• Title/Summary/Keyword: Duck house

Search Result 42, Processing Time 0.024 seconds

Assessment of Evaporation Rates from Litter of Duck House (오리사 바닥재의 수분 증발량 평가)

  • Lee, Sang-Yeon;Lee, In-Bok;Kim, Rack-Woo;Yeo, Uk-Hyeon;Decano, Cristina;Kim, Jun-gyu;Choi, Young-Bae;Park, You-Me;Jeong, Hyo-Hyeog
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.61 no.5
    • /
    • pp.101-108
    • /
    • 2019
  • The domestic duck industry is the sixth-largest among the livestock industries. However, 34.3% of duck houses were the duck houses arbitrarily converted from plastic greenhouses. This type of duck house was difficult to properly manage internal air temperature and humidity environment. Humidity environment inside duck houses is an important factor that directly affects the productivity and disease occurrence of the duck. Although the humidity environments of litters (bedding materials) affect directly the inside environment of duck houses, there are only few studies related to humidity environment of litters. In this study, evaporation rates from litters were evaluated according to air temperature, relative humidity, water contents of litters, and wind speed. The experimental chamber was made to measure evaporation rates from litters. Temperature and humidity controlled chamber was utilized during the conduct of the laboratory experiments. Using the measured data, a multi linear regression analysis was carried out to derive the calculation formula of evaporation rates from litters. In order to improve the accuracy of the multi linear regression model, the partial vapor pressure directly related to evaporation was also considered. Variance inflation factors of air temperature, relative humidity, partial vapor pressure, water contents of litters, and wind speed were calculated to identify multicollinearity problem. The Multiple $R^2$ and adjusted-$R^2$ of regression model were calculated at 0.76 and 0.71, respectively. Therefore, the regression models were developed in this study can be used to estimate evaporation rates from the litter of duck houses.

Effect of Various Forms of Floor System on Performance of Meat-type Duck and Environments of Duck House (오리사 바닥 형태가 육용오리의 생산성 및 사육환경에 미치는 영향)

  • Bang, Han-Tae;Kim, Dong-Woon;Hwangbo, Jong;Na, Jae-Cheon;Kang, Hwan-Ku;Kim, Min-Ji;Mushtaq, M.M.H.;Parvin, R.;Choi, Hee-Chul;Lee, Sang-Bae;Kang, Min;Kim, Ji-Hyuk
    • Korean Journal of Poultry Science
    • /
    • v.40 no.3
    • /
    • pp.253-262
    • /
    • 2013
  • This experiment was conducted to investigate the effects of floor type and heating system on performance, housing environment and health status of ducks reared in three types of duck house (OD : Open floor house-Direct heating system, OF : Open floor house-Floor heating system and LD : Loft type house-Direct heating system). In OF treatment, PVC pipes were installed for heating under concrete floor and covered with litter. In LD treatment, plastic mesh was installed 50 cm above the floor so that duck's droppings can pass through it. Each treatment had four replicates of 25 birds (Cherry Valley duck breed) per pen. There were no significant differences in weight gain and feed intake of ducks for 6 weeks among all treatments. However, feed conversion ratio in LD was significantly higher (p<0.05) than that in OF. No differences were found in carcass charac- teristics, with the exception of abdominal fat weight where OF were higher than the others. Concentrations of $CO_2$ and $NH_3$ gas in OD were higher than those of OF and LD at 3, 4 and 5 weeks. Moisture content in litter of OF was lower than that of OD. In contrast, the amount of dust in the air was higher in OF than in OD. The amount of fuel used for 6 weeks in LD was lower about 21% than that in OD. Some of unusual symptoms were observed in open floor house and loft type house, such as lying, spraddle legged, twisted ankle and legs, wounded sole, or etc. No components of leukocyte and erythrocyte of blood were significantly different among all treatments. The results of this experiment showed that OF and LD systems had no positive effects on performance of meat type commercial duck. However, there were some positive effects of certain house type for the improvement of environmental condition in duck house for hygienic production. In the future, more research on the effect of various facilities and systems for duck house is needed.

Analysis on Ventilation Efficiency of Standard Duck House using Computational Fluid Dynamics (전산유체역학을 이용한 표준 오리사 설계안에 대한 환기효율성 분석)

  • Yeo, Uk-Hyeon;Jo, Ye-Seul;Kwon, Kyeong-Seok;Ha, Tae-Hwan;Park, Se-Jun;Kim, Rack-Woo;Lee, Sang-Yeon;Lee, Seung-No;Lee, In-Bok;Seo, Il-Hwan
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.57 no.5
    • /
    • pp.51-60
    • /
    • 2015
  • In Korea, 69.4 % of duck farms had utilized conventional plastic greenhouses. In this facilities, there are difficulties in controlling indoor environments for raising duck. High rearing density in duct farms also made the environmental control difficult resulting in getting more stressed making their immune system weaker. Therefore, a facility is needed to having structurally enough solidity and high efficiency on the environmental control. So, new design plans of duck house have recently been conducted by National Institute of Animal Science in Korea. As a study in advance to establish standard, computational fluid dynamics (CFD) was used to estimate the aerodynamic problems according to the designs by means of overall and regional ventilation efficiencies quantitatively and qualitatively. Tracer gas decay (TGD) method was used to calculate ventilation rate according to the structural characteristics of duck houses including installation of indoor circulation fan. The results showed that natural ventilation rate was averagely 164 % higher than typically designed ventilation rate, 1 AER ($min^{-1}$). Meanwhile, mechanically ventilated duck houses made 81.2 % of summer ventilation rate requirement. Therefore, it is urgent to develop a new duck house considering more structural safety as well as higher efficiency of environmental control.

Estimation of Duck House Litter Evaporation Rate Using Machine Learning (기계학습을 활용한 오리사 바닥재 수분 발생량 분석)

  • Kim, Dain;Lee, In-bok;Yeo, Uk-hyeon;Lee, Sang-yeon;Park, Sejun;Decano, Cristina;Kim, Jun-gyu;Choi, Young-bae;Cho, Jeong-hwa;Jeong, Hyo-hyeog;Kang, Solmoe
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.63 no.6
    • /
    • pp.77-88
    • /
    • 2021
  • Duck industry had a rapid growth in recent years. Nevertheless, researches to improve duck house environment are still not sufficient enough. Moisture generation of duck house litter is an important factor because it may cause severe illness and low productivity. However, the measuring process is difficult because it could be disturbed with animal excrements and other factors. Therefore, it has to be calculated according to the environmental data around the duck house litter. To cut through all these procedures, we built several machine learning regression model forecasting moisture generation of litter by measured environment data (air temperature, relative humidity, wind velocity and water contents). 5 models (Multi Linear Regression, k-Nearest Neighbors, Support Vector Regression, Random Forest and Deep Neural Network). have been selected for regression. By using R-Square, RMSE and MAE as evaluation metrics, the best accurate model was estimated according to the variables for each machine learning model. In addition, to address the small amount of data acquired through lab experiments, bootstrapping method, a technique utilized in statistics, was used. As a result, the most accurate model selected was Random Forest, with parameters of n-estimator 200 by bootstrapping the original data nine times.

Development and Field-evaluation of Automatic Spreader for Bedding Materials in Duck Houses (오리사 바닥 깔짚자동살포장치 개발 및 실증)

  • Kwon, Kyeong-seok;Woo, Jae-seok;Noh, Je-hee;Oh, Sang-ik;Kim, Jong-bok;Kim, Jung-kon;Yang, Kayoung;Jang, Donghwa;Choi, Sungmin
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.63 no.1
    • /
    • pp.37-48
    • /
    • 2021
  • The automatic-spreader of bedding materials was developed to reduce labor cost, and to achieve successful biosecurity in duck houses. Algorithm of the device was designed to realize a concept of the automatic unmanned operation including entire processes such as loading and spreading of the bedding materials. From the field measurement, the relationship between the expected water content reduction and weight of bedding materials per unit area according to the operation condition of the devices was induced. In the case of the measurement of particulate matters during the process of spreading works, the results of using both conventional manual-spreader and automatic-spreader were exceeded the allowable limit of inhalable and respirable dust, respectively. But, workers using automatic-spreader could be free from harmful aero-condition because they did not stay inside the facility during the spreading works. In addition, from the Duck hepatitis virus PCR test, influence on pulmonary tissue of the duck was not found. It could be expected that the development of the automatic-spreader of bedding materials for duck house can contribute to the advancement of duck breeding facilities.

Laying performance of two pure-line Korean native ducks at different house types (토종오리 순종 2계통의 사육형태에 따른 산란능력)

  • Kim, Hak-Kyu;Hong, Eui-Chul;Kang, Bo-Seok;Kim, Chong-Dae;Heo, Kang-Nyeong;Choo, Hyo-Jun;HwangBo, Jong
    • Korean Journal of Agricultural Science
    • /
    • v.39 no.1
    • /
    • pp.53-60
    • /
    • 2012
  • This work was conducted to evaluate the laying performance of Korean Native Ducks (KND) Pure-Line (PL). A total of 400 female pullets were hatched from PL to keep in National Institute of Animal Science, Korea. Twenty weeks old PL female ducks were divided into 4 groups (5 replications/group, 20 head/replications). Four groups were compared in a $2{\times}2$ factorial arrangement with strain (White strains, WW; Celadon strains, CC) and house type (flat house, cage house). On first egg laying day, CC strain laid eggs earlier compared to WW strain (P<0.01), but there was no significant difference between flat and cage house. Egg weight (EW) and body weight (BW) at first egg laying day have no difference among strains and houses. BW of CC strain was higher than WW strain at the age of 30 week (P<0.01). Weekly feed intake (FI) have no difference between flat and cage house, but FI of WW strain was high compared to CC strain during 20~30 weeks. There was no significant difference on EW between CC and WW strains, but EW was low at flat house compared to cage house (P<0.05). Weekly egg productions of WW strain and flat house were lower than CC strain and cage house, respectively (P<0.01). Finally, These results can provide the information that needed to introducing new strains.

A Study on Optimizer for Building Integrated Photovoltaic System of Energy Independent House (독립형 에너지 하우스 전력시스템에서의 BIPV용 Optimizer에 대한 연구)

  • Cho, Young-Chan;Shin, Duck-Shick
    • Proceedings of the KIPE Conference
    • /
    • 2018.11a
    • /
    • pp.229-230
    • /
    • 2018
  • 본 논문은 태양광 기반의 '독립형 에너지 하우스'의 전체 전력 시스템과 태양광 외장재 모듈의 에너지를 효율적으로 최대 수급하기 위한 BIPV(Building Integrated PV)용 Optimizer의 개발에 대해 기술한다.

  • PDF

Investigations and Analyses of Duck Breeding Facilities in Jeollanam-do Province, Korea (전남지역 오리 사육시설 실태 조사 및 분석)

  • Kwon, Kyeong-seok;Yang, Kayoung;Kim, Jong-bok;Kim, Jung-kon;Jang, Donghwa;Choi, Sungmin;Lee, Sang-yeon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.63 no.1
    • /
    • pp.1-9
    • /
    • 2021
  • Number of duck and its breeding facilities have been steadily decreasing for financial and social issues in Korea. Therefore, the 'turning point' for duck industry is strongly demanded. In this study, the questionary survey was carried out to provide backgrounds for developing policy and technology for duck breeding farms. The questionary survey aimed to investigate the information of operation strategy of farm, ventilation, cooling and heating. The total number of survey respondents was 74. In case of facility type, 55.4% of respondents stated they used greenhouse type, 31.3% for winch-curtain type, and 2.7% for windowless type (mechanically ventilated facility). More than 85% of the facilities were using 'natural ventilation', it meant that these situation can restrict the not only environmental control but also the supply policy for 'smart farm' of the Government. 44.6% used the combination of the cross-ventilation method and roof-ventilation method for ventilation operation in summer season, and 31.1% followed only the cross-ventilation method. In case of winter season, 36.5% used the cross-ventilation method, and 33.3% used the combination of cross and roof-ventilation, method. For the ventilation strategy, about 86.5% depended on farmer's experience. In case of heating and cooling, 79.7% were using kerosene heater for winter season, and 43.2% were using mist-spray for summer season, respectively. More than 75% stated that cooling and heating strategies were based on farmer's experience. From the analyses of the survey results, a few proposals for developing policy and technology for duck breeding farm was suggested.

A Study on the Phenomenological Light Element in Contemporary House Interior Spaces (현대 주거 실내공간에 있어 현상학적 빛에 관한 연구)

  • Kim, Jae-Sun;Kim, Moon-Duck
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2005.10a
    • /
    • pp.151-154
    • /
    • 2005
  • These days we are more interested in the space of architecture that how the change is likely to affect and how to be realized human. Human beings are recognizable the space and the creation of the space is eventually effected through human beings being perceptible the space of architecture and the equivalence of the space. That is the light, one of phenomenological elements, has been the first visual experience at birth. This study will concentrate on the importance of the phenomenological light especially indoors and study how architectural elements influence human beings with the light as one of the basic design factors for human life. That is exactly purpose of this research paper and this paper can make our lives worth living significant with the actively various uses inside spaces through the phenomenological light as a natural light in our human beings.

  • PDF

Prevalence of Causative Allergens on Canine Atopic Dermatitis in Daejeon Area (대전지역 아토피성 피부염 이환견의 양성항원 분포)

  • Song Kun-ho;Lee Jung-youn;Liu Jianzhu;Lee Sang-eun;Park Seong-jun;Kim Duck-hwan
    • Journal of Veterinary Clinics
    • /
    • v.22 no.1
    • /
    • pp.26-30
    • /
    • 2005
  • The purpose of this study is to investigate the prevalent allergens causing canine atopic dermatitis in Daejeon area. Twenty two dogs were diagnosed with atopic dermatitis by an using intradermal skin test (IDST). Allergens used for the IDST included 33 allergen extracts from nine allergen groups: house dust mites (HDM), house dust, moulds, trees, weeds, grasses, insects/fleas, epithelia and others. The 22 purebred dogs with atopic dermatitis enrolled in this study included Shi-tzus (10/22, 45.5%), Yorkshire terriers (5/22, 22.7%), Miniature pinschers (4/22, 18.2%), Pugs (2/ 22, 9.1 %) and Cocker spaniels (1/22, 4.5%). The age of onset of atopic dermatitis ranged from 5 months to 5 years old (median: 1.79 years). The males (12/22, 54.5%) and females (10/22, 45.5%) were almost equal. The number of positive reactions to allergens recorded in each dog with atopic dermatitis was 3 (9/22, 40.9%), 2 (8/22, 36.4%), 1 (3/ 22, 13.6%) and 4 (2/22, 9.1 %), respectively. The most common positive allergen reaction was HDM (52.6%). The other positive allergen reactions recorded were from house dust (17.5%), insects/fleas (15.8%), trees (5.3%), moulds (3.5%), kapok (3.5%), silk (3.5%), epithelia (1.8%), weeds (0%) and grasses (0%), respectively. Positive reactions recorded to Dermatophagoides farinae and D. pteronyssinus were in 53.3% and 46.7%, respectively. The IDST results demonstrate that the most common causative allergens in canine atopic dermatitis in Daejeon area were HDM.