전자계-기계계 결합해석에 의한 건식변압기의 단락강도 예측 (Short Circuit Electromagnetic Force Prediction by Coupled Electromagnetic-Mechanical Field Analysis of Dry-Type Transformer)

  • 안현모;한성진
    • 전기학회논문지
    • /
    • 제60권2호
    • /
    • pp.301-308
    • /
    • 2011
  • This paper deals with the coupled electromagnetic-mechanical field analysis for short-circuit electromagnetic force of the dry-type transformer. The short-circuit currents are calculated using external circuit in accordance with short-circuit test equipment. According to short-circuit current, the generated magnetic leakage flux density in dry-type transformer model is calculated by finite element method. The radially-directed electromagnetic forces in windings are calculated using electromagnetic field analysis and then axially-directed electromagnetic forces in windings are calculated using electromagnetic-mechanical field analysis. The calculated axially-directed electromagnetic forces in high voltage winding are compared to those of measured ones and showed good agreement with experimental results.

건식변압기 수명예측에 관한 연구 (A Study on the lifetime Expectation of Dry type Transformer)

  • 김민규;이정기;정주영;김익수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.2106-2108
    • /
    • 2005
  • This paper describes a method of lifetime expectation for the dry-type molded transformer which is widely used in the domestic distribution system. And the result of the temperature accelerated aging test for the winding insulation and the analyzed report on the reliability are included in this study.

  • PDF

몰드변압기의 부분방전 검출기술에 관한 연구 (A Study on PD Detection Methods for Cast-resin Dry-type Transformers)

  • 박찬용;박대원;최재성;길경석
    • 한국전기전자재료학회논문지
    • /
    • 제22권9호
    • /
    • pp.786-791
    • /
    • 2009
  • Transformer failures are mostly due to partial discharges (PDs) caused by the deteriorated insulation. It is, therefore, important to monitor PD occurrence in insulation system and prevent their deterioration. The presented paper deals with a PD detection method by a capacitive probe, which easily apply to cast - resin dry - type transformers. The PD detection system consists of a capacitive probe and a low noise amplifier having the frequency bandwidth of 500 $Hz{\sim}30$ MHz. In the experimental set-up, sensitivity of the system is 7.16 mV/pC.

몰드변압기에서 부분방전 검출방법의 비교분석 (Comparison Analysis of Partial Discharge Detection Methods in Cast Resin Dry Type Transformers)

  • 박찬용;김성욱;최재성;박대원;길경석
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 추계학술대회 논문집
    • /
    • pp.301-306
    • /
    • 2008
  • Various sensors such as capacitive probe, high frequency current transformer (HFCT), and acoustic emission (AE) probe were applied to a cast resin dry type transformer for partial discharge detection. We designed and fabricated a wideband low-noise amplifier having a gain of 40[dB]. From the experiment which was carried out in the same transformer, the sensitivities were 7.16[mV/pC] for capacitive probe, 3.8[mV/pC] for HFCT, and 17.9[mV/pC] for AE probe.

  • PDF

몰드형 건식 계기용 변압기 진동 특성 분석 (Analysis of Vibration Characteristics for a Molded Dry-type Potential Transformer)

  • 김무선;장동욱;김승모
    • 한국산학기술학회논문지
    • /
    • 제18권3호
    • /
    • pp.209-214
    • /
    • 2017
  • 현재 철도 차량에 쓰이고 있는 대부분의 계기용 변압기는 장치 내부에 절연유가 충진되어 있는 유입식 계기용 변압기 방식으로서, 내구 연한 도래와 더불어 차량 운행 중 내부 압력 상승에 의해 폭발의 위험성이 있다. 이에 대한 해결책으로 절연 수지를 사용하여 방압 기능이 탁월한 몰드형 건식 계기용 변압기 개발이 필요하다. 이에 제품의 국산화가 가능하도록 한국철도기술연구원에서는 몰드형 건식 계기용 변압기를 개발 진행 중에 있다. 그 연구의 일환으로 개발 제품의 진동 특성 분석과 함께, 진동 환경하에서 변압기의 성능 유지 여부를 확인하여야 한다. 이번 연구에서는 철도 차량 부품의 진동 시험 방법 규격인 KS R 9144 및 IEC 61373 에 따라서 개발 제품의 공진시험과 모의 장기 수명 시험을 진행하였다. 고유 진동수는 해석을 통한 모달 분석과 공진 시험을 병행하여 결과를 비교 분석하였으며 규격 조건을 만족함을 확인하였다. 또한 모의 장기 수명 시험 후 성능 시험을 통해 오랜 시간 진동 환경 하에서도 개발 변압기의 기능에 문제가 없음을 확인하였다.

건식변압기 코일의 열적 수명평가 (Thermal Lifetime Estimation of Coil Used for Dry-type Transformer)

  • 김민규;허대행;김익수;장진영;문병철;고재철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 Techno-Fair 및 합동춘계학술대회 논문집 전기물성,응용부문
    • /
    • pp.131-132
    • /
    • 2008
  • This paper describes a method to estimate the thermal lifetime of coil used in the dry-type molded transformer which is widely used in the domestic distribution system. In order to reduce the testing time, temperature accelerated aging test is planned. Finally, the thermal lifetime estimation method is composed of a temperature aging test and a cyclic test of temperature, humidly and lightning impulse voltage withstand test.

  • PDF

345kV 변전소 주변압기 3차측용 건식형 분로리액터 개발 (The Development of Dry-type Shunt Reactor for 345kV Substation Main Transformer)

  • 안용호;박종범;송택상;한병성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.497-500
    • /
    • 2001
  • Shunt reactors are used to compensate for capacitive VARs generated by lightly loaded transmission lines or underground cables. They are normally connected to the transformer tertiary winding. Dry-type shunt reactors have the advantage compared with oil-immersed shunt reactor as followings. Lower investment and maintenance cost, No fire hazard and no environmental concerns, Simple insulation to ground, Response to transient overvoltage less severe, Linearity of inductance versus load current, Lower-acoustic noise, Easier transport and handling due to lower weight, No oil-collecting system must be provided since there is no oil that can leak into the ground.

  • PDF

50[kVA] 몰드변압기 권선부의 열전달 특성 해석 (Analysis on Thermal Transfer Characteristics of 50 kVA Mold-Transformer)

  • 이현진;정중일;허창수;조한구
    • 조명전기설비학회논문지
    • /
    • 제16권3호
    • /
    • pp.47-54
    • /
    • 2002
  • 본 논문은 단상 50[kVA] 몰드변압기 권선부의 열전달 특성에 대한 연구 결과이다. 1차 권선의 열전도도는 권선을 이루고 있는 물질 비 즉, 1차 권선의 절연을 담당하는 다량의 에폭시 수지와 그에 비해 소량의 구리 도선을 고려하여 결정하였다. 반면에 2차 권선의 경우 구성 성분은 다량의 구리도선과 절연을 담당하는 소량의 에폭시 수지로 되어 있다. 2차 권선 열전도도는 질량 비로서 결정될 수 없기 때문에 2차 권선의 열전도도값은 시작품의 측정 최고온도와 FEM을 이용한 분석결과를 비교하여 결정하였다. 각 권선부의 물리적 특징을 고려하여 상용 프로그램을 통해 시뮬레이션 모델을 만들었다. 본 연구결과를 바탕으로 몰드변압기 권선부에 Hole이 존재할 때와 안할 때 각각에 대해 주위온도·풍속변화에 따른 최고온도 변화를 고찰하였다.

3차원 그래픽을 이용한 전력용 변압기 유지보수 프로그램 개발 (Development of 3D Power Transformer Maintenance Application)

  • 이일화;박창현;장길수;조경래
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.114-116
    • /
    • 2005
  • This paper presents a maintenance application for power transformer. High quality maintenance and accurate diagnosis are essential for all transformers, especially for older ones. The developed application provides maintenance guides for dry type transformer and oil-filled transformer to prevent any malfunctions and to lengthen the lifetime of transformers. Based on windows application, TTS (text to speech) and 3D graphics technologies have been used to enhance the user friendly interface. Developed application is helpful for both expert and novice operators at substation.

  • PDF

에폭시수지로 몰딩된 권선의 열전달 특성 연구 (Analysis of Heat-transfer on Winding composed with Epoxy-resin)

  • 이현진;허창수;조한구;이기택;서유진
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집
    • /
    • pp.402-405
    • /
    • 2002
  • This paper presented the characteristic of Heat-transfer on the winding composed with Epoxy-resin in a 50 kVA cast-resin dry type transformer The resin cast transformer is used widely in supplying electricity systems. However, to know the thermal characteristics of that is very useful in designing, manufacturing, and maintaining, there is no pertinent method to calculate this. In this paper, Based on the results of the physical characteristics and the simulation by commercial software using FEM method, we established the Prototype Model for this. According to that Model, an analysis on a variation of the hottest spot temperature was discussed as a function of thermal conductivity for the individual windings composed with Epoxy-resin. The thermal conductivity of the individual windings with reference to upper way was discussed.

  • PDF