• 제목/요약/키워드: Ductility capacity

검색결과 1,030건 처리시간 0.029초

Axial behavior of square CFST encased seawater sea-sand concrete filled PVC/GFRP tube columns

  • Rong Su;Xian Li;Ziwei Li
    • Steel and Composite Structures
    • /
    • 제47권6호
    • /
    • pp.781-794
    • /
    • 2023
  • In order to directly apply seawater and sea sand in construction without desalination, a type of square concrete-filled steel tube (CFST) encased with prefabricated seawater sea-sand concrete filled Polyvinyl Chloride (PVC)/Glass Fiber Reinforced Polymer (GFRP) tube column was proposed. Twenty short columns were tested under uniaxial loads, and the test parameters included inner tube types, seawater sea-sand concrete replacement ratios, concrete strength, the wrapping area of Carbon Fiber Reinforced Polymer (CFRP) strips and the thickness of GFRP tube. The effects of the parameters on failure modes, loading capacity, ductility and strain responses were discussed. All the tested specimens failed with serious buckling of the steel tubes and fracture of the inner tubes. The specimens had good residual bearing capacity corresponding to 64% to 88.9% of the peak capacity. The inner GFRP tubes and PVC tubes wrapped by CFRP strips provided stronger confinement to the core concrete, and were good choices for the proposed columns. Moreover, an analytical model for the composite column with different inner tube types was proposed.

Hysteretic performance of the all-steel buckling-restrained brace with LY315 steel core

  • Wei, Xuan;Yang, Lu;Chen, Yohchia Frank;Wang, Meng
    • Steel and Composite Structures
    • /
    • 제44권6호
    • /
    • pp.899-912
    • /
    • 2022
  • To study the seismic performance of the all-steel buckling-restrained brace (BRB) using the novel soft steel LY315 for core member, a total of three identical BRBs were designed and a series of experimental and numerical studies were conducted. First, monotonic and cyclic loading tests were carried out to obtain the mechanical properties of LY315 steel. In addition, the parameters of the Chaboche model were calibrated based on the test results and then verified using ABAQUS. Second, three BRB specimens were tested under cyclic loads to investigate the seismic performance. The failure modes of all the specimens were identified and discussed. The test results indicate that the BRBs exhibit excellent energy dissipation capacity, good ductility, and excellent low-cycle fatigue performance. Then, a finite element (FE) model was established and verified with the test results. Furthermore, a parametric study was performed to further investigate the effects of gap size, restraining ratio, slenderness ratio of the yielding segment, and material properties of the core member on the load capacity and energy dissipation capacity of BRBs.

Mechanical behavior of HPFRCC using limestone calcined clay cement (LC3) and oxygen plasma treated PP fibers

  • Sajjad Mirzamohammadi;Masoud Soltani
    • Structural Engineering and Mechanics
    • /
    • 제89권4호
    • /
    • pp.349-362
    • /
    • 2024
  • High-performance fiber-reinforced cement composites (HPFRCC) are new materials created and used to repair, strengthen, and improve the performance of different structural parts. When exposed to tensile tension, these materials show acceptable strain-hardening. All of the countries of the globe currently seem to have a need for these building materials. This study aims to create a low-carbon HPFRCC (high ductility) that is made from materials that are readily available locally which has the right mechanical qualities, especially an increase in tensile strain capacity and environmental compatibility. In order to do this, the effects of fiber volume percent (0%, 0.5%, 1%, and 2%), and determining the appropriate level, filler type (limestone powder and silica sand), cement type (ordinary Portland cement, and limestone calcined clay cement or LC3), matrix hardness, and fiber type (ordinary and oxygen plasma treated polypropylene fiber) were explored. Fibers were subjected to oxygen plasma treatment at several powers and periods (50 W and 200 W, 30, 120, and 300 seconds). The influence of the above listed factors on the samples' three-point bending and direct tensile strength test results has been examined. The results showed that replacing ordinary Portland cement (OPC) with limestone calcined clay cement (LC3) in mixtures reduces the compressive strength, and increases the tensile strain capacity of the samples. Furthermore, using oxygen plasma treatment method (power 200 W and time 300 seconds) enhances the bonding of fibers with the matrix surface; thus, the tensile strain capacity of samples increased on average up to 70%.

Flexural performance of composite beams with open-web π-shaped steel partially-encased by concrete

  • Liusheng Chu;Yunhui Chen;Jie Li;Yukun Yang;Danda Li;Xing Ma
    • Steel and Composite Structures
    • /
    • 제50권4호
    • /
    • pp.419-428
    • /
    • 2024
  • Prefabricated partially-encased composite (PEC) structural component is widely used in construction industry due to its superior structural performance and easy assembly characteristic. However, the solid web in traditional PEC components tends to split concrete into two halves, thus potentially reduces structural integrity and requires double concrete pouring. To overcome the above disadvantages, a new PEC beam with open-web π-shaped steel is proposed in this paper. Four open-web PEC beams with varying sectional height, flange thickness and web void rate were constructed and tested under flexural loads. During experimental tests, all beams exhibited typical flexural failure modes with strong moment capacities and excellent ductility. Owing to the unique construction form of web opening, steel-concrete bonding properties were enhanced and very small relative steel-concrete slips were observed. Experimental results also showed that the flexural capacity of such PEC beams increased with the increase of the sectional height and flange thickness, while was not affected by the web void rate. At last, a flexural capacity formula of the open-web PEC beam was proposed based on the whole section plastic rule. The formula results agreed well with experimental results.

Research on seismic performance of regionally confined concrete circular column with trapezoid stirrups

  • Longfei Meng;Hao Su;Yanhua Ye;Haojiang Li
    • Steel and Composite Structures
    • /
    • 제51권6호
    • /
    • pp.587-600
    • /
    • 2024
  • In order to investigate the seismic performance of regionally confined concrete circular column with trapezoid stirrups (TRCCC) under high axial compression ratio, the confinement mechanism of regionally confined concrete was analyzed. Three regionally confined concrete circular columns with trapezoid stirrups were designed, and low cyclic loading tests were conducted at three different axial compression ratios (0.9, 1.1, 1.25) to study the failure mode, hysteresis curve, skeleton curve, deformation capacity, stiffness degradation and energy dissipation capacity of the specimens. The results indicate that the form of regional confinement concrete provides more uniform confinement to the normal confinement, and the confinement efficiency at the edges is 1.4 times that of normal confined concrete. The ductility coefficients of the specimens were all greater than 3 under high axial compression ratios, and the stiffness and horizontal bearing capacity increased with the increase of axial compression ratio. Therefore, it is recommended that the code of design specifications can appropriately relax the axial compression ratio limit for TRCCC. Finally, the spacing between stirrups of TRCCC was analyzed using ABAQUS software. The results showed that as the spacing between the stirrups decreased, the cracking load and peak load of TRCCC increased continuously, but the rate of increase decreases.

섬유시트와 매입형 CFRP Rod를 보강한 R/C 외부 보-기둥 접합부의 내진성능 평가 및 개선 (Improvement and Evaluation of Seismic Performance of Reinforced Concrete Exterior Beam-Column Joints Retrofitting with Fiber Reinforced Polymer Sheets and Embedded CFRP Rods)

  • 하기주;하영주;강현욱
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제19권2호
    • /
    • pp.151-159
    • /
    • 2015
  • 본 연구에서는 기존 철근콘크리트 구조물 보-기둥 접합부의 내진성능의 개선을 위해 보-기둥 접합부 영역을 FRP보강재 (탄소섬유시트, 아라미드섬유시트, 매입형 CFRP Rod)를 사용하여 보강한 후 내진성능을 평가하였다. 총 7개의 실험체를 제작하고 실험을 수행하여 내진성능을 평가하였으며, 본 연구의 실험결과를 근거로 다음과 같은 결론을 얻었다. 기존 철근콘크리트 보-기둥 접합부의 접합부 영역을 보강한 결과, 초기 재하시 접합부 영역의 균열억제 효과와 재하 전 과정을 통하여 보강재의 구속효과로 인하여 균열억제 효과가 커서 안정적인 파괴형태 및 내력향상 효과를 나타내었다. 매입형 CFRP Rod와 탄소섬유시트를 활용한 R/C 외부 보-기둥 접합부 실험체 LBCJ-CRUS는 표준실험체 LBCJ와 비교하여 변위연성 4, 7에서 각각 최대내력은 1.54배, 에너지소산능력은 2.36배 증가하였다. 그리고 실험체 LBCJ-CS, LBCJ-AF시리즈는 변위연성 7에서 표준실험체 LBCJ 보다 에너지소산능력이 각각 2.04~2.34, 1.63~3.02배 증가하였다.

철근콘크리트 프레임 및 전단벽체의 경계기둥 띠철근비 변화에 따른 구조성능 평가 (Structural Performance Evaluation of Reinforced Concrete Frame and Shear Wall with Various Hoop Ratios of Boundary Column)

  • 신종학;하기주;전찬목
    • 콘크리트학회지
    • /
    • 제10권6호
    • /
    • pp.303-311
    • /
    • 1998
  • 본 연구는 수직하중과 정.부 수평하중이 동시에 작용하는 순수강접 프레임과 완전강접 바벨형 철근콘크리트 전단벽 시험체의 경계기둥 띠철근비를 주요변수로 하여 총 10개의시험체를 실물 크기의 약 1/3로 축소 모델화하여 제작한 후, 구조성능 평가를 위한 실험을 실시하여 이력거동 특성, 수평강성 및 최대내력,파괴형태, 연성능력등을 비교 고찰하여 다음과 같은 결론을 얻었다. 순수강접 프레임 및 완전강접 바벨형 전단벽 시헴체의 경우, 각 시험체의 실험을 통하여 구한 이력거동곡선을 비교 고찰한 결과 기둥의 띠철근비가 클수록 최대하중에 도달한 후 강도저하 현상이 서서히 진행되었고, 연성적인 파괴형태를 나타내었다. 완전강접 바벨형 전단벽 시험체의 경우, 좌우기둥의 띠철근비가 적은 시험체는 비교적 띠철근비가 큰 시험체에 비하여 최종 파괴시의 파괴형태는 사인장 균열에 의해 지배됨을 규명할 수 있었다. 완전강접 바벨형 전단벽 시험체의 초대수평내력은 순수강접 프레임 시험체의최대수평내력보다 약 5.47~7.95배 증가하였다.

프리스트레스트 경량 콘크리트 보의 휨 거동에 대한 부분 프리스트레싱비와 유효 프리스트레스의 영향 (Effect of Partial Prestressing Ratio and Effective Prestress on the Flexural Behavior of Prestressed Lightweight Concrete Beams)

  • 양근혁;문주현;변항용
    • 콘크리트학회논문집
    • /
    • 제23권1호
    • /
    • pp.39-48
    • /
    • 2011
  • 이 연구에서는 상부 2점 집중하중을 받는 프리텐션 경량 콘크리트 보의 휨 거동을 부분 프리스트레싱 비와 긴장재의 유효 프리스트레스에 따라 평가하였다. 절건비중 1,770 $kg/m^3$의 경량 콘크리트 설계강도는 35 MPa이었으며, 항복강도 383 MPa의 일반 이형철근과 인장강도 2,040 MPa의 3연선을 각각 주 인장철근과 프리스트레싱 긴장재로 사용하였다. 실험 결과, 프리텐션 경량 콘크리트 보의 휨 내력은 부분 프리스트레싱 비의 증가와 함께 증가하지만 긴장재의 유효 프리스트레스에는 거의 영향을 받지 않았다. 동일 휨 보강지수에서 프리텐션 경량 콘크리트 보의 무차원 휨 내력은 Harajli and Naaman 및 Bennet에 의해 실험된 프리텐션 보통중량 콘크리트 보와 비슷한 수준이었다. 한편 프리텐션 경량 콘크리트 보의 변위 연성비는 부분 프리스트레싱 비의 감소와 함께 그리고 유효 프리스트레스의 증가와 함께 증가하였다. 프리텐션 경량 콘크리트 보의 하중-변위 관계는 비선형 2차원 해석모델에 의해 적절하게 평가될 수 있었다. 또한 프리텐션 경량 콘크리트 보의 휨 균열 내력 및 최대 휨 내력은 각각 탄성이론 및 ACI 318-08의 등가응력블록과 긴장재의 응력평가 식을 이용하여 안전측에서 예측될 수 있었다.

지진하중을 받는 철근콘크리트 원형교각의 전단성능곡선 모델 (Shear Capacity Curve Model for Circular RC Bridge Columns under Seismic Loads)

  • 이재훈;고성현;정영수
    • 한국지진공학회논문집
    • /
    • 제10권2호
    • /
    • pp.1-10
    • /
    • 2006
  • 형상비가 상대적으로 작은 철근콘크리트 교각에 지진작용으로 인한 반복 횡하중이 작용하면 초기단계와 중간단계의 변위에서는 휨 거동을 보이다가 최종변위단계에서는 전단에 의해 파괴되는 휨-전단 거동을 보인다. 휨-전단 파괴거동을 보이는 교각은 휨 파괴거동을 보이는 교각에 비하여 연성능력이 저하되므로, 내진설계 또는 내진성능평가에서 극한변위를 해석적으로 결정하기 위해서는 휨성능곡선과 함께 전단성능곡선 모델을 적용하여야 한다. 본 논문에서는 원형교각에 대한 기존 모델을 수정한 전단성능곡선 모델을 제안하였고, CALTRANS 모델, Aschheim등의 모델, Priestley 등의 모델, 제안모델의 특징을 비교하였다. 또 국내에서 수행된 실물크기 기둥 실험체를 대상으로 전단성능곡선 모델을 평가하였다. 제한된 범위의 소수 실험결과에 대한 적용으로서 일반화하기는 어려울 것이지만, 실험결과와 비교 검토한 결과 제안모델이 파괴형태의 예측과 변위성능 예측의 정확도에서 매우 우수한 것으로 평가되었다.

Cyclic behavior of steel beam-concrete wall connections with embedded steel columns (II): Theoretical study

  • Li, Guo-Qiang;Gu, Fulin;Jiang, Jian;Sun, Feifei
    • Steel and Composite Structures
    • /
    • 제23권4호
    • /
    • pp.409-420
    • /
    • 2017
  • This paper theoretically studies the cyclic behavior of hybrid connections between steel coupling beams and concrete shear walls with embedded steel columns. Finite element models of connections with long and short embedded steel columns are built in ABAQUS and validated against the test results in the companion paper. Parametric studies are carried out using the validated FE model to determine the key influencing factors on the load-bearing capacity of connections. A close-form solution of the load-bearing capacity of connections is proposed by considering the contributions from the compressive strength of concrete at the interface between the embedded beam and concrete, shear yielding of column web in the tensile region, and shear capacity of column web and concrete in joint zone. The results show that the bond slip between embedded steel members and concrete should be considered which can be simulated by defining contact boundary conditions. It is found that the loadbearing capacity of connections strongly depends on the section height, flange width and web thickness of the embedded column. The accuracy of the proposed calculation method is validated against test results and also verified against FE results (with differences within 10%). It is recommended that embedded steel columns should be placed along the entire height of shear walls to facilitate construction and enhance the ductility. The thickness and section height of embedded columns should be increased to enhance the load-bearing capacity of connections. The stirrups in the joint zone should be strengthened and embedded columns with very small section height should be avoided.