• Title/Summary/Keyword: Dry-air

Search Result 1,461, Processing Time 0.04 seconds

Thermal Performance of a Finned-tube Heat Exchanger used in Condensing Gas Boiler

  • Kang, Hie-Chan;Lim, Bok-Bin;Lee, Jung-Man;Kim, Moo-Han
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.17 no.2
    • /
    • pp.61-67
    • /
    • 2009
  • In the present study, an experiment was conducted to investigate the heat and mass transfer performance of heat exchangers used in the condensing gas boiler. Two types of spiral circular fin-tube heat exchangers and a plain tube were tested in the flue gas of propane and dry air. Heat and mass transfer coefficients were measured and compared with the previous correlations. The experimental data for the sensible heat transfer of the plain tube reasonably agreed with the previous correlations for dry air and flue gas. However, the mass transfer coefficient of the plain tube was greater than the previous correlations. The pH, $NO_x$, and $SO_x$ data of condensate were provided.

A study on indoor environmental elements of the granite model dome in different envelope materials during summer season (하절기, 석재 모형돔의 외피 유형별 실내환경 요소에 관한 연구)

  • 공성훈
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.6
    • /
    • pp.898-902
    • /
    • 1999
  • During summer season, the weather condition of Korea is hot and humid. So humidity elements are very important relating to building envelope condition. The purpose of this investigation is to measure and analyze characteristics of summer's environmental elements such as relative humidity, dry bulb temperature and air velocity in the clay/cement envelope materials using a granite dome model. According to the variation of exterior humidity, the state of interior relative humidity for clay model has an equal tendency, although a little range of variation is shown in comparison to the cement model.

  • PDF

Status Analysis for the Confinement Monitoring Technology of PWR Spent Nuclear Fuel Dry Storage System (경수로 사용후핵연료 건식저장시스템의 격납감시 기술현황 분석)

  • Baeg, Chang-Yeal;Cho, Chun-Hyung
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.14 no.1
    • /
    • pp.35-44
    • /
    • 2016
  • Leading national R&D project to design a PWR spent nuclear fuel interim dry storage system that has been under development since mid-2009, which consists of a dual purpose metal cask and concrete storage cask. To ensure the safe operation of dry storage systems in foreign countries, major confinement monitoring techniques currently consist of pressure and temperature measurement. In the case of a dual purpose metal cask, a pressure sensor is installed in the interspace of bolted double lid(primary and secondary lid) in order to measure pressure. A concrete storage cask is a canister based system made of double/redundant welded lid to ensure confinement integrity. For this reason, confinement monitoring method is real time temperature measurement by thermocouple placed in the air flow(air intake and exit) of the concrete structure(over pack and module). The use of various monitoring technologies and operating experiences for the interim dry storage system over the last decades in foreign countries were analyzed. On the basis of the analysis above, development of the confinement monitoring technology that can be used optimally in our system will be available in the near future.

Prediction of Yield from Leaf weight and Leaf area (건엽중 및 엽면적에 의한 잎담배 수량예측)

  • 이철환;이병철
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.11 no.2
    • /
    • pp.115-126
    • /
    • 1989
  • This study was conducted to determine the time and methods of predicting tobacco yield, by studying the relationship of yield components to yield. 1. The relationship between each position in leaf dry weight and approached gradually each other and also correlation coefficient of top leaf was higher than that of lower leaf. The leaf dry weight per plant was highly correlated with leaf area from 16th leaf position on stalk. Leaf dry weight of each leaf position on stalk was highly correlated with leaf dry weight per plant at 14 to 16th leaf position. 2. The correlation coefficient between leaf dry weight and leaf area per plant was higher at the late growth stage than at the early growth stage, and higher between the near stages. Correlation coefficient between leaf dry weights was higher than that of leaf areas. 3. Flue-cured tobacco yield be estimated from leaf dry weight per plant at 50 to 55 days after transplanting. 4. Air-cured tobacco yield could be predicted from leaf dry weight per plant at 60 days after transplanting.

  • PDF

Development of Low Pollution Grinding Technology using Mist (Mist를 이용한 저공해 연삭 가공기술 개발)

  • 최헌종;이석우;김대중;정해도
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.793-797
    • /
    • 2000
  • The environmental problems by using coolant demanded the new cooling methods. As one of them the studies on the dry grinding with compressed cold air have been done. The cooling method using compressed cold air was effdve thmugh going down the temperature of compressed air supplied below $-25^{\circ}C$ and inneasing the amount of mmpresd cold air, but had not enough cooling effect due to the low performance of lubrication. Therefore, the cooling methods using MQL(Minimum Quantity Lubrication) or mist newly were suggested. These two methods can satisfy both cooling effect and lubrication with only small amount of coolant, also has the benefit in the point of decreasing the envimnmental pollution. This paper focused on analyzing the grindmg characteristics of the cooling method using mid. The generated heat and grinding force of the cooling method using mist were compared with them of coolant and compressed cold air. And them grinding test according to the temperature of compressed cold air, mist spray amount and mist supply direction were done.

  • PDF

Study of the Moderately Under-Expanded Supersonic Jet of Moist Air (부족팽창된 습공기 초음속 제트에 관한 연구)

  • Baek, Seung-Cheol;Kim, Heuy-Dong;Kwon, Soon-Bum
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.2121-2126
    • /
    • 2003
  • Supersonic free jets discharging from an orifice or a nozzle have long been research subject with a number of engineering applications and have mainly been investigated using dry air or other gas without any condensation effects. The major characteristics of those supersonic jets are now well known in terms of jet pressure ratio and ratio of specific heats of gas. Recently, the supersonic jets of superheated steam or moist air are being used in many industrial applications, in which case is expected that the condensation effects might alter the fundamental structure of the dry air jet. The present study aims to investigate the supersonic moist air jet and to clarify the condensation effects on the jet structure. An experiment is carried out using an indraft wind tunnel facility. The relative humidity of moist air is controlled at the nozzle supply, and the jet pressure ratio is varied to obtain the moderately under expanded flows at the exit of the nozzle. It is found that the relative humidity of moist air can change the diameter and location of Mach Disk.

  • PDF

An Experimental Study on the Cooling Tower of Plume Prevention and Performance Improvements (냉각탑 백연방지의 성능 향상에 관한 실험적 연구)

  • JEONG, SOON YOUNG;LEE, BYEONG CHEON;KIM, SUNG
    • Journal of Hydrogen and New Energy
    • /
    • v.30 no.6
    • /
    • pp.578-584
    • /
    • 2019
  • The occurrence of white plume in the cooling tower is phenomenon that the steam in the air through the cooling tower fan is condensed again by the cold ambient air to become saturated moist air. Accordingly, this can cause many problems like spoiling landscape around the cooling tower, odor of ambient air, falling accident by frozenness in the winter, and traffic accident, etc. This study was to install the heat exchanger in the inside of the cooling tower in order to prevent the white plume phenomenon in the cooling tower without affecting the performance of cooling tower. In addition, this study was to discharge the part of cooling water into the atmosphere through the recirculation of heat exchanger after creating dry air by heating the saturated moist air to the dew point temperature. At that time, this study was to conduct the experimental study in order to secure the optimal design data to prevent the white plume in the cooling tower because it checked the dry·moist temperature and relative humidity in the inside·outside of cooling tower on the moist air, and evaluated the performance of the heat exchanger.

Analysis of the Thermal Environment in the Laying House (산란계사내부 열환경 분석)

  • Kim Y. B.;Lee S. K.;Kim S. T.;La W. J.;Chang H. H.
    • Journal of Animal Environmental Science
    • /
    • v.11 no.3
    • /
    • pp.177-188
    • /
    • 2005
  • In this study, the thermal environmental factors in a layer f(arm such as dry bulb temperature, relative humidity, black globe temperature and illumination intensity were measured and analyzed to serve as basis for effective design and plan of poultry houses. The correlation analysis between the different factors was also done. Heat Index as measure of the thermal stress was also calculated and analyzed. A $1,000m^2$ laying house, 4 meters high with 52,000 layers in six-stage type cages was used in the measurement of the different environmental parameters. The results were as follows; 1. The temperature of the inside air and materials was directly related to the increase in aerial temperature based on the dry-bulb, black globe temperature reading. The correlation factor of the outside to inside air based on dry bulb setting was very significant at 0.927 The dry bulb temperature for inside temperature ranged from $19.9\~28.8^{\circ}C\;with\;SD+2.2^{\circ}C$ while that of the outside air was $16.2\~33.1^{\circ}C,\;SD+3.5^{\circ}C$. In addition, the temperature of the inside air was very stable. 2. The black globe temperature of the inside air ranged from $20.1\~28.8^{\circ}C,\;SD+2.3^{\circ}C$ while that of the outside air was $16.2\~47.5^{\circ}C,\;SD+6.0^{\circ}C$. 3. The relative humidity of the outside and inside air was $72.4\~100\;and\;50.2\~85.6\%$ with an average of $89.2\;and\;71.7\%$, respectively. 4. The illumination intensity in the laying house was less than 7 lux, with an average of $1.2\~2.5lux$ relative to height indicating that the laying house was well isolated from outside radiation. 5. The heat index of the inside air of the laying house had a high variation from $20.5^{\circ}C,\;SD+2.5^{\circ}C$ while that of the outside air was $13.1\~45.5^{\circ}C$, with an average of $21.6^{\circ}C,\;SD+6.3^{\circ}C$.

  • PDF

Impulse Breakdown Behaviors of Dry Air as an Alternative Insulation Gas for SF6

  • Li, Feng;Yoo, Yang-Woo;Kim, Dong-Kyu;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.3
    • /
    • pp.24-32
    • /
    • 2011
  • [ $SF_6$ ]gas, which has an excellent dielectric strength and interruption performance, is used in various applications such as gas insulated switchgear (GIS) in substations. However, since $SF_6$ has a high global warming potential (GWP), it is necessary to find an eco-friendly alternative insulation gas. In order to examine the possibility of using alternative insulation gases for $SF_6$ in power distribution system equipment, the dielectric strength and physical phenomena of dry air in a quasi-uniform electric field are investigated experimentally in this paper. As a result, the breakdown voltages for positive polarity are higher than those for negative polarity under impulse voltage applications. The negative 50[%] flashover voltage, $V_{50}$ of dry air under conditions above 0.4[MPa] gas pressure, is higher than 150[kV], that is the basic impulse insulation level of distribution equipment. The $V_{50}$ increases linearly with increasing the gas pressure, regardless of the waveform and polarity of the applied impulse voltages. The voltage-time curves are dependent on the rise time of the impulse voltage and gas pressure. Furthermore, streamer discharge was observed through light emission images by an ICCD camera under impulse voltage applications.

VOC Emission Characteristics of Dry Cleaned Wool Scarfs through Small Chamber Test (소형챔버를 이용한 드라이클리닝 모직물 목도리의 휘발성유기화합물 방출 특성)

  • Shin, Jin-ho;Kwon, Seung-mi;Kim, Hyun-soo;Roh, Bang-Sik;Kim, Kwang-rae;Eo, Soo-mi;Jung, Kweon;Lee, Young-Kyu
    • Journal of Environmental Health Sciences
    • /
    • v.43 no.2
    • /
    • pp.95-102
    • /
    • 2017
  • Objectives: This study was conducted to evaluate the emission of VOCs from clothing that had been dry cleaned. Methods: In order to ensure the same conditions, f100% wool scarves were selected as the fabric type. Four identical tests were conducted on the option of either removing the plastic bags which came from the dry cleaning shop or not. The scarf was located inside a closet or room for one or two days. Small chamber tests were conducted to determine the VOC emission characteristics under the same conditions such as temperature, humidity, loading factor, and air exchange rates. Air from the chamber for VOCs was sampled by Tenax TA tube and analyzed by thermal desorption and GC/MSD. Results: Assuming that test represented dry cleaning and consumer's conditions well enough, we can conclude that immediate emissions after the dry cleaning of the scarfs caused elevated levels of TVOC, five VOCs (benzene, toluene, ethylbenzene, xylene, stylene), and decane group compounds. Conclusions: By removing the plastic bags which came from the dry cleaning shop or not, the storage conditions of dry cleaned scarfs by consumers during the storage time periods (one to three days) would be significant for reducing VOC emissions.