• 제목/요약/키워드: Dry Storage Canister

검색결과 23건 처리시간 0.023초

Design and Structural Safety Evaluation of Canister for Dry Storage System of PWR Spent Nuclear Fuels

  • Taehyung Na;Youngoh Lee;Taehyeon Kim;Donghee Lee
    • 방사성폐기물학회지
    • /
    • 제21권4호
    • /
    • pp.559-570
    • /
    • 2023
  • The aim of this study is to ensure the structural integrity of a canister to be used in a dry storage system currently being developed in Korea. Based on burnup and cooling periods, the canister is designed with 24 bundles of spent nuclear fuel stored inside it. It is a cylindrical structure with a height of 4,890 mm, an internal diameter of 1,708 mm, and an inner length of 4,590 mm. The canister lid is fixed with multiple seals and welds to maintain its confinement boundary to prevent the leakage of radioactive waste. The canister is evaluated under different loads that may be generated under normal, off-normal, and accident conditions, and combinations of these loads are compared against the allowable stress thresholds to assess its structural integrity in accordance with NUREG-2215. The evaluation result shows that the stress intensities applied on the canister under normal, off-normal, and accident conditions are below the allowable stress thresholds, thus confirming its structural integrity.

Realistic thermal analysis of the CANDU spent fuel dry storage canister

  • Tae Gang Lee;Taehyeon Kim;Taehyung Na;Byongjo Yun;Jae Jun Jeong
    • Nuclear Engineering and Technology
    • /
    • 제55권12호
    • /
    • pp.4597-4606
    • /
    • 2023
  • Thermal analysis of the CANDU spent fuel dry storage canister is very important to ensure the integrity of the spent fuel. The analyses have been conducted using a conservative approach, with a particular focus on the peak cladding temperature (PCT) of the fuel rods in the canister. In this study, we have performed a realistic thermal analysis using a computational fluid dynamics (CFD) code. The canister contains 9 fuel bundle baskets. A detailed analysis of even a single basket requires significant computational resources. To overcome this challenge, we replaced each basket with an equivalent heat conductor (EHC), of which effective thermal conductivity (ETC) is developed from the results of detailed CFD calculations of a fuel bundle basket. Then, we investigated the effects of some conservative models, ultimately aiming at a realistic analysis. The results revealed: (i) The influence of convective heat transfer in the basket cannot be ignored, but it's less significant than expected. (ii) Modeling of the lifting rod is crucial, as it plays a decisive role in axial heat transfer at the center of the canister and significantly reduces the PCT. (iii) Convection within the canister is very important, as it not only reduces the PCT but also shifts its location upwards.

Nondestructive inspection of spent nuclear fuel storage canisters using shear horizontal guided waves

  • Choi, Sungho;Cho, Hwanjeong;Lissenden, Cliff J.
    • Nuclear Engineering and Technology
    • /
    • 제50권6호
    • /
    • pp.890-898
    • /
    • 2018
  • Nondestructive inspection (NDI) is an integral part of structural integrity analyses of dry storage casks that house spent nuclear fuel. One significant concern for the structural integrity is stress corrosion cracking in the heat-affected zone of welds in the stainless steel canister that confines the spent fuel. In situ NDI methodology for detection of stress corrosion cracking is investigated, where the inspection uses a delivery robot because of the presence of the harsh environment and geometric constrains inside the cask protecting the canister. Shear horizontal (SH) guided waves that are sensitive to cracks oriented either perpendicular or parallel to the wave vector are used to locate welds and to detect cracks. SH waves are excited and received by electromagnetic acoustic transducers (EMATs) using noncontact ultrasonic transduction and pulse-echo mode. A laboratory-scale canister mock-up is fabricated and inspected using the proposed methodology to evaluate the ability of EMATs to excite and receive SH waves and to locate welds. The EMAT's capability to detect notches from various distances is evaluated on a plate containing 25%-through-thickness surface-breaking notches. Based on the results of the distances at which notch reflections are detectable, NDI coverage for spent nuclear fuel storage canisters is determined.

월성1호기 사용후 핵연료 건식저장 캐니스터의 열적 안전성에 미치는 대기 조건 인자의 영향 (Parametric Effects of Ambient Conditions on Thermal Safety of Wolsong (CANDU) Unit 1 Spent Fuel Dry Storage Canister)

  • Park, Jong-Woon;Chun, Moon-Hyun;Shon, Soon-Hwan;Song, Myung-Jae
    • Nuclear Engineering and Technology
    • /
    • 제25권1호
    • /
    • pp.166-177
    • /
    • 1993
  • 사용후 핵연료 건식 저장 캐니스터의 핵연료 바스켓 안에 있는 CANDU 37소자 핵연료 다발의 최대 온도를 계산하기 위한 단순화된 열해석 방법과 함께 대기 조건 인자들이 캐니스터 내부의 최대 핵연료 온도에 미치는 영향을 조사하기 위해 수행한 표본 해석 결과를 제시하였다. 3가지 모우드(mode)의 열전달이 공존하는 캐니스터 내부핵연료 다발의 복잡한 기하학적 구조에 대한 다차원열전달 문제를 풀기 위하여 건식저장 캐니스터에 저장된 CANDU 사용후 핵연료 다발들을 등가 및 동심의 핵연료 실린더(cylinder)로 대치하였다. 추가적인 입력 자료 및 열전달 상관식을 이용하여 등가 핵연료 실린더의 단순화된 축대칭, 2차원, 복수 모우드(multi-mode)의 열전달 문제를 기존의 컴퓨터 코드인 HEATING5로 해석하였다. 예측한 온도 분포와 식물 모형 실험 결과의 비교는 만족스러울 정도로 일치함을 보여주고 있다.

  • PDF

CFD Analysis of Natural Convection Flow Characteristics of Various Gases in the Spent Fuel Dry Storage System

  • Shin, Doyoung;Jeong, Uiju;Jeun, Gyoodong;Kim, Sung Joong
    • 한국유체기계학회 논문집
    • /
    • 제19권4호
    • /
    • pp.19-28
    • /
    • 2016
  • Objective of this study is to compare the inherent characteristics of natural convection flow inside the canister of spent fuel dry storage system with different backfill gases by utilizing computational fluid dynamics (CFD) code. Four working fluids were selected for comparison study. Helium currently used backfill gas for canister, air, nitrogen, and argon are frequently used as coolant in many heat transfer applications. The results indicate that helium has very distinct conductive behavior and show very weak natural convective flow compared to the others. Argon showed the strongest natural convective flow but also the worst coolability. Air and nitrogen showed similar characteristics to each other. However, due to difference in Prandtl number, nitrogen showed more effective natural convective flow. These results suggest that experimental validation for the nitrogen is needed to investigate the potential coolability other than currently commercially used helium.

Sensitivity Analysis of Thermal Parameters Affecting the Peak Cladding Temperature of Fuel Assembly

  • Ju-Chan Lee;Doyun Kim;Seung-Hwan Yu;Sungho Ko
    • 방사성폐기물학회지
    • /
    • 제21권3호
    • /
    • pp.359-370
    • /
    • 2023
  • The thermal integrity of spent nuclear fuels has to be maintained during their long-term dry storage. The detailed temperature distributions of spent fuel assemblies are essential for evaluating the integrity of their dry storage systems. In this study, a subchannel analysis model was developed for a canister of a single fuel assembly using the COBRA-SFS code. The thermal parameters affecting the peak cladding temperature (PCT) of the spent fuel assembly were identified, and sensitivity analyses were performed based on these parameters. The subchannel analysis results indicated the presence of a recirculation flow, based on natural convection, between the fuel assembly and downcomer region. The sensitivity analysis of the thermal parameters indicated that the PCT was affected by the emissivity of the fuel cladding and basket, convective heat transfer coefficient, and thermal conductivity of the fluid. However, the effects of the wall friction factor of the canister, form loss coefficient of the grid spacers, and thermal conductivities of the solid materials, on the PCT were predominantly ignored.

Effects of environmental parameters on chloride-induced stress corrosion cracking behavior of austenitic stainless steel welds for dry storage canister application

  • Seunghyun Kim;Gidong Kim;Chan Kyu Kim;Sang-Woo Song
    • Nuclear Engineering and Technology
    • /
    • 제56권1호
    • /
    • pp.317-327
    • /
    • 2024
  • This study investigated the chloride-induced stress corrosion cracking (CISCC) behavior expected to occur in welds of austenitic stainless steel, which are considered candidate materials for dry storage containers for spent nuclear fuel. The behavior was studied by varying temperature, relative humidity (RH), and chloride concentration. 304L-ER308L welded plates were processed into U-bend specimens and exposed to a cyclic corrosion chamber for 12 weeks. The CISCC behavior was then analyzed using electron microscopy. A previous study by the authors confirmed that CISCC occurred in ER308L at 60 ℃, 30% RH, and 0.6 M NaCl via selective corrosion of δ-ferrite. When the temperature was lowered from 60 ℃ to 50 ℃, CISCC still occurred. However, when the humidity was reduced to 20% RH, CISCC did not happen. This can be attributed to the retardation of the deliquescence of NaCl at lower humidity, which was insufficient to promote CISCC. Furthermore, increased chloride concentration to 1.0 M resulted in the absence of CISCC and widespread surface corrosion with severe pitting corrosion because of the increase in thin film thickness.

사용후핵연료 건식저장을 위한 기체강제순환 건조장치 예비설계 (Preliminary Design of the Forced Gas Drying System for Spent Nuclear Fuel Dry Storage)

  • 채경선;신경욱;박병목;한재현;이건희;박재석
    • 방사성폐기물학회지
    • /
    • 제15권4호
    • /
    • pp.403-409
    • /
    • 2017
  • 원자력발전소내 습식저장중인 사용후핵연료의 건식저장을 위해서는 캐니스터 내부에 사용후핵연료를 옮겨 담은 이후, 건식저장 캐니스터 내장품이나 사용후핵연료 다발의 부식방지 및 피복관의 열화방지를 위해 모든 수분은 제거해야 한다. 캐니스터 내부의 수분을 제거하는데 사용할 수 있는 기체강제순환 건조시스템 개발을 위한 연구개발이 진행중이다. 본 연구에서는 기체강제순환 건조시스템 설계, 제작을 위한 예비설계를 수행하였다. 예비설계에는 캐니스터 내부 잔존수분 제거를 위한 건조사례조사, 건조관련 규격이나 표준, 건조합격기준, 건조장치구성, 현장요구분석, 습식저장중인 사용후핵연료 특성을 포함하였다. 예비설계를 통하여 기체강제순환 건조시스템의 설계 개념도와 P&ID를 도출하였고, 이를 활용하여 건조시스템 제작을 위한 상세설계를 수행할 것이다.