• Title/Summary/Keyword: Dust particles

Search Result 496, Processing Time 0.025 seconds

A Study on the Variation of Aerosol Optical Depth according to Aerosol Types in Northeast Asia using Aeronet Sun/Sky Radiometer Data (AERONET 선포토미터 데이터를 이용한 동북아시아 지역 대기 에어로졸 종류별 광학적 농도 변화 특성 연구)

  • Noh, Youngmin
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.34 no.5
    • /
    • pp.668-676
    • /
    • 2018
  • This study has developed a technique to divide the aerosol optical depth of the entire aerosol (${\tau}_{total}$) into the dust optical depth (${\tau}_D$) and the pollution particle optical depth (${\tau}_P$) using the AERONET sun/sky radiometer data provided in Version 3. This method was applied to the analysis of AERONET data observed from 2006 to 2016 in Beijing, China, Seoul and Gosan, Korea and Osaka, Japan and the aerosol optical depth trends of different types of atmospheric aerosols in Northeast Asia were analyzed. The annual variation of ${\tau}_{total}$ showed a tendency to decrease except for Seoul where observation data were limited. However, ${\tau}_D$ tended to decrease when ${\tau}_{total}$ were separated as ${\tau}_D$ and ${\tau}_P$, but ${\tau}_P$ tended to increase except for Osaka. This is because the concentration of airborne aerosols, represented by Asian dust in Northeast Asia, is decreased in both mass concentration and optical concentration. However, even though the mass concentration of pollution particles generated by human activity tends to decrease, Which means that the optical concentration represented as aerosol optical depth is increasing in Northeast Asia.

Properties of Zinc and Lead Hydroxyl Chloride in EAF Dust

  • Lee, Sung-Oh;Ko, In-Yong;Shin, Bang-sup;Oh, Jae-Hyun
    • Resources Recycling
    • /
    • v.7 no.1
    • /
    • pp.7-13
    • /
    • 1998
  • The electric arc furnace (EAF) dust used in this experiment showed the formation of an irregular agglomerate of small spherical particles and consisted of 27.5% Fe, 18% Zn, 4.83% Pb and 10.2% CaO, and it also contained 3.26% Cl and 0.15% F. IR spectra peaks of Pb(OH)Cl were observed at 1630 and 1377 ${cm}^{-1}$ regions and the intensity decreased using an acid treatment (1N ${H}_{2}{SO}_{4}$) and thermal treatment at above 600℃, but it was not affected by washing process. Those of ${Zn}_{5}{(OH)}_{8}{Cl}_{2}$ treated by oxidation showed broad absorption peak at 3600∼3200 ${cm}^{-1}$, main peaks at 1136 and 1040 ${cm}^{-1}$ and a splitting peak at 991 and 921 ${cm}^{-1}$ which were believed to be due to ZnO by oxidation at about 700∼. The IR spectra of the dust residues by a washing process show the same peaks at 3449, 1635, 1439, 875, 571 and 455 ${cm}^{-1}$ regions, but the peaks at 2942, 2862, 1136 and 1040 ${cm}^{-1}$ decreased and disappeared using an acid treatment and washing process, which is believed to be due to the dissolution of zinc hydroxyl chloride.

  • PDF

Cytotoxicity of Dichloromethane Extracts of Asian Dust

  • Park, Eun-Jung;Kim, Dae-Seon;Yu, Seong-Do;Park, Kwang-Sik
    • Journal of Environmental Health Sciences
    • /
    • v.36 no.4
    • /
    • pp.271-278
    • /
    • 2010
  • The appearance of Asian Dust (AD) originating from China and Mongolia during spring each year is a meteorological phenomenon periodically observed in extensive regions of East Asia. According to a previous epidemiological study, AD has adverse effects on both human beings and ecosystems. In this study, we collected total suspension particles (TSP) in the AD period and Non-AD (NAD) period. We extracted organic components from TSP using dichloromethane (DCM), and the polyaromatic hydrocarbons (PAHs) were analyzed. The DCM extracts contained PAHs such as benzo(b)fluoranthene, benzo[g,h,i]perylene, benzo(k)fluoranthene, benzo(a)pyrene, and pyrene. No significant difference was observed in cytotoxicity of the DCM extracts from AD versus NAD when tested on the human bronchial epithelial cells, BEAS-2B. e also examined the toxic mechanisms of AD extracts in cultured BEAS-2B cells and RAW264.7 cells, and in BEAS-2B cells observed increased levels of reactive oxygen species (ROS), decreased glutathione (GSH), and induced caspase-3 activity. Increased expression of oxidative stress-related and inflammation- related genes were also observed in BEAS-2B cells, while nitric oxide (NO) levels were increased in RAW264.7 cells. Taken together, the results suggest that in these cultured cells, AD may induce cytotoxicity through oxidative stress and pro-inflammatory signals.

Development of a remote monitoring system for gas detection at the subway station (지하철 역내 가스 검출 원격 모니터링 시스템 구현)

  • Park, Yong-Man;Kim, Hei-Sik;Kim, Gyu-Sik;Lee, Moon-Gyu
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.439-441
    • /
    • 2007
  • The seoul metropolitan subway has installed 8 lines and about 500 stations to transport 5 million passengers everyday. The underground air pollution level in the subway stations is very severe status, which is very harmful to the commutators and its personals. Although subway roles as such a massive and huge transportation system, the subway doesn't adapt yet any real-time air monitoring system. They have only some hand-held type detector equipments for monitoring air pollution. Therefore subway passengers are exposed to the harmful air pollution environment. The most harmful environmental parameters among the air pollution are known as the dust and sound noise dB level in the subway station. Because the dust is consisted of very small particles, we can't see them easily in dark condition on the platform, but it is very harmful. The monitoring system for air pollution is developed using embedded system attached with 6 different environmental sensors. This system monitors air pollution of dust sound noise, gas, temperature, humidity, inflammable gas, toxic gas in the subway ?station. The sensor unit of the ARM-CPU board and sensor transmits real time environmental data to the main server using Zigbee wireless communication module and TCP/IP network. The main control server receives and displays the real-time environmental data, and it send alarms to the personals when high level value.

  • PDF

A Study on Filtration Performance Test with Electrostatically Enhanced Fabric Filter (정전형여과집진방식에서 여과특성에 관한 연구)

  • 천중국;박출재;최금찬
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.11 no.4
    • /
    • pp.361-367
    • /
    • 1995
  • This study has been carried out to investigate the filteration performance of Electrostatically Stimulated Fabric Filter(ESFF) at high temperature condition. The electric field was maintained parallel to the fabric surface. The benefits of ESFF are lower residual pressure drop, improvement of fine particle removal efficiency and increasing reduced rate of pressure drop during a filteration cycle, stable operation at higher filtering velocities. According to the variance of filtering velocities and dust loadings, the results are summarized as follows; By imposing an electric field on the filter, the reduced rate of pressure drop was 7.sim.18% at room temperature, and when filtering velocity was 1.8m/min and dust loading was 1g/m$^{3}$, the value of reduced rate of pressure drop was shown the highest. Under the electric field around the filter, the reduced rate of pressure drop was 10.sim.35% at high temperature, and when filtering velocity was 1.8m/min and dust loading was 1g/m$^{3}$, the value of reduced rate of pressure drop was shown the highest. Most of all, at high temperature, the value of reduced rate of pressure drop was resulted to 25%. Also the collecting efficiency was shown clearly improved. By the SEM photo analysis, the number of penetrated particles at the Conventional Fabric Filter was approximately two times that of Electrostatically Stimulated Fabric Filter.

  • PDF

Physicochemical Properties of Asian Dust Sources

  • Ma, Chang-Jin;Kasahara, Mikio;Tohno, Susumu;Kim, Ki-Hyun
    • Asian Journal of Atmospheric Environment
    • /
    • v.2 no.1
    • /
    • pp.26-33
    • /
    • 2008
  • In order to fully understand the chemical properties of Asian dust particles, especially their transformation and aging processes, it is desirable to investigate the nature of original sands collected at local source areas in China. This study presents the detailed properties of sands collected at four different desert regions (Yinchuan, Wuwei, Dulan, and Yanchi) in China. Most of sands have irregular shape with yellowish coloration, whereas some of them show peculiar colors. The relative size distribution of sands collected at Yinchuan, Wuwei, and Dulan deserts exhibits monomodal with the maximum level between 200 and $300{\mu}$, whereas that of Yanchi desert is formed between 100 and $200{\mu}$. The mass concentration ratio of each element to that of Si (Z/Si) determined by PIXE analysis has a tendency towards higher Z/Si ratios for soil derived elements. It was possible to visually reconstruct the elemental maps on the surface of individual sands by XRF microprobe technique. In addition, the multielemental mass concentration could be quantitatively calculated for numerous spots of desert sands.

A Study on Optimum Design of an Axial Cylcone structure using Response Surface Method (반응표면법을 활용한 축류형 사이클론 구조 최적화 설계에 관한 연구)

  • Cho, Jinill;Yun, Junho;Cho, Yeongkwang;Seok, Hyunho;Kim, Taesung
    • Particle and aerosol research
    • /
    • v.17 no.3
    • /
    • pp.71-79
    • /
    • 2021
  • Ultrafine dust, which is emitted from industrial factories or all kinds of vehicles, threatens the human's respiratory system and our environment. In this regard, separating airborne particles is essential to mitigate the severe problem. In this work, an axial cyclone for the effective technology of eliminating harmful dust is investigated by numerical simulation using Ansys 2020, Fluent R2. In addition, the optimized structure of the cyclone is constructed by means of multi objective optimization based on the response surface method which is a representative method to analyze the effect of design parameter on response variables. Among several design parameters, the modified length of the vortex finder and dust collector is a main point in promoting the performance of the axial cyclone. As a result, the optimized cyclone exhibits remarkable performance when compared to the original model, resulting in pressure drop of 307 Pa and separator efficiency of 98.5%.

Numerical Analysis on the Ventilation System Improvement in Air Shot Blast Room (Air Shot Blast 작업실 내부 환기 시스템 개선에 관한 수치해석)

  • Chin, Do-Hun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.5
    • /
    • pp.861-868
    • /
    • 2022
  • The purpose of this study is to design an effective atmospheric environment system through the design of the dust collection in the air shot room being operated in a domestic shipyard. The ventilation system in the current air shot room mostly uses a dust collecting filter to filter internal particles and releases them in the atmosphere. A conventional design was made too much. In order to prevent an error and draw an optimal design, Computational fluid dynamics (CFD) tried to be applied only to air shot room. In the advanced design technique, computer simulation was conducted to secure basic design data. In order to find the basic design of the ventilation system and the flow field in the air shot room at propeller mold workplace of a shipyard, the CFD was conducted. In the case of Model-1 as a conventional workplace, where air flows in the inlet due to the subatmospheric pressure generated by inhalation of an air blower and flows out to the outlet, a discharge flow rate was somewhat low, and there was the holdup zone in the room. In the case of Model-2 as an improved model, the ventilation system was improved in the Push-Pull type, and the holdup of the internal flow field was improved.

Concentration Characteristics of Atmospheric PM2.5, PM10 and TSP during the Asian Dust Storm in Iksan Area (익산지역에서 황사발생시 PM2.5, PM10 TSP의 농도 특성)

  • Kang, Gong-Unn;Kim, Nam-Song;Kim, Kyung-Suk;Kim, Mi-Kyung;Lee, Hyun-Ju
    • Journal of Environmental Health Sciences
    • /
    • v.33 no.5
    • /
    • pp.408-421
    • /
    • 2007
  • The concentration characteristics of atmospheric particle matters (PM) including $PM_{2.5},\;PM_{10}$, and TSP were evaluated through the measurement data of PM_{2.5}$ (fine particulate), PM_{10-2.5}$ (coarse particulate), and PM_{over-10}$ collected using a MCI (multi-nozzle cascade impactor) sampler of a three-stage filter pack in spring of 2006 in Iksan area. During the sampling period of 10-15 March and 24 days from 8 April to 2 May, 32 samples for PM of each size fractions were collected, and then measured for PM mass concentrations and water-soluble inorganic ion species. Average concentrations of $PM_{2.5},\;PM_{10}$, TSP were $57.9{\pm}44.1mg/m^3$, $96.6{\pm}89.1mg/m^3$, and $114.8{\pm}99.7mg/m^3$, respectively. Water-soluble inorganic ion fractions to PM mass were found to be 36.5%, 18.0%, and 11.1% for $PM_{2.5}$, $PM_{10-2.5}$ and $PM_{over-10}$, respectively. By showing the high concentrations of PM samples during Asian dust events, those three fractions of PM were distinguished between the samples of Asian dust event and the samples of no event. However, the increase of PM concentrations observed during Asian dust events showed a different pattern for some Asian dust events. The differences of those three fractions in the size distribution may depend on differences on place of occurrence of Asian dust storm and course of transport from China continent to Iksan area in Korea. However, the extent of PM mass contribution during Asian dust events was generally dominated by the coarse particles rather than the fine fraction of PM. The variations of water-soluble inorganic ion species concentration in those three PM fractions between the samples of Asian dust event and the samples of no event were also discussed in this study.

Triboelectrostatic Recovery of High Zinc-Containing Particulate contents from Steel-Making Process Dust (전기로 제강분진 중 고아연함량입자 성분의 마찰대전분리 회수)

  • Chang Hyun-Joo;Kim Dong-Su;Kim Hang-Goo;Cho Min-Yaung;Namkung Won
    • Resources Recycling
    • /
    • v.13 no.2
    • /
    • pp.39-46
    • /
    • 2004
  • The amount of electric furnace dust has been steadily increasing due to the increase of iron scraps which are usually recycled by electric furnace melting process. To date, this electric furnace dust has usually been treated by landfilling, however, because of shortage of landfill sites and heavy metal leaching more desirable treatment schemes are urgently needed. Among several possible schemes for the proper treatment of electric furnace dust, its recycling can be said to be most desirable. In present study, the triboelectrostatic separation of zinc and zinc-containing components from electric furnace dust was attempted based on its physicochemical properties such as particle shape, size distribution, and chemical assay. The dust was found to be mixed with spherical and non-spherical shaped particles and its major component materials were $ZnFe_2$$O_4$, ZnO, Fe, Zn, and FeO. The content of zinc-containing components in the entire dust was observed to be in the range of 15~30 wt%, which reasonably justified that zinc is recyclable. The triboelectrostatic characteristic of each component material was found to be different each other since their work functions were different, and based on this characteristic zinc and zinc-containing component could be flirty separated from the dust. After selecting a proper tribo-elec-trification material, the separation features of zinc and zinc-containing component were examined by taking the distance of electrodes, electric field strength, and scavenging as the experimental variables. The highest zinc-content obtained under the optimal separating condition was found to be up to 50wt%.