• 제목/요약/키워드: Dry Sorbent

검색결과 35건 처리시간 0.025초

건식법에 의한 이산화황과 산화질소의 제거(II) - Cu-Ce 및 Cu-7Al의 효율 - (Removal of S $O_{2}$ and NO by Dry Sorbent(II) - Efficiency of Cu-Ce and Cu-7Al -)

  • 신창섭
    • 한국대기환경학회지
    • /
    • 제9권4호
    • /
    • pp.288-294
    • /
    • 1993
  • Flue gas control systems for small-scale combustors must be designed to provide highly effective removal of three criteria pollutants (S $O_{2}$, N $O_{x}$ and particulate matter), and must be safe, reliable and small. These requirements make dry, regenerative clean-up process particularly attractive and this paper describes a new concept for integrated pollutant control : a filter comprised of layered, gas permeable membranes that act as an S $O_{2}$ sorbant, a N $O_{x}$ reduction catalyst and a particulate filter. A mixed metal oxide sorbent, Cu-Ce was used as a sorbent/catalyst and the activity was compared with Cu-7Al. The S $O_{2}$ removal eficiency of Cu-Ce was increased with temperature increase up to 500$^{\circ}$C and the catalytic activity for NO was higher than that of Cu-7Al. By the sulfation of Cu-Ce, the reduction activity was increased at the temperature higher than 350$^{\circ}$C. The regeneration of Cu-Ce was very fast and some amount of elemental sulfar was found.

  • PDF

유동층 반응기에서 건식 sorbent $NaHCO_3$를 이용한 $CO_2$ 흡수반응에 미치는 유속과 온도의 영향 (Effects of Gas Velocity and Temperature on $CO_2$ Reaction Characteristics using Dry Sorbent $NaHCO_3$ in Fluidized Bed Reactor)

  • 유영우;이봉희;홍선욱;조성호;이창근
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 2003년도 춘계 학술발표회 논문집
    • /
    • pp.667-672
    • /
    • 2003
  • 화석연료의 연소로 생성되는 $CO_2$는 지구온난화의 주범으로, 대부분 화력발전 등 에너지 산업에서 발생되는 배가스로 대기 중에 방출되고 있으며, 많은 나라들이 규제를 정하고 있다. 우리나라도 선진국과 같이 2008년부터 자발적 의무를 부담할 것을 요구하는 등 국제적인 요구가 증대되고 있다.(중략)

  • PDF

석탄화력발전소 현장의 석탄연소 배가스 고도처리용 건식 분류층 반응 실증장치에서의 $SO_2$ 제거성능 특성 (Removal Characteristics of $SO_2$ in the Coal Combustion Flue Gas Treatment Convergence System)

  • 전성민;박형상;박영옥
    • 한국입자에어로졸학회지
    • /
    • 제9권4호
    • /
    • pp.239-246
    • /
    • 2013
  • The purpose of this study is to determine the feasibility of dry-type desulfurization process for actual application to coal-fired power plant. We used actual exhaust gas from Facility Y, Plant #2 to fabricate a demo-scale testing device to attempt to improve the efficiency of desulfurization. A spout-bed circulating dry scrubber convergence system connecting turbo reactor with bag filter was devised, then analyzed for performance characteristics of $SO_2$ removal for Ca/S mole ratio, superficial gas velocity, and ammonia injection, and for secondary reaction characteristics of the non-reactive sorbent at the bag filter. As a result, the installation of spout-bed circulating dry scrubber convergence system showed better economy and efficiency for removing sulfur than the existing wet/semidry-type desulfurization process. In addition, the best efficiency for desulfurization occurred when connected to the bag filter, with differential pressure maintained at 150 $mmH_2O$.

건식 흡착제를 이용한 저농도 이산화탄소 흡착 연구 (A study of low-level $CO_2$ adsorption using dry sorbents)

  • 김요섭;이주열;임윤희;신재란;박병현;김윤신
    • 한국응용과학기술학회지
    • /
    • 제31권3호
    • /
    • pp.394-401
    • /
    • 2014
  • In order to minimize a building energy consumption with ventilation, a development of smart ventilation system is very important. In this study, a dry adsorbent that is main element of smart ventilation system was developed for removing indoor $CO_2$, and evaluate the adsorption performance. Specific surface area, pore characteristic and crystal structure of the modified sorbent was measured to analyze physical properties. From this analysis, it was found that the developed absorbent has a low specific surface area, due to mesopores of substrate was filled with metal contained raw material. Additionally, through analysis of the adsorption properties, the developed adsorbent was shown a adsorption form of mesopore (type IV), which means adsorption amount was rapidly increased at the part of high-pressure. Order to applying for the field, chamber test was performed. Continuous column tests (2,500 ppm) and batch chamber tests ($4m^3$, 5,000 ppm) showed $CO_2$ removal efficiency of 95% and 88% within 1 hour, respectively.

반건식 배연탈황법에 의한 연소 페가스 중 $SO_2$제거에 관한 연구 (A Study on $SO_2$Removal in Flue Gas by Semidry Flue Gas Desulfurization Method)

  • 송호철;이윤기;박진원
    • 한국대기환경학회지
    • /
    • 제14권4호
    • /
    • pp.273-280
    • /
    • 1998
  • The investigation on the removal of 502 gas fro.In flue gas which causes serious air pollution was made by using a semi dry flue gas desulfurization method. Experiments were carried out as a function of process variables which would affect SO2 removal efficiency. Process variables inclilded SO2 inlet concentration, inlet temperature of simulated flue gas, sorbent weight fraction, and volume flow rate of sorbent slurry. In this study, used sorbent was Ca(OH), and simulated flue gas was prepared by mixing pure SO2 gas with air. Experimental conditions were varied at 140~18$0^{\circ}C$ of inlet temperature of the simulated flue gas, 500~2000ppm of inlet SO2 concentration, 0.4~1.0% of sorbent concentration, and 10~25 mL/min of flow rate of sorbent slurry. Among process variables, inlet concentration of SO2 was found to be the most significant factor to affect SO2 removal efficiency. The concentration of Ca(OH2) had a lower effect on SO2 removal than SO2 inlet concentration removal amount was 0.108, 0.141, 0.153 g SO2/g Ca(OH)2 respectively- As 200 mmol of HNO3 was added into slurry to improve removal efficiency, initial pH was maintained and solubility of slurry increased, so that removal efficiency elevated. Adding over 200 mmol of HNO3 into slurry caused removal efficiency lower. Therefore it could be concluded the optimum was 200 mmol of HNO3 input.

  • PDF

Ca계 및 Na계 흡수제의 건식 탈황 특성 비교 (Comparision of Ca- and Na- Based Dry Sorbent in Desulfurization Characteristics)

  • 문승현;현주수
    • 대한환경공학회지
    • /
    • 제31권1호
    • /
    • pp.21-28
    • /
    • 2009
  • Ca계 및 Na계 탈황제를 대상으로 열중량 분석실험과 승온탈리 실험을 수행하여 탈황제의 열적안정성, 집진기 전단 온도인 $250^{\circ}C$에서 탈황 성능, 그리고 상온에서 흡수용량 등을 비교하여 아래와 같은 결론을 도출하였다. 소석회($Ca(OH)_2$)는 약 $390^{\circ}C$에서 열 분해되기 시작하여 480~$500^{\circ}C$에 이르면 완전하게 분해되었다. 열분해 결과 생성된 생석회(CaO)의 무게는 최초 소석회 무게의 76%로 감소하였다. 중탄산나트륨($NaHCO_3$)은 약 $95^{\circ}C$에서부터 분해되기 시작하여 $190^{\circ}C$ 이하의 온도에서 완전하게 분해되어 처음 도입된 중탄산나트륨 무게와 비교하여 약 63%로 감소하였다. $250^{\circ}C$에서 실시한 열중량 분석 결과, 무수탄산나트륨($Na_2CO_3$)의 경우에는 탈황제 무게의 35%에 해당하는 $SO_2$를 흡수할 수 있고, 생석회는 15.6%, 소석회는 6.5%까지 $SO_2$를 흡수할 수 있는 것으로 나타났다. $250^{\circ}C$에서 초기반응 속도를 비교하면, Ca계 탈황제의 경우에는 초기 미반응 시간이 있는 반면에 Na계 탈황제인 무수탄산나트륨에서는 이러한 초기 미반응 시간이 없어, Ca계 반응제의 경우보다 Na계 탈황제의 경우에 $SO_2$와 더 빠른 반응이 진행되었다. 상온에서 실시한 승온탈리 실험 결과, Na계인 무수탄산나트륨보다는 Ca계인 소석회가 더 많은 $SO_2$를 흡수하였다. 따라서 저온에서는 Ca계인 소석회가 적절하고 고온에서는 무수탄산나트륨이 더 적절한 탈황제인 것으로 판단된다.

연소기체로부터 CO2 회수를 위한 건식 유동층 흡수-재생 공정의 고체순환 모사 (Modeling of Solid Circulation in a Fluidized-Bed Dry Absorption and Regeneration System for CO2 Removal from Flue Gas)

  • 최정후;박지용;이창근;조성호;손재익;류청걸;김상돈
    • Korean Chemical Engineering Research
    • /
    • 제43권2호
    • /
    • pp.286-293
    • /
    • 2005
  • 기체 수송층 흡수탑과 기포 유동층 재생탑으로 구성된 $CO_2$ 회수 공정에 대한 해석의 첫 단계로 이 공정에서 고체 순환특성을 해석하였다. 흡수제 고체 입자에 대한 입도별 물질수지를 해석하여 공정의 흐름에서 고체 흐름량과 입도 분포를 결정하였다. 실험실 규모 공정(흡수탑: 직경 25 mm, 높이 6 m; 재생탑: 직경 0.1 m, 높이 1.2 m)에서 고체순환특성을 모사하였다. 흡수탑의 입도분포는 재생탑의 입도분포와 거의 같았다. 흡수탑에서 유속과 정체층 높이가 증가함에 따라서 고체순환량과 새 흡수제 주입량은 증가하였다. 반면에 흡수탑 내 입자의 평균입경은 감소하였다. 흡수탑사이클론의 절단입도가 증가함에 따라서 고체순환속도는 감소하였으며, 새 흡수제 주입속도와 흡수탑 내 입자의 평균 입경은 증가하였다. 흡수제 입자의 마모계수가 증가함에 따라서 고체순환속도는 증가하고, 새 흡수제 주입속도는 증가하며, 흡수탑 내 입자의 평균입경은 감소하였다.

회분식 기포유동층 반응기에서 K-계열 건식흡수제의 주입수분농도 및 재생반응온도에 따른 CO2 흡수-재생 반응특성 연구 (Study of CO2 Carbonation-Regeneration Characteristics of Potassium-Based Dry Sorbents According to Water Vapor Contents of Inlet Gas and Regeneration Temperature in the Cycle Experiments of Bubbling Fluidized-Bed Reactor)

  • 박근우;박영성;박영철;조성호;이창근
    • Korean Chemical Engineering Research
    • /
    • 제47권3호
    • /
    • pp.349-354
    • /
    • 2009
  • 본 연구에서는 전력연구원으로부터 공급받은 K-계열 건식흡수제를 이용하여 회분식 기포유동층 반응기에서 흡수-재생 반복실험을 통한 $H_2O$ 주입농도 및 재생온도에 따른 반응 특성을 살펴보았다. K-계열 건식흡수제는 $CO_2$ 흡수를 위한 탄산칼륨과 내마모성과 기계적 강도를 위한 지지체로 구성되어 있다. 흡수반응과 재생반응 특성을 살펴보기 위해 처음 한 시간 동안 흡수반응을 수행하고 다음 한 시간 동안 재생반응을 수행하는 과정을 3차례 반복하여 실험하였다. $H_2O$ 농도의 영향을 파악하기 위해서 흡수반응은 $70^{\circ}C$에서 $H_2O$ 농도를 7.3, 12.2, 19.7, 30.8%로 변화하여 실험을 수행하였으며 재생반응은 $N_2$ 기체를 유동화기체로 사용하여 $150^{\circ}C$에서 수행하였다. 재생온도의 영향을 파악하기 위해서는 흡수반응에서의 $H_2O$ 농도를 12.2%에 고정한 상태에서 재생온도를 150, 200, 300, $400^{\circ}C$로 변화하여 실험을 수행하였다. 수분 함량이 $1.97\;mol\;H_2O/mol\;CO_2$인 경우 흡수반응에서 흡수율이 가장 우수함을 확인하였다. 또한 재생온도가 $400^{\circ}C$에서 가장 높은 재생율을 보이는 것을 확인하였다. 재생온도가 $150^{\circ}C$에서 재생율은 대략 60% 정도였으며 실제 두개의 유동층 반응기를 가진 연속장치의 경우 부분적인 재생을 유지하면서 운전이 수행되기 때문에 재생온도는 $150^{\circ}C$ 이상이면 적절하다고 판단된다. 실제 연속운전에서는 적절한 고체순환량을 결정하는 고체이용율과 재생에너지를 결정하는 재생온도 사이에 절충점이 존재하며 본 실험에서 얻은 데이터가 연속장치의 설계와 운전에 중요한 기초자료가 될 것이다.

고정층 반응기에서 K-계열 흡수제의 압력에 따른 HCl 흡수 거동 연구 (Effect of Pressure on HCl Absorption Behaviors of a K-based Absorbent in the Fixed Bed Reactor)

  • 김재영;박영철;조성호;류호정;백점인;박영성;문종호
    • 청정기술
    • /
    • 제19권2호
    • /
    • pp.165-172
    • /
    • 2013
  • 본 연구에서는 고정층 반응기(높이 15 cm, 내경 0.5 cm)에서 K-계열 건식 흡수제($K_2CO_3/Al_2O_3$, 한국전력공사 전력연구원)를 이용하여 반응압력 변화에 따른 염화수소 흡수 실험을 수행하였다. 반응온도는 가스화 직후, 필터를 거쳐서 주입되는 것을 가정하여 $400^{\circ}C$로 설정하였으며, 반응기체 농도는 750 ppm HCl ($N_2$ balance)으로 설정하였다. 반응압력은 1, 5, 10, 15, 20 bar로 증가시켰다. 압력이 증가할수록 K-계열 흡수제의 흡수 성능이 증가하였다. 흡수제를 구성하고 있는 주요 물질인 $K_2CO_3$가 HCl 가스와 반응하여 KCl 결정을 형성하였으며, 강한 결합에너지로 인하여 흡수제의 재생이 실질적으로 불가능하였다. 이에 대한 광학적, 물리적, 화학적 특성을 SEM, EDX, BET, TGA, XRD를 이용하여 분석하였다. $400^{\circ}C$, 20 bar 조건(가스화 이후 탈할로겐 공정의 온도 및 압력조건)에서 $K_2CO_3$ 흡수제는 Ca 계열 및 Mg 계열의 흡수제에 비해 높은 HCl 흡수능 및 HCl/$N_2$ 분리 거동을 보였다.

건식 흡착제를 이용한 차량용 이산화탄소 저감장치 개발 ($CO_2$ removal system by dry sorbent for passenger train)

  • 조용대;이주열;박덕신
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.1735-1739
    • /
    • 2008
  • Malfunction or inappropriate management of ventilation system in public transportation may cause unpleasant atmosphere or health problems to the old or feeble passengers. In this work, gaseous carbon dioxide removal system is developed and tested under the various serviced passenger cabins. Finally an optimum operating conditions for the $CO_2$ removal system will presented.

  • PDF