• Title/Summary/Keyword: Dust Particles

Search Result 496, Processing Time 0.026 seconds

Radiative Properties of Greenhouse Gases, Aerosols and Clouds in Korea

  • Moon, Yun-Seob;Bang, So-Young;Oh, Sung-Nam
    • 한국환경과학회:학술대회논문집
    • /
    • 한국환경과학회 2003년도 International Symposium on Clean Environment
    • /
    • pp.51-54
    • /
    • 2003
  • We analyzed radiative properties of aerosols, $CO^{2}$ and clouds using Optical Properties of Aerosols and Clouds(OPAC) and the Column Radiation Model (CRM). From OPAC, if the soot component is disregarded, dust-like components depict the highest extinction values in the solar spectral range and the lowest. single scattering albedoes, which are attributable to the presence of large particles. In the dust aerosol, the high absorptivity in the infrared may induce a warming of the lower atmospheric layer in the nighttime. The radiative properties of aerosols, clouds and double $CO^{2}$ using the CRM model at Seoul (37N, 127.4 E) on 3 April 2003 were calculated. The solar zenith angle is 65˚ and the surface albedo is 0.1836 during the clear day. The aerosol optical depth change 0.14 to 1.7, which is derived during Asian dust days in Korea. At this time, abedo by aerosols is considered as 0.3. In cloudy condition, the short wave cloud forcing on both the TOA and the surface is -193.89 $Wm^{-2}$ and -195.03 $Wm^{-2}$, respectively, and the long wave cloud forcing is 19.58 $Wm^{-2}$ and 62.08 $Wm^{-2}$, respectively. As a result, the net radiative cloud forcing is -174.31 $Wm^{-2}$ and -132.95 $Wm^{-2}$, respectively. We calculate also radiative heating rates by double $CO^{2}$ during the clear day. The $CO^{2}$ volumn mixing ratio is 3.55E-4.

  • PDF

제주지역 미세먼지의 오염원 규명에 관한 연구 (A Study on the Source Apportionment of the Atmospheric Fine Particles in Jeju area)

  • Hu, Chul-Goo;Yang, Su-Mi;Lee, Ki-Ho
    • 한국환경과학회지
    • /
    • 제12권2호
    • /
    • pp.217-225
    • /
    • 2003
  • Samples of size-fractionated PM10 (airborne particulate matter with aerodynamic diameter less than $10\mu\textrm{m}$) were collected at an urban site in Jeju city from May to September 2002. The mass concentration and chemical composition of the samples were measured. The data sets were then applied to the CMB receptor model to estimate the source contribution of PM10 in Jeju area. The average PM10 mass concentration was 28.80$\mu\textrm{g}/m^3$ ($24.6~33.49\mu\textrm{g}/m^3$), and the FP (fine particle with aerodynamic diameter less than $2.l\mu\textrm{m}$ fraction in PM10 was approximately 8% higher than the CP (coarse particle with aerodynamic diameter greater than $2.l\mu\textrm{m}$ and less than $10\mu\textrm{m}$ fraction in PM10. The CP composition was obviously different from the FP composition, that is, the most abundant water soluble species was nitrate ion in the FP, but sulfate ion in the CP. Also sulfur was the most dominant element in the FP, however, sodium was that in the CP. From CMB receptor model results, it was found that road dust was the largest contributor to the CP mass concentration (45% of the CP) and ammonium nitrate, domestic boiler, and marine aerosol were major sources to the CP mass. However, the secondary aerosol was the most significant contributor to the FP mass concentration (45% of the FP). In this study, it was suggested that the contributions of soil dust and gasoline vehicle became very low due to collinearity with road dust and diesel vehicle, respectively.

차량용 에어필터 Sealing 및 상.하 Cap의 신기술 개발에 관한 연구 (A Study on New Technology Development of Air Filter Sealing for Vehicles and Upper-under Cap)

  • 윤성운;김재열
    • 한국생산제조학회지
    • /
    • 제18권4호
    • /
    • pp.436-441
    • /
    • 2009
  • An air filter is a device to remove dust from the air supplied to the automotive engine. A requirement for the optimum air filter is to improve the capability to remove particles from the air it takes in, that is the efficiency and amount of dust collection. By removing dust from the air, the air filter prevents the engine cylinder from wear, reduces ventilation resistance, and thus improves engine output and guarantees intake performance. In order to guarantee such air filter performance, it is very important to properly seal the air filter. For passenger cars made in Korea, the air filters are fabricated with steel caps as their frames are large and their engine capacity is big. Recently however, European countries and Japan started using urethane for manufacturing the air filter, so that all foreign-made cars now have urethane filters. The urethanes used for air filters are applied in two ways: One is to use soft urethane for both top and bottom of the air filter and the other is to use soft urethane for the top and hard urethane for the bottom. Each of these method has unique problems. In this study, hard urethane is used for both top and bottom of the filter in order to improve those problems and increase the sealing efficiency. Especially for the top, NBR (rubber mold) is pre-settled in tough urethane and then the urethane is solidified through foaming, which makes it possible to develop a solid and double-sealed filter.

  • PDF

사이클론-백 하이브리드형 집진장치에서 유동연결부 설계조건에 따른 유동균일성 전산해석 (CFD Analysis on the Flow in the Connection Duct of the Cyclone-Bag Hybrid Dust Collector)

  • 구성모;오원철;장혁상
    • 한국입자에어로졸학회지
    • /
    • 제12권4호
    • /
    • pp.115-126
    • /
    • 2016
  • Numerical analysis was done to evaluate the movement of the particles and the fluid inside of the cyclone-bag hybrid dust collector. Flow discharged from the cyclone in the hybrid particle collector has swirl pattern, and it results in the biased flow to the bag filters and deteriorates the collection performance of the bag filter. The current study is to evaluate the effect of the duct lengths and the baffle arrays in the connection duct by the computational methods. Main concerns of the analysis are how to improve the uniformity of the internal flow between the cyclone and the bag filter. Numerical analysis was done to check the particle removal efficiencies of the system with respect to the flow characteristics which is expressed in RMS values of the upward flow inside of the connection duct. The flow pattern inside of the connection duct is evaluated under different the duct lengths and the baffle arrays. In case of the reference geometry the RMS value of inside flow was 56.7%, and the value was decreased to 30.1% by controlling the lengths of duct. The effects of baffle was also evaluated, the RMS value of flow could be decreased 55.2% and so on. But the pressure drop across the baffles becomes high and the system efficiency becomes lower.

패시브 공동주택 계획을 위한 설계 중점항목 및 관련 기준 연구 (A Study of Critical Items and Related Standards on Designing for Passive Apartments)

  • 이명주
    • 대한건축학회논문집:계획계
    • /
    • 제34권7호
    • /
    • pp.21-29
    • /
    • 2018
  • This study aimed to find and suggest the purpose of future plans, critical items on designing and Related standards to amend construction standards for domestic energy saving and environmentally friendly housings. It would also activate and increase the supplies of passive house minimizing the problems on current apartment housings in winter and reducing heating energy which brings fine dust pollution. After defining the standard model of Korean apartment housings(reference model), this study calculated the amount of heating energy demand per unit area annually as applying the yearly changed standards from 2008 to 2017 to existing standard model. It turned out that applying 2017 construction standards of energy saving and eco-friendly housings to reference model has saved up to 75% of heating energy demand comparing to the one applied 2008's. However, it still could not solve the fundamental problems such as winter fungus, condensation, freezing, freeze and burst, and insulation weakness space, and could not be free from fine dust particles. To solve them, this study suggested improved standards adding critical items on design related to outside insulation, cut off the heat-bridge, enforce air-tightness and heat change efficiency on heat recovery ventilator. As a result, it has reduced more than 10% of heat demand from 2017. It would be more than 90% of savings from 2008 if we make the amount of heat loss be zero on heat bridge on designing stage in the future.

미세입자, 휘발성유기화합물 차단을 위한 전기방사 창문 필터 (Development of Window Filters Using an Electrospinning Technique to Block Particulate Matter and Volatile Organic Compound)

  • 김순호;한상일
    • Korean Chemical Engineering Research
    • /
    • 제61권3호
    • /
    • pp.401-406
    • /
    • 2023
  • 산업이 발달함에 따라 미세먼지는 환경, 건강, 생활 등 다양한 분야에서 문제를 일으키고 있으며, 특히 대기오염에 의해 발생되는 미세먼지는 심각한 환경문제로 대두되고 있다. 따라서 본 연구에서는 전기방사 기술을 적용하여 실리콘 지지체에 셀룰로스아세테이트 고분자 섬유를 방사하여 미세입자를 차단하고, 활성탄 입자를 첨가하여 휘발성유기 화합물을 제거하고자 하였다. 활성탄 비율과 전기방사 시간을 달리하여 활성탄 비율, 필터 두께에 따른 미세먼지 차단효과, 톨루엔 흡착 성능을 분석하였다. 그 결과 전기방사시간이 증가함에 따라 1~3 ㎛ 크기의 입자가 효과적으로 차단되었으며, 활성탄의 양이 0%에서 5%로 증가함에 따라 톨루엔 흡착량이 증가하는 것으로 나타났다. 전기방사 시간이 길어질 경우 필터 두께 증가로 인해 빛 투과가 현저히 떨어졌으며, 20~30분 전기방사한 필터의 경우 빛이 투과하여 창문 필터 적용 가능성을 보여주었다.

화재 및 호흡조건 변화에 따른 연기입자의 인체 호흡기 내 영역별 침착량 분석 (Study on the Regional Deposition of Smoke Particles in Human Respiratory Tract under the Variation of Fire and Breathing Conditions)

  • 구재학
    • 한국화재소방학회논문지
    • /
    • 제33권6호
    • /
    • pp.95-104
    • /
    • 2019
  • 화재 시 발생하는 연기는 가스상 물질과 이들을 흡착한 미연탄소 등의 입자상 물질로 이루어져 있다. 연기 중 가스상 물질의 흡입에 의한 인체피해는 대부분 단기적으로 이루어지는 데 비하여 입자상 물질의 흡입에 의한 피해는 가스상의 흡착상태에 따라서 상대적으로 장기적으로 이루어진다. 입자상 물질이 호흡기벽에 침착하여 호흡기 및 순환기 계통에 영향을 미치는 것과 관련하여, 침착되는 연기입자의 양과 호흡기 내 침착위치는 인체피해 산정의 중요한 요소인데, 이들은 연소조건에 영향을 받는 크기 및 농도 등 입자상태와 함께 호흡조건에 영향을 받는다. 이 연구에서는 화재 시 발생하는 연기의 흡입에 의한 인체피해 연구와 관련된 호흡기 내 연기입자 침착특성 파악을 위하여 연료종류, 연소조건 및 호흡조건에 따라 호흡기 내 영역별로 침착되는 연기입자의 입경에 따른 개수 및 질량 농도를 구하였다. 또한 각 조건별로 흡입연기의 일정기간 동안 호흡기 내 질량 침착량을 대기환경 미세먼지 기준치와 비교 분석하였다.

강하분진의 침적 특성파악을 위한 통계학적 해석과 공간분포 분석 (A Statistical Analysis and Spatial Distribution Analysis for Deposition Characteristics of Fall-out Particles)

  • 주재희;황인조
    • 한국대기환경학회지
    • /
    • 제28권3호
    • /
    • pp.294-305
    • /
    • 2012
  • The objective of this study is to estimate the chemical compositions and to identify qualitative sources of fall-out particles in study area. Also, this study used a spatial analysis to estimate spatial distributions and average deposition flux. In this study, the chemical compositions of fall-out particle samples collected at Muncheon lake from May 2010 to January 2011 were analyzed by ICP and IC. The monthly trend of deposition fluxes for fall-out particles showed highest in June ($107.61kg/km^2/day$) and lowest in October ($22.22kg/km^2/day$). The average fluxes of Fe, Si, Al, Zn and Ba are 0.44, 0.24, 0.20, 0.17, $0.09kg/km^2/day$, respectively. Also, the average fluxes of $NO_3^-$, $SO_4^{2-}$, $NH_4^+$, $Ca^{2+}$, and $Na^+$ are 6.48, 5.01, 4.96, 1.75, $1.37kg/km^2/day$, respectively. A Factor analysis identified four sources such as 1) nonferrous metal, motor vehicle, and agriculture, 2) soil, 3) field burning, incineration, and 4) road dust and oil burning. The IDW (inverse distance weighting) spatial analysis method was used to estimate spatial distribution and average deposition flux for fall-out particles. A total average deposition fluxes estimated in Muncheon lake were 936.15 kg/month. The spatial distribution trend of deposition flux showed higher at site 1 and 2 than at site 3, 4 because local road is adjacent to the site 1 and 2.

와이어-실린더형 습식 전기집진기의 수막 유무에 따른 집진 특성 비교 (Comparison of particle collection characteristics in a wire-cylindrical wet electrostatic precipitator with and without a water film)

  • 우창규;조원기;김학준;김용진;한방우
    • 한국입자에어로졸학회지
    • /
    • 제14권4호
    • /
    • pp.89-95
    • /
    • 2018
  • People's environmental concerns for fine particles in Korea lead to the strong necessity of improving the performance of environmental control systems. Wet electrostatic precipitators (ESPs) are considered as one of the alternatives to overcome the limit of previous dry ESPs, the re-entrainment of collected particles during rapping and back corona problem for high electrical resistivity dusts etc. In this study, a wire-cylindrical ESP with a thin water film has been developed. Particle collection characteristics were compared in the ESP with operations of water film on and off. Particle collection efficiencies at various applied voltages as well as voltage-current curves were almost the same in the ESP with and without a water film. Particle collection performance for PM1.0, PM2.5 and PM10 in the wet ESP with a water film was constantly maintained with operation time even in the high dust loading environment. This results indicate that a uniform water film in our wet ESP was successfully formed with a very thin layer without any dry spot and therefore could continuously clean the collected particles on the inner wall of the ESP without any performance degradation.

골재 중 0.08 mm 이하 미립분의 종류가 콘크리트의 특성에 미치는 영향 (The Influence of Fine Particles under 0.08 mm Contained in Aggregate on the Characteristics of Concrete)

  • 송진우;최재진
    • 콘크리트학회논문집
    • /
    • 제25권3호
    • /
    • pp.347-354
    • /
    • 2013
  • 최근 천연모래의 부족으로 부순 잔골재가 널리 사용되고 있다. 우리나라에서는 부순 잔골재 중의 0.08 mm 이하 미립분을 7% 이하로 제한하고 있으며 이는 ASTM의 규정과 유사한 것이나 그 외의 다른 나라의 규정과 비교할 때 상당히 엄격한 규정이다. 또한 부순 잔골재 중에는 파쇄 시에 발생하는 0.08 mm 이하 미립분을 20% 정도 포함하게 되며 물로 씻어내는 일도 용이하지 않을 뿐 아니라 자원이용의 극대화를 위해서도 잔입자량 한도의 상향 조정 가능 여부에 대한 검토가 필요하다. 그래서 이 연구에서는 0.08 mm 이하 미립분에 대한 특성 및 콘크리트 품질에 미치는 영향에 대한 실험을 실시하였으며, 비교를 위하여 실트 및 점성토 중의 미립분을 사용한 실험을 병행하였다. 미립분에 대해 실험한 결과 메틸렌블루 값은 부순 잔골재 중의 석분에 비하여 실트 및 점성토 중의 미립분에 대한 값이 보다 크게 나타났으며 또한 메틸렌블루 값은 packing density 및 액성한계, 소성한계와 높은 상관관계를 가지는 것으로 나타났다. 콘크리트 실험에서 동일한 슬럼프를 얻기 위한 고성능 감수제의 소요량은 미립분의 대체 사용량 증가에 따라 커지며, 메틸렌블루 값이 큰 미립분을 사용할 때 보다 크게 나타났다. 한편 부순 잔골재 중의 미립분을 20% 이내에서 대체 사용한 경우, 고성능감수제를 사용하여 반죽질기를 같게 한 콘크리트의 압축강도와 인장강도는 거의 변화가 없었으며 콘크리트의 건조수축량도 큰 차이를 보이지 않았다. 그러나 실트 및 점성토 중의 미립분을 대체 사용한 경우는 콘크리트의 강도가 현저히 저하하고 건조수축량도 크게 증가하는 것으로 나타났다.