensional HPLC system consists of an on-line clean-up and reduction for NPAHs in the 1st dimension, and separation of the PAHs and the reduced NPAHs and their FL detection in the 2nd dimension after column-switching. To identify an ideal clean-up column for removing sample matrix that may interfere with detection of the analytes, the characteristics of 8 reversed-phase columns were evaluated. The nitrophenylethyl (NPE)-bonded silica column was selected because of its shorter elution band and larger retention factors of the analytes due to strong dipole-dipole interactions. The amino-substituted PAHs (reduced NPAHs), PAHs and deuterated internal standards were separated on polymeric octadecyl-bonded silica (ODS) columns and by dual-channel detection within 120 min including clean-up and reduction steps. The limits of detection were 0.1-9.2 pg per injection for PAHs and 0.1-140 pg per injection for NPAHs. For validation, the method was applied to analyze crude extracts of fine particulate matter ($PM_{2.5}$) samples and achieved good analytical precision and accuracy. Moreover, the standard reference material (SRM1649b, urban dust) was analyzed by this method and the observed concentrations of PAHs and NPAHs were similar to those in previous reports. Thus, the method developed here-in has the potential to become a standard HPLC-based method, especially for NPAHs.

비산먼지 저감기능을 구비한 슬러지 흡입식 도로절단기의 작업생산성 분석 (Work Productivity Analysis of Sludge Suction Type Pavement Cutter Equipped with Scattered Dust Reduction Function)

  • 전은비;김균태
    • 한국건설관리학회논문집
    • /
    • 제24권4호
    • /
    • pp.3-13
    • /
    • 2023
  • 본 연구는 국내에서 주로 사용되는 습식 도로절단기와 비산먼지 저감을 위해 개발된 슬러지 흡입식 도로절단기(이하 자동식 도로절단기)의 작업생산성을 비교 분석하여 자동식 도로절단기의 성능 및 활용성을 검증하는 것을 목적으로 한다. 이를 위해 먼저 국내에서 주로 사용되는 습식 수동식 도로절단기와 자동식 도로절단기의 개발 현황을 조사하고, 도로 절단 작업을 세부적으로 분석하였다. 또한, 동일한 조건의 테스트베드에 두 장비를 적용하여 깊이별 절단 시간을 측정하여, 표준절단 성능을 도출하였다. 하지만 테스트베드에서 측정된 데이터는 실제 도로절단 현장의 다양한 변수를 반영하지 못한다는 한계가 있다. 따라서 본 연구에서는 현장 조사를 통해 데이터를 수집하여 절단 거리와 시간 사이의 상관성을 분석한 후, 단순회귀분석을 통해 도로절단기 생산성 산정모델을 제시하였다. 회귀식에서 도출된 값을 테스트베드에서 도출한 표준절단 성능과 비교 분석한 결과, 회귀분석식을 통해 도출한 절단 성능은 표준절단 성능과 유사한 경향을 보였다. 마지막으로, 정량적으로 측정하기는 어려우나 생산성에 영향을 주는 세가지 세부작업에 대해 정성적으로 비교 분석하여 개발된 자동식 도로절단기의 활용성을 검증하였다.

석탄화력발전소 호흡성분진 작업환경 평가 전략 사례에 관한 연구 (A Study on Occupational Environment Assessment Strategies for Respirable Particulate Matter at Coal-Fired Power Plants )

  • 이은승;이윤근;신동일
    • 한국산업보건학회지
    • /
    • 제33권3호
    • /
    • pp.375-383
    • /
    • 2023
  • Objectives: Coal-fired power plants feature diverse working conditions, including multi-layered employment structures and irregular work cycles due to outsourcing and non-standardized tasks. The current uniform occupational environment measurement systems have limitations in accurately assessing and evaluating these varied conditions. This study aims to propose alternative measurement and assessment strategies to supplement existing methods. Methods: Major domestic coal-fired power plants were selected as the study targets. To prepare for the study and establish strategies, work processes were identified and existing occupational environment measurement results were compared and analyzed. The study proceeded by employing three strategies: specific exposure groups (SEGs) measurement, continuous monitoring, and supplementary measurements, which were then compared and discussed. Results: Previous exposure index evaluations (5,268 cases) indicated that crystalline silica, a type of respirable particulate matter, had detection limits below the threshold (non-detectable) in 82.6% (4,349 cases) of instances. Exposures below 10% of the exposure limit were observed at a very low concentration of 96.1%. Similar exposure group measurements yielded results where detection limits were below the threshold in 38.2% of cases, and exposures below 10% of the limit were observed in 70.6%. Continuous monitoring indicated detection limits below the threshold in 12.6% of cases, and exposures below 10% of the limit were observed in 75.6%. Instances requiring active workplace management accounted for more than 30% of cases, with SEGs at 11.8% (four cases), showing a higher proportion compared to 3.0% (four cases) in continuous monitoring. For coal dust, exposures below 10% of the limit were highest in legal measurements at 90.2% (113 cases), followed by 74.0% (91 cases) in continuous monitoring, and 47.0% (16 cases) in SEGs. Instances exceeding 30% were most prevalent in SEGs at 14.7% (five cases), followed by legal measurements at 5.0% (eight cases), and continuous monitoring at 2.4% (three cases). When examining exposure levels through arithmetic means, crystalline silica was found to be 104.7% higher in SEGs at 0.0088 mg/m3 compared to 0.0043 mg/m3 in continuous monitoring. Coal dust measurements were highest in SEGs at 0.1247 mg/m3, followed by 0.1224 mg/m3 in legal measurements, and 0.0935 mg/m3 in continuous monitoring. Conclusions: Strategies involving SEGs measurement and continuous monitoring can enhance measurement reliability in environments with irregular work processes and frequent fluctuations in working conditions, as observed in coal-fired power plants. These strategies reduce the likelihood of omitting or underestimating processes and enhance measurement accuracy. In particular, a significant reduction in detection limits below the threshold for crystalline silica was observed. Supplementary measurements can identify worker exposure characteristics, uncover potential risks in blind spots of management, and provide a complementary method for legal measurements.

기능변화를 반영한 서울어린이대공원 조성녹지의 식재 리뉴얼 방향성 연구 (A Study on the Direction of Planting Renewal in the Green Area of Seoul Children's Grand Park Reflecting Functional Changes)

  • 박정아;한봉호;박석철
    • 한국조경학회지
    • /
    • 제51권3호
    • /
    • pp.21-36
    • /
    • 2023
  • 기후변화 대응, 탄소중립 전략, 도시열섬, 미세먼지, 생물다양성 증진 등 환경이슈에 대한 해결책으로 도시녹지와 수목의 가치가 중요해지고 있으며 다양한 연구들이 도시환경개선을 위한 수목의 효과를 다루고 있다. 따라서 본 연구는 도시환경개선 측면에서 식재수종, 식재구조, 식재밀도, 식재기반의 선행연구를 종합적으로 고찰하여 도시공원 조성녹지의 식재 리뉴얼 방향성을 제안하고 이를 리뉴얼 계획에 적용해 조경수목을 통한 도시환경개선 효과를 제고하는 데 목적이 있다. 서울시 내 대규모 근린공원인 서울어린이대공원의 식재현황을 현장조사하고 조사자료를 근거로 식재기능평가를 했으며 식재기능개선 필요지역을 중첩 도출하였다. 식재기능평가는 공원기능 설정, 공간기능에 따른 식재개념, 식재현황 단계별로 수행하였고, 연구의 결과인 기능변화에 따른 식재 리뉴얼 방향은 식재기능평가 단계별로 도출하였다. 공원기능 설정은 녹지율을 높이는 것이 우선이나 이용자 편의도 고려해야 하며, 식재개념으로 시각적 경관식재는 교목층은 수형이 아름답고 탄소흡수와 미세먼지 저감효과가 높은 수종을 식재, 생태적 경관식재는 경사구배 위 다층구조 식재지 조성, 완충식재는 다층구조숲으로 조성하여 탄소흡수와 미세먼지 저감 효과 향상, 녹음식재는 활엽수 교목층과 초본층으로 구성하고 초본류의 자연형 식재를 지향해야 한다. 식재수종은 도시환경개선 효과가 높은 수종, 지역 자생종, 야생조류 선호 수종을 식재하고, 식재구조는 경관식재지와 녹음식재지는 교목층과 관목층, 교목층과 초본층으로 구성하고 생태성이 강조되거나 완충기능이 필요한 식재지는 다층구조로 조성한다. 식재밀도는 식재간격 기준으로 더 높은 기준을 적용하며, 식재기반은 빗물재활용과 토양객토 및 통기시설을 사용한다. 본 연구의 결과는 향후 노후 도시공원의 식재리뉴얼 계획 시 식재기능평가를 수행하여 식재기능개선 필요지역을 도출하는 데 적용할 수 있으며, 조성녹지의 기능변화 패러다임을 다각도로 반영한 식재 리뉴얼 방향성을 제시했다는 점에서 의의가 있다.

폐기물을 재활용한 소성벽돌의 미세구조 분석 (Microstructural analysis of sintered brick made of recycled wastes)

  • 엄태호;김유택;이기강;강승구;김정환
    • 한국결정성장학회지
    • /
    • 제13권4호
    • /
    • pp.199-204
    • /
    • 2003
  • 전기로 더스트, 석탄회, 석분 등 폐기물을 재활용한 소성벽돌의 미세구조 및 조성분포를 SEM과 EBS로 분석하였다. 소성벽돌 시편 중 일부에서 갈색 매트릭스 위에 노란색 영역이 발견되었고 내부에는 갈색 영역 외에 흑색 black-core 영역이 존재하였다. 표면의 노란색 영역은 Zn이 주성분이었으며 흑색 black-core 영역은 매트릭스와 조성차이는 보이지 않았다. 소성벽돌 시편의 전 부분에 걸쳐 1$\mu\textrm{m}$ 크기의 mullite 결정상이 분포하고 있었으며 유리질에 의해 둘러싸여져 있었다. 이는 고령토와 석탄회 내의 alumino-silicate 화합물이 소성과정에서 meta-kaolinite를 거쳐 mullite로 전이된 것으로 사료된다. 시편 외부는 산화분위기가 조성되나 내부는 석탄회 및 더스트에 함유되어 있는 미연탄소분에 의해 환원분위기가 조성 되면서 발생한 가스에 의해 발포되어 흑색 black-core 영역에서는 수십 fm 크기의 구형 기공이 발견되었다. 벽돌 내부는 Al과 Si가 주성분이었고 소량의 Fe, K, Ca, Na를 포함하고 있었다 특히 Fe는 비정질상 표면에 원판형 Fe-rich 결정상으로 석출되어 존재하고 있었다. 시편 내부에서는 상대적으로 적은 양의 Zn이 발견되었고 외부에서는 내부에 있던 Zn이 환원되면서 표면으로 확산되어 Zn-rich 결정상을 표면에 형성하여 노란색 표피층을 형성하였다.

제올라이트와 활성 황토를 혼입한 시멘트 모르타르의 광촉매(TiO2) 코팅에 따른 NOx 저감성능평가 (Evaluation of NOx Reduction Performance by Photocatalytic (TiO2) Coating of Cement Mortar Mixed with Zeolite and Activate Hwangtoh)

  • 박장현;김혁중
    • 한국건설순환자원학회논문집
    • /
    • 제8권4호
    • /
    • pp.483-489
    • /
    • 2020
  • 미세먼지는 머리카락 두께의 약 1/5 수준인 PM10(입자의 지름 10㎛이하)과 PM2.5(입자의 지름 2.5㎛이하)로 구분되며, 인체에 미치는 영향으로 폐질환, 혈관을 통한 동맥경화 및 심장 질환 등 각종 질병을 유발하는 발암물질로 알려져 있다. 이러한 미세먼지의 주요 원인은 도심지 도로변에서 발생되는 약 57.3%가 자동차에서 배출되는 이산화질소(NOx)로 알려져 있다. 이에 본 연구에서는 도로이동오염원에서 발생하는 NOx를 저감하기 위한 기능성 건설재료 개발의 일환으로 시멘트를 다공성 소재로 치환한 시멘트 모르타르의 치환율에 따른 NOx저감성능 비교 평가를 실시하였다. 또한 시멘트 모르타르의 광촉매 적용방법 및 도포 횟수에 따른 NOx저감성능을 비교 평가하였다. 실험결과 활성황토를 30% 치환하여 사용한 경우 약 32.7%의 저감효과를 나타내 가장 우수한 저감성능을 갖는 것으로 나타났다.