• Title/Summary/Keyword: Dual camera

Search Result 127, Processing Time 0.033 seconds

A Study on Free Indirect Discourse Emerged in the (영화 <여자, 정혜>에 연출된 자유간접화법의 의미 분석)

  • Kim, Jong-Wan
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.9
    • /
    • pp.60-68
    • /
    • 2017
  • Through this thesis, I wanted to understand the form of free indirect discourse of modern films. To this end, I first explored the notion of the polyphonie as a mixture of the speaker and the character' voice in order to establish a concept related to free indirect discourse. However, I could not overlook the differences in the form of novels and movies to apply the following theory to films. Based on the concept of narrative distance, I sought to explore the possibility of free indirect discourse from the dual position of the camera. Next, I introduced the concept of free indirect discourse in the film by introducing the concept of Time in G. Deleuze' CinemaII. In other words, the time from Deleuze is the past and the present cycle, and he sees the Time circulating like the Non-Euclidean space. I wanted to understand the form of free indirect discourse in films by analyzing the concept of Time as an analysis of the movie .

A Buffer Management Algorithm based on the GOP Pattern and the Importance of each Frame to Provide QoS for Streaming Services in WLAN (WLAN에서 스트리밍 서비스이 QoS를 제공하기 위한 GOP 패턴 및 프레임 중요도에 따른 버퍼 관리 기술)

  • Kim, Jae-Hyun;Lee, Hyun-Jin;Lee, Kyu-Hwan;Roh, Byeong-Hee
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2008.08a
    • /
    • pp.372-375
    • /
    • 2008
  • IEEE 802.11e standardized the EDCA mechanism to support the priority based QoS. And the virtual collision handler schedules the transmission time of each MAC frame using the internal back-off window according to the access category(AC). This can provides the differentiated QoS to real-time services at the medium traffic load condition. However, the transmission delay of MAC frame for real-time services may be increased as the traffic load of best effort service increases. It becomes more critical when the real-time service uses a compressed mode video codec such as moving picture experts group(MPEG) 4 codec. That is because each frame has the different importance. That is, the I-frame has more information as compared with the P- and the B-frame. In this paper, we proposed a buffer management algorithm based on the frame importance and the delay bound. The proposed algorithm is consisted of the traffic regulator based on the dual token bucket algorithm and the active queue management algorithm. The traffic regulator reduces the transmission rate of lower AC until that the virtual collision handler can transmit an I-frame. And the active queue management discards frame based on the importance of each frame and the delay bound of head of line(HoL) frame when the channel resource is insufficient.

  • PDF

Characterization of stacked geotextile tube structure using digital image correlation

  • Dong-Ju Kim;Dong Geon Son;Jong-Sub Lee;Thomas H.-K. Kang;Tae Sup Yun;Yong-Hoon Byun
    • Computers and Concrete
    • /
    • v.31 no.5
    • /
    • pp.385-394
    • /
    • 2023
  • Displacement is an important element for evaluating the stability and failure mechanism of hydraulic structures. Digital image correlation (DIC) is a useful technique to measure a three-dimensional displacement field using two cameras without any contact with test material. The objective of this study is to evaluate the behavior of stacked geotextile tubes using the DIC technique. Geotextile tubes are stacked to build a small-scale temporary dam model to exclude water from a specific area. The horizontal and vertical displacements of four stacked geotextile tubes are monitored using a dual camera system according to the upstream water level. The geotextile tubes are prepared with two different fill materials. For each dam model, the interface layers between upper and lower geotextile tubes are either unreinforced or reinforced with a cementitious binder. The displacement of stacked geotextile tubes is measured to analyze the behavior of geotextile tubes. Experimental results show that as upstream water level increases, horizontal and vertical displacements at each layer of geotextile tubes initially increase with water level, and then remain almost constant until the subsequent water level. The displacement of stacked geotextile tubes depends on the type of fill material and interfacial reinforcement with a cementitious binder. Thus, the proposed DIC technique can be effectively used to evaluate the behavior of a hydraulic structure, which consists of geotextile tubes.

Radiation Absorbed Dose Calculation Using Planar Images after Ho-166-CHICO Therapy (Ho-166-CHICO 치료 후 평면 영상을 이용한 방사선 흡수선량의 계산)

  • 조철우;박찬희;원재환;왕희정;김영미;박경배;이병기
    • Progress in Medical Physics
    • /
    • v.9 no.3
    • /
    • pp.155-162
    • /
    • 1998
  • Ho-l66 was produced by neutron reaction in a reactor at the Korea Atomic Energy Institute (Taejon, Korea). Ho-l66 emits a high energy beta particles with a maximum energy of 1.85 MeV and small proportion of gamma rays (80 keV). Therefore, the radiation absorbed dose estimation could be based on the in-vivo quantification of the activity in tumors from the gamma camera images. Approximately 1 mCi of Ho-l66 in solution was mixed into the flood phantom and planar scintigraphic images were acquired with and without patient interposed between the phantom and scintillation camera. Transmission factor over an area of interest was calculated from the ratio of counts in selected regions of the two images described above. A dual-head gamma camera(Multispect2, Siemens, Hoffman Estates, IL, USA) equipped with medium energy collimators was utilized for imaging(80 keV${\pm}$10%). Fifty-nine year old female patient with hepatoma was enrolled into the therapeutic protocol after the informed consent obtained. Thirty millicuries(110MBq) of Ho-166-CHICO was injected into the right hepatic arterial branch supplying hepatoma. When the injection was completed, anterior and posterior scintigraphic views of the chest and pelvic regions were obtained for 3 successive days. Regions of interest (ROIs) were drawn over the organs in both the anterior and posterior views. The activity in those ROIs was estimated from geometric mean, calibration factor and transmission factors. Absorbed dose was calculated using the Marinelli formula and Medical Internal Radiation Dose (MIRD) schema. Tumor dose of the patient treated with 1110 MBq(30 mCi) Ho-l66 was calculated to be 179.7 Gy. Dose distribution to normal liver, spleen, lung and bone was 9.1, 10.3, 3.9, 5.0 % of the tumor dose respectively. In conclusion, tumor dose and absorbed dose to surrounding structures were calculated by daily external imaging after the Ho-l66 therapy for hepatoma. In order to limit the thresholding dose to each surrounding organ, absorbed dose calculation provides useful information.

  • PDF

Evaluation of Usefulness of Portal Image Using Electronic Portal Imaging Device (EPID) in the Patients Who Received Pelvic Radiation Therapy (골반강 내 방사선 치료 환자에서 Electronic Portal Imaging Device(EPID)를 이용한 Portal Image의 유용성에 관한 연구)

  • Kim Woo Chul;Park Won;Kim Heon Jong;Park Seong Young;Cho Young Kap;Loh John J;Suh Chang Ok;Kim Gwi Eon
    • Radiation Oncology Journal
    • /
    • v.16 no.4
    • /
    • pp.497-504
    • /
    • 1998
  • Purpose : To evaluate the usefulness of electronic portal imaging device through objective compare of the images acquired using an EPID and a conventional port film Materials and Methods : From Apr. to Oct. 1997, a total of 150 sets of images from 20 patients who received radiation therapy in the pelvis area were evaluated in the Inha University Hospital and Severance Hospital. A dual image recording technique was devised to obtain both electronic portal images and port film images simultaneously with one treatment course. We did not perform double exposure five to ten images were acquired from each patient. All images were acquired from posteroanterior (PA) view except images from two patients. A dose rate of 100-300 Mu/min and a 10-MV X-ray beam were used and 2-10 MUs were required to produce a verification image during treatment. Kodak diagnostic film with metal/film imaging cassette which was located on the top of the EPID detector was used for the port film. The source to detector distance was 140 cm. Eight anatomical landmarks (pelvic brim, sacrum, acetabulum. iliopectineal line, symphysis, ischium, obturator foramen, sacroiliac joint) were assessed. Four radiation oncologist joined to evaluate each image. The individual landmarks in the port film or in the EPID were rated - very clear (1), clear (2), visible (3), not clear (4), not visible (5). Results : Using an video camera based EPID system. there was no difference of image quality between no enhanced EPID images and port film images. However, when we provided some change with window level for the portal image, the visibility of the sacrum and obturator foramen was improved in the portal images than in the port film images. All anatomical landmarks were more visible in the portal images than in the port film when we applied the CLAHE mode enhancement. The images acquired using an matrix ion chamber type EPID were also improved image qualify after window level adjustment. Conclusion : The quality of image acquired using an electronic portal imaging device was comparable to that of the port film. When we used the enhance mode or window level adjustment. the image quality of the EPID was superior to that of the port film. EPID may replace the port film.

  • PDF

KOREAN PARTICIPATION ON THE COSMIC INFRARED BACKGROUND EXPERIMENT 2 (CIBER2) (적외선 우주배경복사 관측 실험 2(CIBER2) 국제 공동 연구)

  • Lee, D.H.;Park, W.K.;Moon, B.G.;Park, S.J.;Kim, M.G.;Kim, G.H.;Nam, U.W.;Pyo, J.;Jeong, W.S.;Park, Y.S.;Kim, I.J.;Han, W.
    • Publications of The Korean Astronomical Society
    • /
    • v.30 no.1
    • /
    • pp.11-16
    • /
    • 2015
  • First light galaxies have predictable linear clustering, and are expected to produce fluctuations with a characteristic spatial power spectrum, which peaks at an angular scale of ~ 10 arcminutes and in the $1-2{\mu}m$ spectral regions. The Cosmic Infrared Background ExpeRiment 2 (CIBER2) is a dedicated sounding rocket mission for measuring the fluctuations in the extragalactic infrared background light, following up the previous successful measurements of CIBER1. With a 28.5 cm telescope accompanied with three arms of camera barrels and a dual broadband filter on each H2RG (${\lambda}_c=2.5{\mu}m$) array, CIBER2 can measure 6 bands of wide field ($1.1{\times}2.2$ degrees) up to 3 AB magnitudes deeper than CIBER1. This project is leaded by California Institute of Technology/Jet Propulsion Laboratory, collaborating internationally with Institute of Space and Astronautical Science in Japan, Korea Astronomy and Space Science Institute, Korea Basic Science Institute, and Seoul National University. The Korean team is in charge of 1) one H2RG scientific array, 2) ground station hardware and software, 3) telescope lenses, and 4) flight and test bed electronics fabrication. In this paper, we describe the detailed activities of the Korean participation as well as the current status of the CIBER2 project.

The Clinical Role of $^{99m}Tc$-(V)-DMSA Imaging in Patients with Head and Neck Cancer (두경부 종양에서 $^{99m}Tc$-(V)-DMSA 영상술의 진단적 유용성)

  • Bae, Sun-Kun;Lee, Jae-Tae;Park, June-Sik;Park, In-Kyu;Hyun, Dong-Woo;Lee, Young-Hak;Kim, Jeong-Gyun;Ahn, Byeong-Cheal;Choi, Ji-Yong;Sohn, Sang-Gyun;Lee, Kyu-Bo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.4
    • /
    • pp.526-532
    • /
    • 1995
  • Introduction : $^{99m}Tc$-(V)-DMSA is a tumor seeking agent that has been used to image medullary carcinoma of thyroid, soft tissue sarcoma and lung cancer. This study was designed to assess the clinical role of $^{99m}Tc$-(V)-DMSA in the diagnosis of head and neck cancers. We has evaluated the diagnostic efficacy of planar and SPECT imaging using $^{99m}Tc$-(V)-DMSA. Patients and Method : Sixty-eight patients with head and neck mass were included in this study. All subjects were diagnosed by biopsy or surgery. Planar and SPECT images were obtained at 2 or 3 hour after intravenous injection of 740 MBq(20 mCi) $^{99m}Tc$-(V)-DMSA. Seventeen patients also underwent SPECT in aging using dual head camera. Result : The diagnostic sensitivity of $^{99m}Tc$-(V)-DMSA planar and SPECT imaging was 65% and 90%, and specificity was 80% and 66%, respectively. The sensitivity of planar imaging in squamous cell carcinoma was similar to overall sensitivity Six metastatic lesion were first diagnosed by scintigraphy. But benign lesions such as Kikuchi syndrome, tuberculous lymphadenitis also revealed increased uptake. Conclusion : $^{99m}Tc$-(V)-DMSA imaging seems to be a promising method in the evaluation of patients with head and neck mass. We recommend SPECT imaging to delineate anatomic localization of the lesion.

  • PDF

The Comparison of Image Quality Using Body Contour and Circular Method with L-mode in Myocardial Perfusion SPECT (Tl-201을 이용한 심근관류 SPECT에서 Body contour와 Circular mode의 영상 획득 차이에 따른 영상의 질 비교)

  • Kim, Sung-Hwan;Nam, Ki-Pyo;Ryu, Jae-Kwang;Yoon, Soon-Sang
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.3-7
    • /
    • 2012
  • Purpose : In myocardial perfusion SPECT, the type of orbit (circular vs. body contouring) that affect the image quality is still on the debate. Presently in the nuclear medicine field, the body contouring orbit acquisition is widely used to improve the image quality on the myocardial perfusion SPECT. But in case of body contouring acquisition using the vertical method with dual detect machine, there is a tendency of increasing the radius. In this research, we compared body contouring orbit acquisition with circular orbit acquisition, so we suggest ideal method that reduces the radius for improving image quality. Materials and Methods : Phantom and clinical studies were performed. The anthropomorphic torso phantom was made on equally with counts from patient's body. The study was performed under six different conditions. To compare image quality according to the radius, we increased radius sequentially per step during circular orbit acquisition. On the other hand, sensors that protect a collision and reduce the radius automatically were used to acquire image during body contouring orbit acquisition. So we compared FWHM value of apex. In clinical studies, we analyzed the 40 patients who were examined by Tl-201 gated myocardial perfusion SPECT in department of nuclear medicine at Asan Medical Center in August 2011. To acknowledge the differences according to the radius, we acquired the results two times using circular orbit acquisition and body contouring orbit acquisition. Results : In phantom study, we analyzed that increase of radius resulted in changes of FWHM value. It was 5.41, 6.24, 6.33, 6.42, 6.93 mm. On the other hand, using the body contouring orbit acquisition, FWHM value was 6.23 mm. In clinical study, difference of average radius between two methods was 2.5 cm (circular orbit acquisition was more close to patients). Conclusion : Through the experiments using Anthropomorphic torso phantom and patients data, we found that FWHM value of circular orbit acquisition was lower than body contouring orbit acquisition. As a result, if the difference of average radius exists approximately 3 cm, circular orbit type acquisition is better than body contouring type acquisition. But clinical investigation is only aimed to average radius, so it needs more investigation in comparison of patient's image.

  • PDF

Reference Values of Functional Parameters in Gated Myocardial Perfusion SPECT : Comparison with $QGS^{\circledR}$ and $4DM^{\circledR}$ Program (게이트 심근 관류 스펙트의 심기능 지표의 정상 참고값 : $QGS^{\circledR}$ 프로그램과 $4DM^{\circledR}$ 프로그램의 비교)

  • Jeong, Young-Jin;Park, Tae-Ho;Cha, Kwang-Soo;Kim, Moo-Hyun;Kim, Young-Dae;Kang, Do-Young
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.6
    • /
    • pp.430-437
    • /
    • 2005
  • Purpose: The objectives of this study were - First, to determine the normal range of left ventricular end diastolic volume (EDV), end systolic volume (ESV) and election fraction (EF) from gated myocardial perfusion SPECT for Quantitative Gated SPECT (QGS) and 4D-MSPECT (4DM), respectively. Second, to evaluate the relationships between values produced by both software packages. Materials & Methods: Tc-99m MIBI gated myocardial perfusion SPECT were performed for 77 patients (mean age: $49.6{\pm}13.7y$, n=37(M), 40(F)) with a low likelihood (<10%) of coronary artery disease (CAD) using dual head gamma camera (E.CAM, Siemens, USA). Left ventricular EDV, ESV and EF were automatically measured by means of QGS and 4DM, respectively. Results: in QGS, the mean EDV, ESV and EF for all patients were $78.2{\pm}25.2ml,\;27.4{\pm}12.9ml\;and\;66.6{\pm}8.0%$ at stress test respectively, not different from rest test (p>0.05). In 4DM, the mean EDV, ESV and EF for all patients were $89.1{\pm}26.4ml,\;29.1{\pm}12.8ml\;and\;68.5{\pm}6.7%$ at stress test. Most cases in 4DM, there was no significant difference statistically between stress and rest test (p>0.05). But statistically significant difference was found in EF ($68.5{\pm}6.7%$ at stress vs $70.9{\pm}8.0%$ at rest, p<0.05). Correlation coefficients between the methods for EDV, ESV and EF were comparatively high (0.95, 0.93, 0.71 at stress test and 0.95, 0.90, 0.69 at rest test, respectively). However, Bland-Altman plots showed a large range of the limit value of agreement for EDV, ESV and EF between both methods ($-30ml{\sim}10ml,\;-12ml{\sim}8ml,\;-14%{\sim}11%$ at stress test and $-32ml{\sim}5ml,\;-13ml{\sim}13ml,\;-18%{\sim}12%$ at rest test). Conclusion: We found the normal ranges of EDV, ESV and EF for patients with a low likelihood of CAD in both methods. We expect these values will be a good reference to interpret gated myocardial perfusion SPECT. Although good correlation was observed between both methods, they should not be used interchangeably. Therefore, when both programs are used at the same site, it will be important to apply normal limits specific to each method.

Assessment of Vascularization within Hydroxyapatite Ocular Implant by Bone Scintigraphy: Comparative Analysis of Planar and SPECT Imaging (Hydroxyapatite 안구보충물삽입술 후 골신티그라피를 이용한 섬유혈관증식 평가: 평면영상과 SPECT 영상에서의 비교)

  • Lim, Seok-Tae;Sohn, Myung-Hee;Park, Soon-Ah
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.6
    • /
    • pp.475-483
    • /
    • 1999
  • Purpose: Complete fibrovascular ingrowth within the hydroxyapatite ocular implant is necessary for peg drilling which is performed to Prevent infection and to provide motility to the ocular prosthesis. We compared planar bone scintigraphy and SPECT for the evaluation of the vascularization within hydroxyapatite ocular implants. Materials and Methods: Seventeen patients (M:F: 12:5, mean age; $50.4{\pm}17.5$ years) who had received a coralline hydroxyapatite ocular implant after enucleation surgery were enrolled. Patients underwent Tc-99m MDP planar bone and SPECT imaging by dual head gamma camera after their implant surgery (interval: $197{\pm}81$ days). Uptake on planar and SPECT images was graded visually as less than (grade 1), equal to (grade 2), and greater than (grade 3) nasal bridge activity. Quantitative ratio of implanted to non-implanted intraorbital activity was also measured. Vascularization within hydroxyapatite implants was confirmed by slit lamp examination and ocular movement. Results: All but three patients were considered to be vascularized within hydroxyapatite implants. In visual analysis of planar image and SPECT, grade 1 was noted in 9/18 (50%) and 6/18 (33%), respectively. Grade 2 pattern was 7/18 (39%) and 4/18 (22%), and grade 3 pattern was 2/18 (11%) and 8/18 (44%) respectively. When grade 2 or 3 was considered to be positive for vascularization, the sensitivity of planar and SPECT imaging were 60% (9/15) and 80% (12/15), respectively. In 3 patients with incomplete vascularization, both planar and SPECT showed grade 1 uptake The orbital activity ratios on planar imaging were not significantly different between complete and incomplete vascularization ($1.96{\pm}0.87$ vs $1.17{\pm}0.08$, p>0.05), however, it was significantly higher on SPECT in patients with complete vascularization ($8.44{\pm}5.45$ vs $2.20{\pm}0.87$, p<0.05). Conclusion: In the assessment of fibrovascular ingrowth within ocular implants by Tc-99m MDP bone scintigraphy, SPECT image appears to be more effective than planar scintigraphy.

  • PDF