황산암모늄 주입에 따른 전기집진기(ESP)에서의 미세분진 제거 (A Study on Fine Particle Removal of ESP according to $(NH_4)_2SO_4$ Injection Rate)

  • 서정민
    • 한국환경과학회지
    • /
    • 제7권4호
    • /
    • pp.505-510
    • /
    • 1998
  • This study has been carried out to investigate Electrostatic Precipitator's(ESP) performance enhancement and removal efficiency of fine particle according to (NH4)2SO4injection rate. The following conclusions are derived from the these test results : 1) For plant condition cases, according to the variation of concentration agent [(NH4)2SO4]-10ppm, when inlet dust loading was 2g/m2. And when Inlet dust loading was 3g/m", that was increased to 98 19% 99.16% 99.23%, 99.58%, 2) It Is seen from thins experiments that the increasing 30ppm concentration of (NH4)2SO4 increase the collection efficiency and fine particle omission control.

  • PDF

활성탄전극을 이용한 분진제거에서 전극의 적정 간격에 관한 연구 (Optimal Distance between Positive and Negative Electrode-Plates Coated with Activated Carbon in Dust Removal Chamber)

  • 김광수;박현철;전태환;이주행;남상철
    • 대한환경공학회지
    • /
    • 제35권11호
    • /
    • pp.821-826
    • /
    • 2013
  • 본 연구의 목적은 분진제거 장치에서 전극간의 적정간격을 알아보기 위한 것이다. 실험은 전극간격을 3 cm, 2 cm, 1 cm로 직렬로 놓고 유입유량을 변화시켜 수행하였다. 실험결과로부터 분진제거를 위한 적정 선속도는 6 cm/sec였고 전극표면에 부착되는 분진 총량은 전극의 간격이 가까울수록 증가하였다. 그러나 1 cm 정도로 매우 가까울 경우는 전극판에 부착된 분진은 탈착되었으며 이는 분착된 분진의 역이온화 즉 전하의 변화 때문인 것으로 사료되었다. 결과적으로 전극판에서 양전극과 음전극 간의 간격은 2 cm가 적당하고 이때의 분진부하율은 $24mg/min{\cdot}m^2$였다.

정전형여과집진방식에서 여과특성에 관한 연구 (A Study on Filtration Performance Test with Electrostatically Enhanced Fabric Filter)

  • 천중국;박출재;최금찬
    • 한국대기환경학회지
    • /
    • 제11권4호
    • /
    • pp.361-367
    • /
    • 1995
  • This study has been carried out to investigate the filteration performance of Electrostatically Stimulated Fabric Filter(ESFF) at high temperature condition. The electric field was maintained parallel to the fabric surface. The benefits of ESFF are lower residual pressure drop, improvement of fine particle removal efficiency and increasing reduced rate of pressure drop during a filteration cycle, stable operation at higher filtering velocities. According to the variance of filtering velocities and dust loadings, the results are summarized as follows; By imposing an electric field on the filter, the reduced rate of pressure drop was 7.sim.18% at room temperature, and when filtering velocity was 1.8m/min and dust loading was 1g/m$^{3}$, the value of reduced rate of pressure drop was shown the highest. Under the electric field around the filter, the reduced rate of pressure drop was 10.sim.35% at high temperature, and when filtering velocity was 1.8m/min and dust loading was 1g/m$^{3}$, the value of reduced rate of pressure drop was shown the highest. Most of all, at high temperature, the value of reduced rate of pressure drop was resulted to 25%. Also the collecting efficiency was shown clearly improved. By the SEM photo analysis, the number of penetrated particles at the Conventional Fabric Filter was approximately two times that of Electrostatically Stimulated Fabric Filter.

  • PDF

원심력이 적용된 여과포집진장치와 기존 집진장치의 성능비교 (Performance Comparison of a Fabric Filter System with Centrifugal Force and a Conventional Fabric Filter System)

  • 김상도;박영옥;강용
    • 한국대기환경학회지
    • /
    • 제20권6호
    • /
    • pp.739-748
    • /
    • 2004
  • A hybrid dust-collector combining a fabric filter with centrifugal force was developed to enhance the performance of the conventional fabric filter systems and its performances were evaluated to compare to that of the existing dust collector. The pressure drop rapidly increased with increasing the elapsed time and the face velocity in two filtration systems. But the increasing ratio of a hybrid dust-collector compare to the existing dust collector was lower. This results were confirmed from the performance such as cleaning interval, residual pressure drop and dust loading rate. The overall collection efficiency of the hybrid dust-collector was more than 99.6% and this showed a improvement of 0.6~2% than that of the existing dust collector. Especially, the fractional collection efficiency at the particle size of around 1${\mu}{\textrm}{m}$ is about 4% higher than that of the existing dust collector.

공기질 관리에 관한 환경 비용편익 연구[동해항만 주변 미세먼지오염을 기준] (Evaluation of Environmental Benefit and Cost for Management of Air Quality - [Based on Fine Dust Pollution on Donghae Harbor])

  • 김은주;이춘길;김지현;박영구
    • 한국응용과학기술학회지
    • /
    • 제29권4호
    • /
    • pp.561-569
    • /
    • 2012
  • 본 연구는 강원도 소재 동해항만에서 발생하는 미세먼지 관리를 위한 환경비용편익을 산출하는 것이다. 항구 인근에 부유하는 미세먼지의 농도는 매우 높은 편이며, 지점에 따라 국가 기준인 $100{\mu}g/m^3$ 이상으로 관측되는 곳도 있다. 시험대상 항구는 주로 석회석과 석탄을 취급함으로써 미세입자상 물질이 하역시 다량 발생한다. 연구결과 PM10을 기준으로 년간 12톤의 미세먼지가 하역작업 시 발생하는 것으로 밝혀졌다. 덧붙여서 원료물질을 비롯한 다양한 화물을 운송하는 대형차량 및 중장비는 디젤 검댕이를 발생하고, 도로먼지의 비산을 유발한다. 지방정부는 해마다 20억원 이상의 비용을 투자하여 대기중 미세먼지를 제거하고 있다. 편익대비 비용을 산출한 결과 그 효과는 최소 240%에서 최대 720%까지 얻을 수 있는 것으로 나타났다.

Study on Rate-Limiting Factors with a Heavy Loaded Biofilter

  • Son, Hyun-Keun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제23권E2호
    • /
    • pp.74-81
    • /
    • 2007
  • Feasibility test for a biofilter was performed to treat VOCs. The applied loading rate to the biofilter was calculated between 60 to $3,700\;kg\;COD/m^3$. Trimethyl-pentene and trimethyl-hexene were the two most dominant compounds and they occupy about 85 percent. During the acclimation period, it is desirable for a biofilter to receive relatively lower VOCs concentration and flow rate, until it can adjust to new substrate and operational environment. Temperature at various points inside the biofilter reactor was observed with more than 23 temperature sensors. With steam heating, temperatures of the top sections of the media were greater than those of bottom sections. Without steam heating, intermediate stages generally had higher temperature measurement than those of bottom and top stages. Because the pH values for different biofilter materials vary significantly, measurement of the pH for the mixture of different combinations of biofilter materials is necessary. Based on the types and brands of media, the measured pH ranged from 5.38 to 9.10. The range of measured pH of different mixtures with perlite, compost, saw dust, peat moss, limestone, vermiculite was 7.05 to 8.62.

부산지역 강하먼지와 불용성 성분의 침적량에 관한 연구 (A Study on Bulk Deposition Flux of Dustfall and Insoluble Components in Pusan, Korea)

  • 김유근;박종길;문덕환;황용식
    • 한국환경과학회지
    • /
    • 제10권3호
    • /
    • pp.209-216
    • /
    • 2001
  • Dustfall particles were collected by the modified American dust jar (wide inlet bottle type) at 6 sampling sites in Pusan area from March, 1999 to February, 2000. Thirteen chemical species (Al, Ca, Cd, Cr, Cu, Fe, K, Mg, Mn, Ni, Pb, Si, and Zn) were analyzed by AAS and ICP. The purposes of this study were to estimate qualitatively various bulk deposition flux of dustfall and insoluble components by applying regional and seasonal distribution. Dustfall amount of regional variations were found in order of coastal zone, industrial zone, commercial zone, agricultural zone and residential zone, and seasonal total dustfall had higher concentrations during spring for 6.741 ton/${km}^2$/season, lower concentrations during summer for 1.989 ton/${km}^2$/season, and annual total concentration was 17.742 ton/${km}^2$/year. The regional distributions of enrichment factor show well-defined anthropogenic metals (Cd, Cu, Pb, and Zn) at industrial and agricultural zone, and contribution rate of soil particles were found in order of summer, fall, winter and spring. Factor loading effects of chemical composition of dustfall were found in order of road traffic emission source and combustion processed source, industrial activity source, soil source and marine source.

  • PDF

Occupational Tasks Influencing Lung Function and Respiratory Symptoms Among Charcoal-Production Workers: A Time-Series Study

  • Pramchoo, Walaiporn;Geater, Alan F.;Jamulitrat, Silom;Geater, Sarayut L.;Tangtrakulwanich, Boonsin
    • Safety and Health at Work
    • /
    • 제8권3호
    • /
    • pp.250-257
    • /
    • 2017
  • Background: Tasks involved in traditional charcoal production expose workers to various levels of charcoal dust and wood smoke. This study aimed to identify specific tasks influencing lung function and respiratory symptoms. Methods: Interviews, direct observation, and task/symptom checklists were used to collect data from 50 charcoal-production workers on 3 nonwork days followed by 11 workdays. The peak expiratory flow rate (PEFR) was measured four times per day. Results: The PEFR was reduced and the prevalence of respiratory symptoms increased over the first 6-7 workdays. The PEFR increased until evening on nonwork days but not on workdays. Loading the kiln and collecting charcoal from within the kiln markedly reduced the PEFR and increased the odds of respiratory symptoms. Conclusion: Tasks involving entry into the kiln were strongly associated with a short-term drop in the PEFR and the occurrence of respiratory symptoms, suggesting a need for the use of protective equipment and/or the operation of an effective kiln ventilation system.

역궤적 이동경로별 용인지역의 컬럼에어로졸 특성 (Columnar Aerosol Properties at Yongin According to Transport Paths of Back Trajectories)

  • 박지수;최용주;김영성
    • 한국대기환경학회지
    • /
    • 제33권2호
    • /
    • pp.97-107
    • /
    • 2017
  • Columnar aerosol properties retrieved from solar radiation were investigated at the Yongin (YGN) SKYNET site over seven years from October 2008 to October 2015. Hourly averages were calculated when the data were available, and back trajectories were calculated to examine the effects of regional transport. Data recovery rate was low at 6.6%, primarily because solar radiation was measured only under daytime clear-sky conditions. Mean values of the fine-mode volume fraction (FMVF) as well as its seasonal variation were similar to those of $PM_{2.5}/PM_{10}$ although the coarse-mode fraction of column aerosols tended to be slightly larger. The values of single scattering albedo (SSA) and FMVF were lower in spring due to the effects of mineral dust, and higher in summer due to secondarily-formed inorganic ions. Back trajectories were grouped into five clusters according to the directions of transport paths. Aerosol loading was highest for Cluster 2 from the northwest, but SSA and FMVF were not particularly high or low because aerosols were composed of various materials with different properties. Aerosol loading was lowest for Cluster 5 from the Pacific Ocean passing through the south end of Japan, whose SSA and FMVF were highest as secondarily-formed inorganic ions were mixed.

광업 이직근로자에서 잠복결핵감염 위험요인 분석 (Risk Factors for Associated with Latent Tuberculosis Infection among Former Mine Workers)

  • 황주환;신재훈;백진이;최병순
    • 한국산업보건학회지
    • /
    • 제29권3호
    • /
    • pp.289-297
    • /
    • 2019
  • Objectives: To identify the positive rate of and the risk factors associated with latent tuberculosis infection(LTBI) in mine workers, the objectives of the present study evaluated those among former mine workers. Methods: Between January 2015 and May 2017, former male mine workers who had been subjects for epidemiology research for work-related chronic obstructive pulmonary disease(COPD) and had received QuantiFERON-$TB^{(R)}$ Gold In-Tube(QFT-GIT) from the Institute of Occupation and Environment(IOE) under Korea Workers' Compensation and Welfare Service(KCOMWEL) were selected as the study subjects. To identify significant variables for increased risk of LTBI, logistic regression analysis was performed. Results: A total of 736 male former mine workers were selected as study subjects. The positive rate of LTBI among subjects was 69.2%(509/736). The current smoking[odds ratio(OR), 2.3; 95% confidence interval(CI), 1.1-4.9], COPD(OR, 1.4; 95% CI, 0.9-2.3), department loading(OR, 1.8; 95% CI, 0.9-3.4) and mining(OR, 1.5; 95% CI, 0.9-2.5), and working duration of over 20(OR, 1.6; 95% CI, 0.9-3.1) and over 30 years(OR, 2.2; 95% CI, 0.9-4.9) were associated with increased risk of LTBI. The interferon-gamma(IFN-${\gamma}$) level after stimulation with Mycobacterium tuberculosis(MTB)-specific antigens showed a significantly negative correlation with age(r=-0.126). Conclusions: The present study determined that the high positive rate of LTBI among mine workers was associated with not only the host factors but also the occupational exposure to mine dust.