• Title/Summary/Keyword: Dual-image

Search Result 456, Processing Time 0.027 seconds

Basic Physical Principles and Clinical Applications of Computed Tomography

  • Jung, Haijo
    • Progress in Medical Physics
    • /
    • v.32 no.1
    • /
    • pp.1-17
    • /
    • 2021
  • The evolution of X-ray computed tomography (CT) has been based on the discovery of X-rays, the inception of the Radon transform, and the development of X-ray digital data acquisition systems and computer technology. Unlike conventional X-ray imaging (general radiography), CT reconstructs cross-sectional anatomical images of the internal structures according to X-ray attenuation coefficients (approximate tissue density) for almost every region in the body. This article reviews the essential physical principles and technical aspects of the CT scanner, including several notable evolutions in CT technology that resulted in the emergence of helical, multidetector, cone beam, portable, dual-energy, and phase-contrast CT, in integrated imaging modalities, such as positron-emission-tomography-CT and single-photon-emission-computed-tomography-CT, and in clinical applications, including image acquisition parameters, CT angiography, image adjustment, versatile image visualizations, volumetric/surface rendering on a computer workstation, radiation treatment planning, and target localization in radiotherapy. The understanding of CT characteristics will provide more effective and accurate patient care in the fields of diagnostics and radiotherapy, and can lead to the improvement of image quality and the optimization of exposure doses.

The Comparison of Quantitative Accuracy Between Energy Window-Based and CT-Based Scatter Correction Method in SPECT/CT Images (SPECT/CT 영상에서 에너지창 기반 산란보정과 CT 기반 산란보정 방법의 정량적 정확성 비교)

  • Kim, Ji-Hyeon;Son, Hyeon-Soo;Lee, Juyoung;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.2
    • /
    • pp.93-101
    • /
    • 2015
  • Purpose In SPECT image, scatter count is the cause of quantitative count error and image quality degradation. Thus, a wide range of scatter correction(SC) methods have been studied and this study is to evaluate the accuracy of CT based SC(CTSC) used in SPECT/CT as the comparison with existing energy window based SC(EWSC). Materials and Methods SPECT/CT images were obtained after filling air in order to acquire a reference image without the influence of scatter count inside the Triple line insert phantom setting hot rod(74.0 MBq) in the middle and each SPECT/CT image was obtained each separately after filling water instead of air in order to derive the influence of scatter count under the same conditions. In both conditions, Astonish(iterative : 4 subset : 16) reconstruction method and CT attenuation correction were commonly applied and three types of SC methods such as non-scatter correction(NSC), EWSC, CTSC were used in images filled with image. For EWSC, 9 sub-energy windows were set additionally in addition to main(=peak) energy window(140 keV, 20%) and then, images were acquired at the same time and five types of EWSC including DPW(dual photo-peak window)10%, DEW(dual energy window)20%, TEW(triple energy window)10%, TEW5.0%, TEW2.5% were used. Under the condition without fluctuations in primary count, total count was measured by drawing volume of interest (VOI) in the images of the two conditions and then, the ratio of scatter count of total counts was calculated as percent scatter fraction(%SF) and the count error with image filled with water was evaluated with percent normalized mean-square error(%NMSE) based on the image filled with air. Results Based on the image filled with air, %SF of images filled with water to which each SC method was applied is NSC 37.44, DPW 27.41, DEW 21.84, TEW10% 19.60, TEW5% 17.02, TEW2.5% 14.68, CTSC 5.57 and the most scattering counts were removed in CTSC and %NMSE is NSC 35.80, DPW 14.28, DEW 7.81, TEW10% 5.94, TEW5% 4.21, TEW2.5% 2.96, CTSC 0.35 and the error in CTSC was found to be the lowest. Conclusion In SPECT/CT images, the application of each scatter correction method used in the experiment could improve the quantitative count error caused by the influence of scatter count. In particular, CTSC showed the lowest %NMSE(=0.35) compared to existing EWSC methods, enabling relatively accurate scatter correction.

  • PDF

Design of High Speed VRAM ASIC for Image Signal Processing (영상 신호처리를 위한 고속 VRAM ASIC 설계)

  • Seol, Wook;Song, Chang-Young;Kim, Dae-Soon;Kim, Hwan-Yong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.19 no.6
    • /
    • pp.1046-1055
    • /
    • 1994
  • In this paper, to design high speed 1 line VRAM(Video RAM) suitable for image signal processing with ASIC(Application Specific IC) method, the VRAM memory core has been designed using 3-TR dual-port dynamic cell which has excellent access time and integration characteristics. High speed pipeline operation was attained by separating the first row from the subarray 1 memory core and the simultaneous I/Q operation for a selected single address was made possible by adopting data-latch scheme. Peripheral circuits were designed implementing address selector and 1/2V voltage generator. Integrated ASIC has been optimized using 1.5[ m] CMOS design rule.

  • PDF

Defect Detection of Wall Thinned Straight Pipe using Shearography and Lock-in Infrared Thermography (전단간섭계와 적외선열화상을 이용한 감육 직관의 결함검출)

  • Kim, Kyeong-Suk;Jung, Hyun-Chul;Chang, Ho-Seob;Kim, Ha-Sig;La, Sung-Won
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.11
    • /
    • pp.55-61
    • /
    • 2009
  • The wall thinning defect of nuclear power pipe is mainly occurred by the affect of the flow accelerated corrosion (FAC) of fluid. This type of defect becomes the cause of damage or destruction of in carbon steel pipes. Therefore, it is very important to measure defect which is existed not only on the welding part but also on the whole field of pipe. This study use dual-beam Shearography, which can measure the out-of-plane deformation and the in-plane deformation by using another illuminated laser beam and simple image processing technique. And this study proposes Infrared thermography, which is a two-dimensional non-contact nondestructive evaluation that can detect internal defects from the thermal distribution by the inspection of infrared light radiated from the object surface. In this paper, defect of nuclear power pipe were, measured using dual-beam shearography and infrared thermography, quantitatively evaluated by the analysis of phase map and thermal image pattern.

Spray Breakup Characteristics of LRE Injector (액체로젯엔진 인젝터의 분무 분열특성)

  • Jung, Hun;Kim, Jin-Seok;Kim, Jeong-Soo;Kim, Sung-Cho;Park, Jeong;Jang, Ki-Won
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2007.04a
    • /
    • pp.157-160
    • /
    • 2007
  • Spray characteristics of an injector employed in liquid rocket engine is investigated by Particle Image Velocimetry and Dual-mode Phase Doppler Anemometry measurements. Instantaneous plane images captured by PIV technique are examined in order to judge a pass-fail criteria of spray injection performance. DPDA technique is also applied in order to measure the velocity and diameter of spray droplets. The eternal objective of this study is to evaluate an injector performance which may be utilized for the design of brand-new ones through the clear understanding of spray characteristics.

  • PDF

EM Development of Dual Head Star Tracker for STSAT-2 (과학기술위성2호의 이중 머리 별 추적기 개발)

  • Sin, Il-Sik;Lee, Seong-Ho;Yu, Chang-Wan;Nam, Myeong-Ryong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.34 no.2
    • /
    • pp.96-100
    • /
    • 2006
  • We develop the Dual Head Star Tracker (DHST) to obtain the attitude information of science and Technology Satellite2 (STSAT-2). Because most of star sensor has only one head camera, star recognition is impossible when camera point to sun or earth. We therefore considered the DHST which can obtain star images from two spots simultaneously. That is, even though we fail a star recognition from an image obtained by one camera, it is possible to recognize stars from an image obtained by the other camera. In this paper, we introduce engineer model (EM) of the DHST and propose a star recognition and a star track algorithm.

Dual Sliding Statistics Switching Median Filter for the Removal of Low Level Random-Valued Impulse Noise

  • Suid, Mohd Helmi;Jusof, M F.M.;Ahmad, Mohd Ashraf
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.3
    • /
    • pp.1383-1391
    • /
    • 2018
  • A new nonlinear filtering algorithm for effectively denoising images corrupted by the random-valued impulse noise, called dual sliding statistics switching median (DSSSM) filter is presented in this paper. The proposed DSSSM filter is made up of two subunits; i.e. Impulse noise detection and noise filtering. Initially, the impulse noise detection stage of DSSSM algorithm begins by processing the statistics of a localized detection window in sorted order and non-sorted order, simultaneously. Next, the median of absolute difference (MAD) obtained from both sorted statistics and non-sorted statistics will be further processed in order to classify any possible noise pixels. Subsequently, the filtering stage will replace the detected noise pixels with the estimated median value of the surrounding pixels. In addition, fuzzy based local information is used in the filtering stage to help the filter preserves the edges and details. Extensive simulations results conducted on gray scale images indicate that the DSSSM filter performs significantly better than a number of well-known impulse noise filters existing in literature in terms of noise suppression and detail preservation; with as much as 30% impulse noise corruption rate. Finally, this DSSSM filter is algorithmically simple and suitable to be implemented for electronic imaging products.

3D Image Evaluation of Aneurysm in Cerebral Angiography (뇌혈관조영검사에서 동맥자루 3D 영상 평가)

  • Kyung-Wan Kim;Kyung-Min Park;In-Chul Im
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.335-341
    • /
    • 2023
  • In this study, four algorithms (Standard, Bone, Dual volume, and Stent Follow up) were applied to the image of the aneurysm in cerebral angiography to reconstruct the image in 3D, and quantitatively evaluate Noise, SNR, and CNR based on the reconstructed image to find out the optimal algorithm. As an analysis method, Image J program, which can analyze images and calculate area and pixel values, was used for images reconstructed with four algorithms. In order to obtain Noise, SNR, and CNR, the region of interest (ROI) is measured by designating the point where the abnormal artery (aneurysm) is located and the surrounding normal artery in the image are measured, and the mean value and SD value are obtained. Background noise was set to two surrounding normal artery to increase reliability. The values of SNR and CNR were calculated based on the given formula. As a result, the noise was the lowest in the stent follow-up algorithm, and the SNR and CNR were the highest. Therefore, the stent follow-up algorithm is judged to be the most appropriate algorithm. The data of this study are expected to be useful as basic data for 3D image evaluation of the vascular and aneurysm in cerebral angiography, and it is believed that appropriate algorithm changes will serve as an opportunity to further improve image quality.

Development of Hole Expansion Test for Sheet Materials Using Pattern-Recognition Technique (형태 인식 기술을 이용한 판재의 홀 확장성 평가 시스템 개발)

  • Jang, Seung Hyun;Kim, Chan Il;Yang, Seung Han;Kim, Young Suk
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.2
    • /
    • pp.161-168
    • /
    • 2013
  • Nowadays, one of the most interested area of automobile industry is the production of vehicle which has collision safety and ability to produce less amount of $CO_2$. The achievement of such a dual performance is done by choosing the materials like dual phase steel, ferrite bainite steel, etc. These steels have been used in automotive chassis and body parts, and also used to be formed by hole flanging to meet the goal of strength and design requirement. The formability of sheet material was experimented by hole expansion test and the judgement relies on human eye and his experience. This manual judgement involves many errors and large deviation. This paper develops the automatic crack recognition system which finds a crack based on CCD image to complement the problem of the current method depending on human's sense.

Bone Region Extraction by Dual Energy X-ray Absorbtion Image Decomposition (Dual Energy X-ray 흡수 영상의 분해를 통한 뼈 영역 추출)

  • Kwon, Ju-Won;Cho, Sun-Il;Ahn, Young-Bok;Ro, Yong-Man
    • Journal of Korea Multimedia Society
    • /
    • v.12 no.9
    • /
    • pp.1233-1241
    • /
    • 2009
  • Over the 50 percents of women who are older than 45 years have osteoporosis. Because people hardly recognize this disease by themselves, the researches that measure bone mineral density have been doing widely to detect osteoporosis in the early stage. The most widely used methods for bone mineral density measurement are based on the X-ray imaging. Among them, DEXA(Dual-energy X-ray Absorptiometry) imaging is one of the important methods in bone mineral density measurement. DEXA images are useful methods to increase diagnosis efficiency by reducing anatomic noise as two images obtained from two different energy levels. However, it has some problems to a calibration parameter determined by the heuristic method for bone extraction. In this paper, we propose the method to extract bone in DEXA image using calibration parameter based on anatomic attenuation coefficient. The experimental results reveal that the proposed method is effective.

  • PDF