• 제목/요약/키워드: Dual approach

검색결과 472건 처리시간 0.029초

CD/DVD 겸용 광 픽업 액추에이터의 설계 (CD/DVD Compatible Optical Pickup Actuator Design)

  • 이문구;권대갑;이관철;정회원
    • 한국정밀공학회지
    • /
    • 제15권7호
    • /
    • pp.98-103
    • /
    • 1998
  • Recently, DVD/CD compatible driver is needed for DVD and CD is widely used as a new optical data restoring device. The optical systems of DVD and CD driver are different because they have different optical feature. If only one objective lens is used, the change of an aperture or a dual focal length of the lens is required. This method, however, increases the number of parts and results in loss of the power of laser light. Hence, we propose a dual lens actuator design that can read DVD and CD respectively. Albeit magnetic spring is important mechanism in the dual lens actuator design, there has not been the systematic approach to design the mechanism in the preceding researches. In this article. the guideway to design magnetic spring is presented by using the qualitative theoretical approach and the finite element analysis.

  • PDF

A MODEL OF RETIREMENT AND CONSUMPTION-PORTFOLIO CHOICE

  • Junkee Jeon;Hyeng Keun Koo
    • 대한수학회보
    • /
    • 제60권4호
    • /
    • pp.1101-1129
    • /
    • 2023
  • In this study we propose a model of optimal retirement, consumption and portfolio choice of an individual agent, which encompasses a large class of the models in the literature, and provide a methodology to solve the model. Different from the traditional approach, we consider the problems before and after retirement simultaneously and identify the difference in the dual value functions as the utility value of lifetime labor. The utility value has an option nature, namely, it is the maximized value of choosing the retirement time optimally and we discover it by solving a variational inequality. Then, we discover the dual value functions by using the utility value. We discover the value function and optimal policies by establishing a duality between the value function and the dual value function. The model and approach offer a significant advantage for computation of optimal policies for a large class of problems.

Adaptive Dual Fuzzy 알고리즘을 이용한 고층 빌딩의 엘리베이터 군 제어에 관한 연구 (A study on Elevator Group Controller of High Building using Adaptive Dual Fuzzy Algorithm)

  • 최승민;김훈모
    • 한국정밀공학회지
    • /
    • 제18권4호
    • /
    • pp.112-120
    • /
    • 2001
  • In this paper, the development of a new group controller for high-speed elevator is carried out utilizing the approach of an adaptive dual fuzzy logic. Some goals of control are the minimization of waiting time, mean-waiting time and long-waiting time in a high building, when a new hall call is generated, adaptive dual fuzzy controller evaluate traffic pattern and change appropriately the membership function of a fuzzy rule base. Controls for co-operation among elevators in a group control algorithm arte essential, and the most critical control function in the group controller is an effective and proper hall call assignment of elevators. The group elevator system utilizing adaptive dual fuzzy control reveals a great deal of improvement on its performance.

  • PDF

Adaptive Dual Fuzzy 알고리즘을 이용한 빌딩의 엘리베이터 군 제어기 설계 (A Design for Elevator Group Controller of Building using Adaptive Dual Fuzzy Algorithm)

  • 최승민;김훈모
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.578-581
    • /
    • 2001
  • In this paper, the development of a new group controller for high-speed elevator is carried out utilizing approach of an adaptive dual fuzzy logic. A goals of control are the minimization of waiting time, mean-waiting time and long-waiting time in a building. when a new hall call is generated, adaptive dual fuzzy controller evaluate traffic pattern and change appropriately the membership function of fuzzy rule base. Control for co-operation among elevators in group control algorithm are essential, and the most critical control function in group controller is a effective and proper hall call assignment of elevators. Thy group elevator system utilizing adaptive dual fuzzy control reveals a great deal of improvement on its performance.

  • PDF

Adaptive Dual Fuzzy 알고리즘을 이용한 엘리베이터 군 제어 시뮬레이션 (A Simulation of Elevator Group Controller using Adaptive Dual Fuzzy Algorithm)

  • 최승민;김훈모
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2000년도 추계학술대회 논문집
    • /
    • pp.157-160
    • /
    • 2000
  • In this paper, the development of a new group controller for high-speed elevator is carried out utilizing approach of an adaptive dual fuzzy logic. A goals of control are the minimization of waiting time, mean-waiting time and long-waiting time in a high building, when a new hall call is generated, adaptive dual fuzzy controller evaluate traffic pattern and change appropriately the membership function of fuzzy rule, base. Control for co-operation among elevators in group control algorithm are essential , and the most critical control function in group controller is a effective and proper hall call assignment of elevators. The group elevator system utilizing adaptive dual fuzzy control reveals a great deal of improvement on its performance.

  • PDF

An Ant Colony Optimization Approach for the Two Disjoint Paths Problem with Dual Link Cost Structure

  • 정지복;서용원
    • 한국경영과학회:학술대회논문집
    • /
    • 한국경영과학회 2008년도 추계학술대회 및 정기총회
    • /
    • pp.308-311
    • /
    • 2008
  • The ant colony optimization (ACO) is a metaheuristic inspired by the behavior of real ants. Recently, ACO has been widely used to solve the difficult combinatorial optimization problems. In this paper, we propose an ACO algorithm to solve the two disjoint paths problem with dual link cost structure (TDPDCP). We propose a dual pheromone structure and a procedure for solution construction which is appropriate for the TDPDCP. Computational comparisons with the state-of-the-arts algorithms are also provided.

  • PDF

최소비용문제의 해법 효율화와 통합구현 (Performance Improvement and Integrated Implementation for Minimum Cost Flow Problem)

  • 정호연
    • 산업경영시스템학회지
    • /
    • 제20권43호
    • /
    • pp.67-79
    • /
    • 1997
  • In this paper we develop the integrated software that can compare algorithms of the minimum cost flow problem using PC. The chosen algorithms are the network simplex method, dual network simplex method, and out-of-kilter method, which methods correspond to primal, dual, and primal-dual approach respectively. We also present the improved methods obtaining the initial solution to increase the efficiency of algorithms, and experiment results shown the difference between the entering(dropping) selection rules.

  • PDF

Wind fragility analysis of RC chimney with temperature effects by dual response surface method

  • Datta, Gaurav;Sahoo, Avinandan;Bhattacharjya, Soumya
    • Wind and Structures
    • /
    • 제31권1호
    • /
    • pp.59-73
    • /
    • 2020
  • Wind fragility analysis (WFA) of concrete chimney is often executed disregarding temperature effects. But combined wind and temperature effect is the most critical limit state to define the safety of a chimney. Hence, in this study, WFA of a 70 m tall RC chimney for combined wind and temperature effects is explored. The wind force time-history is generated by spectral representation method. The safety of chimney is assessed considering limit states of stress failure in concrete and steel. A moving-least-squares method based dual response surface method (DRSM) procedure is proposed in WFA to alleviate huge computational time requirement by the conventional direct Monte Carlo simulation (MCS) approach. The DRSM captures the record-to-record variation of wind force time-histories and uncertainty in system parameters. The proposed DRSM approach yields fragility curves which are in close conformity with the most accurate direct MCS approach within substantially less computational time. In this regard, the error by the single-level RSM and least-squares method based DRSM can be easily noted. The WFA results indicate that over temperature difference of 150℃, the temperature stress is so pronounced that the probability of failure is very high even at 30 m/s wind speed. However, below 100℃, wind governs the design.

A dual-plane approach for surgical treatment of pseudoaneurysm with arteriovenous fistula in hemodialysis patients

  • Kim, Ji Min;Tak, Min Sung;Kang, Jin Seok;Moon, Chul
    • Archives of Plastic Surgery
    • /
    • 제48권3호
    • /
    • pp.287-292
    • /
    • 2021
  • Background We report the efficacy of a dual-plane approach using a Dufourmentel skin flap with a purse-string suture of the de-epithelized dermis to manage pseudoaneurysm at the vascular access site for hemodialysis. Methods A retrospective analysis was conducted of 61 patients from 2013 to 2018 with pseudoaneurysms at the arteriovenous fistula or graft who were treated with rhomboid excision, vessel repair with a purse-string suture, and a full-thickness Dufourmentel skin flap. The success rate was defined as the probability of complete wound closure and intact vascular access patency without infection or other complications. Results The success rate was 93.4% at 6 months postoperatively. Complications included newly occurring pseudoaneurysms (n=2), wound dehiscence (n=1) and bleeding (n=1). There were no complications such as stenosis or thrombosis from the procedure. Conclusions A dual-plane approach using a Dufourmentel skin flap with a purse-string suture for vessel repair was shown to be a favorable option for managing stable, small (diameter <2 cm) pseudoaneurysms without infection, rapid expansion, or patency issues of the vascular access.

Fully Printed Dual-Band Power Divider Miniaturized by CRLH Phase-Shift Lines

  • Eom, Da-Jeong;Kahng, Sungtek
    • ETRI Journal
    • /
    • 제35권1호
    • /
    • pp.150-153
    • /
    • 2013
  • In this letter, a compact and fully printed composite right- and left-handed (CRLH) dual-band power divider is proposed. The branches of the conventional Wilkinson power divider are replaced by subwavelength CRLH phase-shift lines having $+90^{\circ}$ for one frequency and $-90^{\circ}$ for another frequency for dual-band and miniaturization performance. Equations are derived for the even- and odd-mode analysis combined with the dual-band CRLH circuit. A PCS and a WLAN band are chosen as the test case and the circuit approach agrees with the CAD simulation and the measurement. Additionally, the CRLH property is shown with the dispersion diagram and the eightfold size reduction is noted.