• Title/Summary/Keyword: Dual converter

Search Result 356, Processing Time 0.034 seconds

Development of a Dipstick Gage Type Small Engine oil Deterioration Detection Sensor (딥스틱게이지형 소형 엔진열화감지센서 개발)

  • Chun, Sang Myung
    • Tribology and Lubricants
    • /
    • v.29 no.2
    • /
    • pp.77-84
    • /
    • 2013
  • A small engine-oil-deterioration detection sensor was developed and installed at the tip of a dipstick gage. The sensor part was manufactured using printed circuit board (PCB) manufacturing technology. A set of sensor covers was installed in order to protect the sensor and realize good signal stability. The small engine-oil-deterioration detection sensor system comprised a dual sensor having etched copper electrodes coated with gold and ceramic, a flexible PCB (FPCB) acting as electric wire, and a dummy PCB with only a lock connector. The sensor can easily be installed by insertion through the guide tube of a dipstick gage. Thus, a driver can easily handle it without further installation equipment. The sensor can determine the level of deterioration in the engine oil by estimating the corresponding dielectric constant of the engine oil.

A 300MHz CMOS phase-locked loop with improved pull-in process (루프인식 속도를 개선한 300MHz PLL의 설계 및 제작)

  • 이덕민;정민수;김보은;최동명;김수원
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.33A no.10
    • /
    • pp.115-122
    • /
    • 1996
  • A 300MHz PLL including FVC (frequency to voltage converter) is designed and fabricated in 0.8$\mu$m CMOS process. In this design, a FVC and a 2nd - order passive filter are added to the conventional charge-pump PLL to improve the acquisition time. The dual-rijng VCO(voltage controlled oscillator) realized in this paper has a frequency range form 208 to 320MHz. Integrated circuits have been fully tested and analyzed in detail and it is proved that pull-in speed is enhanced with the use fo FVC. In VCO range from 230MHz to 310MHz, experimental results show that realized PLL exhibits 4 times faster pull-in speed than that of conventional PLL.

  • PDF

Phase modulated dual full-bridge converter for EV high-power on-board battery charger (전기자동차 탑재형 대용량 배터리 충전기를 위한 위상 변조 제어되는 듀얼 풀 브리지 컨버터)

  • Kim, Dong-Han;Kang, Dong-Hun;Jang, Hee-Beom;Lee, Il-Oun
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1002-1003
    • /
    • 2015
  • 본 논문에서는 전기자동차 탑재형 대용량 배터리 충전기를 위한 위상 변조되면서 제어되는 듀얼 풀 브리지 컨버터에 대한 연구결과를 발표한다. 제안되는 위상 변조 듀얼 풀 브리지 컨버터는 기존 대용량 풀 브리지 컨버터에 비해 약 50%이상 도통 손실이 개선되며, 변압기 이차측 정류단 전압스트레스 또한 크게 개선되는 이점을 갖고 있다. 더불어 배터리가 충전되는 전부하 구간에서 일차측 전력반도체스위치의 영전압 스위칭이 보장되며, 출력 필터 인덕터 사이즈 또한 크게 작아지는 장점도 갖고 있다. 논문에서는 제안 회로와 그 분석 결과가 발표되어 지고, 그 가능성은 6.6 kW급 배터리 충전기 시뮬레이션 결과로부터 확인되어진다.

  • PDF

A New Transformer Isolated Buck-Boost DC-DC Converter (새로운 절연형 Buck-Boost DC-DC 컨버터)

  • Cha, Hon-Nyong;Lee, Jong-Pil;Lee, Kyung-Jun;Kim, Tae-Jin;Yoo, Dong-Wook
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.154-155
    • /
    • 2010
  • 본 논문은 최소의 스위칭 소자를 이용한 절연형 Full-Bridge (FB) buck-boost DC-DC 컨버터를 제안한다. 기존의 dual-bridge 방식을 이용한 buck-boost 컨버터와는 달리 본 논문에서 제안한 방식은 변압기 1차측에만 스위칭 소자를 사용하고 2차측에는 다이오드 정류기를 사용한다. 필요한 buck-boost 기능을 구현하기 위하여 입력단에 2개의 인덕터를 추가하여 2 phase interleaved 방식으로 동작을 한다. 500 W 의 prototype을 제작하여 본 논문에서 제안한 방식의 타당성을 실험적으로 검증 한다.

  • PDF

DC-Link Active Power Filter for High-Power Single-Phase PWM Converters

  • Li, Hongbo;Zhang, Kai;Zhao, Hui
    • Journal of Power Electronics
    • /
    • v.12 no.3
    • /
    • pp.458-467
    • /
    • 2012
  • Single phase converters suffer from ripple power pulsating at twice the line frequency. The ripple power is usually absorbed by a bulky capacitor bank and/or a dedicative LC resonant link, resulting in a low power density and a high cost. An alternative solution is using a dc link active power filter (APF) to direct the pulsating power into another energy-storage component. The main dc link filter capacitor can then be reduced substantially. Based on a mainstream dc APF topology, this paper proposed a new control strategy incorporating both dual-loop control and repetitive control. The circuit parameter design is also re-examined from a control point of view. The proposed APF scheme has better control performance, and is more suited for high power applications since it works in CCM and with a low switching frequency.

An Charge-Recycling Technique with Dual Outputs for Field Color Sequential applied in the RGB LED Backlight

  • Yang, Chih-Yu;Hsieh, Chun-Yu;Chen, Ke-Horng
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.1088-1091
    • /
    • 2009
  • A boost converter with charge-recycling technique fabricated by $0.25{\mu}m$ CMOS BCD process can provide different supply voltages to drive series RGB LEDs in sequence for reducing the power consumption on the constant current generator. The proposed technique stores and restores extra energy to improve the efficiency, as well as enhances the reference tracking response. Experimental results show that the period of reference-tracking response can be improved. When the load current is 100mA, the periods of reference down-tracking and uptracking are smaller than $10{\mu}s$ and $20{\mu}s$, respectively. Experimental results demonstrate fast and efficient reference tracking performance is achieved.

  • PDF

Isolated bidirectional DC-DC Converter for low voltage battery charger (저전압 배터리 충전용 절연형 양방향 DC-DC 컨버터)

  • Jeong, Dong-Keun;Ryu, Myung-Hyo;Baek, Joo-Won;Kim, Hee-Je
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.198-199
    • /
    • 2013
  • 본 논문은 군용 UPS 시스템에서 Dual Active Bridge(DAB) 컨버터를 이용한 절연형 양방향 배터리 충전기를 제안한다. 일반적인 군용 UPS 시스템은 AC-DC 정류기, DC-AC 인버터, 양방향 DC-DC 컨버터, 배터리 충전기, 배터리로 구성되며, 여러 부하상태들에 대한 지속적인 전력공급을 위하여 안정적인 에너지 저장 시스템이 요구된다. 다양한 양방향 DC-DC 컨버터들 중, DAB 컨버터는 buck, boost 동작이 가능한 고효율 절연형 양방향 컨버터이다. 본 논문에서는 6kW(입력 380Vdc, 출력 32/21Vdc) DAB 컨버터에 대한 토폴로지 분석하고, 파라미터 및 제어 알고리즘 설계를 제안하고 시제품을 통해 이를 검증하였다.

  • PDF

Design of Transformer Turn-ratio through Switch Loss Analysis in Bidirectional DC-DC Converter for EDLC (스위치 손실 분석을 통한 슈퍼커패시터용 양방항 DC-DC 컨버터의 변압기 권선비 설계)

  • Kim, Hak-Soo;Jung, Jae-Hun;Nho, Eui-Cheol;Kim, In-Dong;Kim, Heung-Geun;Chun, Tae-Won;Choi, Nam-Sup
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.3-4
    • /
    • 2013
  • 본 논문은 슈퍼커패시터용 양방향 DC-DC 컨버터의 충 방전 시의 스위치 손실 분석을 통한 변압기 권선비 설계에 관한 내용이다. Dual Full-Bridge 방식의 양방향 DC-DC 컨버터의 충 방전 동작분석을 통하여 스위치에서 발생하는 손실을 분석하고 변압기 권선비를 달리하여 각 손실을 비교했을 때 가장 작은 손실을 갖는 변압기 권선비를 파악하여 설계에 반영하였다.

  • PDF

A Series Operation Algorithm For Voltage Balancing Between Modules Of Modular Battery Pack Charging/Discharging System (모듈러 배터리팩 충·방전기의 모듈 간 전압 밸런싱을 위한 직렬 운전 알고리즘)

  • Lee, Yoon-Seong;Kang, Kyung-Min;Choi, Bong-Yeon;Kim, Mi Na;Lee, Hoon;Won, Chung-Yuen
    • Proceedings of the KIPE Conference
    • /
    • 2019.11a
    • /
    • pp.140-141
    • /
    • 2019
  • This paper proposes a series operation algorithm for voltage balancing of modular battery pack charging/discharging system using 3P-CFDAB (3-Phase Current-Fed Dual Active Bridge) converter. By using the proposed algorithm, we can prevent deterioration or loss of a particular module. The algorithm in this paper was verified through PSIM simulation.

  • PDF

Short-term Run and Short-circuit Test of 6.6㎸/200A DC reactor Type Superconducting Fault Current Limiter (6.6㎸/200A급 DC 리액터헝 초전도한류기의 단시간운전 및 단락시험)

  • 안민철;이승제;강형구;배덕권;윤용수;고태국
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.10a
    • /
    • pp.10-13
    • /
    • 2003
  • 6.6㎸rms/200Arms DC reactor type superconducting fault current limiter (SFCL) has been developed. This paper deals with the manufacture and short-circuit test of the SFCL. DC reactor was the HTS solenoid coil whose inductance was 84mH. AC/DC power converter was performed as the dual-mode operation. The short-term run(1 sec) and short-circuit test of this SFCL was performed successfully. The experimental results have a similar tendency to the simulation results. In short-circuit test, at 2 cycles after the fault, fault current limitation rate was about 30%.

  • PDF