• Title/Summary/Keyword: Dust Loading Rate

Search Result 10, Processing Time 0.018 seconds

A Study on Fine Particle Removal of ESP according to $(NH_4)_2SO_4$ Injection Rate (황산암모늄 주입에 따른 전기집진기(ESP)에서의 미세분진 제거)

  • 서정민
    • Journal of Environmental Science International
    • /
    • v.7 no.4
    • /
    • pp.505-510
    • /
    • 1998
  • This study has been carried out to investigate Electrostatic Precipitator's(ESP) performance enhancement and removal efficiency of fine particle according to (NH4)2SO4injection rate. The following conclusions are derived from the these test results : 1) For plant condition cases, according to the variation of concentration agent [(NH4)2SO4]-10ppm, when inlet dust loading was 2g/m2. And when Inlet dust loading was 3g/m", that was increased to 98 19% 99.16% 99.23%, 99.58%, 2) It Is seen from thins experiments that the increasing 30ppm concentration of (NH4)2SO4 increase the collection efficiency and fine particle omission control.

  • PDF

Optimal Distance between Positive and Negative Electrode-Plates Coated with Activated Carbon in Dust Removal Chamber (활성탄전극을 이용한 분진제거에서 전극의 적정 간격에 관한 연구)

  • Kim, Kwang Soo;Park, Hyun Chul;Jun, Tae Hwan;Lee, Ju Haeng;Nam, Sang Chul
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.11
    • /
    • pp.821-826
    • /
    • 2013
  • The purposes of this research are to study on optimal distance between positive and negative electrodes in dust removal chamber. The experiments were performed with electrode-plate gab arranging in order of 3 cm, 2 cm, 1 cm in series while varying influent flow-rate. From the experimental results of dust removal the optimal influent linear velocity was 6 cm/sec and the total mass of attached dust on the surface of electrode-plate was increased as electrode-plate gab is closer. But in case of electrode-plate gab being very close about 1 cm or so, the attached dust on the surface of electrode-plate was shown releasing from electrode-plate due to dust electric-charge changing (reverse ionization). Evantually. optimal distance between positive and negative electrode-plates was about 2 cm and also optimal dust loading rate was about $24mg/min{\cdot}m^2$.

A Study on Filtration Performance Test with Electrostatically Enhanced Fabric Filter (정전형여과집진방식에서 여과특성에 관한 연구)

  • 천중국;박출재;최금찬
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.11 no.4
    • /
    • pp.361-367
    • /
    • 1995
  • This study has been carried out to investigate the filteration performance of Electrostatically Stimulated Fabric Filter(ESFF) at high temperature condition. The electric field was maintained parallel to the fabric surface. The benefits of ESFF are lower residual pressure drop, improvement of fine particle removal efficiency and increasing reduced rate of pressure drop during a filteration cycle, stable operation at higher filtering velocities. According to the variance of filtering velocities and dust loadings, the results are summarized as follows; By imposing an electric field on the filter, the reduced rate of pressure drop was 7.sim.18% at room temperature, and when filtering velocity was 1.8m/min and dust loading was 1g/m$^{3}$, the value of reduced rate of pressure drop was shown the highest. Under the electric field around the filter, the reduced rate of pressure drop was 10.sim.35% at high temperature, and when filtering velocity was 1.8m/min and dust loading was 1g/m$^{3}$, the value of reduced rate of pressure drop was shown the highest. Most of all, at high temperature, the value of reduced rate of pressure drop was resulted to 25%. Also the collecting efficiency was shown clearly improved. By the SEM photo analysis, the number of penetrated particles at the Conventional Fabric Filter was approximately two times that of Electrostatically Stimulated Fabric Filter.

  • PDF

Performance Comparison of a Fabric Filter System with Centrifugal Force and a Conventional Fabric Filter System (원심력이 적용된 여과포집진장치와 기존 집진장치의 성능비교)

  • Kim Sang-Do;Park Young-Ok;Kang Yong
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.6
    • /
    • pp.739-748
    • /
    • 2004
  • A hybrid dust-collector combining a fabric filter with centrifugal force was developed to enhance the performance of the conventional fabric filter systems and its performances were evaluated to compare to that of the existing dust collector. The pressure drop rapidly increased with increasing the elapsed time and the face velocity in two filtration systems. But the increasing ratio of a hybrid dust-collector compare to the existing dust collector was lower. This results were confirmed from the performance such as cleaning interval, residual pressure drop and dust loading rate. The overall collection efficiency of the hybrid dust-collector was more than 99.6% and this showed a improvement of 0.6~2% than that of the existing dust collector. Especially, the fractional collection efficiency at the particle size of around 1${\mu}{\textrm}{m}$ is about 4% higher than that of the existing dust collector.

Evaluation of Environmental Benefit and Cost for Management of Air Quality - [Based on Fine Dust Pollution on Donghae Harbor] (공기질 관리에 관한 환경 비용편익 연구[동해항만 주변 미세먼지오염을 기준])

  • Kim, Eun-Joo;Lee, Choon-Gil;Kim, Ji-Hyun;Park, Young-Koo
    • Journal of the Korean Applied Science and Technology
    • /
    • v.29 no.4
    • /
    • pp.561-569
    • /
    • 2012
  • Study attempts to evaluate the environmental cost and benefit for management of particulate matters of Donghae harbor in Gangwondo. The level of fine dust suspended in the vicinity of the harbor was quite high, exceeding the national standard ($100{\mu}g/m^3$) depending on the places. The test field harbor deals with lots of limestone and coal, so that fine particulates could be generated while loading it and unloading. It was estimated that the direct handling of cargos might produce 12 tons of PM10(Particulate Matters of $10{\mu}m$) a year. In addition, heavy vehicles for transportation of various cargos including raw materials emit huge amount of diesel soots and cause to redispersion of road dust. The local government spends more than 2 billion won every year, and it contributes to reduce the atmospheric dust. According to the prediction of cost to benefit, it will present the effectiveness in 720 % maximum and at least 240 %.

Study on Rate-Limiting Factors with a Heavy Loaded Biofilter

  • Son, Hyun-Keun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.23 no.E2
    • /
    • pp.74-81
    • /
    • 2007
  • Feasibility test for a biofilter was performed to treat VOCs. The applied loading rate to the biofilter was calculated between 60 to $3,700\;kg\;COD/m^3$. Trimethyl-pentene and trimethyl-hexene were the two most dominant compounds and they occupy about 85 percent. During the acclimation period, it is desirable for a biofilter to receive relatively lower VOCs concentration and flow rate, until it can adjust to new substrate and operational environment. Temperature at various points inside the biofilter reactor was observed with more than 23 temperature sensors. With steam heating, temperatures of the top sections of the media were greater than those of bottom sections. Without steam heating, intermediate stages generally had higher temperature measurement than those of bottom and top stages. Because the pH values for different biofilter materials vary significantly, measurement of the pH for the mixture of different combinations of biofilter materials is necessary. Based on the types and brands of media, the measured pH ranged from 5.38 to 9.10. The range of measured pH of different mixtures with perlite, compost, saw dust, peat moss, limestone, vermiculite was 7.05 to 8.62.

A Study on Bulk Deposition Flux of Dustfall and Insoluble Components in Pusan, Korea (부산지역 강하먼지와 불용성 성분의 침적량에 관한 연구)

  • 김유근;박종길;문덕환;황용식
    • Journal of Environmental Science International
    • /
    • v.10 no.3
    • /
    • pp.209-216
    • /
    • 2001
  • Dustfall particles were collected by the modified American dust jar (wide inlet bottle type) at 6 sampling sites in Pusan area from March, 1999 to February, 2000. Thirteen chemical species (Al, Ca, Cd, Cr, Cu, Fe, K, Mg, Mn, Ni, Pb, Si, and Zn) were analyzed by AAS and ICP. The purposes of this study were to estimate qualitatively various bulk deposition flux of dustfall and insoluble components by applying regional and seasonal distribution. Dustfall amount of regional variations were found in order of coastal zone, industrial zone, commercial zone, agricultural zone and residential zone, and seasonal total dustfall had higher concentrations during spring for 6.741 ton/${km}^2$/season, lower concentrations during summer for 1.989 ton/${km}^2$/season, and annual total concentration was 17.742 ton/${km}^2$/year. The regional distributions of enrichment factor show well-defined anthropogenic metals (Cd, Cu, Pb, and Zn) at industrial and agricultural zone, and contribution rate of soil particles were found in order of summer, fall, winter and spring. Factor loading effects of chemical composition of dustfall were found in order of road traffic emission source and combustion processed source, industrial activity source, soil source and marine source.

  • PDF

Occupational Tasks Influencing Lung Function and Respiratory Symptoms Among Charcoal-Production Workers: A Time-Series Study

  • Pramchoo, Walaiporn;Geater, Alan F.;Jamulitrat, Silom;Geater, Sarayut L.;Tangtrakulwanich, Boonsin
    • Safety and Health at Work
    • /
    • v.8 no.3
    • /
    • pp.250-257
    • /
    • 2017
  • Background: Tasks involved in traditional charcoal production expose workers to various levels of charcoal dust and wood smoke. This study aimed to identify specific tasks influencing lung function and respiratory symptoms. Methods: Interviews, direct observation, and task/symptom checklists were used to collect data from 50 charcoal-production workers on 3 nonwork days followed by 11 workdays. The peak expiratory flow rate (PEFR) was measured four times per day. Results: The PEFR was reduced and the prevalence of respiratory symptoms increased over the first 6-7 workdays. The PEFR increased until evening on nonwork days but not on workdays. Loading the kiln and collecting charcoal from within the kiln markedly reduced the PEFR and increased the odds of respiratory symptoms. Conclusion: Tasks involving entry into the kiln were strongly associated with a short-term drop in the PEFR and the occurrence of respiratory symptoms, suggesting a need for the use of protective equipment and/or the operation of an effective kiln ventilation system.

Columnar Aerosol Properties at Yongin According to Transport Paths of Back Trajectories (역궤적 이동경로별 용인지역의 컬럼에어로졸 특성)

  • Park, Jisoo;Choi, Yongjoo;Ghim, Young Sung
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.33 no.2
    • /
    • pp.97-107
    • /
    • 2017
  • Columnar aerosol properties retrieved from solar radiation were investigated at the Yongin (YGN) SKYNET site over seven years from October 2008 to October 2015. Hourly averages were calculated when the data were available, and back trajectories were calculated to examine the effects of regional transport. Data recovery rate was low at 6.6%, primarily because solar radiation was measured only under daytime clear-sky conditions. Mean values of the fine-mode volume fraction (FMVF) as well as its seasonal variation were similar to those of $PM_{2.5}/PM_{10}$ although the coarse-mode fraction of column aerosols tended to be slightly larger. The values of single scattering albedo (SSA) and FMVF were lower in spring due to the effects of mineral dust, and higher in summer due to secondarily-formed inorganic ions. Back trajectories were grouped into five clusters according to the directions of transport paths. Aerosol loading was highest for Cluster 2 from the northwest, but SSA and FMVF were not particularly high or low because aerosols were composed of various materials with different properties. Aerosol loading was lowest for Cluster 5 from the Pacific Ocean passing through the south end of Japan, whose SSA and FMVF were highest as secondarily-formed inorganic ions were mixed.

Risk Factors for Associated with Latent Tuberculosis Infection among Former Mine Workers (광업 이직근로자에서 잠복결핵감염 위험요인 분석)

  • Hwang, Joo Hwan;Shin, Jae Hoon;Baek, JinEe;Choi, Byung-Soon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.29 no.3
    • /
    • pp.289-297
    • /
    • 2019
  • Objectives: To identify the positive rate of and the risk factors associated with latent tuberculosis infection(LTBI) in mine workers, the objectives of the present study evaluated those among former mine workers. Methods: Between January 2015 and May 2017, former male mine workers who had been subjects for epidemiology research for work-related chronic obstructive pulmonary disease(COPD) and had received QuantiFERON-$TB^{(R)}$ Gold In-Tube(QFT-GIT) from the Institute of Occupation and Environment(IOE) under Korea Workers' Compensation and Welfare Service(KCOMWEL) were selected as the study subjects. To identify significant variables for increased risk of LTBI, logistic regression analysis was performed. Results: A total of 736 male former mine workers were selected as study subjects. The positive rate of LTBI among subjects was 69.2%(509/736). The current smoking[odds ratio(OR), 2.3; 95% confidence interval(CI), 1.1-4.9], COPD(OR, 1.4; 95% CI, 0.9-2.3), department loading(OR, 1.8; 95% CI, 0.9-3.4) and mining(OR, 1.5; 95% CI, 0.9-2.5), and working duration of over 20(OR, 1.6; 95% CI, 0.9-3.1) and over 30 years(OR, 2.2; 95% CI, 0.9-4.9) were associated with increased risk of LTBI. The interferon-gamma(IFN-${\gamma}$) level after stimulation with Mycobacterium tuberculosis(MTB)-specific antigens showed a significantly negative correlation with age(r=-0.126). Conclusions: The present study determined that the high positive rate of LTBI among mine workers was associated with not only the host factors but also the occupational exposure to mine dust.