• Title/Summary/Keyword: Dust reduction

Search Result 278, Processing Time 0.026 seconds

Analysis of the Factors Influencing PM10 & PM2.5 in Korea by Panel Quantile-Regression (패널 분위회귀분석을 통한 한국의 미세먼지 국내외 영향요인 분석)

  • Kim, Haedong;Kim, Jaehyeok;Jo, Hahyun
    • Environmental and Resource Economics Review
    • /
    • v.31 no.1
    • /
    • pp.85-112
    • /
    • 2022
  • This study analyzed the influence of domestic and Chinese factors on fine dust(PM10 & PM2.5) in Korea by using the panel quantile regression. Daily analysis was conducted for 11 regions in Korea. For domestic factors, electricity demand and traffic volume, and for Chinese factors, interaction term of Chinese three cities' fine dust and the domestic west wind are used. As a result, the influence of domestic factors was different when the domestic fine dust concentration was high and low. When the fine dust concentration was low, electricity demand had a positive effect only on PM2.5, and didn't affect PM10 in the national analysis. In regional analysis, the amount of electricity demand had a significant effect on fine dust and ultrafine dust only in the capital area and Chungcheong. Electricity demand was found to significantly increase both PM2.5 and PM10 when it was high. On the other hand, it was confirmed that the Chinese factor always had a significant effect regardless of the concentration of PM10 and PM2.5. Therefore, in order to solve the problem of high concentration of fine dust, in addition to international cooperation, the reduction of PM2.5 generated by domestic thermal power generation should also be strengthened compared to the present.

A Study on the Trace Analysis of Germanium in Inorganic Matrices by Differential Pulse Polarography (Differential Pulse Polarography에 의한 무기물 시료 중 Germanium의 미량 분석에 관한 연구)

  • Shin, Ho-Sang;Oh, Yun-Suk;Shin, Hak-Soo
    • Analytical Science and Technology
    • /
    • v.9 no.3
    • /
    • pp.253-261
    • /
    • 1996
  • Analytical method for the determination of trace germanium in inorganic matrices by differential pulse polarography(DPP) was studied. The reduction peak of germanium(IV) in perchloric acid solution containing 1, 2, 3-trihydroxy benzene appeared at -0.45V(vs. Ag/AgCl) and the peak current for germanium complex varied linearly with concentration variation. Factors affecting sensitivity and precision for germanium quantification were studied and detection limit under the investigated parameters was 1ng/ml. Inorganic samples were decomposed by fusion with potassium pyrosulfate. Serious interferences of Se(IV), Pb(II), As(III) for the determination of germanium were discussed. Interferences of these elements could be avoided by extraction of germanium from decomposed matrices by $CCl_4$ in 10M HCl solution. The germanium contents of inorganic samples(Pb bf. dust, Cu bf. dust, gneiss, Cu anode slime) were determined by the above method.

  • PDF

A Study on the Reduction of Environmental Civil Appeals for In-site Crusher Facilities (현장파쇄시설의 환경민원 발생 저감방안 연구)

  • Jung, Jong-Suk;Lee, Jae-Sung;Lee, Kyoung-Hee;Jun, Myoung-Hoon;Bae, Kee-Sun
    • Korean Journal of Construction Engineering and Management
    • /
    • v.9 no.5
    • /
    • pp.176-185
    • /
    • 2008
  • Recently, the construction wastes rapidly increase because of redevelopment, the development of new urbanization of large housing development, the expansion of social infrastructure. With increase of the construction noise, vibration, and dust caused by these developments, environmental conflicts and civil appeals increase. Moreover, the Government will reduce environmental level in the near future. Therefore, it will be expected to increase environmental conflicts and civil appels related to construction noise, vibration, and dust. To minimize environmental conflicts and civil appels, this study suggest the plan of prevention of environmental confliction and civil appeal by analyzing and measuring vibration, noise level, and dust of in-site crusher facilities at large and development district.

An Method for Inferring Fine Dust Concentration Using CCTV (CCTV를 이용한 미세먼지 농도 유추 방법)

  • Hong, Sunwon;Lee, Jaesung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.10
    • /
    • pp.1234-1239
    • /
    • 2019
  • This paper proposes a method for measuring fine dust concentration through digital processing of images captured by only existing CCTVs without additional equipment. This image processing algorithm consists of noise reduction, edge sharpening, ROI setting, edge strength calculation, and correction through HSV conversion. This algorithm is implemented using the C ++ OpenCV library. The algorithm was applied to CCTV images captured over a month. The edge strength values calculated for the ROI region are found to be closely related to the fine dust concentration data. To infer the correlation between the two types fo data, a trend line in the form of a power equation is established using MATLAB. The number of data points deviating from the trend line accounts for around 12.5%. Therefore, the overall accuracy is about 87.5%.

Estimating Social Benefits According to Exhaust Gas Reduction Devices (DPF) (배출가스 저감장치(DPF) 부착에 따른 사회적 편익 추정)

  • Choi, Soungkyu;Kim, Yongdal;Kim, Hogyeong;Bae, Jinmin
    • Journal of Auto-vehicle Safety Association
    • /
    • v.10 no.3
    • /
    • pp.27-31
    • /
    • 2018
  • The People have a bad perception about diesel vehicle because of serious air pollution, increase fine dust and global vehicle company's diesel gate. Starting the project in 2005, Ministry of Environment has been supporting that is exhaust gas reduction devices (DPF) on diesel vehicles in the metropolitan area. During the period of 2017.01.01 to 2017.12.31, 10,030 diesel vehicles installed exhaust gas reduction devices (DPF). Among them, 9,921 diesel vehicles that they have sufficient data for analysis were analyzed amount of particulate matter reduction before and after exhaust gas reduction devices (DPF) was installed. Opacity smoke meter measures the concentration of particulate matter. So concentration of particulate matter was converted into a mass unit, and then calculated the total amount of reduced particulate matter. It was estimated that social benefits is costs required to remove it from the total amount of particulate matter.

Study on PM10, PM2.5 Reduction Effects and Measurement Method of Vegetation Bio-Filters System in Multi-Use Facility (다중이용시설 내 식생바이오필터 시스템의 PM10, PM2.5 저감효과 및 측정방법에 대한 연구)

  • Kim, Tae-Han;Choi, Boo-Hun
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.48 no.5
    • /
    • pp.80-88
    • /
    • 2020
  • With the issuance of one-week fine dust emergency reduction measures in March 2019, the public's anxiety about fine dust is increasingly growing. In order to assess the application of air purifying plant-based bio-filters to public facilities, this study presented a method for measuring pollutant reduction effects by creating an indoor environment for continuous discharge of particle pollutants and conducted basic studies to verify whether indoor air quality has improved through the system. In this study conducted in a lecture room in spring, the background concentration was created by using mosquito repellent incense as a pollutant one hour before monitoring. Then, according to the schedule, the fine dust reduction capacity was monitored by irrigating for two hours and venting air for one hour. PM10, PM2.5, and temperature & humidity sensors were installed two meters front of the bio-filters, and velocity probes were installed at the center of the three air vents to conduct time-series monitoring. The average face velocity of three air vents set up in the bio-filter was 0.38±0.16 m/s. Total air-conditioning air volume was calculated at 776.89±320.16㎥/h by applying an air vent area of 0.29m×0.65m after deducing damper area. With the system in operation, average temperature and average relative humidity were maintained at 21.5-22.3℃, and 63.79-73.6%, respectively, which indicates that it satisfies temperature and humidity range of various conditions of preceding studies. When the effects of raising relatively humidity rapidly by operating system's air-conditioning function are used efficiently, it would be possible to reduce indoor fine dust and maintain appropriate relative humidity seasonally. Concentration of fine dust increased the same in all cycles before operating the bio-filter system. After operating the system, in cycle 1 blast section (C-1, β=-3.83, β=-2.45), particulate matters (PM10) were lowered by up to 28.8% or 560.3㎍/㎥ and fine particulate matters (PM2.5) were reduced by up to 28.0% or 350.0㎍/㎥. Then, the concentration of find dust (PM10, PM2.5) was reduced by up to 32.6% or 647.0㎍/㎥ and 32.4% or 401.3㎍/㎥ respectively through reduction in cycle 2 blast section (C-2, β=-5.50, β=-3.30) and up to 30.8% or 732.7㎍/㎥ and 31.0% or 459.3㎍/㎥ respectively through reduction in cycle 3 blast section (C-3, β=5.48, β=-3.51). By referring to standards and regulations related to the installation of vegetation bio-filters in public facilities, this study provided plans on how to set up objective performance evaluation environment. By doing so, it was possible to create monitoring infrastructure more objective than a regular lecture room environment and secure relatively reliable data.

Combustion Characteristics of Wood Materials (1) (Mass Reduction and Ignition Delay) (목재의 연소특성(1) (질량감소와 착화지연))

  • Kim, Chun-Jung
    • Journal of the Korean Society of Combustion
    • /
    • v.4 no.2
    • /
    • pp.11-22
    • /
    • 1999
  • Combustion characteristics of the wood chips(balsa chips) were experimentally investigated with respect to the thermal recycle system of the urban waste. The urban waste contains plastics, vegetable and wood materials. Wood was chosen as an example of the one of the component of urban dust. A small wood chip was burned in a electric furnace by the micro-electric balance. The mass reduction rate was normalized by the initial mass of test piece and the time of volatile combustion end. When the mass of the wood chips(balsa chips) was larger than 0.5g, the combustion similarity was found on the normalized mass reduction rate.

  • PDF

Noise Reduction Method and Sources of Cyclone Sound for Vacuum Cleaner (청소기용 Cyclone 소음원 및 저감방법)

  • Lee, Jun-Hwa;Hong, Seung-Gee;Joo, Jae-Man;Oh, Sang-Kyoung;Song, Hwa-gyu;Oh, Jang-Keun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.4 s.97
    • /
    • pp.452-456
    • /
    • 2005
  • Cyclone is widely adopted in the vacuum cleaner, because of the simple structure, the high dust collection efficiency and its transparency feature, which can be shown to the customer. At past times, cyclone performance was represented by collection efficiency, flow rate, pressure drop etc. At recent times the noise problem is getting important as cyclone comes into home-appliances. In this paper, pressure drop of cyclone and it's noise were measured at the variation of the cyclone structure and the main sources of cyclone peak noise was found by experimental and numerical analysis. In addition, the structure for peak noise reduction was suggested and it is beneficial both pressure drop and noise reduction.

Noise Reduction Method and Sources of Cyclone for Vacuum Cleaner (청소기용 Cyclone 소음원 및 저감방법)

  • Lee, Jun-Hwa;Hong, Seung-Gee;Joo, Jae-Man;Oh, Sang-Kyong;Song, Hwa-Gyu;Oh, Jang-Keun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.89-92
    • /
    • 2004
  • Cyclone is widely apoted in the vacuum cleaner, because of it's simple structure, the dust collection efficiency is high and its transparency feaure which can be shown to the customer. At past times, cyclone performance is represented by collection efficiency, flow rate, pressure drop etc. At recent times the noise problem is getting important as cyclone comes into home-appliances. In this paper, cyclone's pressure drop and noise is measured at the variation of the cyclone structure and the main sources of cyclone peak noise is found by experiments and numerical analysis. In addition, the structure for peak noise reduction is suggested and it is beneficial both pressure drop and noise reduction.

  • PDF

An Exploratory Study on the Effect of LCZ Type on Particulate Matter (LCZ 유형이 미세먼지에 미치는 영향에 관한 탐색적 연구)

  • Yeonju Kim;Hansol Mun;Juchul Jung
    • Journal of Environmental Impact Assessment
    • /
    • v.32 no.5
    • /
    • pp.338-352
    • /
    • 2023
  • As of 2019, Korea's fine dust is the most severe among 38 OECD countries, and in the same year, 「the Framework on Disaster and Safety Management」 was revised to define fine dust as a social disaster. Currently, the government is working to achieve its emission reduction goals by preparing a comprehensive fine dust management plan (2022-2023) consisting of a total of five areas, 42 tasks, and 177 detailed tasks. However, it is necessary to come up with measures in consideration of the various spatial characteristics of the city, not just as a source of emission. Therefore, in this study, the shape of the city was classified using the LCZ (Local Climate Zone) classification system into 17 types by building type and land cover type in Busan, and the average annual PM10 and PM2.5 concentration were mapped using the IDW technique. In addition, Fragstats and Moving Window were used to quantify the LCZ classification system. Finally, correlation analysis and regression analysis were conducted to analyze the relationship between the LCZ classification system and PM10 and PM2.5. As a result, it was confirmed that the type of low height of the building and the type of green space with trees had a positive effect on the concentration of PM10 and PM2.5. Therefore, this study is expected to be used as basic data to establish fine dust reduction policies based on efficient spatial planning.