• Title/Summary/Keyword: Duct Model

Search Result 333, Processing Time 0.023 seconds

Development of Ventilation Duct Chamber for Reducing Space (공간 절약형 환기덕트를 위한 챔버 개발에 관한 연구)

  • Kim, Sang-Jin;Choi, Sang-Sik;Lee, Sung
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.535-539
    • /
    • 2008
  • The machinery ventilation system in case of using the window nature ventilation is difficult due to strong outdoor wind pressure is common ventilation measure. increasing height and decreasing economical efficiency problem because of ventilation duct installation is rising and a measure is urgent. The purpose of this study is analysis required height according to each ventilation system and development of ventilation duct system to reducing height and model testing.

  • PDF

Laminar Heat and Fluid Flow Characteristic with a Modified Temperature-Dependent Viscosity Model in a Rectangular Duct

  • Sohn Chang-Hyun;Chang Jae-Whan
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.3
    • /
    • pp.382-390
    • /
    • 2006
  • The present study proposes a modified temperature-dependent non-Newtonian viscosity model and investigates the flow characteristics and heat transfer enhancement of the viscoelastic non-Newtonian fluid in a 2:1 rectangular duct. The combined effects of temperature dependent viscosity, buoyancy, and secondary flow caused by the second normal stress difference are considered. Calculated Nusselt numbers by the modified temperature-dependent viscosity model give good agreement with the experimental results. The heat transfer enhancement of viscoelastic fluid in a rectangular duct is highly dependent on the secondary flow caused by the magnitude of second normal stress difference.

A PID Control of Supply Duct Outlet Air Temperature in Personal Environment Module

  • Park, Young-Chil
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.11 no.2
    • /
    • pp.82-90
    • /
    • 2003
  • The work presented here is a design and an implementation of PID control system to regulate a supply duct outlet air temperature in PEM (Personal Environment Module). In PEM, the air is heated to the required temperature while it flows through the supply duct without any mixing chamber. This makes the control of air temperature in PEM difficult. A simulation is done first to understand the relationship between a temperature distribution in working area, flow rate and the outlet air temperature of PEM. Then a linear dynamic model of heating process in PEM is derived. P, PD and PID type control systems, to provide the rapid response without overshoot and saturation in heater command voltage, are designed using a linear model obtained. Experimentally obtained data shows that the control system satisfies the design criteria and works properly in controlling the supply duct outlet air temperature.

CFD Analysis of Performance of KRISO Devices (K-DUCT) for Propulsion Efficiency Improvement (CFD를 이용한 KRISO 추진효율 향상 장치(K-duct)의 성능 해석)

  • Suh, Sung-Bu
    • Journal of Ocean Engineering and Technology
    • /
    • v.31 no.3
    • /
    • pp.183-188
    • /
    • 2017
  • This paper provides numerical results for the estimation of the efficiency of KRISO energy saving devices in the design stage. A finite volume method is used to solve Reynolds averaged Navier-Stokes (RANS) equations, where the SST k-$\omega$ model is selected for turbulence closure. The propeller rotating motion is determined using a rigid body motion (RBM) scheme, which is called a sliding mesh technique. The numerical analysis focuses on predicting the power reduction by the designed KRISO devices (K-DUCT) under a self-propulsion condition. The present numerical results show good agreement with the available experimental data. Finally, it is concluded that CFD can be a useful method, along with model tests, for assessing the performance of energy saving devices for propulsion efficiency improvement.

Comparative Study between Results of Theoretical Calculation and Model Test for Performance Confirmation of "Crown Duct"

  • Lee, Kwi-Joo;An, Jung-Sun;Kwak, Han-Joung
    • Journal of Ocean Engineering and Technology
    • /
    • v.28 no.1
    • /
    • pp.1-5
    • /
    • 2014
  • Chosun University, in cooperation with SPP shipyard, has developed an energy saving device based on a new concept: "Crown Duct." Crown Duct is composed of a semi-duct with short struts inside and outside the duct. Theoretical calculations for two different designs were carried out using the CFD code "Ship Flow." The design selected from these two different forms by the CFD code analysis was tested in a towing tank at SSPA. The results showed about 4% efficiency gain under a full-load condition and about 7% gain under a ballast condition in the towing tank test.

Performance Improvement of Fan and Duct System for Kimchi Refrigerator (김치 냉장고용 홴 및 덕트 시스템 성능 개선)

  • Kim, Joon-Hyung;Choi, Young-Seok;Yoon, Joon-Yong;Park, Sung-Kwan;Hyun, Seok-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.14 no.4
    • /
    • pp.45-51
    • /
    • 2011
  • The kimchi refrigerator is the electronic home appliance which is used for the maturing and a custody of the kimchi. In this paper, performance improvement of fan and duct system for kimchi refrigerator has been studied by using a commercial CFD code. In order to achieve a improved fan performance, three-dimensional computational fluid dynamics and the Design of Experiments method have been applied. Additionally, to know the optimized duct inlet shape with the optimized fan, the overall performances were calculated with various duct inlet shapes. The final fan and duct system for kimchi refrigerator showed improved performance in efficiency and total head compared with the existing model.

Flow Control Analysis of S-duct Diffuser Inlet

  • Lian, Xiaochun;Zhang, Lifen;Wu, Dingyi
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.03a
    • /
    • pp.157-159
    • /
    • 2008
  • An numerical investigation of the flow characteristics inside a diffusing S-duct inlet with and without vortex generators(VGs) was conducted. The primary discussion herein focuses on development of secondary flow in the S-duct with and without VGs, pressure recovery and distortion at the exit are also discussed. Full three-dimensional Navier-Stokes equations are solved using finite volume method and $k-\varepsilon$ turbulence model is employed. In order to validate the credibility of the numerical methods, predicted results of surface pressure are compared with flight test for the S-duct inlet without VGs, and it shows fairly good agreement. The result shows that VGs alter the flow characteristics in the S-duct and are effective in reducing distortion and ineffective in improving pressure recovery.

  • PDF

The Changes of Temperature for Embedded Duct Ventilation System in Ondol (바닥온돌 매립형 환기덕트시스템의 온도변화에 대한 고찰)

  • Kim, Ok;Park, Jin-Chul;Kim, Nam-Gyu;Oh, Jae-Keun
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.375-380
    • /
    • 2006
  • Embedded Duct Ventilation System in Ondol is embedded supply duct in Ondol. This system allows heat up outside air to inside temperature with out using heat exchanger and electric heating coiling in winter season. In this research, we measured temperature of inside and surface of Ondol, supply duct, and supply air temperature incorporate embedded duct ventilation system in Ondol in model house($110m^2$) & one room($23m^2$)

  • PDF

Study on Measurement and Numerical Analysis for Fluid Flow past a Circular Cylinder in Rectangular Duct (사각던트 내에서 원형 실린더를 지나는 유체유동의 측정 및 수치해석에 관한 연구)

  • 김경환;윤영환
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.12
    • /
    • pp.1095-1102
    • /
    • 2003
  • Flow characteristics of turbulent steady fluid flow past a cylinder in rectangular duct are measured by 5 W laser doppler velocity meter. The fluid flow is also computed by commercial software of STAR-CD for comparison between the measurement and computation. The turbulent models applied in the computations are standard K-epsilon model, RNG K-epsilon model and Chen K-epsilon model. Acurracy of standard K-epsilon model is a little bit better than acurracies of other models even though those models have almost the same order of error compared to measured data. The computations predict satisfactorily the measured velocity profiles at middle section of the circular cylinder before the fluid flow diverges. However, there are some disagreements between them at down stream from the circular cylinder.

Three-Dimensional Numerical Simulation on a Circular-to-Rectangular Transition Duct (Circular-to-Rectangular Transition Duct 에서의 3차원 유동장에 관한 연구)

  • Cho Soo-Yong;Son Ho-Jae
    • 한국전산유체공학회:학술대회논문집
    • /
    • 1998.11a
    • /
    • pp.55-61
    • /
    • 1998
  • The purpose of this study is to compare the predictive behaviors of the extended $k-{\varepsilon}$ turbulence model and the standard $k-{\varepsilon}$ turbulence model. Grid dependency is tested with the H-type grid and the O-type grid. Computations have been performed for a circular-to-rectangular transition duct. Numerical results for several sections along the streamwise have been obtained to compare with experimental results. The Reynolds number is 390,000 based on the bulk velocity at the inlet. The computed axial velocity contours, transverse velocity profiles, static pressure contours, peripheral skin friction coefficient, and peripheral wall static pressure distributions have been compared with experimental results. The computed results obtained with the extended $k-{\varepsilon}$ turbulence model show better agreement with experimental results than those obtained with the standard $k-{\varepsilon}$ turbulence model. Comparing to the computed results obtained with the H-type grid and O-type grid, those with H-type grid agree well with experimental results.

  • PDF