• Title/Summary/Keyword: Dust Analysis

Search Result 944, Processing Time 0.026 seconds

Decomposition Characteristics of Non-Degradable Liquid Waste under High Temperature and High Pressure Conditions (고온 고압 조건에서의 난분해성 액상폐기물 분해 특성)

  • Lee, Gang-Woo;Shon, Byung-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.6
    • /
    • pp.1572-1578
    • /
    • 2007
  • The specified wastes consist of waste acid, waste alkali, waste oil, waste organic solvent, waste resin, dust, sludge, infectious waste, and others. Among these specified wastes, a great portion is liquid phase wastes. The purpose of this study is to develop the high temperature and high pressure (HTHP) treatment system for decomposition of the liquid phase specified waste (LPSW). For this, we analyzed the physical and chemical properties of the LPSW such as density, proximate analysis, ultimate analysis, heating values, and designed 0.3 ton/day HTHP treatment system. The LPSW tested in this experiment were prepared by adding TCE(trichloroethylene) and toluene to liquid phase waste which was brought into the commercial waste treatment company. The average density of waste oil (25 samples), waste resin (5 samples), and waste solvent (12 samples) was 0.99 g/mL, 0.91 g/mL, and 0.93 g/mL, respectively. And the average lower heating value of waste oil, waste resin, and waste solvent was 8,294 kcal/kg, 5,809 kcal/kg, and 7,462 kcal/kg, respectively. The DRE (Destruction & Removal Efficiency) of TCE and toluene were 99.95% and 99.73% at atmospheric pressure conditions and that were 99.99% and 99.82% at pressurized conditions, respectively. These results showed that TCE/toluene mixtures were properly decomposed over about 99.73% of DRE by the HTHP treatment system and pressurized conditions were more effective to destroy those pollutants than atmospheric pressure conditions. Also these systems could be directly applied to industries which try to treat the liquid phase specified waste within the regulation limit.

  • PDF

Particulate Matter and CO2 Improvement Effects by Vegetation-based Bio-filters and the Indoor Comfort Index Analysis (식생기반 바이오필터의 미세먼지, 이산화탄소 개선효과와 실내쾌적지수 분석)

  • Kim, Tae-Han;Choi, Boo-Hun;Choi, Na-Hyun;Jang, Eun-Suk
    • Korean Journal of Environmental Agriculture
    • /
    • v.37 no.4
    • /
    • pp.268-276
    • /
    • 2018
  • BACKGROUND: In the month of January 2018, fine dust alerts and warnings were issued 36 times for $PM_{10}$ and 81 times for PM2.5. Air quality is becoming a serious issue nation-wide. Although interest in air-purifying plants is growing due to the controversy over the risk of chemical substances of regular air-purifying solutions, industrial spread of the plants has been limited due to their efficiency in air-conditioning perspective. METHODS AND RESULTS: This study aims to propose a vegetation-based bio-filter system that can assure total indoor air volume for the efficient application of air-purifying plants. In order to evaluate the quantitative performance of the system, time-series analysis was conducted on air-conditioning performance, indoor air quality, and comfort index improvement effects in a lecture room-style laboratory with 16 persons present in the room. The system provided 4.24 ACH ventilation rate and reduced indoor temperature by $1.6^{\circ}C$ and black bulb temperature by $1.0^{\circ}C$. Relative humidity increased by 24.4% and deteriorated comfort index. However, this seemed to be offset by turbulent flow created from the operation of air blowers. While $PM_{10}$ was reduced by 39.5% to $22.11{\mu}g/m^3$, $CO_2$ increased up to 1,329ppm. It is interpreted that released $CO_2$ could not be processed because light compensation point was not reached. As for the indoor comfort index, PMV was reduced by 83.6 % and PPD was reduced by 47.0% on average, indicating that indoor space in a comfort range could be created by operating vegetation-based bio-filters. CONCLUSION: The study confirmed that the vegetation-based bio-filter system is effective in lowering indoor temperature and $PM_{10}$ and has positive effects on creating comfortable indoor space in terms of PMV and PPD.

Effects of Physical Factors on Urban Surfaces on Air Quality - Chang Chun, China as an Example - (도시표면의 물리적 요소가 대기질에 미치는 영향 - 중국 창춘을 사례로 -)

  • Jin, Quanping;Kim, Tae Kyung
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.49 no.5
    • /
    • pp.1-11
    • /
    • 2021
  • The purpose of this study is to find out the main factors affecting air quality in urban physical space factors, and provide clues for environmental improvement. Nine monitoring stations in China's industrial city, Changchun, collected AQI concentration data from January 1, 2018 to December 31, 2019. This paper analyzes the types and distribution characteristics of urban physical facilities within a radius of 300m with the detection station as the center. The monitoring station is divided into three groups, and the difference in floating dust concentration among the three groups in different seasons is analyzed. The results show that AQI concentration is the highest in spring and winter, followed by summer, and the lowest in autumn. The place with the highest concentrations of AQI in spring are F (93.00), D (91.10), I (89.20), in summer are D (69.05), A (67.89), B (84.44), in autumn are I (62.80), G (60.84), D (53.27), D (53.27), in winter are I (95.82), H (95.60), f (94.04). Through SPSS analysis, it shows that the air index in a space with a diameter of 600 meters is related to forest land, grassland, bare land, water space, tree height, building area (average value), and building volume (average value). According to the statistical analysis results of spring and winter with the most serious pollution, forest land area (43,637m2, 15.44%) and water surface area (18,736m2, 6.63%) accounted for the majority, and group 1 (A, B, C) with the least average building area (448m2, 0.17%) and average building volume (10,201m2) had the lowest pollution concentration. On the contrary, group 2 (D, E, F) had the highest AQI concentration, with less or no woodland (1,917m2, 0.68%) and water surface area (0m2, 0%), and the highest average building area (1,056m2, 0.37%) and average building volume (17,470m3). It is confirmed that the characteristics of the area with the highest AQI concentration are that the more the site ratio of tree height above 12m, the smaller the site ratio of bare land, and the lower the pollution degree. On the contrary, the larger the area of bare land, the higher the pollution degree. By analyzing the characteristics of nine monitoring stations in Changchun, it can be seen that the air quality brought by the physical characteristics of urban space is closely related to the above factors.

The Effect of Pleural Thickening on the Impairment of Pulmonary Function in Asbestos Exposed Workers (석면취급 근로자에서 늑막비후가 폐기능에 미치는 영향)

  • Kim, Jee-Won;Ahn, Hyeong-Sook;Kim, Kyung-Ah;Lim, Young;Yun, Im-Goung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.6
    • /
    • pp.923-933
    • /
    • 1995
  • Background: Pleural abnormality is the the most common respiratory change caused by asbestos dust inhalation and also develop other asbestos related disease after cessation of asbestos exposure. So we conducted epidemiologic study to investigate if the pleural abnormality is associated with pulmonary function change and what factors are influenced on pulmonary function impairment. Methods: Two hundred and twenty two asbestos workers from 9 industries using asbestos in Korea were selected to measure the concentration of sectional asbestos fiber. Ouestionnaire, chest X-ray, PFT were also performed. All the data were analyzed by student t-test and chi-square test using SAS. Regressional analysis was performed to evaluate important factors, for example smoking, exposure concentration, period and the existence of pleural thickening, affecting to the change of pulmonary function. Results: 1) All nine industries except two, airborn asbestos fiber concentration was less than an average permissible concentration. PFT was performed on 222 workers and the percentage of male was 88.3%, their mean age was $41{\pm}9$ years old, and the duration of asbestos exposure was $10.6{\pm}7.8$ yrs. 2) The chest X-ray showed normal(89.19%), pulmonary Tb(inactive)(2.7%), pleral thickening (7.66%), suspected reticulonodular shadow(0.9%). 3) The mean values of height, smoking status, concentration of asbestos fiberwere not different between the subjects with pleural thickening and others, but age, cumulative pack-years, the duration of asbestos exposure were higher in subjects with pleural thickening. 4) All the PFT indices were lower in the subjects with pleural thickening than in the subjects without pleural thickening. 5) Simple regression analysis showed there was a significant correlation between $FEF_{75}$ which is sensitive in small airway obstruction and cumulative smoking pack-years, the duration of asbestos exposure and the concentration of asbestos fiber. 6) Multiple regression analysis showed all the pulmonary function indices were decreased as the increase of cumulative smoking pack-years and especially in the indices those are sensitive in small airway obstruction. Pleural thickening was associated with reduction in FVC, $FEV_1$, PEFR and $FEF_{25}$. Conclusion: The more concentration of asbestos fiber and the more duration of asbestos exposure, the greater reduction in $FEF_{50}$, $FEF_{75}$. Therefore PFT was important in the evaluation of early detection for small airway obstruction. Furthermore pleural thickening without asbesto-related parenchymal lung disease is associated with reduction in pulmonary function.

  • PDF

Growth of Chinese Cabbage Plug Seedlings as Influenced by Various Pre-planting Nitrogen Concentrations in Inert Media (혼합상토에 기비로 혼합된 질소 농도가 배추 플러그묘 생장에 미치는 영향)

  • Sung, Jwa Kyung;Lee, Nu Ri;Choi, Jong Myung
    • Horticultural Science & Technology
    • /
    • v.34 no.4
    • /
    • pp.616-625
    • /
    • 2016
  • This research was conducted to investigate the optimum level of nitrogen incorporated during formulation of root media as pre-plant fertilizer on the growth of plug seedlings of 'Bool-am No.3' Chinese cabbage. A root medium was formulated by blending peatmoss:coir dust:perlite at a ratio of 3.5:3.5:3.0 (v/v/v). The nitrogen was incorporated in the seven treatments at a rate of 0, 100, 250, 500, 750, 1,000, and $1,500mg{\cdot}L^{-1}$ during the root medium formulation. The concentrations of other essential nutrients except nitrogen were controlled to equal in all treatments. Then, the root medium was packed into 72-cell plug trays and seeds were sown. The growth measurements as well as tissue and soil solution analysis for nutrients were conducted 2 and 4 weeks after seed sowing. As seedlings grew, the pH in the extracted solution of all treatments tended to decrease. The decreases in the treatments of high N concentrations were more severe than those with low N, but the differences among treatments were not statistically significant. The differences of EC in extracted solution of root media among treatments were sizable until week 3, but the differences began to lessen and the EC decreased in all treatments after week 4. Growth of the aerial parts of plug seedlings at 2 weeks after sowing were highest in the $100mg{\cdot}L^{-1}$ and lowest in the $1,500mg{\cdot}L^{-1}$ treatments, but those at 4 weeks after sowing were highest in the $500mg{\cdot}L^{-1}$ and lowest in the $0mg{\cdot}L^{-1}$ treatments among all treatments tested. The tissue N content was highest and lowest in the treatments of 250 and $1,000mg{\cdot}L^{-1}$, respectively, when tissues were harvested at 4 weeks after sowing and analysed based on the dry weight of above-ground tissue. The contents of micronutrients were the highest in the 1,000 and $1,500mg{\cdot}L^{-1}$ treatments among all treatments. The results shown above indicate that the $250mg{\cdot}L^{-1}$ of pre-plant N and elevation of post-plant N concentration to above $100mg{\cdot}L^{-1}$ are suitable for raising plug seedlings of Chinese cabbage using inert media.

Comparisons of Growth and Fruit Quality of Citrullus lanatus cv. Mudeungsan and Citrullus vulgaris cv. Dalgona Grown in Fertigation and Soilless Culture (무등산수박과 달고나수박의 관비재배와 양액재배에 있어서 생육 및 과실품질의 비교)

  • 이범선;정순주;박순기
    • Journal of Bio-Environment Control
    • /
    • v.8 no.1
    • /
    • pp.19-29
    • /
    • 1999
  • This experiment was conducted to compare with the growth and fruit quality of Citrullus lanatus cv. Mudeungsan and Citrullus vulgaris cv. Dalgona grown in fertigation and soilless culture. Seeds were sown on April 16 and transplanted on April 24, 1998. Cultural systems used in fertigation and soilless culture beds using mixed substrate, coir dust (50%) and perlite (50%). In the plot of fertigation system, the number of leaves of cv. Dalgona were increased more than that of cv Mudeungsan, but leaf area shown inversed trend. Plant growth shown greater in soilless culture than those of fertigation culture. In regardless of cultural systems, soluble solid content in fruit was higher in the cv. Dalgona than that of cv. Mudeungsan, but fruit fresh weight was greater in cv. Mudeungsan compare to the cv Dalgona. Nitrate content in petiole sap of watermelon in regardless of cultivars and cultural systems was 11.4∼13.4mg/gFW on 15 days after transplanting, and then increased to 17.1∼20.6mg/gFW on the fruit growth stage. Phosphorous content was 3.7∼5.7mg/gFW in the early growth stage while decreased to 0.6∼1.1mg/gFW from maturing stage to harvesting stage. Potassium content was increased to 5.8∼6.6mg/gFW in the early growth stage while decreased to 4.0∼4.8mg/gFW from pollination stage to harvesting stage. Calcium content in spa petiole of watermelon was higher in soilless culture as 3.4∼4.1mg/gFW than 2.5∼3.5mg/gFW of fertigation culture, but calcium content in fertigation culture during maturing stage was higher than that of soilless culture. The tendency of magnesium uptake was higher in fertigation culture than that of soilless culture, and was similarly absorbed in the range of 0.9∼1.3mg/gFW in regardless of cultural method after pollination. It was demonstrated that cv. Mudeungsan can be adapted to soilless culture and improved the fruit quality. Consequently, hydroponic possibility for year round culture in the greenhouse was recognized.

  • PDF

A Study on the Characteristics of Oil-water Separation in Non-point Source Control Facility by Coalescence Mechanism of Spiral Buoyant Media (나선형 부유 고분자 여재의 Coalescence 특성을 이용한 비점오염원 저감시설의 유수분리특성 연구)

  • Kang, Sung-Won;Kim, Seog-Ku;Kim, Young-Im;Yun, Sang-Leen;Kim, Soo-Hae;Kim, Mee-Kyung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.8
    • /
    • pp.950-955
    • /
    • 2007
  • Non-point source control system which had been designed only for oil-water separation in the fields of oil refinery and garage was upgraded in this research for the removal of runoff pollutants in impervious urban area. Pollutants including oil from driveway and bridge were eliminated by two types of pathway in the system. One is the coalescence mechanism that the oil droplets in the runoff come into contact with each other in the spiral buoyant media surface and form larger coalesced droplets of oil that are carried upstream to the oil layer. The other is the precipitation that solids in runoff were settled by gravity in the system. In this research, coalescing characteristics of oil and water separation were investigated through image analyses, and efficiencies of the non-point source control system were evaluated using dust in driveway and waste engine oil. Media made of high density and high molecular weight polyethylene was indeterminate helical shape and had sleek surface by analysing SEM photographs and BET. Surface area and specific gravity of media which were measured directly were 1,428 $mm^2$ and 45.3 $kg/m^3$ respectively. From the image analyses of the oil droplets photographs which were taken by using microscope, it was proved clearly that the coalescence was the main pathway in the removal of oil from the runoff. Finally, the performances of the non-point source control system filled up with the media were suspended solid $86.6\sim95.2%$, $COD_{Cr}$, $87.3\sim95.4%$, n-Hexane extractable materials $71.8\sim94.8%$ respectively.

Melting Characteristics for Radioactive Aluminum Wastes in Electric Arc Furnace (아크 용융로에서 방사성 알루미늄 폐기물의 용융특성)

  • Min, Byung-Youn;Song, Pyung-Seob;Ahn, Jun-Hyung;Choi, Wang-Kyu;Jung, Chong-Hun;Oh, Won-Zin;Kang, Yong
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.4 no.1
    • /
    • pp.33-40
    • /
    • 2006
  • The characteristics of the aluminum waste melting and the distribution of the radioactive nuclides have been investigated for the estimation on the volume reduction and the decontamination of the aluminum wastes from the decommissioning of the TRIGA MARK it and III research reactors at the Korea Atomic Energy Research Institute(KAERI). The aluminum wastes were melted with the use of the fluxes such as flux $A:NaCl-KCl-Na_3AlF_6$, flux B:NaCl-NaF-KF, flux $C:CaF_2$, and flux $D:LiF-KCl-BaCl_2$ in the DC graphite arc furnace. For the assessment of the distribution of the radioactive nuclides during the melting of the aluminum, the aluminum materials were contaminated by the surrogate nuclides such as cobalt(Co), cesium(Cs) and strontium(Sr). The fluidity of aluminum melt was increased with the addition of the fluxes, which has slight difference according to the type of fluxes. The formation of the slag during the aluminum melting added the flux type C and D was larger than that with the flux A and B. The rate of the slag formation linearly increased with increasing the flux concentration. The results of the XRD analysis showed that the surrogate nuclide was transferred to the slag, which can be easily separated from the melt and then they combined with aluminum oxide to form a more stable compound. The distribution ratio of cobalt in ingot to that in slag was more than 40% at all types of fluxes. Since vapor pressures of cesium and strontium were higher than those that of the host metals at the melting temperature, their removal efficiency from the ingot phase to the slag and the dust phase was by up to 98%.

  • PDF

Development of Root Media Containing Carbonized and Expanded Rice Hull for Container Cultivation of Horticultural Crops (팽연왕겨와 훈탄을 포함한 원예작물 용기재배용 혼합상토의 개발)

  • Park, Eun Young;Choi, Jong Myung;Shim, Chang Young
    • Horticultural Science & Technology
    • /
    • v.32 no.2
    • /
    • pp.157-164
    • /
    • 2014
  • Objective of this research was to develop root media containing expanded rice hull (ERH) and carbonized rice hull (CRH). To achieve this, the physico chemical properties of two materials were analysed and blended with peatmoss (PM) or coir dust (CD) with various ratio. Based on the physical properties of the blended materials, 4 root media were selected for future experiment. After the analysis of pH and EC of the selected root media, the kinds and amount of pre-planting nutrient charge fertilizers (PNCF) incorporated into each root medium were varied, and then, final chemical properties of the root media were analysed. The total porosity (TP), container capacity (CC), and air-filled porosity (AFP) were 81.3%. 39.9%, and 41.4% in ERH and 77.6%, 64.1%, and 13.5% in CRH, respectively. The percentage of easily available water (EAW, from CC to 4.90 kPa tension) and buffering water (BW, 4.91-9.81 kPa tension) were 11.37% and 5.27%, in ERH and 17.26% and 14.28% in CRH, respectively. The pH of ERH was 7.1, but it was extremely high in CRH such as 11.2. The EC and CEC were $1.31dS{\cdot}m^{-1}$ and $12.1meq{\cdot}100g^{-1}$ in ERH and $6.53dS{\cdot}m^{-1}$ and CEC 7.79 $meq{\cdot}100g^{-1}$ in CRH, respectively. The ranges of TP, CC and AFP in 4 selected media (PM + ERH, 6:4, v/v; CD + ERH, 8:2; PM + CRH, 7:3; CD+CRH 6:4) were 89.2-90.3%, 67.3-81.8%, and 8.3-21.9%, respectively. The pHs and ECs in root media containing peatmoss such as PM + ERH (6:4) and PM + CRH (7:3) were 4.0-4.3 and $0.33-0.365dS{\cdot}m^{-1}$, whereas those of CD + CRH were 7.4-7.9 and $1.282dS{\cdot}m^{-1}$. The pHs and ECs, however, analysed before and after the incorporation of PNCF in each root medium were not significant different. This result indicated that the incorporated fertilizers in PNCF to adjust medium pH did not dissolve enough to influence medium pH, but it is very normal in root media containing dolomitic lime and sulfur powder in adjusting pH. The Information obtained in this study may facilitate an effective formulation of root media containing rice hulls.

Evaluation of Dark Spots Formated on the High Temperature Metal Filter Elements (고온 금속필터 element 표면에 생성된 반점에 대한 평가)

  • Park, Seung-Chul;Hwang, Tae-Won;Moon, Chan-Kook
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.6 no.3
    • /
    • pp.171-178
    • /
    • 2008
  • Metal filter elements were newly introduced to the high temperature filter(HTF) system in the low- and intermediate-level radioactive waste vitrification plant. In order to evaluate the performance of various metal materials as filter media, elements made of AISI 316L, AISI 904L, and Inconel 600 were included to the test set of filter elements. At the visual inspection to the elements performed after completion of each test, a few dark spots were observed on the surface of some elements. Especially they were found much more at the AISI 316L elements than others. To check the dark spots are the corrosion phenomena or not, two kinds of analyses were performed to the tested filter elements. Firstly, the surfaces or the cross sections of filter specimens cut out from both normal area and dark spot area of elements were analyzed by SEM/EDS. The results showed that the dark spots were not evidences of corrosion but the deposition of sodium, sulfur and silica compounds volatilized from waste or molten glass. Secondly, the ring tensile strength were analyzed for the ring-shape filter specimens cut out from each kind of element. The result obtained from the strength tested showed no evidence of corrosion as well. Conclusionally, depending on the two kinds of analysis, no evidences of corrosion were found at the tested metal filter elements. But the dark spots formed on the surface could reduce the effective filtering area and increase the overall pressure drop of HTF system. Thus, continuous heating inside filter housing up to dew point will be required normally. And a few long-period test should be followed for the exact evaluation of corrosion of the metal filter elements.

  • PDF