• Title/Summary/Keyword: Dry System

Search Result 2,157, Processing Time 0.039 seconds

A Experimental Study for Developing of the Dry Double Floors Hydronic Ondol System (건식이중바닥온돌시스템 개발을 위한 실험적 연구)

  • Kim Nan-Haeng;Sohn Jang-Yeul
    • Journal of the Korean housing association
    • /
    • v.17 no.3
    • /
    • pp.1-7
    • /
    • 2006
  • The aim of the research was to evaluate the characteristics of thermal environment and thermal comfort in the Dry Double floors Hydronic Ondol System. Physical indoor thermal environments (the floor surface temperature, the vertical temperature, etc.) and skin temperature have especially been measured. Physical features conditions, sensation, thermal comfort, humidity sensation, comfort of body were investigated for the survey. As a result, (1) During the operation of the boiler (12 hour), the average indoor temperature is appeared to be $21.6^{\circ}C$. The floor surface temperature showed peak value of $31.4{\sim}40.6^{\circ}C$ after 8hours 30minutes after the start-point of the heating. The vertical difference of temperature was turned out to be not uniform. (2) While the skin temperature showed a narrow distribution of temperature in the Dry Double floors Hydronic Ondol system. (3) The response to thermal comfort which people felt was satisfactory, and most of them felt dry during the test.

The Evaluation for Quality Characteristics of Drying Flowering Plant by Vacuum-Freeze (진공 동결에 의한 건조 화훼류의 품질특성 평가에 관한 연구)

  • Kim, J.D.
    • Journal of Power System Engineering
    • /
    • v.15 no.4
    • /
    • pp.5-10
    • /
    • 2011
  • In case of using rapid vacuum-freeze drying for high quality dry flower of flowering plant, the morphological and physiological characteristics of dry rose showed as the following. The dry ratio of about 82% presented after 1 day in case of using rapid vacuum-freeze drying and it was reached that the optimum storage water content of general dry products was 18%. The dry ratio of about 89% presented after 4 days. This result indicates very short dry time comparing with natural dry time of 12 days. Also, the morphological characteristics of flowering plant in case of vacuum-freeze drying showed similar shape with real flower. The contraction decreased about 9% comparing with real flower under dry time of 72 hours. But the contraction in case of natural dry decreased 36% and showed noticeable difference. The brightness which affects physiological characteristics of dry flowering plant showed lower values according to the dry process and chromaticity was thick. After 4 days, natural dry was thick with about 2 times comparing with vacuum-freeze drying. In case of vacuum-freeze drying, the quantity of anthocyanin and chlorophyl which affect discoloration and bleaching of dry flowering plant showed the clear difference comparing with natural dry method due to the sublimation by vacuum after rapid freeze with short initial time.

Development and Analysis of Dry Forming System for Innovation of Papermaking Technology

  • Kim, Jong-Min;Lee, Hak-Lae;Youn, Hye-Jung;Hwang, Min-Gu
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 2006.06b
    • /
    • pp.181-190
    • /
    • 2006
  • This study was conducted to develop dry forming technology and evaluate the properties of dry formed paper made from Hw-BKP. A dry forming mold (DFM) was developed to observe the phenomena of dry forming and evaluate the properties of formed papers. To upgrade the DFM a dry forming system (DFS) was developed. This DFS was designed to improve the formation of dry formed papers and enhance the productivity of dry forming. Dry forming gave papers with greater bulk and opacity than wet forming. Tensile strength of dry formed paper was greater than that of conventional wet formed handsheet when they were made from the same dry disintegrated fibers. But tensile strength of conventional wet formed handsheet made from beaten fiber was much greater than that of dry formed paper made from dry disintegrated fibers. When solvent dried beaten fibers were used in dry forming, the tensile strength of dry formed papers reached 73.5% of the wet formed handsheets made from beaten fiber. It showed that dry forming has a significant potential in improving strength properties when proper preparation of fibers and appropriate humidification, pressing, and drying processes are employed.

  • PDF

Development of the Novel Dry and Wet Deposition Collector (새로운 건성 및 습성 침착 채취기의 개발)

  • 이병규;이채복
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.6
    • /
    • pp.675-684
    • /
    • 2000
  • A novel dry and wet deposition collector, which can overcome the several problems such as water evaporation cartridge cracks and high costs founded in the previous collector systems, has been constructed. ENVI-18 SPE adsorption cartridge has been used to measure atmospheric deposition of polycylic aromatic hydrocarbons (PAHs). A surrogate surface, consisted of water and methanol, was filled in the dry deposition funnel to simulate dry deposition onto water surface. A water supply system in order to compensat evaporation of the surrogate surface was used and it was consisted of a piston pump, a tubing pump, a overflow tube and a chamber system. A novel water vaporizing system to supply water onto the wet SPE cartridge system with a constant flow rate was developed. The novel water vaporizing system, consisted of a vacuum pump, a water supply reserviour and tube and a mini space heater, could prevent the PAHs adsorption cartridge cracks occurred in the previous collector and effectively adsorb PAHs. The novel dry and wet deposition collector showed a good adsorption, desorption, and recovery rates of PAHs. By reducing the number of pumps used and employing polypyopylene (PP) instead of teflon as a material of collection funnel, the total construction costs were much reduced as compared with the previous dry and wet deposition collectors.

  • PDF

A Development of the Grain Moisture Dry System Using Water-rate Compensator and PID Controller (함수율 보정기와 PID제어기를 이용한 곡물 수분 건조 시스템 개발)

  • Lee, Chang-Kuen;Shim, Woo-Chul;Park, Sung-Jin;Hong, Yeon-Chan
    • Proceedings of the KIEE Conference
    • /
    • 2001.11c
    • /
    • pp.315-318
    • /
    • 2001
  • In this paper recommends the development of automated silo dry & storage system. Most of existing round shaped iron silo arc used for only storage after dry and have many problems in storing. So We have developed an automated dry system which used the previously equipped silo and enables it to be used for storage after dry. The system features high frequency-resistance water sensor in Hopper scale that is in general use within the country its silo that is manufactured by the nerve DSP(TMS320C32) system water compensator and visualization that is finally realized with a personal computer.

  • PDF

Numerical modeling of seawater flow through the flooding system of dry ocks

  • Najafi-Jilani, A.;Naghavi, A.
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.1 no.2
    • /
    • pp.57-63
    • /
    • 2009
  • Numerical simulations have been carried out on the flooding system of a dry located at the south coasts of Iran. The main goals of seawater flow haracteristics in the intake channels conditions of the flooding system are imposed in the modeling. The upstream boundary condition is the tidal fluctuations of sea water level. At the downstream, the gradually rising water surface elevation in the dry described in a transient boundary condition. The numerical results are compared with available laboratory a good agreement is obtained. The seawater discharge through the flooding system and the required time to filling up the dry dock is determined at the worst case. The water current velocity and pressure on the rigid boundaries are discussed.

Development of a dry mock-up system for verifying pyroprocess automation

  • Seungnam Yu;Dongseok Ryu;Byugsuk Park;Jonghui Han
    • Nuclear Engineering and Technology
    • /
    • v.56 no.5
    • /
    • pp.1913-1924
    • /
    • 2024
  • This paper presents the design and operation of an autonomous robot for pyroprocess automation, which requires unique approaches beyond those used in industrial applications to achieve the desired performance. Maintaining an extremely dry atmosphere is crucial to handle various materials, including chloride, and an autonomous system ensures this dry environment. The drying room dehumidifier was carefully selected and designed to generate dry air, and different types of dry air conditioning performance were evaluated, including assessing worker accessibility inside the mock-up to determine the system's feasibility. Containers used for process materials were modified to fit the gripper system of the gantry robot for automation. The loading and unloading of process materials in each equipment were automatically performed to connect the process equipment with the robotic system. The gantry robot primarily operated through macro motion to approach waypoints containing process materials, eliminating the need for precise approach motion. The robot's tapered jaw design allowed it to grasp the target object even with imperfect positioning. Robot motions were programmed using a robot simulator for initial positioning and motion planning, and real accuracy was tested in a mock-up facility using the OPC platform.

Some Schemes for the sustainable Development of Korean Laver Industry (우리나라 김 산업 발전을 위한 논점과 방안)

  • Ock, Young-Soo
    • The Journal of Fisheries Business Administration
    • /
    • v.41 no.2
    • /
    • pp.25-44
    • /
    • 2010
  • The laver has been cultivated long time ago in Korea. And traditional production system was changed to new system about 30 years ago. The new production system is understood the specialization of laver products, that is, originally individual fishery households made final laver products from raw cultured laver in sea working to dry working in land, but the new system was separated raw laver production in sea and dry laver production, which made final dry laver products by purchase the raw laver in land. This change has been increased laver production, 10 billion sheets in 2000's from 5 billion sheets in 1980's. And rapid production increase gave rise to some troubles on laver industry that is a serious drop in real laver prices, discord structure between raw laver producer and dry laver producer, stagnation of laver consumption, etc. Now Korea is the best laver production country together with Japan in world. Then we have to consider some schemes for the sustainable development of laver industry. One of such schemes is export enlargement of laver against world. The consumption of laver has been globally increased in recent. The other is the grading test problem of dry laver. Because the rapid increase of laver production caused to drop laver quality. Then we seriously have to consider the grading test of dry laver for high level quality production.

A Study on the Dry-Shrinkage Properties For Floor Mortar With Crack-Reducing (균열저감형 바닥마감전용 모르터의 건조수축특성 연구)

  • 이종렬;이웅종;채재홍;박경상;김기수
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.04a
    • /
    • pp.175-180
    • /
    • 1999
  • The heating system of korea apartment house is called Ondol. The surface finishing mortar of this floor system typically used the cement based mortar, where the surface finishing mortar easily appears the crack. To order to crack control, the cement that added expansive additive used to reducing dry-shrinkage. For the surface finishing mortar, the types of shrinkage is known as plastic shrinkage, dry-shrinkage and autogenous This experimental study is to investigate the difference on dry-shrinkage of the cement that added expansive additives and OPC. The test method is varied the ration of water/cement (W/C) and the ratio of sand/cement(S/C). For OPC, The increase of the ratio of S/C is reduced dry-shirnkage but for the cement that added expansive additives, the increase of the ratio of S/C is augmented dry-shrinkage For OPC, The increase of the ratio of W/C is augmented dry-shrinkage but for the cement that added expensive, the increased of the ratio of W/C is reduced dry-shrinkage.

  • PDF