• Title/Summary/Keyword: Duralumin

Search Result 31, Processing Time 0.027 seconds

Quantitative analysis of body postural stability (신체자세 안정도의 정량분석에 관한 연구)

  • Cha, E.J.;Kim, K.A.;Lee, T.S.;Lee, K.M.;Kim, N.K.;Kim, Y.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.39-43
    • /
    • 1997
  • Posturography stands or quantitative assessment of body postural stability analysis. The present study developed a balance plate system to monitor patient's center of pressure (COP) movement and to analyze its stability. An equilateral triangular shaped plate was made of duralumin and forces were measured on the three vertices of the plate using industrial load cells. Specially designed electronic circuit picked up force signals ed into data acquisition system to calculate the cartesian coordinates of COP. COP calculation error was less than 2%. The force signals enabled to compute stability measures, which consisted of a variety of clinical parameters related to postural stability. Clinical experiments were carefully designed and performed on 40 normal subjects. The results were that 1) postural stability decreased with age and 2) the best parameters were those of posture deviation measures. A customized PC-based software package was developed to apply the present technique with a great convenience to monitoring and analyzing postural stability in an accurate and quantitative way.

  • PDF

Development of Standard Antenna for DTV Signal Measurement (DTV 신호 측정용 표준 안테나 개발)

  • Kwon, Won-Hyun;Kim, Joon-Sik;Park, Young-Shin;Kim, Young-Taek
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.44 no.1
    • /
    • pp.18-23
    • /
    • 2007
  • In this paper, LPDA standard antenna for measuring DTV signal strength is developed. Duralumin material is used to fabricate antenna having mechanical strength and flexibility. Operating frequency of designed antenna is range from $450{\sim}850$MHz and its gain is greater than 10 dBd to satisfy FCC requirements. Experimental results show that the developed antenna has minimum 10 dBd gain (average 11.7 dBd) over the entire frequency region and has ${\pm}1.5$ dB pass band ripple characteristic, From the results, the developed antenna is well adequate for standard antenna to measure DTV signal strength.

Development of Objective Nasometer Using a Vibratory Sensor and its Clinical Application (진동 센서를 이용한 객관적 비강공명 측정 장치의 개발 및 그 임상적 이용)

  • 최홍식;박용재;김광문
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.6 no.1
    • /
    • pp.46-55
    • /
    • 1995
  • Authors devised an objective test for nasal resonatory disorders using a vibratory sensor(Piezoelectric receiver) which is relatively cheap. The vibratory sensor was covered with duralumin to eliminate contamination of acoustic sound except a small hole which is attached on ala nasi during the test. Electrical signals front the vibratory sensor and the microphone while the subject is phonating vowel/a/ and nasal consonant /ng/ and phonating 8 syllable sentence /papa/ passage and /mama/ passage were digitized with n 12 bit A/D converter. For the evaluation of the hypernasality, the ratio of /ng/ to /a/ and /mama/ passage to /papa/ passage were used instead of individual values to reduce the observational error. For the evaluation of the hyponasality, the cul-de-sac resonation was induced by obstructing the nasal aperture of the ipsilateral side with the finger. In the normal control group, the ratio of /ng/ to /a/ and /mama/ passage to /papa/ passage was larger than 8. In the hypernasality with nasal emission group. the ratio was decreased markedly(p<0.01). When the nasal aperture was obstructed with the finger, the vibratory signals of /a/ and /ng/ were increased markedly in the control group and hypernasality group(p<0.01). However, in the hyponasality group(severe), the increment was minimal. So this system can be used to detect the nasal resonatory disorders objectively and differentiate the hypernasality front hyponasality easily.

  • PDF

Development of the Self-Build based Emergency Towers for Overhead Transmission Line (송전선로 비상복구용 자주조립식 철주 개발)

  • Byun Gang;Min Byeong Wook;Wi Hwa Bog;Park Jae Ung;Baek Soo Gon
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.494-496
    • /
    • 2004
  • Due to a typhoon named MAEMI on Sep12, 2004, 7 transmission towers collapsed and 3 were damaged in the Gyeongnam and Busan areas. These caused long-term black-outs in Goeje-do. When a transmission tower collapses or is damaged, Construction will take more than 2 months and this will be accompanied by long-term black-outs. Therefore a temporary iron pole is used in such emergencies. Current temporary rehabilitation angle steel iron Pole consistes of around 800 members, 2,800 bolts and it takes about 5 days to construct a temporary transmission line. Consiquently wide black-outs occur during the construction of the temporary transmission line. To reduce black-out time, the construction period must be reduced as much as possible. This paper presents new methods to reduce temporary transmission line construction time to within 48 hours by applying a self-reliance assembling method instead of the current man power assembling method and by modulizing each angle steel with duralumin.

  • PDF

Development of Subminiature Type 3 Composite Pressure Vessel for Cooling Unit in Electric Appliances (전자제품 쿨링 유닛용 초소형 타입 복합재 압력용기 개발)

  • Cho, Sung-Min;Lee, Seung-kuk;Moon, Jong-sam;Lyu, Sung-ki
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.6
    • /
    • pp.151-157
    • /
    • 2018
  • In this study, we have developed a composite pressure vessel that is compact and can store refrigerant at high pressure to increase the refrigerant volume. The composite pressure vessel is made of aluminum-based duralumin, which has high rigidity and excellent elongation in the inner liner, considering the characteristics of products in the aerospace and defense industry, where the safety of the applied product is considered as a priority. High strength carbon fiber was applied to the outside. In order to evaluate the performance of the developed product, burst test and cycling test were carried out. In burst test, an excellent safety margin equivalent to 2.7 times the operating pressure was obtained. In cycling test, a stable failure mode in which 'pre-burst leak' occurs is proved and the soundness of the product is proved.

Stability Analysis of a Micro Stage for Micro Cutting Machine with Various Hinge Type and Material Transformation (초정밀 가공기용 마이크로 스테이지의 힌지 형상과 재질 변화에 따른 안정성 해석)

  • Kim, Jae-Yeol;Kwak, Yi-Gu;Yoo, Sin
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.7
    • /
    • pp.233-240
    • /
    • 2003
  • Recently, the world are preparing for new revolution, called as If (Information Technology), NT (Nano-Technology), and BT (Bio-Technology). NT can be applied to various fields such as semiconductor-micro technology. Ultra precision processing is required for NT in the field of mechanical engineering. Recently, together with radical advancement of electronic and photonics industry, necessity of ultra precision processing is on the increase for the manufacture of various kernel parts. Therefore, in this paper, stability of ultra precision cutting unit is investigated, this unit is the kernel unit in ultra precision processing machine. According to alteration of shape and material about hinge, stability investigation is performed. In this paper, hinge shapes of micro stage in UPCU(Ultra Precision Cutting Unit) are designed as two types, where, hinge shapes are composed of round and rectangularity. Elasticity and strength are analyzed about micro stage, according to hinge shapes, by FE analysis. Micro stage in ultra precision processing machine has to keep hinge shape under cutting condition with 3-component force (cutting component, axial component, radial component) and to reduce modification against cutting force. Then we investigated its elasticity and its strength against these conditions. Material of micro stage is generally used to duralumin with small thermal deformation. But, stability of micro stage is investigated, according to elasticity and strength due to various materials, by FE analysis. Where, Used materials are composed of aluminum of low strength and cooper of medium strength and spring steel of high strength. Through this stability investigation, trial and error is reduced in design and manufacture, at the same time, we are accumulated foundation data for unit control.

A Motor/Generator for Flywheel Energy Storage System Levitated by Bulk Superconductor (초전도 부상 플라이휠 에너지 저장시스템의 구동을 위한 전동/발전기)

  • Go, Chang-Seop;Yeon, Je-Uk;Choe, Jae-Ho;Jeong, Hwan-Myeong;Hong, Gye-Won;Lee, Ho-Jin
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.6
    • /
    • pp.411-420
    • /
    • 2000
  • The energy storage systems are being widely researched for the high quality of the electric power. The FES(flywheel energy system) is especially, on the center of the research because it does not make any pollution and its life is long. The FES converts the electrical energy into the mechanical kinetic energy of the flywheel and reconverts the mechanical energy into the electrical energy. In order to store as much energy as possible, the flywheel is supposed to be rotated with very high speed. The motor/generator of the FES should be high efficient at high speed, and generate constant torque with respect to the rotation. In this paper, a motor/generator employing a Halbach array of permanent magnets is designed and constructed to meet the requirements, and its characteristics are examined. The magnetic field is analysed by using the magnetic surface charge method. The armature winding is designed for the harmonic components to be minimized by using the FFT. The sinusoidal current for the motor driving are generated by the hysteresis current controller. A sample superconducting flywheel energy storage system is constructed with a duralumin flywheel which has a maximum rotating speed of 40,000[rpm] and a stored energy of 240[Wh] and its validity is examined through the experiment.

  • PDF

The Development of the Movable-housing Planning Concept in Housing-architectural history of 20th Century (20 세기 주거건축사에 나타난 이동식 주거개념의 발전과정에 관한 연구)

  • Kim, Mi-Kyoung
    • Korean Institute of Interior Design Journal
    • /
    • v.17 no.2
    • /
    • pp.13-21
    • /
    • 2008
  • The purpose of this study is to analyze the development and characteristics of movable-housing planning concept. A document research method was used to analyze and classified the development of the movable-housing concept of 20th century. Through this study, the following conclusions have been reached; First, the origin of the movable-housing is from the prehistoric and traditional portable buildings, also due to the emergence of nomadic lifestyle using car traveling and mobile home in the 1920's. Second, the development of the movable-housing in 20th century was classified as follows; (1) In order to obtain the productivity and efficiency drawing from the industrialized-housing in the early of 1900s, movable furniture and flexibility was proposed. (2) American mobile home in 1920's, influenced by the development of car industry, was the most successful example of a factory-built building to be found in the world. (3) Dymaxion house and dome by R.B.Fuller, an aggregation of high-tech mechanical equipment, had a great impact on the development the concept of 'mobility' and influenced Archigram & Metabolist's movable capsule ideas in 1960's. (4) The lightweight materials such as plastic, duralumin and pneumatic structure were adopted for movable-housing in 1960's. Through this research, It is discovered that the stage of social development has close links with the developing aspects of movable-housing concepts. This study shows that the combination of three planning concepts such as flexible housing, mobile-housing and capsule will be more ideal in movable-housing planning rather than relying on just one type.

Fundamental Heat Analysis about the Thermoelectric Generation System Using the Waste Heat of Exhaust Gas from Ship (선박의 배기가스 폐열을 활용한 열전발전시스템에 관한 기초 열해석)

  • Kim, Myoung-Jun;Ga, Gwang-Jin;Chea, Gyu-Hoon;Kim, In-Seup
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.22 no.5
    • /
    • pp.583-592
    • /
    • 2016
  • IMO (International Maritime Organization) in the UN (United Nations) set up that aim at reducing $CO_2$ emission from ship by up to 30 percent until 2030. The final purpose of this study is the development of marine thermoelectric generation system using waste heat from vessel of internal combustion engines. Before the development of marine thermoelectric generation system, this paper carried out the fundamental heat analysis of marine thermoelectric generation system. It was able to obtain the valuable results about the efficiency improvement of the thermoelectric generation system. The results is as follows : 1) It was confirmed that the efficiency of thermoelectric generation system improves to 8.917 % with increasing the temperature difference of peltier module by reducing the temperature difference between peltier module and heat source at the hot side. 2) System efficiency according to change in the external load resistance was confirmed that the change width of about 6 % which does not significantly occur. 3) System efficiency in the case stainless steel at the same condition is 8.707 %. System efficiency could be confirmed that the stainless steel is higher than duralumin (8.605 %), copper (8.607 %).

Development of A Fractionated Stereotactic Radiotherapy System (분할 정위방사선 치료 시스템 개발 연구)

  • 이동한;지영훈;이동훈;조철구;김미숙;유형준;류성렬
    • Progress in Medical Physics
    • /
    • v.13 no.1
    • /
    • pp.9-14
    • /
    • 2002
  • We invented the newly developed Fractionated Stereotactic Radiotherapy(F.S.R.T) system using combined techniques of couch mounting and pedestal mounting system. Head fixation frame consists of a milled alluminium alloy(duralumin) and is placed to the couch. This frame immobilized patient head using the dental bite, 3.2 mm frontal and occipital thermoplastic mask. To evaluate the coordinate of target isocenter, Brown-Revert-Walls C.T localizer can be attached to this frame. And also, we developed the frame mounting system by developing the modification of pedestal mounting system. This system is fixed to couch floor and can be used to evaluate the isocenteric accuracy of gantry, couch and collimator in Q.A procedure. In order to measure the relocation accuracy, the acrylic phantom and the accurate pointers have been made. The repositioning of the targets in the phantom were estimated by comparing C.T coordinates and E.C.L portal films taken with anterior-posterior and right-left direction. From the results of experiments, the average distance errors between the target isocenter and its mean position were 0.71$\pm$0.19 for lateral, 0.45$\pm$0.15 for inferior-superior, 0.63$\pm$0.18 for anterior-posterior. And the maximum distance error was less than 1.3 mm. The new head fixation frame and frame mounting system were non-invasive, accurately relocatable, easy to use, very light and well tolerable by the results of phantom tests. The major advantage of using this frame mounting system is complete access to any point in the Patients cranium especially posterior direction

  • PDF