• Title/Summary/Keyword: Dupont

Search Result 57, Processing Time 0.026 seconds

A Review on the Financial Profile of Profitability for the KOSDAQ Listed Firms Headquartered in 'Chungcheong' province in the Republic of Korea (국내 충청권 기반 KOSDAQ 상장기업들의 수익성 결정요인 분석)

  • Kim, Hanjoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.11
    • /
    • pp.5476-5487
    • /
    • 2013
  • From foreign and/or domestic investors' perspectives, it may be interesting to find any financial attributes or profile of the firms headquartered in 'Chungcheong' province concerning profitability, given that this subject so far drew less attention in the previous literature. This study performed three hypothesis tests on the profitability indicator by utilizing the models such as the 'panel data' one and the 'logistic' regression one, applying a modified 'Dupont' system. With respect to the major findings, the results identified that the proxies measuring leverage across the book-value(BVLEV1) and the market-value(MVLEV1) bases, were statistically significant constituents determining profitability. Another explanatory variable, SIZE, with its positive and statistically significant relationship to the indicator, represented that the firms in the province were smaller than their counterparts in the other regional areas in Korea. DRELY applying a modified 'Dupont' system, found to be the only statistically significant discriminating factor between these comparison groups. As one of the primary contributions of this study, the outcomes may be used by the financial institutions operated across the regions including Seoul Metropolitan area, when implementing their lending practices to provide funds for potential borrowers such as the firms belonging to 'Chungcheong' province.

The Study on the Quantitative Analysis in LPG Tank's Fire and Explosion (LPG 저장탱크에서의 화재$\cdot$폭발에 관한 정량적 영향 평가에 관한 연구)

  • Bae Sung-Jin;Kim Byung-Jick
    • Journal of the Korean Institute of Gas
    • /
    • v.3 no.1
    • /
    • pp.21-26
    • /
    • 1999
  • Chemical plant's fire and explosion does not only damage to the chemical plants themselves but also damage to people in or near of the accident spot and the neighborhood of chemical plant. For that reason, Chemical process safety management has become important. One of safety management methods is called 'the quantitative analysis', which is used to reduce and prevent the accident. The results of the quantitative analysis could be used to arrange the equipments, evaluate the minimum safety distance, prepare the safety equipments. In this study we make the computer program to make easy to do Quantitative analysis of the accident. The output of the computer program is the magnitude of fire(pool fire and fireball) and explosion(UVCE and BLEVE) effects. We used the thermal radiation as a measure of fire magnitude and used the overpressure as a measure of explosion magnitude. In case of BLEVE, the fly distance of fragment can be evaluated. Also probit analysis was done in every case. As the case study, Buchun LPG explosion accident in Korea was analysed by the program developed. The simulation results showed that the permissible distance was 800m and probit analysis showed that 1st degree bum, 2nd degree burn, and death distances are 450, 280, 260m, respectively the simulation results showed the good agreement with the results from SAFER PROGRAM made by Dupont.

  • PDF

Design of Distributed Band Pass Filter for 900MHz ZigBee System applications (900MHz ZigBee System 응용 분포소자형 Band Pass Filter 설계)

  • Lee, Joong-Keun;Yoo, Chan-Sei;Kim, Dong-Su;Won, Kwang-Ho;Lee, Woo-Sung
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.163-166
    • /
    • 2005
  • Multilayer LTCC technology enables RF modules to be reduced dramatically by taking advantage of the three dimension flexibility. Compared to a conventional two dimensional PCB, LTCC allows higher density, reduced size, and lower cost. In this research, BPF based on LTCC for 900MHz ZigBee application was implemented which can replace SAW filter with using the material of the Dupont9599's dielectric constant 7.8. And distributed baud pass filter for 900MHz ZigBee system applications is presented. Using resonator stripline and capacitance, 2nd order band pass filter was designed. Adjusting resonator's length and capacitance is easy to tune at accurate center frequency by shifting band because ZigBee system is using narrow bandwidth, $902MHz^{\sim}928MHz$. Also resonator has no limitation in space, so reducing size is possibile. Designed filter had I.L. 2.8dB at 915MHz and attenuation at 815MHz, 1015MHz was 16dB, 15dB, respectively. Therefore, the sharpe cut-off and good insertion loss for ZigBee system application.

  • PDF

Design of Multi-layer VCO for 960 MHz Band (960 MHz대역 다층구조 VCO 설계)

  • 이동희;정진휘
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.6
    • /
    • pp.492-498
    • /
    • 2002
  • In this paper, we present the simulation results of multi-layer VCO(voltage controlled oscillator), which is composed of resonator, oscillator, and buffer circuit, using EM simulator and nonlinear RF circuit simulator. EM simulator is used for obtaining the EM(Electromagnetic) characteristics of conductor pattern as well as designing the multi-layer VCO. Obtained EM characteristics were used as real components in nonlinear RF circuit simulation. Finally the overall VCO was simulated by the nonlinear RF circuit simulator. The material for the circuit pattern was Ag and the dielectric was Dupont 951AT, which will be applied for LTCC process. The structure of multi-layer VCO is constructed with 4 conducting layer. Simulated results showed that the output level was about 4.5 [dBm], the phase noise was -104 [dBc/Hz] at 30 [kHz] offset frequency, the harmonics -8 dBc, and the control voltage sensitivity of 30 [MHz/V] with a DC current consumption of 9.5 [mA]. The size of VCO is $6{\times}9{\times}2 mm$(0.11 [cc]).

Correlation between galaxy mergers and AGN activity

  • Hong, Ju-Eun;Im, Myung-Shin
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.1
    • /
    • pp.47.2-47.2
    • /
    • 2012
  • Using deep images taken at Maidanak 1.5m telescope, at McDonald 2.1m telescope and Canada-France-Hawaii Telescope, Dupont 2.5m telescope we investigated the fraction of merging galaxies in hosts of 39 AGN which are brighter than M = -22 mag and nearer than z = 0.3. We found that 16 to 17 of 39 AGN host galaxies show the evidence of mergers like tidal tail, shell via careful visual inspection. We also studied with the merging fraction of a control sample, SDSS Stripe82 early type galaxies of which surface brightness limit and bulge magnitude are similar to that of the AGN sample. We found that merging fraction of the AGN sample is higher than that of early type galaxy samples in the whole range of bulge magnitude. This result implies that AGN activity may be correlated with merging. We also investigated the detailed morphology of merging feature. At least - 1/4 of control samples classified as a tidal and tidal+dust are shell structures. On the other hand only one (5.9%) of AGN sample classified as merger shows shell structures, and almost all merging AGNs show tidal tail features. From point of view that tidal tail may be at the early stage of merging, and shell may be at the late stage of mergers, this result suggests that AGN might be evolved into early-type galaxies after merging.

  • PDF

Micro humidity sensor with poly imide sensitive layer (폴리이미드를 감지막으로 한 마이크로 정전용량형 습도센서)

  • Shin, P.K.;Cho, K.S.;Park, G.B.;Yuk, J.H.;Park, J.K.;Im, H.C.;Ji, S.H.;Kim, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.1898-1899
    • /
    • 2005
  • 반도체 집적회로 공정에서 사용되는 폴리이미드 포토레지스트(P12723, Dupont)를 감습막으로 사용하는 마이크로 습도센서 소자를 제작하였다. 마이크로 습도센서는 실리콘 웨이퍼 기판 위에 $SiO_2$ 박막을 건식열산화 공정으로 제작하고, Al 박막을 포토리소그라피 공정으로 패터닝 한 IDT (Interdigital Transducer)를 전극 위에 폴리이미드 포토레지스트를 공정변수를 다양하게 조절하면서 감습막으로 제작하였다. 폴리이미드 감습막은 스핀코팅법으로 제작하였으며, 회전수를 조절하여 두께를 변화시켰다. 완성된 마이크로 습도센서 소자의 상대습도 변화$(10{\sim}90% RH)$에 따른 정전용량 값 변화를 항온항습조 내에서 다양한 온도에서 HP4192A Impedance Analyzer를 사용하여 조사함으로써, 폴리이미드 포토레지스트를 사용하는 마이크로 정전용량형 습도센서의 제작 가능성을 검토하였다. 폴리이미드 정전용량형 마이크로 습도센서는 다양한 인가 전원 주파수에서 기준 센서로 사용된 상용 Vaisala Hygrometer와 유사한 감습특성 및 응답특성을 보였다.

  • PDF

THE COMPARING STUDY OF THE DIELECTRIC CHARACTERISTIC FROM THE LTCC MICROSTRIP RESONATOR ARCHITECTURES (LTCC MICROSTRIP RESONATOR 구조에 따른 유전특성 비교 연구)

  • Lee, Joong-Keun;Jung, Hyun-Chul;Yoo, Chan-Sei;Kim, Dong-Su;Yoo, Myung-Jae;Park, Sung-Dae;Lee, Woo-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.309-310
    • /
    • 2005
  • Generally, the dielectric constant and loss tangent are gotten by resonators. This paper presents analysis of the comparing the dielectric constant and loss tangent from the Ring, T and series gap structures. The T structure can be analyzed easily at wideband characteristic with simple design. the Ring can ignore the radiation loss from the open-ended effect. the Series gap can get more accurate permittivity than a Ring structure. The Used materials were dupont9599 LTCC ceramic and daeju0086 Ag.

  • PDF

Superhydrophobic Engineered Surface Based on Nanohoneycomb Structures (나노허니컴 구조물을 이용한 산업용 극소수성 표면 제작)

  • Kim, Dong-Hyun;Park, Hyun-Chul;Lee, Kun-Hong;Hwang, Woon-Bong
    • Composites Research
    • /
    • v.20 no.2
    • /
    • pp.17-20
    • /
    • 2007
  • Superhydrophobic polytetrafluoroethylene ($Teflon^{(R)}$, Dupont) sub-micro and nanostructures were fabricated by the dipping method, based on anodization process in oxalic acid. The polymer sticking phenomenon during the replication creates the sub-microstructures on the negative polytetrafluoroethylene nanostructure replica. This process gives a hierarchical structure with nanostructures on sub-microstructures, which looks like the same structures as lotus leaf and enables commercialization. The diameter and the height of the replicated nano pillars were 40 nm and 40 um respectively. The aspect ratio is approximately 1000. The fabricated surface has a semi-permanent superhydrophobicity, the apparent contact angle of the polytetrafluoroethylene sub-micro and nanostructures is about $160^{\circ}$, and the sliding angle is less than $1^{\circ}$.

Design and implementation of photopolymer-based holographic volume grating couplers for optical interconnection (광연결을 위한 포토폴리머형 홀로그래픽 부피격자 커플러의 설계 및 구현)

  • Lee, Kwon-Yeon;Jeung, Sang-Huek;Cho, Byung-Mo;Son, Myung-Sik;Jeon, Seok-Hee
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.9 no.4
    • /
    • pp.261-271
    • /
    • 2008
  • Holographic volume grating couplers (VGCs) are become increasingly attractive device for the application of optical interconnects because of their higher preferential coupling, dry fabrication processing, compact, and low cost. In this paper, the analysis, design, and implementation of the waveguide-imbedded input-output VGC with $45^{\circ}$ grating slant angle using holographic photopolymer(Dupont HRF600-20) for guided-wave optical interconnection applications, are presented. To show the usefulness of the proposed VGC, we fabricated the VGCs operating at 632.8nm and 1550nm wavelengths and its results are presented. The measured input coupling efficiency of the single VGC with $0.5{\mu}m$ grating period at 632.8nm wavelength is above 86.6% for TE-polarization. The input coupling efficiency of the $1\times2$ VGC with $0.73068{\mu}m$ grating period at 1550nm wavelength is about 90.8%.

  • PDF

Leakage Flow Influence on SHF pump model performances

  • Dupont, Patrick;Bayeul-Laine, Annie-Claude;Dazin, Antoine;Bois, Gerard;Roussette, Olivier;Si, Qiaorui
    • International Journal of Fluid Machinery and Systems
    • /
    • v.8 no.3
    • /
    • pp.193-201
    • /
    • 2015
  • This paper deals with the influence of leakage flow existing in SHF pump model on the analysis of internal flow behaviour inside the vane diffuser of the pump model performance using both experiments and calculations. PIV measurements have been performed at different hub to shroud planes inside one diffuser channel passage for a given speed of rotation and various flow rates. For each operating condition, the PIV measurements have been trigged with different angular impeller positions. The performances and the static pressure rise of the diffuser were also measured using a three-hole probe. The numerical simulations were carried out with Star CCM+ 9.06 code (RANS frozen and unsteady calculations). Some results were already presented at the XXth IAHR Symposium for three flowrates for RANS frozen and URANS calculations. In the present paper, comparisons between URANS calculations with and without leakages and experimental results are presented and discussed for these flow rates. The performances of the diffuser obtained by numerical calculations are compared to those obtained by the three-holes probe measurements. The comparisons show the influence of fluid leakages on global performances and a real improvement concerning the efficiency of the diffuser, the pump and the velocity distributions. These results show that leakage is an important parameter that has to be taken into account in order to make improved comparisons between numerical approaches and experiments in such a specific model set up.