• 제목/요약/키워드: Dry room system

검색결과 45건 처리시간 0.024초

강화폴리에스테르튜브(XL 튜브)에 진동형 히트 파이프를 결합한 고성능 난방 패널의 성능에 관한 연구 (A Study on the highly efficient ondol system combined the strengthen polyethylene pipe with pulsating heat pipe)

  • 김창희;김종수;우재호;공상운
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.578-583
    • /
    • 2008
  • Korea which has change of clear season is using unique heater by the name of On-dol being invented since ancient times. Floor-heating device has no radiator, and generates no noise and dust. It can obtain satisfied heating sense than other heating system in low room temperature. And also it is a pleasant system that equals bottom and top temperature in a room. The purpose of this study is to develop the Floor-heating device using pulsating heat pipe. It propose floor-heating device using pulsating heat pipe of the dry process which alternative polyethylene pipe(low XL pipe) that is used widely to existent floor heating system and produce pilot Experiment and analyzed operation condition and performance of most suitable. In this study, main purpose is to develop floor-heating system using pulsating heat pipe by finding an optimum working condition according to changing ratio and evaluating a performance.

  • PDF

유리 섬유 강화 폴리우레탄 폼의 온도 및 변형률 속도 의존 재료 거동 모델링 (Modeling of the Temperature-Dependent and Strain Rate-Dependent Dynamic Behavior of Glass Fiber-Reinforced Polyurethane Foams)

  • 이동주;신상범;김명현
    • 한국해양공학회지
    • /
    • 제33권6호
    • /
    • pp.547-555
    • /
    • 2019
  • The purpose of this study was to establish a numerical model of polyurethane foam (PUF) to simulate the dynamic response and strength of membrane-type Liquefied natural gas (LNG) Cargo containment system (CCS) under the impact load. To do this, initially, the visco-plastic behavior of PUF was characterized by testing the response of the PUF to the impact loads with various strain rates as well as PUF densities at room temperature and at cryogenic conditions. A PUF material model was established using the test results of the material and the FE analysis. To verify the validation of the established material model, simulations were performed for experimental applications, e.g., the dry drop test, and the results of FEA were compared to the experimental results. Based on this comparison, it was found that the dynamic response of PUF in dry drop tests, such as the reaction force and fracture behaviors, could be simulated successfully by the material model proposed in this study.

호주인과 호주 교민의 주거문화 비교를 위한 기초 연구(I) -호주 교민의 주생활 분석을 중심으로 - (A Baseline Study on Housing Cultures for Cross-Cultural Comparison between Korean- Australians and Australians(I) : An Analysis of Housing Cultures of Korean- Australian Families.)

  • 이영심;이상해
    • 가정과삶의질연구
    • /
    • 제23권2호
    • /
    • pp.107-125
    • /
    • 2005
  • Each ethnic group has a different cultural background and has developed its own culture in the name of a tradition. The interaction between different cultures is ever increasing through the process of acculturation or culture contact The purpose of this study is to provide baseline information about domestic living of Korean immigrants in Australia and Australians for a larger cross-cultural study project. As the first step, the usage of domestic space and seating styles of 52 Korean households in Melbourne were analyzed. Ethnographic research was conducted, utilizing a questionnaire. The findings of this research are as follows: 1. The most popular type of Living-Dining-Kitchen arrangement was the one which the kitchen is separated from the living and dining area. The level of satisfaction was the highest when the living room, dining room, and kitchen were all separated. 2. A laundry room was indispensable for Koreans in Australia, and they wanted to dry laundry and do ironing in there. Most people were satisfied with the toilet separated from the bathroom A drain hole on the floor of the bathroom was not indispensable for most Korean-Australians. 3. Korean-Australians tend to engage in various activities in their individual rooms, and they estimated that the size of most rooms were small. They also wanted to renovate the house to expand the rooms. 4. The seating style of Korean-Australians was mostly chair-seating. Yet, they often made beds on the floor for guests, and made kimchi sitting on the floor. Also, when they were relaxing, they were using both chair-seating and floor-seating. 5. Korean-Australians were not very satisfied with the use of floor carpets because of the dust collected on the carpets, and the difficulty to clean. It may be related to their preferred floor seating style, as well. 6. Almost all Korean-Australians take off their shoes inside of the house for hygienic reasons. They had a shoes cabinet at the entrance inside of the house. 7. The most popular heating system was ducted heating. The level of satisfaction about this was moderate because hot air contains lots of dust and it makes rooms very dry. Many were using electric blankets and their desired heating system was Ondol (heated floor). 8. Korean-Australians thought that the living room was the most important place for the family, and believed it should be decorated well to entertain guests. They also pointed out that the lighting was not bright enough in general.

가혹 환경이 복합재/Ni-Cr 합금 접착전단강도에 미치는 영향 연구 (Effect of Adhesive Shear Strength of CFRP/Ni-Cr Alloy Under Severe Environmental Condition)

  • 조현태;박성민;김민준;황반토;김학인;손명숙;안종기;안지민;최진호;남영우;권진회
    • Composites Research
    • /
    • 제33권5호
    • /
    • pp.275-281
    • /
    • 2020
  • 본 논문에서는 항공기 팬 블레이드에 적용되는 복합재와 금속 간의 접합 구조물에 대한 온도, 습도에 따른 접착제의 물성 변화에 관해 연구하였다. 항공기 운용 시 노출되는 환경 조건을 고려하여 상온 건조(Room Temperature Dry, RTD), 고온 흡습(Evaluated Temperature Wet, ETW), 저온 건조(Cold Temperature Dry, CTD) 세가지 환경에서 강도 시험을 수행하였다. 접착전단강도 시험은 ASTM D3528을 기준으로 수행하였고, 파손 영역에 대한 마이크로 구조 특성을 SEM이미지를 통해 분석하였다. 연구 결과에 따르면 RTD 환경에서의 전단강도 대비하여 ETW 환경에서 72.8% 저하되었으며, CTD 환경에서는 56.5% 증가되었다. 이는 고온 및 수분 흡습이 접착제의 기계적 특성에 큰 영향을 미치는 것을 확인했고, 저온 환경에서는 모재와 접착제 모두 취성의 증가로 인해 접착 전단 강도가 향상된 것으로 분석되었다.

항온항습 환경에서 울릉도 시추코어의 건조·수포화 열전도도 (Thermal Conductivity of Dry and Saturated Cores from Ulleung Island in a Constant Temperature and Humidity Condition)

  • 이근수;이상규;이태종
    • 지구물리와물리탐사
    • /
    • 제21권4호
    • /
    • pp.220-230
    • /
    • 2018
  • 상온 환경에서 PEDB (Portable Electronic Divided Bar) 시스템을 이용하여 암석의 열전도도를 측정할 경우 실내온도 변화에 영향을 받는다. 따라서 온도와 습도를 일정하게 조절할 수 있는 항온항습기 내에서 열전도도를 측정하면 상온 환경에서 측정할 때의 단점을 보완할 수 있다. 이 연구에서는 항온항습 상태에서 열전도도를 측정할 수 있는 시스템을 구축하여, 울릉도의 GH3, GH4 시추공에서 채취된 45개 시편에 대해 항온항습기 내에서 건조 및 수포화 열전도도를 측정하고 그 특성을 살펴보았다. 또한, 16개 시편에 대해 밀도 및 유효공극률을 측정하여 열전도도와의 상관관계를 분석하였다. 열전도도와 유효공극률 및 밀도의 상관성 분석결과, 수포화 시료보다는 건조시료에서 보다 높은 상관성을 보였으며, 특히 "수포화/건조 열전도도비"는 유효공극률과 매우 높은 상관성($R^2=0.90$)을 보였다.

압출된 OFHC Cu 봉재의 집합조직과 마멸거동 (The effect of texture of an extruded OFHC Cu rod on its sliding wear characteristics)

  • 이슬기;김용석;조재형
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2009년도 추계학술대회 논문집
    • /
    • pp.354-357
    • /
    • 2009
  • The effect of texture of an extruded OFHC Cu rod on its sliding wear has been explored. Disk specimens with three different orientations were machined from the Cu rod for the wear test; surfaces of the disk were perpendicular ($0^{\circ}$), inclined with a specific angle ($45^{\circ}$), and parallel ($90^{\circ}$) to the extrusion axis of the rod. The texture was analyzed using an X-ray goniometer by measuring {111}, {200}, and {220} pole figures of each specimen. The analyzed texture was correlated with wear-test results of the Cu specimen. Dry sliding wear tests were performed at room temperature using a pin-on-disk wear tester against an Al2O3 ball. Applied load, sliding distance, sliding speed were fixed as 20 N, 200 m, and 0.5 m/sec, respectively. The $45^{\circ}$-inclined (to the extrusion axis) disk specimen showed the lowest wear resistance with the least data scatters. It has been found that distribution of cube texture strongly influences wear rate of the extruded Cu rod.

  • PDF

입방정계 순 금속 Fe, Cu의 미끄럼 마멸 거동 (Sliding Wear Behavior of Pure Metal, Fe and Cu Having a Cubic Crystal System)

  • 이슬기;김용석
    • 소성∙가공
    • /
    • 제19권6호
    • /
    • pp.357-362
    • /
    • 2010
  • Dry sliding wear behavior of pure Fe and Cu which have BCC and FCC crystal structure, respectively, was investigated. The wear characteristics of the pure metals with different crystal structure were compared. Dry sliding wear tests were carried out using a pin-on-disk wear tester at various loads under the constant sliding speed condition of 0.15 m/s against a silica ball at room temperature. Sliding distance was fixed as 600 m for all wear tests. Wear rate of a specimen was calculated by dividing the weight loss of the specimen after the test by the specific gravity and sliding distance. Worn surfaces and wear debris were analyzed by SEM. The wear of both pure Fe and Cu proceeded with surface deformation, resulting in similar wear rates despite of their structure difference under the current test conditions. Wear rates of both metals were low if the surface deformation due to wear forms thick surface-deformation layer that is strain hardened beneath the wearing surface. The pure Cu specimens showed a lot of oxides on the worn surface when tested at low loads less than 5 N, which resulted in very low wear rate.

High-temperature ultrasonic thickness monitoring for pipe thinning in a flow-accelerated corrosion proof test facility

  • Cheong, Yong-Moo;Kim, Kyung-Mo;Kim, Dong-Jin
    • Nuclear Engineering and Technology
    • /
    • 제49권7호
    • /
    • pp.1463-1471
    • /
    • 2017
  • In order to monitor the pipe thinning caused by flow-accelerated corrosion (FAC) that occurs in coolant piping systems, a shear horizontal ultrasonic pitch-catch waveguide technique was developed for accurate pipe wall thickness monitoring. A clamping device for dry coupling contact between the end of the waveguide and pipe surface was designed and fabricated. A computer program for multi-channel on-line monitoring of the pipe thickness at high temperature was also developed. Both a four-channel buffer rod pulse-echo type and a shear horizontal ultrasonic waveguide type for high-temperature thickness monitoring system were successfully installed to the test section of the FAC proof test facility. The overall measurement error can be estimated as ${\pm}10{\mu}m$ during a cycle from room temperature to $200^{\circ}C$.

소구경 미세홈 고속가공시 가공환경변화에 따른 가공성 평가 (Evaluation of Machinability of Micro groove by Cutting Environments in High Speed Machining using Ball End Mill)

  • 정연행;이태문;강명창;이득우;김정석
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2002년도 춘계학술대회 논문집
    • /
    • pp.32-37
    • /
    • 2002
  • High speed machining is one of most effective technologies to improve productivity. It can give great advantage for manufacture of die and Moulds. However, when the high speed machining of materials, especially in machining of micro groove, a severely thermal demage was generated on workpiece and tool. Generally, the cutting fluid is used to improve penetration, lubrication, and cooling effect. In order to rise the performance of lubrication, it contains extreme pressure agents (Cl, S, P). But the environment of work room go bad by those additive Therefore, the compressed chilly air with Oil mist system was developed to replace the conventional cutting fluid system. This paper carried out the tests to evaluate the machinability by the cutting environment in high speed micro groove machining of NAK80 (HRC40). Compressed chilly air with oil mist was ejected on the contact area between cutting edge and workpiece. The effectiveness of this developed compressed chilly air with oil mist system was evaluated in terms of tool life. The results showed that the tool life of carbide tool coated TiAIN with compressed chilly air mist cooling was much longer than with dry and flood coolant when cutting the material.

  • PDF

미세홈 고속가공시 절삭유제 공급방식에 따른 가공성 평가 (Cutting Characteristics of Micro grooving by Cutting Environments in High Speed Machining using Ball End Mill)

  • 배정철;정연행;강명창;이득우;김정석
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 추계학술대회 논문집
    • /
    • pp.172-175
    • /
    • 2002
  • High speed machining is one of the most effective technologies to improve productivity. It can give great advantage for manufacture of die and Moulds. However, when machining of micro groove in high speed machining a severely thermal damage was generated on workpiece and cutting tool. Generally, the cutting fluid is used to improve penetration. lubrication. and cooling effect. In order to rise the performance of lubrication. it contains extreme pressure agents (Cl, S, P). But the environment of work room go bad by those additive. Therefore, the compressed chilly air with oil mist system was developed to replace the conventional cutting fluid system. This paper carried out the tests to evaluate the machinability by the cutting environment in high speed micro groove machining of NAK80 (HrC40). Compressed chilly air with oil mist was ejected on the contact area between cutting edge and workpiece. The effect of this developed compressed chilly air with oil mist system was evaluated in terms of tool life. The results showed that the tool lift of carbide tool coated TiAlN with compressed chilly air mist cooling was much longer than that of the dry and flood coolant when cutting the material.

  • PDF