• 제목/요약/키워드: Dual-Level

Search Result 765, Processing Time 0.035 seconds

Implant Breast Reconstruction using AlloDerm Sling; Clinical Outcomes and Effect to Capsular Formation (알로덤 슬링술을 이용한 보형물 유방재건술; 임상경과 및 피막형성에 미치는 영향)

  • Yoon, Jung Ho;Kim, Young Seok;Roh, Tai Suk
    • Archives of Plastic Surgery
    • /
    • v.36 no.6
    • /
    • pp.755-760
    • /
    • 2009
  • Purpose: Breast surgeons usually insert tissue expander or implant beneath the subpectoral - subglandular dual plane in breast reconstruction. But sometimes it happens unsatisfactory lower pole fullness, asymmetric inframammary fold and breast shape because there is implant migration due to the pectoralis major muscle contraction and gravity. To solve all the problem like these, we introduce implant breast reconstruction using AlloDerm$^{(R)}$(LifeCell Corp., Branchburg, N.J.) sling. Methods: The AlloDerm$^{(R)}$ sling was used in 13 patients and 18 breasts for implant breast reconstruction. After mastectomy, costal and lower sternal insertion of pectoralis major muscle was detached. Rehydrated AlloDerm$^{(R)}$ was sutured to the chest wall and serratus anterior fascia at the level of inframammary fold downward and to lower border of the pectoralis major muscle upward like crescent shape with tension free technique after implant insertion into the subpectoral - subAlloDerm dual pocket. Results: We make satisfactory lower pole fullness, symmetric inframammary fold and breast shape. In conclusion, patients obtain relatively natural breast shape. There was no complication except one case of capsular contracture and one case of breast cellulitis. Conclusion: Implant breast reconstruction using AlloDerm$^{(R)}$ sling makes easy to get natural breast shape through satisfactory lower pole fullness, symmetric inframammary fold and implant positioning.

Modeling and SINR Analysis of Dual Connectivity in Downlink Heterogeneous Cellular Networks

  • Wang, Xianling;Xiao, Min;Zhang, Hongyi;Song, Sida
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.11 no.11
    • /
    • pp.5301-5323
    • /
    • 2017
  • Small cell deployment offers a low-cost solution for the boosted traffic demand in heterogeneous cellular networks (HCNs). Besides improved spatial spectrum efficiency and energy efficiency, future HCNs are also featured with the trend of network architecture convergence and feasibility for flexible mobile applications. To achieve these goals, dual connectivity (DC) is playing a more and more important role to support control/user-plane splitting, which enables maintaining fixed control channel connections for reliability. In this paper, we develop a tractable framework for the downlink SINR analysis of DC assisted HCN. Based on stochastic geometry model, the data-control joint coverage probabilities under multi-frequency and single-frequency tiering are derived, which involve quick integrals and admit simple closed-forms in special cases. Monte Carlo simulations confirm the accuracy of the expressions. It is observed that the increase in mobility robustness of DC is at the price of control channel SINR degradation. This degradation severely worsens the joint coverage performance under single-frequency tiering, proving multi-frequency tiering a more feasible networking scheme to utilize the advantage of DC effectively. Moreover, the joint coverage probability can be maximized by adjusting the density ratio of small cell and macro cell eNBs under multi-frequency tiering, though changing cell association bias has little impact on the level of the maximal coverage performance.

Design of a Dual-Frequency Microstrip Patch Antenna (이중 공진형 마이크로스트립 패치 안테나 설계)

  • 김규성;김태우;최재훈
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.10 no.7
    • /
    • pp.1131-1137
    • /
    • 1999
  • In this paper, a novel design method of an apertured coupled microstrip patch antenna with the single feeding structure is proposed for dual resonance frequencies with mutually perpendicular polarizations. The characteristics of this antenna are experimentally investigated. In order to achieve this goal, a new type of square patch with double notches is used as a radiator and the crossed slot and the bended mictrostrip feeder are adopted for the dual polarizations in the aperture-coupled structure. For the application of the proposed antenna, a Ku-band Tx/Rx $2\times$ subarray antenna is designed and manufactured. Also, the applicability of the antenna as a ground terminal is examined through performance analysis. According to the measurement, the gain of the antenna is 10dBi at the center frequencies of Tx and Rx, the side lobe level is lower than -13dB, and the cross polarization lebel is below 17 dB.

  • PDF

Design and Fabrication of A Wide-Band Dual-Polarization Stacked Patch Array Antenna for Satellite SAR Applications (위성 SAR용 광대역 이중편파 적층형 패치 배열 안테나 설계 및 제작)

  • Lee, Jae-Min;Yu, Je-Woo;Chae, Heeduck;Lee, YuRi;Jung, Hwa-Young;Kim, JongPil;Park, Jongkuk
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.20 no.2
    • /
    • pp.72-78
    • /
    • 2021
  • This paper proposes a wide-band dual-polarization stacked patch array antenna for satellite SAR system applications. The array antenna was designed for loss minimization and wide-band characteristics to enhance the performance of the SAR system and optimize it for active return loss in applications to active phased arrays. The fabricated array antenna showed a performance of 19.26%/19.79% fractional bandwidth within the -10 dB reference level of the active return loss and showed loss characteristics of 0.797 dB/0.799 dB averaged within the operational frequency for both H/V-polarization cases. The pattern performance was verified by comparing the measured patterns with the calculated patterns obtained by the array factor.

How satisfied are they with husbands' sharing of domestic labor? Comparing couples from single-earner and dual-earner households (남편의 가사노동과 자녀돌봄 분담 유형별 관련요인 및 부부의 가사분담만족도: 맞벌이 부부와 비맞벌이 부부 비교)

  • Kim, Soyoung
    • Journal of Family Relations
    • /
    • v.22 no.3
    • /
    • pp.47-72
    • /
    • 2017
  • Objectives: Do husbands with working wives share domestic labor more equally than husbands with unemployed housewives? Is the husband's contribution sufficient enough to satisfy his wife? These questions have long inspired many researchers to find ways to more accurately estimate husband's domestic contributions and narrow the emotional gap following the different threshold of satisfaction within couples, but not without some limits. This study attempted to figure out an answer to the above-mentioned subject by using time diaries of Korean married couples with a preschooler as their first-born child and relying on the typology of husbands' sharing of housework and childcare, which allowed me to overcome some limitations of prior research. Method: I analyzed a total of 1,716 diaries of 858 married couples from 2014 Korea Time Use Survey with descriptive statistics, t-test, cluster analysis, and multinomial logit. Results: Analytic results showed that husbands in dual-earner households did share domestic labor more equally than husbands in single-earner households, but there were different types of husband's contribution depending on time they spent in housework and childcare. While more than half of husbands with employed wives shared more or less than ten percent of domestic labor, the rest were divided into one group of husbands who shared both housework and childcare more heavily and evenly, and another group who were mainly involved in childcare duties. It is interesting that husbands who made the least contributions to domestic labor were not the ones with the lowest level of satisfaction with their sharing of household labor, whereas their wives were deeply dissatisfied, leading to a huge emotional gap within couples. Conclusion: Identifying factors associated with the three different types allowed me to find a point of intervention to narrow the emotional gap that is likely to harm the marital relationship if left unattended to.

The Influence of Adult Attachment on Self-compassion of Teachers in Early Childhood Education and Care: Examining the Parallel Dual Mediating Effects of Positive and Negative Affects (영유아교사의 성인애착이 자기자비에 미치는 영향: 정서의 병렬이중매개효과)

  • An, Hye Ryung;Cha, Jin-Young
    • Korean Journal of Childcare and Education
    • /
    • v.16 no.6
    • /
    • pp.203-232
    • /
    • 2020
  • Objective: The purpose of this study was to examine the parallel dual mediating effects of positive and negative affects in the relationship between adult attachment and self-compassion of teachers in the early childhood education and care centers. Methods: Two hundred and six teachers participated in the survey who were recruited from kindergarten and child care centers in Seoul and five provinces in South Korea. The data were analyzed by means of frequency, percentages, Cronbach's reliability coefficient and Pearson's correlation using SPSS 25.0 and model 4 provided in The PROCESS macro for SPSS 3.4 version. Results: First, the teachers' degrees of anxiety and avoidance in their adult attachment were below the median scores. Those of positive and negative affects, and their self-compassion were close to the median scores. Second, there were parallel dual mediation effects of positive and negative affects between anxious attachment and self-compassion of teachers. Meanwhile, only positive affect had a mediating effect in the path of teachers' avoidant attachment and self-compassion. Conclusion/Implications: This study confirmed that it is important to raise positive affect by lowering each level of anxiety and avoidance in their attachment for teachers in order to improve their self-compassion. It implied the need to provide support for attachment stability enhancement and to pay attention to improve their self-compassion.

Deriving the Effective Atomic Number with a Dual-Energy Image Set Acquired by the Big Bore CT Simulator

  • Jung, Seongmoon;Kim, Bitbyeol;Kim, Jung-in;Park, Jong Min;Choi, Chang Heon
    • Journal of Radiation Protection and Research
    • /
    • v.45 no.4
    • /
    • pp.171-177
    • /
    • 2020
  • Background: This study aims to determine the effective atomic number (Zeff) from dual-energy image sets obtained using a conventional computed tomography (CT) simulator. The estimated Zeff can be used for deriving the stopping power and material decomposition of CT images, thereby improving dose calculations in radiation therapy. Materials and Methods: An electron-density phantom was scanned using Philips Brilliance CT Big Bore at 80 and 140 kVp. The estimated Zeff values were compared with those obtained using the calibration phantom by applying the Rutherford, Schneider, and Joshi methods. The fitting parameters were optimized using the nonlinear least squares regression algorithm. The fitting curve and mass attenuation data were obtained from the National Institute of Standards and Technology. The fitting parameters obtained from stopping power and material decomposition of CT images, were validated by estimating the residual errors between the reference and calculated Zeff values. Next, the calculation accuracy of Zeff was evaluated by comparing the calculated values with the reference Zeff values of insert plugs. The exposure levels of patients under additional CT scanning at 80, 120, and 140 kVp were evaluated by measuring the weighted CT dose index (CTDIw). Results and Discussion: The residual errors of the fitting parameters were lower than 2%. The best and worst Zeff values were obtained using the Schneider and Joshi methods, respectively. The maximum differences between the reference and calculated values were 11.3% (for lung during inhalation), 4.7% (for adipose tissue), and 9.8% (for lung during inhalation) when applying the Rutherford, Schneider, and Joshi methods, respectively. Under dual-energy scanning (80 and 140 kVp), the patient exposure level was approximately twice that in general single-energy scanning (120 kVp). Conclusion: Zeff was calculated from two image sets scanned by conventional single-energy CT simulator. The results obtained using three different methods were compared. The Zeff calculation based on single-energy exhibited appropriate feasibility.

Transmission Performance Comparison of Direction Detection-Based 100-Gb/s Modulation Formats for Metro Area Optical Networks

  • Chung, Hwan Seok;Chang, Sun Hyok;Lee, Jonghyun;Kim, Kwangjoon
    • ETRI Journal
    • /
    • v.34 no.6
    • /
    • pp.800-806
    • /
    • 2012
  • Transmission performances of direct detection-based 100-Gb/s modulation formats are investigated and compared for metro area optical networks. The effects of optical signal-to-noise ratio sensitivity, chromatic dispersion, cross-channel nonlinearity, and transmission distance on the performance of differential 8-ary phase-shift keying (D8PSK), differential phase-shift keying plus three-level amplitude-shift keying (DPSK+3ASK), and dual-carrier differential quaternary phase-shift keying (DC-DQPSK) are evaluated. The performance of coherent dual-polarization quadrature phase-shift keying (DP-QPSK) with block phase estimation and coherent DP-QPSK with digital differential detection are also presented for reference. According to our analysis, all three direct detection modulation formats could transmit a 100-Gb/s signal over several hundred kilometers of a single-mode fiber link. The results also show that DC-DQPSK outperforms D8PSK and DPSK+3ASK, and the performance of DC-DQPSK is comparable to that of coherent DP-QPSK with digital differential detection. The maximum transmission distance of DC-DQPSK is over 1,000 km, which is enough distance for metro applications.

A Design Method of Transformer Turns Ratio with the Loss Components Analysis of an Isolated Bidirectional DC-DC Converter (절연형 양방향 DC-DC 컨버터의 손실 성분 분석을 통한 변압기 권선비 설계 방법)

  • Jung, Jae-Hun;Kim, Hak-Soo;Nho, Eui-Cheol;Kim, Heung-Geun;Chun, Tae-Won
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.5
    • /
    • pp.434-441
    • /
    • 2016
  • This paper deals with transformer turns ratio design with the consideration of loss minimization in isolated bidirectional DC-DC converter. Generally, the rms value of current, magnitude of current at switching instance, and duty ratio of a converter vary according to the turns ratio of an isolation transformer in the converter under the same voltages and output power level. Therefore, the transformer turns ratio has an effect on the total loss in a converter. The switching and conduction losses of IGBTs and MOSFETs consisting of dual-active bridge converter are analyzed, and iron and copper losses in an isolation transformer and inductor are calculated. Total losses are calculated and measured in cases of four different transformer turns ratios through simulation and experiment with 3-kW converter, and an optimum turns ratio that provides minimum losses is found. The usefulness of the proposed transformer turns ratio design approach is verified through simulation and experimental results.

Optimal SOC Reference Based Active Cell Balancing on a Common Energy Bus of Battery

  • Bae, SunHo;Park, Jung-Wook;Lee, Soo Hyoung
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.29-38
    • /
    • 2017
  • This paper presents a study on the state-of-charge (SOC) reference based active cell balancing in real-time. The optimal references of SOC are determined by using the proposed active cell balancing system with the bidirectional DC/DC converters via the dual active bridge (DAB) type. Then, the energies between cells can be balanced by the power flow control of DAB based bidirectional DC/DC converters. That is, it provides the effective management of battery by transferring energy from the strong cell to the weak one until the cell voltages are equalized to the same level and therefore improving the additional charging capacity of battery. In particular, the cell aging of battery and power loss caused from energy transfer are considered. The performances of proposed active cell balancing system are evaluated by an electromagnetic transient program (EMTP) simulation. Then, the experimental prototype is implemented in hardware to verify the usefulness of proposed system.