• Title/Summary/Keyword: Drop simulation

Search Result 766, Processing Time 0.028 seconds

Drop/Impact Simulation and Experimental Verification of a Reciprocating Compressor Body (왕복동형 압축기의 낙하충격 시뮬레이션 및 실험적 검증)

  • Kim, Tae-Jong;Kim, Moon-Saeng;Koo, Ja-Ham
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.6 s.123
    • /
    • pp.484-490
    • /
    • 2007
  • A reciprocating compressor used in domestic refrigerators can be subjected to many different forms of shock. These shocks are usually experienced during transporting the products from a manufacturer to customers. The hermetic structure of this kind of compressor makes it difficult to conduct drop tests for identifying the failure mechanism and their drop behaviors. The drop/impact simulation for a reciprocating compressor has been carried out with the explicit code LS-DYNA and its validation has been experimentally verified. Simulation results are in good agreement with those of drop test. The present method of drop/impact simulation provides an efficient and powerful solution to improve the design quality and reduce the design period.

Drop/Impact Simulation and Experimental Verification of Mobile Phone (휴대용 단말기의 낙하충격해석 및 실험적 검증)

  • Kim, Jin-Gon;Lee, Jun-Yeong;Lee, Sin-Yeong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.4
    • /
    • pp.695-702
    • /
    • 2001
  • In this paper, the drop/impact simulation for a mobile phone has been carried out with the explicit code LS-DYNA and its validation has been experimentally verified. The small size of this kind of electronics products makes it time-consuming, and difficult to conduct drop tests to detect the failure mechanism and identify their drop behaviors. Strict drop/impact performance criteria of such hand held electronic products as mobile phones play an important role in their design because these products must withstand both normal and unexpected shock. Usually, the product durability on drop impact depends on designers experience. The present reliable methodology of drop/impact simulation provides an efficient and powerful vehicle to improve the design quality and reduce the design period.

Pressure Drop in a Circular Pipe of Waste Collection Piping System (쓰레기 관로 이송 시스템의 관로 압력강하 평가)

  • Jang, Choon-Man;Lee, Sang-Yun;Suh, Sang-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.10 no.4
    • /
    • pp.55-60
    • /
    • 2007
  • This paper describes an evaluation method of pressure drop in a circular pipe of waste collection piping system. Accurate pressure drop in a piping system is very important to determine the capacity of turbo blower, which is one of the main elements in the system. Three-dimensional Navier-Stokes analysis is introduced to analyze the pressure drop in the piping system. Organic waste is selected and modeled using the result of site survey performed in an apartment area. Evaluation method of pressure drop used In the present numerical simulation is performed in the shortened pipe line prior to the calculation of the real system. Throughout the numerical simulation, pressure drop in a waste pipe is obtained and compared to the value determined by analytical method. The pressure drop obtained by numerical simulation has a good agreement with that of the analytic method. It is noted that present evaluation method is effective to determine a pressure drop in the piping system. Detailed flow characteristics inside the pipe line are also analyzed and discussed.

Evaluation of Pressure Drop in a Circular Pipe of Refuse Collecting System (쓰레기 관로이송 시스템에서의 관로 압력손실 평가)

  • Kim, Dong-Woo;Jang, Choon-Man
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2615-2620
    • /
    • 2007
  • This paper describes on pressure drop in a circular pipe of refuse collecting system. The flow characteristics inside the circular pipe are analyzed by three-dimensional Navier-Stokes analysis. In numerical analysis, an organic waste is modeled using the data obtained by site survey. Pressure drop obtained by numerical simulation is compared to the value obtained by experimental measurements for the two kinds of pipe; straight and bended type. The pressure drop obtained by numerical simulation has a good agreement with that of experiments. It is noted that the accurate prediction of pressure drop in the waste pipe is very important to determine the performance of turbo blower used in making a suction pressure in the waste pipe. Especially, the pressure drop for an organic waste is analyzed according to the mass flow rate of waste.

  • PDF

A racking Design of the Monitor by Considering the Free Drop Impact (자유낙하 충돌을 고려한 모니터 포장설계)

  • Yun Seong-Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.12 s.177
    • /
    • pp.117-123
    • /
    • 2005
  • This paper deals with the finite element model of the monitor fur the simulation of directional free drop tests such as the backward and vertex free drop as well as the associated free-drop experiment. The model was made for an unconditional stable solution fur the explicit integration algorithm. It was found through the comparison between simulation and experimental results that the general behaviors at the time of impact were observed to well correlate with each other in terms of acceleration, displacement, contact force and stress of monitor components.

Smart Phone Display Drop Simulation and Design (Smart Phone Display 낙하 Simulation과 설계)

  • Kim, Won-Jong
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.22 no.3
    • /
    • pp.381-385
    • /
    • 2019
  • In this Study, as the structure of smart phone display becomes thin to catch up with slim product trend, the reliability of display module is on the rise as a issue for product design. Especially, almost part of cellular phone should undergo drop test when they fall 1.5m above ground. Thus many manufacturers have considered design guide line using CAE and simulation for more efficive usage of limited resources om the martket. This test simulates the case when cellular phone slips through user's flingers while he is talking on the phone. This paper studies a drop simulation of glass for display in smart phone. This design for reliability improvements are suggested on the basis of the results of FE Analysis and display of smart phone design.

Damage Evaluation of CD-RW Drive by Drop Test and Simulation (CD-RW Drive의 낙하충격 손상평가)

  • Woo Jae Chul;Yun Ki Won;Seok Ki Young;Kim Heon Young;Kim Sang Bum
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.1 s.232
    • /
    • pp.81-87
    • /
    • 2005
  • A fracture of hand held device, such as radio, TV and CD-RW drive, mainly occurs due to drop situation. For CD-RW drive, the need of high reading/writing speed in conjunction with low price accelerates the fracture of the device. Computer simulation can reduce the period of development and enhance impact characteristic of device. In this study, the detailed finite element model of CD-RW drive was developed to predict the damage under drop conditions. Material property for shock absorbing damper was obtained from tensile test of raw material. A MOONEY-RIVLIN type rubber in LS-DYNA was used as the material model of damper. To assess the reliability of the developed model, drop test at 200G-2msec and 150G-10msec condition was conducted and acceleration at pick-up was compared.

Analysis of Voltage Drop under Extended Feeding in KyungBu High Speed Line (I) (경부고속선의 전력공급 안정성 검토를 위한 연장급전 조건의 전압강하 검토 (I))

  • Kim, Joo-Rak;Lee, Chang-Mu;Jang, Dong-Uk
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1432-1438
    • /
    • 2011
  • This paper presents the simulation of traction power supply system for the evaluation of voltage drop in Kyungbu high speed line. This simulation is performed in circumstance of extended feeding through vicinity substation. Extended feeding should be considered from design of system. Therefore, voltage drop at extended feeding must be accepted against regulation. In this paper, voltage drop is evaluated under condition of extended feeding targeting section from Shinchungju and Pyungtaek S/S.

  • PDF

Analysis of edge drop and development of numerical formula for edge drop control of cold rolled sheet (냉연판의 엣지드롭 해석 및 제어용 수식모델 개발)

  • Song, Gil-Ho;Park, Hae-Du;Jin, Cheol-Je;Sin, Seong-Gap
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.22 no.4
    • /
    • pp.723-730
    • /
    • 1998
  • With the introduction of edge drop control system in Tandem Cold Rolling Mill, it is necessary to develop te numerical expression for the set-up and edge drop automatic control of cold rolled sheet. As a first step we developed a simulation program which predicts profile and the amounts of edge drop at the delivery side of each stand by using roll deformation anlysis with the slit roll model. And by using the program the effect of various rolling conditions on edge drop was investigated. As a result the relations were obtained between the amounts of edge drop and rolling conditions. Based on above relations, the numerical expression was developed for the set-up and automatic control of edge drop by multi-regression of simulation results for the variation of edge drop amount with each rolling condition.

Numerical Study an Drop Breakup in Air-Assisted Spray Using the TAB Model with a Modified Drop Drag Model (TAB 모텔과 수정된 액적 항력 모텔을 이용한 공기 보초 분무에서의 액적 분열에 대한 수치적 연구)

  • 고권현;유홍선;이성혁;홍기배
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.2
    • /
    • pp.87-95
    • /
    • 2002
  • The aim of this article is to perform the numerical simulation far drop drag and breakup processes in air-assisted sprays using the Taylor analogy breakup (TAB) model with a modified drop drag model, in which a random method is newly used to consider the variation of the drop's frontal area. The predicted results for drop trajectory and Salter mean diameter (SMD) were compared with experimental data and the simulation results using the earlier published models such as TAH model, surface wave instability (Wave) model, and Wave model with original drop drag model. In addition, the effects of the breakup model constant, Ck, on prediction of spray behaviors were discussed. The results shows that the TAB model with the modified drop drag model is in better agreement with experimental data than the other models, indicating the present model is acceptable for predicting the drop breakup process in air-assisted sprays. At higher Weber numbers, the smaller Ck shows the best fitting to experimental data. It should be noted that more elaborated studies is required in order to determine the breakup model constant in the suggested model in the study.