• Title/Summary/Keyword: Ductility Reduction Factor

Search Result 59, Processing Time 0.026 seconds

철근콘크리트 벽식 구조물의 반응수정계수 평가에 관한 연구 (Evaluation of the Response Modification Factor for RC Wall-type Structures)

  • 한상환;이리형;오영훈;천영수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 봄 학술발표회논문집(II)
    • /
    • pp.433-438
    • /
    • 1998
  • Design lateral strength calculated by current seismic design code is prescribed to be much lower than the force level required for a structure to respond elastically during design level earthquake ground motion. Present procedures for calculating seismic design forces are based on the use of elastic spectra reduced by a strength reduction factor known as "response modification factor, R". This factor accounts for the inherent ductility, overstrength, redundancy, and damping of a structural system. This study considers ductility and overstrength of the wall-type structure for investigating R factor. This means that R factor is determined from the product of "ductility-based R factor($R_$\mu$$) and overstrength factor($R_s$). $R_$\mu$$ factor is calibrated to attain the targer ductility ratio (system ductility capacity) and produced in the from of $R_$\mu$$ spectra considering the influence of target ductility, natural period, and hysteretic model. On the other hand, $R_s$ is more difficult to quantify, since it depends on both material and system-dependent uncertain parameters. In this study Rs factor was determined from the result of push-over analysis.-over analysis.

  • PDF

Soil structure interaction effects on strength reduction factors

  • Eser, Muberra;Aydemir, Cem;Ekiz, Lbrahim
    • Structural Engineering and Mechanics
    • /
    • 제41권3호
    • /
    • pp.365-378
    • /
    • 2012
  • In this study, strength reduction factors are investigated for SDOF systems with period range of 0.1-3.0 s with elastoplastic behavior considering soil structure interaction for 64 different earthquake motions recorded on different site conditions such as rock, stiff soil, soft soil and very soft soil. Soil structure interacting systems are modeled and analyzed with effective period, effective damping and effective ductility values differing from fixed-base case. For inelastic time history analyses, Newmark method for step by step time integration was adapted in an in-house computer program. Results are compared with those calculated for fixed-base case. A new equation is proposed for strength reduction factor of interacting system as a function of structural period of system (T), ductility ratio (${\mu}$) and period lengthening ratio (T/T). It is concluded that soil structure interaction reduces the strength reduction factors for soft soils, therefore, using the fixed-base strength reduction factors for interacting systems lead to non-conservative design forces.

인장지배영역에서의 철근콘크리드 기둥의 연성에 관한 해석적 연구 (An Analytical Study on Ductility of Reinforced Concrete Columns under Tension Controlled Region)

  • 손혁수;김준범;이재훈
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1997년도 가을 학술발표회 논문집
    • /
    • pp.527-532
    • /
    • 1997
  • Design strength of structural members could be determined by applying a strength reduction factor to nominal strength. At the beginning point of the transition region for the strength reduction factor, P=0.1$\sigma$$_{ck}A_g$, only sectional area and concrete strength are adopted as the variables of P=0.1$\sigma$$_{ck}A_g$. Therefore, P=0.1$\sigma$$_{ck}A_g$ is the empirically adopted which does not consider steel ratio, steel yielding stress, and steel arrangement. So, this research was perpormed the computer program for the analysis of axial force-moment-curvature relationship of reinforced concrete columns by sectional behaviour nonlinear analysis using a concrete compressive stress-strain curve, in order to investigate the ductility of reinforced concrete columns. As a result, ductility indicies of axial force, P=0.1$\sigma$$_{ck}A_g$, represented the lack of consistency of the indicies value for the various sections.

  • PDF

현행 내진설계 규준의 수평강도 요구에 대한 평가 (Evaluation of the Strength Required in Current Seismic Design Code)

  • 한상환;오영훈;이리형
    • 전산구조공학
    • /
    • 제10권4호
    • /
    • pp.281-290
    • /
    • 1997
  • 현행 내진설계 규준에서 사용하고 있는 반응수정계수는 설계지진하중과 유사한 지진발생시 구조물이 비선형 거동을 하도록 탄성응답에서 요구되는 밑면전단력 값을 낮추는 계수라 할 수 있다. 따라서 반응수정계수는 하중저감계수(force reduction factor)라고 할 수 있으며, 이러한 값들은 경험적으로 결정된 것이어서 예상지진에 대하여 구조설계자가 설계한 건물이 어느정도의 비선형 거동을 할지는 예측하기가 힘들다. 본 연구에서는 목표가 되는 연성비(target ductility ratio)에 따라 요구되는 밑면전단력의 값을 구하고 이를 규준에서 요구하는 값과 비교할 것이다. 만약 요구되는 값이 규준 값 보다 크다면 이는 구조물이 가지는 부가강도(overstrength)나 잉여력(redundancy)이 담당해야 한다. 모멘트연성골조 건물을 설계한 후 이를 push-over 해석에 의하여 부가강도를 찾아 보아 요구강도와 비교할 것이다.

  • PDF

Ductility-based design approach of tall buildings under wind loads

  • Elezaby, Fouad;Damatty, Ashraf El
    • Wind and Structures
    • /
    • 제31권2호
    • /
    • pp.143-152
    • /
    • 2020
  • The wind design of buildings is typically based on strength provisions under ultimate loads. This is unlike the ductility-based approach used in seismic design, which allows inelastic actions to take place in the structure under extreme seismic events. This research investigates the application of a similar concept in wind engineering. In seismic design, the elastic forces resulting from an extreme event of high return period are reduced by a load reduction factor chosen by the designer and accordingly a certain ductility capacity needs to be achieved by the structure. Two reasons have triggered the investigation of this ductility-based concept under wind loads. Firstly, there is a trend in the design codes to increase the return period used in wind design approaching the large return period used in seismic design. Secondly, the structure always possesses a certain level of ductility that the wind design does not benefit from. Many technical issues arise when applying a ductility-based approach under wind loads. The use of reduced design loads will lead to the design of a more flexible structure with larger natural periods. While this might be beneficial for seismic response, it is not necessarily the case for the wind response, where increasing the flexibility is expected to increase the fluctuating response. This particular issue is examined by considering a case study of a sixty-five-story high-rise building previously tested at the Boundary Layer Wind Tunnel Laboratory at the University of Western Ontario using a pressure model. A three-dimensional finite element model is developed for the building. The wind pressures from the tested rigid model are applied to the finite element model and a time history dynamic analysis is conducted. The time history variation of the straining actions on various structure elements of the building are evaluated and decomposed into mean, background and fluctuating components. A reduction factor is applied to the fluctuating components and a modified time history response of the straining actions is calculated. The building components are redesigned under this set of reduced straining actions and its fundamental period is then evaluated. A new set of loads is calculated based on the modified period and is compared to the set of loads associated with the original structure. This is followed by non-linear static pushover analysis conducted individually on each shear wall module after redesigning these walls. The ductility demand of shear walls with reduced cross sections is assessed to justify the application of the load reduction factor "R".

Seismic force reduction factor for steel moment resisting frames with supplemental viscous dampers

  • Serror, M. Hassanien;Diab, R. Adel;Mourad, S. Ahmed
    • Earthquakes and Structures
    • /
    • 제7권6호
    • /
    • pp.1171-1186
    • /
    • 2014
  • Damping is one of the parameters that control the performance of structures when they are subjected to seismic, wind, blast or other transient shock and vibration disturbances. By adding supplemental viscous dampers, the energy input from a transient deformation is absorbed, not only by the structure itself, but also by the supplemental dampers. The aim of this study is to evaluate the values of both damping and ductility reduction factors for steel moment resisting frames with supplemental linear viscous dampers. Two-dimensional finite element models have been established for a range of low to mid rise buildings with different parameters: number of floors; number of bays; and number of dampers with different supplemental damping ratios (from 5% to 30%). A parametric study has been performed using time history analyses and a well-documented research method (N2-method). In addition, an equation has been proposed for each reduction factor based on regression analysis for the obtained results. The results of the Time history analyses are compared with those of a modified N2-method. Moreover, a comparison with values specified in the European code EC8 and the Egyptian code ECP-201 has been performed.

Strength reduction factor for multistory building-soil systems

  • Nik, Farhad Abedi;Khoshnoudian, Faramarz
    • Earthquakes and Structures
    • /
    • 제6권3호
    • /
    • pp.301-316
    • /
    • 2014
  • This paper is devoted to investigate the effects of SSI on strength reduction factor of multistory buildings. A new formula is proposed to estimate strength reduction factors for MDOF structure-soil systems. It is concluded that SSI reduces the strength reduction factor of MDOF systems. The amount of this reduction is relevant to the fundamental period of structure, soil flexibility, aspect ratio and ductility of structure, and could be significantly different from corresponding fixed-base value. Using this formula, measuring the amount of this error could be done with acceptable accuracy. For some practical cases, the error attains up to 50%.

An investigation of seismic parameters of low yield strength steel plate shear walls

  • Soltani, Negin;Abedi, Karim;Poursha, Mehdi;Golabi, Hassan
    • Earthquakes and Structures
    • /
    • 제12권6호
    • /
    • pp.713-723
    • /
    • 2017
  • Steel plate shear walls (SPSWs) are effective lateral systems which have high initial stiffness, appropriate ductility and energy dissipation capability. Recently, steel plate shear walls with low yield point strength (LYP), were introduced and they attracted the attention of designers. Structures with this new system, besides using less steel, are more stable. In the present study, the effects of plates with low yield strength on the seismic design parameters of steel frames with steel plate shear walls are investigated. For this purpose, a variety of this kind of structures with different heights including the 2, 5, 10, 14 and 18-story buildings are designed based on the AISC seismic provisions. The structures are modeled using ANSYS finite element software and subjected to monotonic lateral loading. Parameters such as ductility (${\mu}$), ductility reduction ($R_{\mu}$), over-strength (${\Omega}_0$), displacement amplification ($C_d$) and behavior factor (R) of these structures are evaluated by carrying out the pushover analysis. Analysis results indicate that the ductility, over-strength and behavior factors decrease by increasing the number of stories. Also, the displacement amplification factor decreases by increasing the number of stories. Finally, the results were compared with the suggestions provided in the AISC code for steel plate shear walls. The results indicate that the values for over-strength, behavior and displacement amplification factors of LYP steel plate shear wall systems, are larger than those proposed by the AISC code for typical steel plate shear wall systems.

역량스펙트럼 방법을 이용한 철근 콘크리트 교각의 내진성능 평가 (Evaluation of Seismic Performance for Reinforced Concrete Piers Using Capacity Spectrum Method)

  • 송종걸;장동휘;정영화
    • 산업기술연구
    • /
    • 제24권A호
    • /
    • pp.185-194
    • /
    • 2004
  • To evaluate seismic performance of reinforced concrete piers two procedures for capacity spectrum method are presented. The capacity spectrum procedures include the reduction factor-ductility-period($R_{\mu}-{\mu}-T$)relationship in order to construct the inelastic demand spectra from the elastic demand spectra. Application of the procedures are illustrated by example analysis. Maximum displacements estimated by the procedures are compared to those by inelastic time history analysis for several artificial earthquakes. The results show that the maximum displacements estimated by the procedures are, on overall, smaller than those by the inelastic time history analysis.

  • PDF

Experimental and analytical investigations on seismic behavior of ductile steel knee braced frames

  • Zahrai, Seyed Mehdi;Jalali, Meysam
    • Steel and Composite Structures
    • /
    • 제16권1호
    • /
    • pp.1-21
    • /
    • 2014
  • Knee Braced Frame (KBF) is a special form of ductile eccentrically braced frame having a diagonal brace connected to a knee element, as a hysteretic damper, instead of beam-column joint. This paper first presents an experimental investigation on cyclic performance of two knee braced single span one-story frame specimens. The general test arrangement, specimen details, and most relevant results (failure modes and hysteretic curves) are explained. Some indexes to assess the seismic performance of KBFs, including ductility; response reduction factor and energy dissipation capabilities are also subsequently discussed. Experimental results indicate that the maximum equivalent damping ratios achieved by test frames are 21.8 and 23% for the specimens, prior to failure. Finally, a simplified analytical model is derived to predict the bilinear behavior of the KBFs. Acceptable conformity between analytical and experimental results proves the accuracy of the proposed model.