• Title/Summary/Keyword: Dual source

Search Result 386, Processing Time 0.028 seconds

ACCELEROMETER SELECTION CONSIDERATIONS Charge and Integral Electronic Piezo Electric

  • Lally, Jim
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.1047-1051
    • /
    • 2004
  • Charge amplifier systems benefit from the very wide dynamic range of PE accelerometers by offering flexibility in adjusting the electrical output characteristics such as sensitivity and range. They are well suited for operation at high temperatures. Modern charge systems feature improved low noise operation, simplified digital controls, and dual mode operation for operation with charge or IEPE voltage mode sensors. high impedance circuitry is not well suited for operation in adverse field or factory environments. The resolution of a PE accelerometer may not be specified or known since noise is a system consideration determined by cable length and amplifier gain. IEPE accelerometrs operate from a constant current power source, provide a high-voltage, low-impedance, fixed mV/g output. They operate through long, ordinary, coaxial cable in adverse environments without degradation of signal quality. They have limited high temperature range. IEPE sensors are simple to operate. Both resolution and operating range are defined specifications. Cost perchannel is lower compared to PE systems since low-noise cable and charge amplifiers are not required.

  • PDF

Diagnosis of Graft Infection Using FDG PET-CT

  • Shim, Hun-Bo;Sung, Ki-Ick;Kim, Wook-Sung;Lee, Young-Tak;Park, Pyo-Won;Jeong, Dong-Seop
    • Journal of Chest Surgery
    • /
    • v.45 no.3
    • /
    • pp.189-191
    • /
    • 2012
  • Graft infections after aortic replacement are a rare, but severe complication. Because surgical removal of the infection source is essential, an accurate diagnosis is required to prevent unnecessary treatment. Both of the patients described herein were diagnosed with graft infections using dual-modality positron emission tomography-computed tomography; one patient was a false-positive, and the other was confirmed with an infection.

The Fashion of Korean National Flag at World Cup 2002 (2002년(年) 월드컵에 나타난 태극기(太極旗) 패션에 관(關)한 연구(硏究))

  • Kim, Hee-Jin;Kan, Ho-Sup
    • Journal of Fashion Business
    • /
    • v.6 no.5
    • /
    • pp.12-26
    • /
    • 2002
  • The purpose of this study is considering about the fashion of Korean National Flag in the point of view of sociology and philosophy. The contents are the philosophy of the Korean National Flag-'Taegk', the Great Absolute in Korean philosophy, and the historical fashion trend of The Korean National Flag. The results of characteristics of The Korean National Flag are summarized as following; 1. The Korean National Flag contains 'Taegk' philosophy, the source of the dual principle 'Yn' and 'Yang'. 2. The design of 'Taegk' has been showed in Korean society traditionally. 3. The fashion of Korean National Flag dramatically is changed after Korea/Japan World cup 2002. 4. The Korean National Flag is the strong symbol of Korean society, affirmatively, same as the American National Flag.

듀얼 Freuqency가 인가된 자화된 ICP에서, RF 바이어스 파워가 플라즈마의 밀도에 미치는 영향

  • Kim, Hyeok;Lee, U-Hyeon;Park, Wan-Jae;Hwang, Gi-Ung
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.486-486
    • /
    • 2012
  • 반도체 식각 공정에서 이온의 플럭스와 충돌 에너지를 각각 조절하고자 Dual frequency RF source가 사용된다. 듀얼 freuqnecy RF가 인가된 Capacitively coupled plasma (CCP) 의 경우, 기판에 걸린 Low freuqency (LF) RF 소스에 의하여 이온의 에너지를 조절하고, High frequency (HF) 소스를 조절하여 이온의 플럭스를 조절하는 것이 일반적이다. 그러나 LF의 세기가 증가함에 따라서, 플라즈마의 밀도가 오히려 감소하는 문제점이 있었다. 이 경우, 약한 자장을 플라즈마에 걸어줌으로써 밀도가 감소되는 문제를 해결할 수 있다고 알려져 왔다. Inductively coupled plasma (ICP) 에서는 HF를 안테나에 가하여 이온의 플럭스를 조절하고, LF를 기판에 가하여 이온의 충돌 에너지를 조절하는 것이 일반적인데, 위와 동일한 문제가 이 경우에도 발생하는 것을 확인 하였다. CCP와 마찬가지로, 바이어스에 걸린 파워의 세기가 증가함에 따라서 플라즈마의 밀도가 감소하고 전자의 온도가 증가하는 현상을 확인하였다. 또한 이때에도, 약한 자장을 걸어줌으로써 플라즈마의 밀도가 감소하지 않고 유지될 수 있으며, 전자의 온도 또한 유지될 수 있음을 발견하였다.

  • PDF

Pilot observations of VLBI fringe survey at 43 GHz using VERA

  • Oh, Jung-Hwan;Lee, Sang-Sung;Honma, Mareki;Kovalev, Y.Y.;Petrov, Leonid;Sohn, Bong-Won
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.2
    • /
    • pp.60.1-60.1
    • /
    • 2011
  • We present the preliminary results of the pilot observations for the fringe survey at 43 GHz with the VLBI Exploration of Radio Astrometry (VERA). The main goals of the fringe survey are to establish a full list of phase calibrators for the VERA dual-beam astrometric observations, and for the KVN multi-frequency phase referencing observations. We performed two 24 hours experiments as a pilot observation to test the feasibility of the fringe survey. Each source from a list of 220 sources has been observed in one scan for 2 minutes. 67 sources were detected with the SNR threshold of 3.5. The correlated flux densities of the detected sources are presented in four ranges of projected baseline lengths.

  • PDF

Diffraction of Electromagnetic Waves by a Dielectric Wedge, Part III: Correction by Neumann-Expanded Source (쇄기형 유전체에 의한 전자파의 회절, III부: Neumann 전개된 전원에 의한 수정)

  • 김세윤;라정웅;신상영
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.25 no.9
    • /
    • pp.1027-1038
    • /
    • 1988
  • This paper, the last part of these three companion papers treated the electromagnetic diffraction by a dielectric wedge, presents the correction to the physical optics approcomation by the sheet currents of the Neumann expansion. Those expansion coefficients obtained by solving dual series equation amenable to simple numerical calculation may provide the asymprotically corrected solution. The validity of this result, satisfying both the edge condition near the tip of the dielectric wedge and the boundary condition along dielectric interfaces, is assured by approach of the corrected diffraction pattern to that of a perfectly conducting wedge for large permittivity of dielectric wedge.

  • PDF

A Study on New Algorithm for K Shortest Paths Problem (복수최단경로의 새로운 해법 연구)

  • Chang ByungMan
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 2002.05a
    • /
    • pp.8-14
    • /
    • 2002
  • This article presents a new algorithm for the K Shortest Paths Problem which develops initial K shortest paths, and repeal to expose hidden shortest paths with dual approach and to replace the longest path in the present K paths. The initial solution which comprises K shortest paths among shortest paths to traverse each arc is made from bidirectional Dijkstra algorithm. When a crossing node that have two or more inward arcs is found at least three time by turns in this K shortest paths, one inward arc of this crossing node, which has minimum detouring distance, is chosen, and a new path is exposed with joining a detouring subpath from source to this inward arc and a spur of a feasible path from this crossing node to sink. This algorithm, requires worst case time complexity of $O(Kn^2),\;and\;O(n^2)$ in the case $K{\leq}3$.

  • PDF

Analysis of Satellite Network supporting Dynamic Bandwidth Allocation (동적 대역폭 할당을 지원하는 위성망 분석)

  • Pae, Tae-Ung;Lee, Jong-Kyu
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2000.10b
    • /
    • pp.1091-1094
    • /
    • 2000
  • 본 논문은 위성 망에서 데이터 Traffic을 다루는 System을 제안하고, 성능을 분석한다. Traffic Source는 듀얼 리키 버켓(DLB : Dual Leaky Bucket)에 의해 일정하게 조정된 Traffic을 사용하며, 이러한 Traffic을 이용하여 제안한 시스템의 성능을 수학적으로 분석하고, 이를 시뮬레이션을 통해 검증한다. 제안한 시스템은 각 연결의 용량 변경 요구를 동적으로 허락하기 때문에 그 연결 자체의 초기화 설정 및 연결을 해제하는 다른 별도의 알고리즘이 필요 없어 기존의 회선 교환 시스템보다 효율적이다. 또한, 서비스 질을 결정적으로 보장함으로 망의 유연성 및 신뢰성을 높인다. 이러한 분석 결과는 앞으로 회선 교환 System에서 Protocol의 설계 및 구현 시 유용하게 사용될 수 있을 것으로 생각된다.

  • PDF

Effects of Growth Substrates on Cometabolic Biodegradation of Trichloroethylene by Burkholderia cepacia G4 (Burkholderia cepacia G4에 의한 트리클로로에틸렌의 공동대사적 분해에 미치는 성장기질의 영향)

  • 예병대;박성훈;이은열
    • KSBB Journal
    • /
    • v.15 no.5
    • /
    • pp.474-481
    • /
    • 2000
  • The effects of growth substrates such as toluene and phenol on cometabolic biodegradation of trichloroethylene (TCE) by Burkholderia cepacia G4 were investigated. The dual effects of primary substrate on TCE biodegradation, stimulatory effects of toluene and phenol at low concentrations (0.5∼2 ppm & 0.1∼0.5 ppm, respectively) and a competitive inhibition at high concentration, were observed in batch experiments. These stimulatory effects of toluene and phenol were found to be due to the increments in the amount of reducing power like NADH which could be generated during the assimilation of toluene and phenol as the carbon and energy source. The efficiency of TCE biodegradation in trickling biofilm reactor (TBR) could be also enhanced up to the TCE removal efficiency of 58.1% by the supply of appropriate amounts of phenol (0.94∼4.7 ppm).

  • PDF

Desing and fabrication of GaAs prescalar IC for frequency synthesizers (주파수 합성기용 GaAs prescalar IC 설계 및 제작)

  • 윤경식;이운진
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.21 no.4
    • /
    • pp.1059-1067
    • /
    • 1996
  • A 128/129 dual-modulus prescalar IC is designed for application to frequency synthesizers in high frequency communication systems. The FET logic used in this design is SCFL(Source Coupled FET Logic), employing depletion-mode 1.mu.m gate length GaAs MESFETs with the threshold voltage of -1.5V. This circuit consists of 8 flip-flops, 3 OR gates, 2 NOR gates, a modulus control buffer and I/O buffers, which are integrated with about 440 GaAs MESFETs on dimensions of 1.8mm. For $V_{DD}$ and $V_{SS}$ power supply voltages 5V and -3.3V Commonly used in TTL and ECL circuits are determined, respectively. The simulation results taking into account the threshold voltage variation of .+-.0.2V and the power supply variation of .+-.1V demonstrate that the designed prescalar can operate up to 2GHz. This prescalar is fabricated using the ETRI MMIC foundary process and the measured maximum operating frquency is 621MHz.

  • PDF