• Title/Summary/Keyword: Dual rate

Search Result 823, Processing Time 0.027 seconds

Performance of Heat Pump Water Heater with Dual Condenser (2단 응축 히트펌프 온수시스템의 사이클 해석 및 성능분석)

  • Ryou, Y.S.;Kim, Y.J.;Kang, G.C.;Paek, Y.;Yun, J.H.;Kang, Y.G.;Lee, H.M.
    • Journal of Biosystems Engineering
    • /
    • v.31 no.5 s.118
    • /
    • pp.423-429
    • /
    • 2006
  • The heat pump water heater developed in this research consisted of one evaporator, one compressor, 1st condenser, 2nd condenser, one expansion valve, one water tank, one recirculation circuit and etc. The performance of heat pump water heater was tested and analyzed. The quantities of output water changed linearly from 2380 to $660{\ell}/h$, and the output water temperature changed curvedly from 29.9 to $44.5^{\circ}C$ when the opening rate of recirculation valve changed from 0 to 100%. The COP of heat pump water heater increased from 3.0 to 3.8 when the quantities of output water changed from 660 to $2380{\ell}/h$. When the temperature distributions of water tank were measured during 50 minutes after turning on the heat pump, the temperature stratification by the level appeared apparently. When the inlet water temperature changed from 30 to$50^{\circ}C$, the output energy of heat pump hardly changed. The surface area of double pipe heat exchanger changed from 0.429 to $6.254m^2$ when the compressor capacity increased from 1.0 to 50.0 PS.

A Study on the Flow Path Position Design of Waviness Friction Pad for Drag Torque Reduction in Wet Type DCT (파형 습식클러치의 드래그 토크 저감을 위한 파형내 유로 위치 설정 설계 연구)

  • Cho, Junghee;Han, Juneyeol;Kim, Woojung;Jang, Siyoul
    • Tribology and Lubricants
    • /
    • v.33 no.1
    • /
    • pp.1-8
    • /
    • 2017
  • Drag torque reduction in a wet clutch pack is a key aspect of the design process of the dual clutch transmission (DCT) system. In order to reduce the drag torque caused by lubricant shear resistance, recently developed wet clutch pack systems of DCT, as well as automatic transmission and other four-wheel drive (4WD) couplings, frequently utilize wavy wet clutch pads. Therefore, wavy shape of friction pad are made on the groove patterns like waffle pattern for the reduction of drag torque. Additionally, the groove patterns are designed with larger channels at several locations on the friction pad to facilitate faster outflow of lubricant. However, channel performance is a function of the waviness of the friction pad at the location of the particular channel. This is because the discharge sectional area varies according to the waviness amplitude at the location of the particular channel. The higher location of the additional channel on the friction pad results in a larger cross-sectional area, which allows for a larger flow discharge rate. This results in reduction of the drag torque caused by the shear resistance of DCTF, because of marginal volume fraction of fluid (VOF) in the space between the friction pad and separator. This study computes the VOF in the space between the friction pad and separator, the hydrodynamic pressure developed, and the shear resistance of friction torque, by using CFD software (FLUENT). In addition, the study investigates the dependence of these parameters on the location and waviness amplitude of the channel pattern on the friction pad. The paper presents design guidelines on the proper location of high waviness amplitude on wavy friction pads.

Microstructure and Tensile Strength Property of Arc Brazed DP steel using Cu-Sn Insert Metal (Cu-Sn 삽입금속을 이용한 DP강의 아크 브레이징 접합부의 미세조직과 인장특성)

  • Cho, Wook-Je;Cho, Young-Ho;Yun, Jung-Gil;Kang, Chung-Yun
    • Journal of Welding and Joining
    • /
    • v.31 no.1
    • /
    • pp.58-64
    • /
    • 2013
  • The following results were obtained, microstructures and tensile properties in arc brazed joints of DP(dual phase) steel using Cu-5.3wt%Sn insert metal was investigated as function of brazing current. 1) The Fusion Zone was composed of ${\alpha}Fe+{\gamma}Cu$ and Cu23Sn2. The reason for the formation of these solid solutions. Despite, Fe & Cu were impossible to solid solution at room temperature. It's melting & reaction to something of insert metal & Base Metal (DP Steel) by Arc. Brazing Process has faster cooling rate then Cast Process, Supersaturated solid solution at room temperature. 2) The increase Hardness of Fusion Zone was directly proportional to the rise of welding current. Because, ${\alpha}Fe+{\gamma}Cu$ phase (higher hardness than the Cu23Sn2.(104.1Hv < 271.9Hv)) Volume fraction was Growth, due to increasing the amount of base metal melting by High current. 3) The results of tensile shear test by Brazing, All specimens happen to fracture in Fusion Zone. On the other hand, when Brazing Current increasing tend to rise tensile load. but it was very small, about 26-30% of the base metal. 4) The result of fracture analysis, The crack initiate at Triple Point for meet to Upper B.M/Under B.M/Fusion Zone. This Crack propagated to Fusion zone. So ruptured by tensile strength. The Reason to in the fusion zone fracture, Fusion zone by Brazing of hardness (strength) was very lower then the base metal (DP steel). In addition the Fusion Zone's thickness in triple point was thin than the base metal's thickness in triple point.

Numerical Study on the Inlet Head Configuration of Multi-Phase Separator for Modularization (다상유동 분리기 모듈화를 위한 유입구 형상 설계에 관한 수치해석적 연구)

  • Hong, Chang-Ki;Kim, Youn-Jea
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.9
    • /
    • pp.571-577
    • /
    • 2017
  • In this numerical study, the separation efficiency of three-phase separator in an oil-sand plant was studied with various inlet head configurations. The free water knockout (FWKO) vessel was designed with a flow rate of $15.89m^3/day$ (100 bbl/day) and the SOR(stream-to-oil ratio)=3.5 was derived using Stokes' law. For modularization, optimization of the design of the inlet head configuration was performed with parallel-connected dual FWKO vessels. The feed condition of bitumen emulsion was API=17, $T_{in}=150^{\circ}C$ and $P_{in}=50bar$. A mean residence time was determined the time when 95% of the oil and water in FWKO vessel was separated. The combination between the volume of fluid (VOF) and the discrete phase model (DPM) was used to simulate the phase separation phenomenon in a multi-phase separator. Furthermore, in order to calculate multi-phase flow the pseudo-transient method was adopted.

Decrease of Global Warming Effect During Dry Etching of Silicon Nitride Layer Using C3F6O/O2 Chemistries

  • Kim, Il-Jin;Moon, Hock-Key;Lee, Jung-Hun;Jung, Jae-Wook;Cho, Sang-Hyun;Lee, Nae-Eung
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.459-459
    • /
    • 2012
  • Recently, the discharge of global warming gases in dry etching process of TFT-LCD display industry is a serious issue because perfluorocarbon compound (PFC) gas causes global warming effects. PFCs including CF4, C2F6, C3F8, CHF3, NF3 and SF6 are widely used as etching and cleaning gases. In particular, the SF6 gas is chemically stable compounds. However, these gases have large global warming potential (GWP100 = 24,900) and lifetime (3,200). In this work, we chose C3F6O gas which has a very low GWP (GWP100 = <100) and lifetime (< 1) as a replacement gas. This study investigated the effects of the gas flow ratio of C3F6O/O2 and process pressure in dual-frequency capacitively coupled plasma (CCP) etcher on global warming effects. Also, we compared global warming effects of C3F6O gas with those of SF6 gas during dry etching of a patterned positive type photo-resist/silicon nitride/glass substrate. The etch rate measurements and emission of by-products were analyzed by scanning electron Microscopy (SEM; HITACI, S-3500H) and Fourier transform infrared spectroscopy (FT-IR; MIDAC, I2000), respectively. Calculation of MMTCE (million metric ton carbon equivalents) based on the emitted by-products were performed during etching by controlling various process parameters. The evaluation procedure and results will be discussed in detail.

  • PDF

Contents Analysis of Figure Skating Costume Design (피겨스케이팅 의상디자인의 내용분석연구)

  • Jang, A-Reum;Lee, Myoung-Hee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.35 no.2
    • /
    • pp.146-155
    • /
    • 2011
  • This study examines the design characteristics of figure skating costumes by a content analysis of their design elements. The content analysis method for the study was used based on 185 photos of female figure skaters. A total of 218 coding units in 15 categories were used. In the category of color, unicolor costumes were the mainstay and represented 48.11% of the total costumes. Black costumes showed the highest rate (13.51%), followed by red (7.57%) and blue (7.03%). In the dual-color costumes, combinations of red and black and white and black, represented 4.32% of all costumes. A camisole was the most popular type of neckline (20.54%). Stand collars with neck decorations were found in 5.95% of the costumes. In addition, 98.2% of all figure skating costumes had decorations (crystal beads 21.86% were the most frequently used decoration type), 65.41% exposed all the shoulders and arms, 70.81% of the costumes did not have sleeves, 5.41% of the costumes had arm decorations, and 3.78% had wrist decorations. In the analysis of the hem of skirts, 32.40% had a curved line, 30.73% had a straight line, and 15.08% had an unrecognizable form. In general, the figure skating costumes have stand collars with neck decorations, arm and wrist decorations, and irregular skirt hems that are not found in everyday dresses. To emphasize and intensify a theatrical effect, the costumes were fabulously decorated with spangles, crystal beads, feathers, and lace; black, red, and blue were frequently used. The skirts had frills, fringe, flared lines, and beads on them to reflect the stage lights and emphasize movements.

An Experimental Study on the Fire Risk Assessment & Calculation Breakthrough Time through Permeation Test of Chemical Protective Clothing (화학보호복의 화재위험성 및 화학적 투과시험을 통한 파과시간산정에 관한 실험적 연구)

  • Ko, Jae-Sun;Park, Pyoung-Kyu
    • Fire Science and Engineering
    • /
    • v.24 no.2
    • /
    • pp.21-30
    • /
    • 2010
  • We have test chemical resistance and flame retardant properties of chemical protective clothing Fabrics by the ASTM and ISO standard methods. The flame retardant test results show that polyethylene is poor in flame resistance but fluoroelastomer add to decabrom is excellent in flame resistance. Especially, nowadays heat protective clothing for firefighters, which is aluminized film layers laminated to aramid fabric, show the excellent flame resistance. However, the chemical resistance test results show that aluminium is high corrosive in 4M NaOH solution alone. The problem of corrosion can be overcome by employing multiple barrier film. Also, based on the result of flame retardant test, duel skin of polymer barrier film add to aluminum film and single skin of fluorinated rubber with flame retardant materials seems to be fit for the chemical protective clothing. Also the thermal protection and heat transfer test results show that TPP and HTI is increased assured that the continued study on fire risk assessment & chemical resistance of chemical protective clothing fabrics will contribute to the upgrade the performances of chemical protective clothing fabrics.

An Experiment on the Culture of Laver, Porphgra tenera, on the 'Sae-ol-bal' (triple-knotted blind) Laver Bed (세올발에 의한 김 양식시험)

  • KOH Nam-Pyo;PARK Chong Hong
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.1 no.1
    • /
    • pp.19-30
    • /
    • 1968
  • An experiment on the culture of laver, Porphyra tenera, was carried out from September 26, 1965 to February 12, 1966 at a laver farm on the coast of Gae-do, Hwacheong-myeon, Yeocheon-gun, Jeonranam-do, using 'Sae-ol-bal' (triple-knotted blind) laver bed, resulting in the following data: 1. 'Sae-ol-bal' laver, bed was less destroyed compared to ordinary (dual knotted blind) laver bed, the destruction rate being $9.8\%$ in 'Sae-ol-bal' laver bed, while $35.3\%$ in ordinary laver bed (Table 5). 2. The quantity of laver yield is the greatest on the edge-part, the next on the basal part, and the smallest on the middle part of the 'Sae-ol-bal' laver bed (Table 6, Figs. $7\~8$). 3. The ordinary laver bed may yield better harvest on the calm farm but 'Sae-ol-bal' laver bed yields better harvest at a farm where the destruction of bed is remarkable by wind and wave action.

  • PDF

Adaptive Dual-Hop Transmission Based On Hierarchical Modulation in UWB System (초광대역 시스템의 계층변조 기반 적응적 듀얼 홉 전송 기법)

  • Kim, Dae-Hwan;Song, Hyoung-Kyu;Cho, We-Duke
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.7C
    • /
    • pp.443-450
    • /
    • 2011
  • Recently, various transmission techniques for communication and broadcasting systems have been developed to meet the dramatically increasing requirement of consumers. Because UWB (Ultra-Wideband) is a wireless communication technique that supports high data rate with low power, it can satisfy the requirement and can be applied to various wireless communication services. The multi-band orthogonal frequency division multiplexing (MB-OFDM) system, one of UWB system, is the wireless communication system that satisfies the transmission characteristic for UWB and so it can be used for various wireless communication services. In this paper, we propose a scheme that uses hierarchical modulation which is applied in digital video broadcasting system at the source and adaptive modulation based on the channel quality at the relays. The simulation results have shown that the proposed scheme has both the advantages of the increased throughput by 33% and similar BER performance to conventional scheme.

A Study on the Correlation between of Bone Mineral Density and Cold Hypersensitivity of Hands (골밀도와 수냉증과의 상관성 연구)

  • Lee, Dong-Nyung;Lee, Jeong-Im;Go, Ho-Yeon;Kim, Hyung-Jun
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.28 no.4
    • /
    • pp.11-20
    • /
    • 2015
  • Objectives The purpose of this study was to examine the relationship between cold hypersensitivity and bone mineral density. Methods 28 outpatients who visited OO University Oriental Hospital from July 11th, 2013 to August 28th, 2013 were analyzed. Patients were subjected to thermometer, and those with thermal difference greater than 0.3 ℃ between upper arm and palm and also with more than VAS 4 of cold hypersensitivity were diagnosed with cold sensitivity. Lumba spine (L2-4) and heel bone measurement were obtained on dual energy X-ray absorptiometry (DEXA) and Quantitative Computed Tomography (QCT). Results 1. There was statistically significant correlation between T-score of DEXA and body weight (0.522), BMI (0.643), OSTA (Osteoporosis elf-assesment Tool for Asians, 0.579), BMI, T-score and Z-score of QCT. OSTA and T-score of QCT (0.521) also had statistically significance. 2. There was no statistically significant correlation between body fat, abdominal obesity rate, degree of cold hypersensitivity, upper arm and palm's temperature difference, palm temperature, height and Z-score, T-score of QCT or T-sore of DEXA. Conclusions Bone mineral density was lower in women who had cold hypersensitivity of hand and feet. But there was no statistically significant correlation between bone mineral density and degree of cold hypersensitivity, upper arm and palm’s temperature difference.