• Title/Summary/Keyword: Dual energy

Search Result 1,040, Processing Time 0.028 seconds

Osteoporotic Condition in Postmenopausal Women with Periodontitis (폐경후 여성의 치주질환 심도에 따른 골다공증 소견)

  • Kim, Kang-Moon;Kim, Young-Jun;Chung, Hyun-Ju
    • Journal of Periodontal and Implant Science
    • /
    • v.32 no.1
    • /
    • pp.225-234
    • /
    • 2002
  • The purpose of this study was to evaluate the relationship between the osteoporotic condition and periodontal condition in postmenopausal women with periodontitis. Forty three female postmenopausal patients with no systemic disease were grouped into 3 groups by their periodontal conditions; 12 mild periodontitis, 11 moderate periodontitis and 20 advanced periodontitis. From each patient, age of menopause was taken, alkaline phosphatase(ALP) and osteocalcin (OC) in blood and deoxypyridinoline (DPD) in urine were measured. Bone mineral density (BMD) of lumbar spine (L2-L4) was measured by dual energy X-ray absorptiometry. Periodontal and osteoporotic parameters were compared among the groups and correlation coefficient between them was evaluated. The blood ALP and OC levels were similar among the groups with different periodontal condition, whereas the urine DPD level and BMD were significantly lower in advanced periodontitis group than the other groups(p<0.01). Probing depth was negatively related with BMD (r=-0.5, p<0.01) and positively related with patient age and the duration of menopause (r= 0.32 and 0.35 respectively, p<0.05). Clinical attachment loss was negatively related with BMD (r=-0.66, p<0.01), and positively related with urine DPD (r= 0.37, p<0.05). These results showed that postmenopausal women with advanced periodontitis had significantly decreased bone mineral density and suggests that decreased bone mineral density in postmenopausal women could be associated with periodontal tissue breakdown.

Angiogenic factor-enriched platelet-rich plasma enhances in vivo bone formation around alloplastic graft material

  • Kim, Eun-Seok;Kim, Jae-Jin;Park, Eun-Jin
    • The Journal of Advanced Prosthodontics
    • /
    • v.2 no.1
    • /
    • pp.7-13
    • /
    • 2010
  • Although most researchers agree that platelet-rich plasma (PRP) is a good source of autogenous growth factors, its effect on bone regeneration is still controversial. The purpose of this study was to evaluate whether increasing angiogenic factors in the human PRP to enhance new bone formation through rapid angiogenesis. MATERIAL AND METHODS. In vitro, the human platelets were activated with application of shear stress, $20\;{\mu}g/ml$ collagen, 2 mM $CaCl_2$ and 10U thrombin/$1\;{\times}\;10^9$ platelets. Level of vascular endothelial growth factor (VEGF) and platelet microparticle (PMP) in the activated platelets were checked. In the animal study, human angiogenic factors-enriched PRP was tested in 28 athymic rat's cranial critical bone defects with $\beta$-TCP. Angiogenesis and osteogenesis were evaluated by laser Doppler perfusion imaging, histology, dual energy X-ray densinometry, and micro-computed tomography. RESULTS. In vitro, this human angiogenic factors-enriched PRP resulted in better cellular proliferation and osteogenic differentiation. In vivo, increasing angiogenic potential of the PRP showed significantly higher blood perfusion around the defect and enhanced new bone formation around acellular bone graft material. CONCLUSION. Angiogenic factor-enriched PRP leads to faster and more extensive new bone formation in the critical size bone defect. The results implicate that rapid angiogenesis in the initial healing period by PRP could be supposed as a way to overcome short term effect of the rapid angiogenesis.

Recycling of Sintered Nd-Fe-B Magnets Doped with PrNd Nanoparticles

  • Zhang, Xuefeng;Liu, Fei;Liu, Yanli;Ma, Qiang;Li, Yongfeng;Zhao, Qian;Wang, Gaofeng;Li, Zhubai
    • Journal of Magnetics
    • /
    • v.20 no.2
    • /
    • pp.97-102
    • /
    • 2015
  • The waste of sintered Nd-Fe-B magnets was recycled using the method of dopingPrNd nanoparticles. The effect of PrNd nanoparticle doping on the magnetic properties of the regenerated magnets has been studied. As the content of the PrNd nanoparticles increases, the coercivity increases monotonically, whereas both the remanence and the maximum energy products reach the maximum values for 4 wt% PrNd doping. Microstructural observation reveals that the appropriate addition of PrNd nanoparticles improves the magnetic properties and refines the grain. Domain investigation shows that the self-pinning effect of the rare earth (Re)-rich phase is enhanced by PrNd nano-particle doping. Compared to the magnet with 4 wt% PrNd alloy prepared using the dual-alloy method, the regenerated magnet doped with the same number of PrNd nanoparticles exhibits better magnetic properties and a more homogeneous microstructure. Therefore, it is concluded that PrNd nanoparticle doping is an efficient method for recycling the leftover scraps of Nd-Fe-B magnets.

Development of a Femur Neck Bone Mineral Density Measuring Device for Accurate Examination

  • Han, Man-Seok;Seo, Sun-youl;Kim, Yong-Kyun;Jeon, Min-Cheol;Lee, Hyun-kuk;Yoo, Se-Jong
    • Journal of Magnetics
    • /
    • v.21 no.2
    • /
    • pp.298-302
    • /
    • 2016
  • In bone density examinations, a change in the measured BMD occurs owing to the differences between the measured areas. To address this problem, we aimed to develop a new auxiliary device that could be rotated by $15^{\circ}$ by fixing the ankle to the distal femur neck. Dual energy X-ray absorptiometry (DXA) of BMD examinations were performed once a year, but 10 patients were examined over three sessions to analyze the area for measuring the femur neck BMD. The goal of this test was to determine the device's reliability, and the results were expressed in terms of the standard deviation of measurements. After performing bone density measurements using the new auxiliary device on 10 normal patients, with three measurements for each patient, the obtained standard deviation was 0.03. The standard deviation of the measured BMD was 0.19 when using the currently existing auxiliary device, while the standard deviation of the measured BMD was 0.03 when using the new auxiliary device. By using the new auxiliary device, the standard deviation could be reduced by ~80%. Accurate rotation of the femur neck was possible in all examinations, and the standard deviation of BMD measurements could be reduced by up to 80% compared with the measurements performed using the currently existing auxiliary device. We hope that this advantageous new design can be used as a standard auxiliary device for measuring the femur neck BMD.

Development of $1.06/1.32{\mu}m$ Nd:YAG Laser and Dental Applications ($1.06/1.32{\mu}m$ Nd:YAG 레이저 개발 및 치과용 임상적용 연구)

  • Yoon, G.;Kim, H.S.;Hong, T.M.;Kim, J.B.;Lee, S.C.;Kim, W.K.;Zabaznov, A.;Tsvetkov, V.;Kim, J.H.;Oh, S.R.;Moon, J.W.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.11
    • /
    • pp.192-196
    • /
    • 1996
  • [ $1.06/1.32{\mu}m$ ] dual-wavelength medical laser was developed and preliminary clinical comparisons at these two wavelengths were performed for dental application. We could develop a compact laser system 1) by lasing two wavelengths from the same Nd:YAG rod, and 2) by introducing high-voltage switching power supply modules. Experiment on gingiva of pig jaw showed higher thermal damage at $1.32{\mu}m$. Depending on particular procedures, each wavelength has its own advantages and disadvantages. For cutting, however, using conical tips rather than bare fibers provided better results with low threshold of cutting energy and less surrounding thermal damage. Appling light-absorbing dye on target area appeared to induce more damage during laser irradiation. However, histological studies showed no significant difference whether dye was applied or not.

  • PDF

Relationship between the number of remaining teeth and bone health status among the elderly in Korea (한국 노인의 현존치아수와 골 건강상태와의 연관성)

  • Cho, Youn-Young
    • Journal of Korean society of Dental Hygiene
    • /
    • v.18 no.2
    • /
    • pp.205-215
    • /
    • 2018
  • Objectives: The purpose of the study is to investigate the relationship between the number of remaining teeth and bone health status among adults over 65 years old. Methods: The study subjects were 1,843 adults over 65 years old drawn from the Korea National Health and Nutrition Examination Survey (KNHANES) in 2008-2010. Oral health status included the number of remaining teeth, and prosthetic appliance status. Bone health statuses were assessed using dual-energy X-ray absorptiometry (DEXA). Bone health statuses were classified into normal (T-score ${\geq}-1.0$), osteopenia (-2.5 < T-score < -1.0), and osteoporosis (T-score ${\leq}-2.5$). Complex samples chi-square test was used to estimate the relationship between the number of remaining teeth and bone health status, and related factors included in the model were analyzed with the complex samples logistic regression analysis. Results: Using the multinomial logistic regression analytic method, the elderly having 20 or more remaining teeth and those having less than 20 remaining teeth with prosthesis were compared. The latter group had 1.89 times higher rate of being diagnosed as having osteoporosis. Conclusions: This study suggests that oral health is an important factor for geriatric osteoporosis. Therefore, in order to prevent fractures due to osteoporosis and osteoporosis in old age, it is necessary to be aware of the relationship between oral health and osteoporosis, and oral health should be considered when preparing preventive management strategies.

The Study on Performance and Emission of CNG as a Potential Fuel in Kore (한국의 잠재적인 연료인 CNG연료의 성능 및 배출물에 관한 연구)

  • Cho, Haeng-Muk;Chauhan, Bhupendra Singh
    • Journal of the Korean Institute of Gas
    • /
    • v.13 no.6
    • /
    • pp.39-43
    • /
    • 2009
  • Gasoline engine have proved its utility in light, medium and heavy duty vehicle in every sector of the world community. The concern about long term availability of petroleum and the increasing threat for the environment by the increasing load of vehicular emission, compel the technology to upgrade itself for meeting the challenges. CNG is environmentally clean alternative to the existing SI Engines with out much change in the hardware. Many researchers have found this as a potential substitute to meet the energy requirement. Higher octane number and higher self ignition temperature make it a good gaseous fuel. Although power output is slightly lesser than the gasoline it's thermal efficiency is better than the gasoline for the same SI Engine. Results showed that reduced CO, hydrocarbon emissions is a favorable outcome, with slight increase in NOx emission when compared with gasoline fuel to dual fuel mode in the existing SI Engines.

  • PDF

Optical and Electrical Properties of InAs Sub-Monolayer Quantum Dot Solar Cell

  • Han, Im-Sik;Park, Dong-U;No, Sam-Gyu;Kim, Jong-Su;Kim, Jin-Su;Kim, Jun-O
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.196.2-196.2
    • /
    • 2013
  • 본 연구에서는 분자선 에피택시 (MBE)법으로 성장된 InAs submonolayer quantum dot (SML-QD)을 태양전지에 응용하여 광학 및 전기적 특성을 평가하였다. 본 연구에서 사용된 양자점 태양전지(quantum dot solar cell, QDSC)의 구조는 n+-GaAs 기판 위에 n+-GaAs buffer와 n-GaAs base layer를 차례로 성장 한 후, 활성영역에 InAs/InGaAs SML-QD와 n-GaAs spacer layer를 8주기 형성하였다. 그 위에 p+-GaAs emitter, p+-AlGaAs window layer를 성장하고 ohmic contact을 위하여 p+-GaAs 를 성장하였다. SML-QD 구조의 두께는 0.3 ML 이며, 이때 SML-QD의 적층수를 4 stacks 으로 고정하였다. SML-QD 와의 비교를 위하여 2.0 ML크기의 InAs자발 형성 양자점 태양전지(SK-QDSC)과 GaAs 단일 접합 태양전지 (reference-SC)를 동일한 성장조건에서 제작하였다. PL 측정 결과, 300 K에서 SML-QD의 발광 피크는 SK-QD 보다 고에너지에서 나타나는데(1.349 eV), 이것은 SML-QD가 SK-QD보다 작은 크기를 가지기 때문으로 사료된다. SML-QD는 single peak를 보이는 반면, SK-QD는 dual peaks (1.112 / 1.056 eV)을 확인하였다. SML-QD의 반치폭(full width at half maximum, FWHM)이 SK-QD에 비하여 작은 것으로 보아 SML-QD가 SK-QD보다 양자점 크기 분포의 균일도가 높은 것으로 해석된다. Illumination I-V 측정 결과, SML-QDSC의 개방 전압(VOC) 과 단락전류밀도(JSC)는 SK-QDSC의 값과 비교해 보면, 각각 47 mV와 0.88 mA/cm2만큼 증가하였다. 이는 SK-QD보다 상대적으로 작은 크기를 가진 SML-QD로 인해 VOC가 증가되었으며, SML-QD가 SK-QD 보다 태양광을 흡수할 수 있는 영역이 비교적 적지만, QD내에 존재하는 energy level에서 탈출 할 수 있는 확률이 더 높음으로써 JSC가 증가한 것으로 분석 된다.

  • PDF

Quantitative Ultrasound for Osteoporosis Screening in Postmenopausal Women (폐경 후 여성에서 골다공증의 조기검진도구로서 골초음파의 유용성)

  • Shin, Hee-Young;Jung, Eun-Kyung;Rhee, Jung-Ae;Choi, Jin-Su;Shin, Min-Ho
    • Journal of Preventive Medicine and Public Health
    • /
    • v.34 no.4
    • /
    • pp.408-416
    • /
    • 2001
  • Objectives : To evaluate the diagnostic value of quantitative ultrasound (QUS) in the prediction of osteoporosis as defined by dual energy x-ray absorptiometry (DEXA) in postmenopausal women. Methods : Questionnaires and height and weight measurements were used in the investigation of 176 postmenopausal women. QUS measurements were taken on the right calcaneus while bone mineral density (BMD) measurements of the lumbar spine and femoral neck were made with DEXA. The areas under the curves (AUC) of the speed of sound (SOS) for osteoporosis in the lumbar spine and femoral neck were obtained through receiver operating characteristic (ROC) analysis and evaluated. A comparison was made, for osteoporosis in the lumbar spine and femoral neck, between the AUCs of the logistic model with clinical risk factors and SOS. Results : Pearson's correlation coefficients of SOS and lumbar spine BMD, and of SOS and femoral neck BMD were 0.26 and 0.37. The AUC for the logistic model in its discrimination for lumbar spine osteoporosis was 0.764, and for SOS 0.605. The AUCs for the logistic model in its discrimination for femoral neck osteoporosis and for SOS were 0.890 and 0.892, respectively. Conclusions : These results suggest that the diagnostic value of QUS as a screening tool for osteoporosis is moderate for the femoral neck, but merely low for the lumbar spine and that the predictability provided by SOS is no better than that by the sole use of clinical risk factors in postmenopausal women.

  • PDF

Coalition based Optimization of Resource Allocation with Malicious User Detection in Cognitive Radio Networks

  • Huang, Xiaoge;Chen, Liping;Chen, Qianbin;Shen, Bin
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.10 no.10
    • /
    • pp.4661-4680
    • /
    • 2016
  • Cognitive radio (CR) technology is an effective solution to the spectrum scarcity issue. Collaborative spectrum sensing is known as a promising technique to improve the performance of spectrum sensing in cognitive radio networks (CRNs). However, collaborative spectrum sensing is vulnerable to spectrum data falsification (SSDF) attack, where malicious users (MUs) may send false sensing data to mislead other secondary users (SUs) to make an incorrect decision about primary user (PUs) activity, which is one of the key adversaries to the performance of CRNs. In this paper, we propose a coalition based malicious users detection (CMD) algorithm to detect the malicious user in CRNs. The proposed CMD algorithm can efficiently detect MUs base on the Geary'C theory and be modeled as a coalition formation game. Specifically, SSDF attack is one of the key issues to affect the resource allocation process. Focusing on the security issues, in this paper, we analyze the power allocation problem with MUs, and propose MUs detection based power allocation (MPA) algorithm. The MPA algorithm is divided into two steps: the MUs detection step and the optimal power allocation step. Firstly, in the MUs detection step, by the CMD algorithm we can obtain the MUs detection probability and the energy consumption of MUs detection. Secondly, in the optimal power allocation step, we use the Lagrange dual decomposition method to obtain the optimal transmission power of each SU and achieve the maximum utility of the whole CRN. Numerical simulation results show that the proposed CMD and MPA scheme can achieve a considerable performance improvement in MUs detection and power allocation.