• Title/Summary/Keyword: Duplex system

Search Result 290, Processing Time 0.023 seconds

A New Reduction Method of the Uplink Information for an Adaptive Modulation and Coding OFDM/FDD System (다중 사용자를 위한 적응형 OFDM/FDD 시스템의 상향링크 정보 축소 방안)

  • 장일순;유병한;조경록
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.2A
    • /
    • pp.140-146
    • /
    • 2004
  • In this paper we proposed the reducing method of feedback information for transmitting of adaptable data rate in multi-user OFDMA/FDD systems. In order to transmit downlink channel information to Base-Station(BS) through the limited uplink control channel, the proposed algorithm exploits the channel variation level which describes the similarity among the adjacent clusters and uses just one modulation and coding scheme(MCS) level representing channel information of all clusters'. We investigated the performance in single cell environment. It has a similar overhead for feedback information with conventional algorithm and has better performance in that bandwidth efficiency and outage probability than the conventional algorithms.

Compensations of Polarization Mode Dispersion and Thermal Drift in Optical Coherence Tomography with PZT Optical Delay Lines (광간섭 단층촬영(OCT)용 PZT 광경로 지연기에서의 편광모드 분산 및 열요동 보상)

  • Kim, Young-Kwan;Park, Sung-Jin;Kim, Yong-Pyung
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.6
    • /
    • pp.547-552
    • /
    • 2005
  • We have fabricated and characterized optical delay lines for optical coherence tomography, which is composed of cylindrical PZT(piezoelectric transducer) and single mode optical fiber. The polarization mode dispersion from the optical delay lines was compensated by the polarization controllers. By applying the duplex optical delay line, we minimized the thermal drift due to optical delay lines and obtained the scan range of 2 times that of a single optical delay line. The OCT system showed resolution of $18.6\pm0.5{\mu}m$, scanning range of 1.68mm, and scanning speed of 360.4mm/s.

A Study on the Improvement of Force Fighting Phenomenon in the Redundant Hydraulic Servo Actuators (다중 유압 서보 작동기의 force fighting 현상 개선에 관한 연구)

  • Lee, Hee-Joong;Choi, Hyung-Don;Kang, E-Sok
    • Aerospace Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.54-63
    • /
    • 2013
  • In general, multiple hydraulic servo actuators are installed on one control surface of aero-dynamically highly loaded condition aircraft for redundancy management to satisfy flight control safety requirements. If motions of multiple actuators are not synchronized, control surface is deformed from its free stressed state. In result, force fight conditions are generated on each actuator due to restoration reaction force of deformed control surface. In addition, force fight is induced from severe initial rigging tolerance. Force fight condition of multiple actuators affects control accuracies and reduces operational life of actuators and control surface due to fatigue phenomenon. In this study, we designed controller using force feedback to reduce force fight of duplex servo actuation system.

Computationally-Efficient Algorithms for Multiuser Detection in Short Code Wideband CDMA TDD Systems

  • De, Parthapratim
    • Journal of Communications and Networks
    • /
    • v.18 no.1
    • /
    • pp.27-39
    • /
    • 2016
  • This paper derives and analyzes a novel block fast Fourier transform (FFT) based joint detection algorithm. The paper compares the performance and complexity of the novel block-FFT based joint detector to that of the Cholesky based joint detector and single user detection algorithms. The novel algorithm can operate at chip rate sampling, as well as higher sampling rates. For the performance/complexity analysis, the time division duplex (TDD) mode of a wideband code division multiplex access (WCDMA) is considered. The results indicate that the performance of the fast FFT based joint detector is comparable to that of the Cholesky based joint detector, and much superior to that of single user detection algorithms. On the other hand, the complexity of the fast FFT based joint detector is significantly lower than that of the Cholesky based joint detector and less than that of the single user detection algorithms. For the Cholesky based joint detector, the approximate Cholesky decomposition is applied. Moreover, the novel method can also be applied to any generic multiple-input-multiple-output (MIMO) system.

Sweet Spot Search of Antenna Beam using The Two ADALINE (두개의 ADALINE을 이용한 안테나 빔의 스위트 스폿 탐색)

  • Lee, Chang-Young;Choi, Kyu-Min;Kang, Seong-Ho;Chung, Sung-Boo;Eom, Ki-Hwan
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • v.9 no.1
    • /
    • pp.705-708
    • /
    • 2005
  • In this paper, we propose a method that search the sweet spot of antenna beam, and keep it for fast speed transmission in millimeter wave on point-to-point link We use TDD(Time Division Duplex) as transfer method, and it transfers the control data of antenna. The proposed method is composed of two ADALINE which used the parallel. The efficiency of the proposed method is verified by means of simulations with white Gaussian noise and not on point-to-point link.

  • PDF

Effect of bolt preloading on rotational stiffness of stainless steel end-plate connections

  • Yuchen Song;Brian Uy
    • Steel and Composite Structures
    • /
    • v.48 no.5
    • /
    • pp.547-564
    • /
    • 2023
  • This study investigates the effect of bolt preloading on the rotational stiffness of stainless steel end-plate connections. An experimental programme incorporating 11 full-scale joint specimens are carried out comparing the behaviours of fully pre-tensioned (PT) and snug-tightened (ST) flush/extended end-plate connections, made of austenitic or lean duplex stainless steels. It is observed from the tests that the presence of bolt preloading leads to a significant increase in the rotational stiffness. A parallel finite element analysis (FEA) validated against the test results demonstrates that the geometric imperfection of end-plate has a strong influence on the moment-rotation response of preloaded end-plate connections, which is crucial to explain the observed "two-stage" behaviour of these connections. Based on the data obtained from the tests and FE parametric study, the performance of the Eurocode 3 predictive model is evaluated, which exhibits a significant deviation in predicting the rotational stiffness of stainless steel end-plate connections. A modified bi-linear model, which incorporates three key properties, is therefore proposed to enable a better prediction. Finally, the effect of bolt preloading is demonstrated at the system (structure) level considering the serviceability of semi-continuous stainless steel beams with end-plate connections.

Impedance investigation of the surface film formed on aluminum alloy exposed to nuclear reactor emergency core coolant

  • Junlin Huang;Derek Lister;Xiaoliang Zhu;Shunsuke Uchida;Qinglan Xu
    • Nuclear Engineering and Technology
    • /
    • v.55 no.4
    • /
    • pp.1518-1527
    • /
    • 2023
  • A method was proposed for in-situ evaluating the thickness and resistivity of the oxide/hydroxide film formed on the surface of aluminum alloy exposed to sump water formed in the containment after a loss-of-coolant accident. The evaluation entailed fitting a model for the film impedance, which has film thickness and other variables describing the resistivity profile of the film along its thickness direction as fitting parameters, to the practically measured electrochemical impedance data. The obtained resistivity profiles implied that the films formed at pHs25℃ 7, 8, 9, 10, and 11 all had a duplex structure; compared to the outer layer in contact with the solution, the inner layer of the film had a much higher resistivity and was inferred to be denser and provide most of the protectiveness of the film. Both the thickness and the total resistance of the film decreased with the increasing solution pH25℃, suggesting that the films formed in more alkaline solutions had less protectiveness against corrosion, consistent with the increasing aluminum alloy corrosion rates previously identified.

Reply-Type based Agent Generation of Legacy Service on One-way data transfer system (일방향 자료전달 시스템의 레거시 서비스 지원을 위한 응답구조 기반 에이전트 자동 생성)

  • Kim, Kyoung-Ho;Chang, Yeop;Kim, Hee-Min;Yun, Jeong-Han;Kim, Woo-Nyon
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.23 no.2
    • /
    • pp.299-305
    • /
    • 2013
  • Physical One-way Transfer, one of network Separating Network Technologies, shut off intrusion possibilities by removing data transfer line from external network to internal network. Physical One-way Transfer technology can not support legacy services based duplex transmission. Legacy services operating need agent for extra service with the support. But, Agent development have problems with adding cost and open internal protocols. In this papers, We analyzed legacy services between Control network and OA network in working SCADA systems, and based on the results obtained from the analysis, categorized the legacy services into three forms. We propose an agent generation method of the three service categories for Physical One-Way Transfer System. In addition, we design an automatic generation tool using the proposed method.

A Study on Prevention of Collision and Data Loss of the RFID System Using a Full-Length Instruction Code Method (무선인식 시스템의 완전 명령 코드 기법을 이용한 데이터 충돌 및 손실 방지에 관한 연구)

  • 강민수;신석균;이재호;박면규;이기서
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.7A
    • /
    • pp.756-765
    • /
    • 2004
  • Using single carrier frequency RFID system in one-to-multiple wireless communications, might be generated data loss because of data collisions. Conventional Anti-collision method prevent data loss from data collisions which are binary tree method and ALOHA. However, those two preventive measures also have week points which are strongly dependent on the time and space when passing through the recognition area. This paper suggests the full-length instruction code method which fits in to half-duplex method, prevents data collision effectively by calculating the non-transmitting time of multiple tags considering approaching time to the recognition area. After full-length instruction code method test using 13.56MHz bandwidth RFID system shows that full-length instruction code method could make better result than any other methods. Moreover, the record shows O(n) result after analyzing O-notation of conventional time-domain procedure.

System Design of SIGMA(KHUSAT-3) CubeSat Mission

  • Lee, Seongwhan;Lee, Junkyu;Kum, Kanghoon;Lee, Hyojeong;Seo, Junwon;Shin, Youra;Jeong, Seonyoung;Shin, Jehyuck;Cheon, Junghoon;Kim, Hanjun;Jin, Ho;Nam, Uk-Won;Kim, Sunghwan;Lee, Regina;Lessard, Marc R.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.1
    • /
    • pp.54.1-54.1
    • /
    • 2014
  • Kyung Hee University has been developing a CubeSat for the space science mission called SIGMA (Scientific cubesat with Instrument for Global Magnetic field and rAdiation), which includes TEPC (Tissue Equivalent Proportional Counter) and a magnetometer. SIGMA has a 3-unit CubeSat, and the weight is about 3.2 kg. The main payload is TEPC which can measure the Linear Energy Transfer (LET) spectrum and calculate the equivalent dose for the complicated radiation field in the space. The magnetometer is a secondary payload using a miniaturized fluxgate magnetometer. We expect it to have a 1 nT resolution in the dynamic range of ${\pm}65535$ nT. An Attitude Control System (ACS) spins the SIGMA spacecraft 4 rpm with the spin axis perpendicular to the ecliptic plane. Full duplex communication is consists of VHF uplink and S-band and UHF downlink. In this paper, we introduce the system design and the scientific purpose of the SIGMA CubeSat mission.

  • PDF