• 제목/요약/키워드: Drop simulation

검색결과 766건 처리시간 0.029초

EMTP MODELS를 이용한 전기철도 FACTS 설비의 제어 구현 연구 (A Study on control realization of FACTS equipment in Electric Railway Systems using EMTP MODELS)

  • 오민혁;이병하
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.329-330
    • /
    • 2006
  • The purpose of this paper is to compensate the voltage drop of the power system in the AC Electric Railway Systems. Reactive power compensation is often the most effective way to improve system voltage drop. The suitable modeling of the electric railway system should be applied to the EMTP. the dynamic characteristics of 3-Phase Induction Motor in Electric Railway Systems is considered for precise modeling. it is shown through EMTP simulation using EMTP MODELS that voltage drop can be compensated effectively by STATCOM.

  • PDF

Numerical Analysis on the Electrical Characteristics of FS TIGBT

  • Lee, Jong-Seok;Kang, Ey-Goo;Sung, Man-Young
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 추계학술대회 논문집 Vol.19
    • /
    • pp.63-64
    • /
    • 2006
  • Here we present detailed simulation results of trench field stop IGBTs. Besides the reduced on-state voltage drop there is also an Increase of forward blocking voltage. A trench gate IGBT has low on-state voltage drop mainly due to the removal of the JFET region and a field stop IGBT has high forward blocking voltages due to the trapezoidal field distribution under blocking condition. We have simulated the static characteristics of TIGBT with field stop technology by 2D simulator(MEDICI). The simulated result of forward blocking voltage and on-state voltage drop is about 1,408V and 1.3V respectively at $110{\mu}m$ N-drift thickness.

  • PDF

Adaptive Nonlinear RED Algorithm for TCP Congestion Control

  • Park, Kyung-Joon;Park, Eun-Chan;Lim, Hyuk;Cho, Chong-Ho
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.121.1-121
    • /
    • 2001
  • Congestion control is a critical issue in TCP networks, Recently, active queue management (AQM) was proposed for congestion control at routers. The random early detection RED algorithm is widely known in the AQM algorithms, We present an adaptive nonlinear RED (NRED) algorithm, which has nonlinear drop probability profile. The proposed algorithm enhanced the performance of the RED algorithm by the self-parameterization based on the traffic load Furthermore, the proposed algorithm can effectively adapt itself between he RED and the drop-tail queue management by adopting proper nonlinearity in the drop probability profile. Through simulation, we show the effectiveness of the proposed algorithm comparing with the drop-tail and the original RED algorithm.

  • PDF

낙하/충격해석을 통한 전자렌지의 내충격설계 (Design for Improving Impact Resistance of Microwave Oven Using Drop/Impact Analysis)

  • 김진곤;김정윤;김흥수
    • 동력기계공학회지
    • /
    • 제13권3호
    • /
    • pp.53-58
    • /
    • 2009
  • The importance of cost reduction has grown bigger to ensure the competetive power of products in the electric home appliances industry. Thus, it is necessary to assess the reliability due to drop-impact happenning in process of distribution of microwave ovens with the panel and cavity of thinner thickness for cost reduction. In the present study, the drop/impact simulation using the explicit code LS-DYNA3D has been carried out for improving the impact resistance of a microwave oven. This CAE-based design approach can be successfully applied to enhance the deteriorated dynamic behavior under the impact conditions of dropping height 70cm according to ISTA procedure 2A.

  • PDF

오리피스 유량해석을 통한 전륜 착륙장치의 착륙성능평가 (Nose Landing Gear Drop-test Simulation using Numerical Analysis about Orifice)

  • 황재업;배재성;황재혁;홍예선;박상준;정태경
    • 항공우주시스템공학회지
    • /
    • 제8권1호
    • /
    • pp.18-23
    • /
    • 2014
  • This thesis is simulated a aircraft nose landing gear drop-test. flow rate-to-pressure difference characteristics of damping orifices for a nose landing gear is investigated by CFD analyses. Orifice is kind of poppet valve type. it is simulated pressure drop with variable orifice area. it is simulated landing gear model by using ADAMS with CFD result. It's performance evaluated landing gear drop-test and analyzed the results.

미세입자분산 액적의 고체면에서 모세퍼짐 현상에 관한 직접수치해석 기법개발 (DEVELOPMENT OF A NUMERICAL TECHNIQUE FOR CAPILLARY SPREADING OF A DROPLET CONTAINING PARTICLES ON THE SOLID SUBSTRATE)

  • 황욱렬;정현준;김시조;김종엽
    • 한국전산유체공학회지
    • /
    • 제12권4호
    • /
    • pp.14-19
    • /
    • 2007
  • We present a direct numerical simulation technique and some preliminary results of the capillary spreading of a droplet containing particles on the solid substrate. We used the level-set method with the continuous surface stress for description of droplet spreading with interfacial tension and employed the discontinuous Galerkin method for the stabilization of the interface advection equation. The distributed Lagrangian-multipliers method has been combined for the implicit treatment of rigid particles. We investigated the droplet spreading by the capillary force and discussed effects of the presence of particles on the spreading behavior. It has been observed that a particulate drop spreads less than the pure liquid drop. The amount of spread of a particulate drop has been found smaller than that of the liquid with effectively the same viscosity as the particulate drop.

Dynamic Voltage Restorer Prototype 설계에 관한 연구 (A Study on the Design of the Dynamic Voltage Restorer Prototype)

  • 김지원;전영환;전진홍;오태규;박동욱
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제50권3호
    • /
    • pp.140-145
    • /
    • 2001
  • The instantaneous voltage drop is occurred when the fault is happened on the nearby feeders. The instantaneous voltage drop is continued during relatively short period. But, the effect of it can be very severe to some sensitive devices. That is, it can be the reason of restart or malfunction of some devices. And these phenomenons can cause the enormous economical damage and shorten the lifetime of the devices. In this paper, the device which can compensate the instantaneous voltage drop, is studied. Through the computer simulation using PSCAD/EMTDC, the validity of the control algorithm using peak detection method is verified. And the Dynamic Voltage Restorer(DVR) prototype is designed and constructed. Through the experiment, the function and performance of the DVR prototype is verified.

  • PDF

Wide-area Frequency-based Tripped Generator Locating Method for Interconnected Power Systems

  • Kook, Kyung-Soo;Liu, Yilu
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권6호
    • /
    • pp.776-785
    • /
    • 2011
  • Since the Internet-based real-time Global Positioning System(GPS) synchronized widearea power system frequency monitoring network (FNET) was proposed in 2001, it has been monitoring the power system frequency in interconnected United States power systems and numerous interesting behaviors have been observed, including frequency excursion propagation. We address the consistency of a frequency excursion detection order of frequency disturbance recorders in FNET in relation to the same generation trip, as well as the ability to recreate by power systems dynamic simulation. We also propose a new method, as an application of FNET measurement, to locate a tripped generator using power systems dynamic simulation and wide-area frequency measurement. The simulation database of all the possible trips of generators in the interconnected power systems is created using the off-line power systems dynamic simulation. When FNET detects a sudden drop in the monitoring frequency, which is most likely due to a generation trip in power systems, the proposed algorithm locates a tripped generator by finding the best matching case of the measured frequency excursion in the simulation database in terms of the frequency drop detection order and the time of monitoring points.