• 제목/요약/키워드: Duration of Injection

검색결과 477건 처리시간 0.028초

Modeling of the filling process during resin injection/compression molding

  • Chang, Chih-Yuan
    • Advanced Composite Materials
    • /
    • 제16권3호
    • /
    • pp.207-221
    • /
    • 2007
  • The filling process of resin injection/compression molding (I/CM) can be divided into injection and compression phases. During the resin injection the mold is kept only partially closed and thus a gap is present between the reinforcements and the upper mold. The gap results in preferential flow path. After the gap is filled with the resin, the compression action initiates and forces the resin to penetrate into the fiber preform. In the present study, the resin flow in the gap is simplified by using the Stokes approximation, while Darcy's law is used to calculate the flow field in the fiber mats. Results show that most of the injected resins enter into the gap during the injection phase. The resin injection time is extremely short so the duration of the filling process is determined by the final closing action of the mold cavity. Compared with resin transfer molding (RTM), I/CM process can reduce the mold filling time or injection pressure significantly.

CRDI 디젤엔진의 피에조 인젝터 불량에 따른 파형 분석에 관한 실험적 연구 (An Experimental Study on the Waveform Analysis According to Troubles of Piezo Injector of CRDI Diesel Engine)

  • 유종식;김철수
    • 한국기계기술학회지
    • /
    • 제20권6호
    • /
    • pp.783-789
    • /
    • 2018
  • This paper investigates the relationship of voltage and current waveform between normal piezo injector and deterioration abnormal piezo injector. The experimental methods using Pico oscilloscope and GDS scan tool are employed to measure current and voltage waveform and fuel pressure of piezo injector. The experiment is carried out during no-load condition. A summary of the important results are as follows. 1) In case of normal injector, the fluctuation of duration time of piezo injector was linearly and regularly decreased with increasing engine speed, but the that of deterioration piezo injector was irregularly decreased with increasing engine speed. 2) In main injection, the peak value of the current waveform of abnormal injector was larger than that of normal injector, the duration time of deteriorated abnormal injector was less than that of normal injector at 800rpm and 1500rpm, but the duration time of deteriorated abnormal injector was larger than that of normal injector at 2000rpm and 3000rpm. This irregularity appears to be caused by the deterioration of the injector.

극 저주파 및 휴대전화 전자파 환경 변수를 고려한 새포막 활동 전위 모형 (A Computational Model for a Neuronal Membrane Considering the Extremely Low Frequency and Mobile Phone Frequency Electromagnetic Field Effect)

  • 서영준;이은주;안재목;이용업;황태금;이재선;서정선
    • 대한의용생체공학회:의공학회지
    • /
    • 제24권4호
    • /
    • pp.347-354
    • /
    • 2003
  • 본 논문에서는 극 저주파와 휴대전화 전자파 (외부전자파) 환경의 영향이 고려된 세포막 활동 전위의 모의실험 모형을 제안하였다. Hodgkin과 Huxley 모형을 기초로 한 이 모형은 주사 전류 (injection current)에 전자파 효과를 적용하였으며 전자파의 주파수 영역에 대한 수치적 모의실험을 통하여 Strength-Duration 곡선을 얻는데 사용되었다 모의실험에서 사용된 수치해석 방법은 Runge-Kutta Fehlberg 방법이다. 모의실험에 고려된 주파수 영역은 1 Hz에서 100 Hz 사이와 이동통신에서 사용되는 900 티Hz의 주파수였다. 모의실험을 통하여 얻은 Strength-Duration 곡선은 Hodgkin과 Huxley가 제안한 방정식과 잘 일치함을 보여주었다.

다공 노즐에서 분사조건이 디젤 연료의 미립화 특성에 미치는 영향 (Effect of Injection Condition on the Diesel. Fuel Atomization in a Multi-Hole Nozzle)

  • 서현규;김지원;이창식
    • 한국분무공학회지
    • /
    • 제14권1호
    • /
    • pp.8-14
    • /
    • 2009
  • This paper present the diesel fuel spray evolution and atomization performance in a multi-hole nozzle in terms of injection rate, spray evolutions, and mean diameter and velocity of droplets in a compression ignition engine. In order to study the effect of split injection on the diesel fuel spray and atomization characteristic in a multi-hole nozzle, the test nozzle that has two-row small orifice with 0.2 mm interval was used. The time based fuel injection rate characteristics was analyzed from the pressure variation generated in a measuring tube. The spray characteristics of a multi-hole nozzle were visualized and measured by spray visualization system and phase Doppler particle analyzer (PDPA) system. It was revealed that the total injected fuel quantities of split injection are smaller than those of single injection condition. In case of injection rate characteristics, the split injection is a little lower than single injection and the peak value of second injection rate is lower than single injection. The spray velocity of split injection is also lower because of short energizing duration and small injection mass. It can not observe the improvement of droplet atomization due to the split injection, however, it enhances the droplet distributions at the early stage of fuel injection.

  • PDF

커먼레일 타입 피에조 인젝터의 정밀 다단분사 제어를 위한 분사특성 연구 (A Study on the Injection Characteristics of a Piezo Injector for Controlling Accurate Multiple Injection)

  • 박희범;김형익;박상기;이기형
    • 한국분무공학회지
    • /
    • 제18권4호
    • /
    • pp.176-181
    • /
    • 2013
  • In this study, injection quantity, rate and spray image of multiple injections which are important design parameters for a piezo type injector have been investigated. Interval of injections and a number of injections in multiple injection strategy has been controlled to verify interaction of each injection. Spray characteristics of multiple injections have been researched through optical process with a high speed camera in a high pressure chamber. In addition, a method of RMS(Root Mean Square) process has been used for comprehending the distribution of injection easily. As a result, in case of piezo type injector, characteristics of injection quantity according to charging voltage and the difference of injection quantity between single and triple injection were confirmed. Also, injection rate for increasing injection duration was confirmed. And spray characteristics of multiple injections were improved; multiple injections were possible in a shorter time interval between each injection. With this study, a possibilities of more accurate multiple injection control would be expected.

성대주입술 후 발생한 성대 내 농양 1례 (A Case of Vocal Cord Abscess after Injection Laryngoplasty)

  • 이종숙;김지원;최승호
    • 대한후두음성언어의학회지
    • /
    • 제21권2호
    • /
    • pp.142-144
    • /
    • 2010
  • Unilateral vocal cord paralysis occurs from a dysfunction of the recurrent laryngeal nerve. It causes a characteristic hoarseness, shortness of breath and swallowing disability. Prompt injection laryngoplasty is a treatment options that aims to improve these symptoms less invasively and easily than any other procedures. Cross-linked hyaluronic acid (HA) is widely used injection material. It is non-mammalian polysaccharides derived from streptococcus strain and well known for its duration in vocal cord about 3-6 months after injection. However, there were no complication reports such as infection or rejection after HA injection laryngoplasty in previous report. We present a case of patient with laryngeal abscess after transcricothyroid membrane percutaneous HA injection laryngoplasty.

  • PDF

선박디젤기관용 분사밸브의 형상변화가 분사특성에 미치는 영향에 관한 계산적 고찰 (The Effect of Valve Geometry Variation on Injection Characteristics of Injection Valve for Marine Diesel Engines)

  • 박권하;김성윤;최창우
    • 한국분무공학회지
    • /
    • 제10권1호
    • /
    • pp.24-34
    • /
    • 2005
  • Injection technology is one of the important technologies in a diesel engine. Many studies have done on the injection system. In this study, the fuel chamber geometry, the orifice ratio and the needle lift of the injection valve for a marine diesel engine are varied, and simulated. The result shows that the nozzle hole size has influence on the rail pressure and injection duration sensitively. The decrease of the static pressure at the nozzle hole entrance and the increase of the dynamic pressure on the outlet surface are occurred with the increase of the nozzle hole diameter. The highest dynamic pressure of the outlet was occurred at the needle lift of 0.4mm and the nozzle hole diameter of 0.328mm in this test nozzle.

  • PDF

SAC 형상이 분사특성 및 분무형상에 미치는 영향 (Influence of SAC Shape on Injection Characteristics and Spray)

  • 김상진;권순익
    • 한국자동차공학회논문집
    • /
    • 제9권2호
    • /
    • pp.11-18
    • /
    • 2001
  • To clarify the influence of SAC shape of hole-type diesel nozzle on injection characteristics and spray patterns, the injection rate of three nozzle types(standard SAC nozzle, Needle-cut VCO nozzle and VCO nozzle) were measured by Zeuch's method and pictures of the sprays were taken by CCD camera. As the pump speed became higher, the injection characteristics of the three nozzles were different. Injection rate and perssure curves at the high pressure pipe in Needle-cut VCO nozzle were much more similar to the VCO nozzle than those of the SAC nozzle. When the needle was at pre-lift period for all speeds, the spray of the Needle-cut VCO nozzle showed almost the same shape as the SAC type nozzle. There was no differense in spray pattern at the needle full-lift periods.

  • PDF

디젤기관의 분사밸브를 위한 고속 솔레노이드의 성능에 관한 연구 (A Study of Performance Test of High Speed Solenoid for Fuel Injector in Diesel Engine)

  • 조규학;라진홍;안수길
    • 동력기계공학회지
    • /
    • 제5권3호
    • /
    • pp.11-16
    • /
    • 2001
  • In the DI diesel engine of passenger cars, common rail injection system have been used to improve the engine performance and reduce the exhaust emission by controlling injection timing, injection pattern, and injection duration. In case that common rail injection system is applied to high speed DI diesel engine, it is necessary to have high response and good repetition characteristics. These characteristics of injector depend on the characteristics of solenoid. Thus, to apply the common rail injection system in the high speed diesel engine, we had designed and made a multi-pole solenoid, and carried out repetition, response test to compare the multi-pole solenoid with the gasoline Injector solenoid. The result shows that repetition and response characteristics of multi-pole solenoid have better characteristics than the gasoline injector solenoid.

  • PDF

Clinical evaluation of efficacy of transcortical anesthesia for the extraction of impacted mandibular third molars: a randomized controlled trial

  • Demir, Esin;Ataoglu, Hanife
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제20권1호
    • /
    • pp.9-17
    • /
    • 2020
  • Background: This study aimed to compare the pain levels during anesthesia and the efficacy of the QuickSleeper intraosseous (IO) injection system and conventional inferior alveolar nerve block (IANB) in impacted mandibular third molar surgery. Methods: This prospective randomized clinical trial included 30 patients (16 women, 14 men) with bilateral symmetrical impacted mandibular third molars. Thirty subjects randomly received either the IO injection or conventional IANB at two successive appointments. A split-mouth design was used in which each patient underwent treatment of a tooth with one of the techniques and treatment of the homologous contralateral tooth with the other technique. The subjects received 1.8 mL of 2% articaine. Subjects' demographic data, pain levels during anesthesia induction, tooth extractions, and mouth opening on postoperative first, third, and seventh days were recorded. Pain assessment ratings were recorded using the 100-mm visual analog scale. The latency and duration of the anesthetic effect, complications, and operation duration were also analyzed in this study. The duration of anesthetic effect was considered using an electric pulp test and by probing the soft tissue with an explorer. Results: Thirty patients aged between 18 and 47 years (mean age, 25 years) were included in this study. The IO injection was significantly less painful with lesser soft tissue numbness and quicker onset of anesthesia and lingual mucosa anesthesia with single needle penetration than conventional IANB. Moreover, 19 out of 30 patients (63%) preferred transcortical anesthesia. Mouth opening on postoperative first day was significantly better with intraosseous injection than with conventional IANB (P = 0.013). Conclusion: The IO anesthetic system is a good alternative to IANB for extraction of the third molar with less pain during anesthesia induction and sufficient depth of anesthesia for the surgical procedure.