• Title/Summary/Keyword: Drop pattern

Search Result 274, Processing Time 0.024 seconds

Analysis of Slab Joint Opening Due to Temperature Drop in Continuous Precast Concrete Slab Track (연속 프리캐스트 콘크리트 슬래브궤도에서의 온도하강에 따른 슬래브 이음매 개구량 해석)

  • Jang, Seung-Yup;Lee, Jeong-Wan
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1659-1663
    • /
    • 2011
  • Precast concrete slab track is a track structure to be installed by transporting and assembling precast concrete slabs manufactured at the factory. This method can improve concrete quality, provide easy maintenance and reduce construction time, compared with in-situ concrete track. However, the concrete slabs being continuously connected in longitudinal direction, due to the temperature change between summer and winter, the openings at slab joints have occurred. Thus, in this study, to identify the cause of this opening of slab joint, the joint opening caused by temperature drop in the longitudinally continuous precast concrete slab track has been predicted using three-dimensional finite element analysis, and compared with field measurements. Based on the proven model, the slab joint opening, and the stress pattern of concrete slab and steel reinforcement according to concrete slab-base friction properties, concrete-reinforcement bond properties, and prestressing were analyzed.

  • PDF

NUMERICAL STUDY ON FLOW CHARACTERISTIC IN THE HEAT RECOVERY STEAM GENERATOR (배열회수장치의 유동특성에 관한 수치적 연구)

  • Choi, H.K.;Yoo, G.J.;Shin, B.J.;Kim, C.H.
    • Journal of computational fluids engineering
    • /
    • v.15 no.1
    • /
    • pp.17-23
    • /
    • 2010
  • Performance improvements of the heat recovery steam generator(HRSG) can be achieved by improving the flow distribution of exhaust gases for a various type of different equipments. A number of design parameters are systematically investigated and their effects on an index of velocity deviation established. The parameters include the three shape of the transition duct and the wide range of the guide vane angles. The numerical results clearly reveal feature of the flow pattern in the transition duct, velocity deviation and pressure drop at tube bank part.

Current-Integrating DFE with Sub-UI ISI Cancellation for Multi-Drop Channels

  • Park, Hwan-Wook;Lim, Hyun-Wook;Kong, Bai-Sun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.16 no.1
    • /
    • pp.112-117
    • /
    • 2016
  • This paper presents a half-rate current-integrating DFE receiver with sub-unit interval (sub-UI) inter-symbol interference (ISI) cancellation. By having a single additional DFE tap in each data path, the proposed DFE receiver can minimize BER degradation due to input pattern dependency and feedback tap latency problems in conventional current-integrating DFE receivers. The proposed DFE receiver was designed and fabricated in a 45 nm CMOS process, whose measurement results indicated that the BER bathtub width is increased from 0.235 UI to 0.315 UI (34% improvement) at $10^{-12}$ BER level.

Numerical Analysis on Flow Characteristics of High Pressure Drop Control Valves with Anti-Cavitation Trim (Anti-Cavitation Trim을 갖는 고차압 제어밸브의 유동특성에 관한 수치해석)

  • Ahn, Y.J.;Kim, B.J.;Shin, B.R.
    • The KSFM Journal of Fluid Machinery
    • /
    • v.10 no.4
    • /
    • pp.61-70
    • /
    • 2007
  • Numerical analysis of three dimensional incompressible turbulent flows in LNG marine high pressure drop control valves was carried out by using the CFD-ACE from ESI-Group. In this study, flow characteristics of control valves with complex flow fields including cavitation effect were investigated. Simulation was performed on five models of control valve that had different orifice diameters of anti-trim and the size of valve. Comparing newly designed control valves for controling the occurrence of cavitation with the conventional valve, new valves showed a improved flow pattern with almost no cavitation.

Hemodynamic Analysis of Pig's Left Common Coronary Artery (I) (좌주간부 관상동맥에 관한 혈류역학적 분석 (I))

  • Park, Jung-Su;Chang, Ju-Hee;Moon, Su-Yeon;Shin, Se-Hyun
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1923-1929
    • /
    • 2003
  • The present study investigated the microcirculation of blood in the left common artery (LCCA). In order to develop a mathematical model for microcirculation in LCCA, the present study adopted preexisted set of measured morphological data on anatomy, mechanical properties of the coronary vessels, viscosity of blood, the basic laws of physics, and the appropriate boundary conditions. In this study, the statistical distribution of blood pressure, blood flow, and blood volume in the LCCA were determined based on the anatomical branching pattern of the coronary arterial tree and the statistical data of blood vessel dimensions. Our calculations were in good agreement with the previous studies. The present results showed that the mean longitudinal pressure drop profile was function of the vessel order numbers. It was found that the normalized pressure drop was a logarithmic function of the compliance.

  • PDF

A Numerical Analysis Study on Plate Heat Exchanger Heat Transfer Characteristic by Corrugation Angle and Pitch (주름 각도와 피치에 따른 판형 열교환기 전열특성에 관한 수치해석 연구)

  • Kang, Dae-Ki;Kim, Si-Pom;Hwang, Il-Ju;Lee, Jae-Hoon;Do, Tae-Wan;Yeo, Woon-Yeop
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.11 no.3
    • /
    • pp.154-159
    • /
    • 2012
  • For numerical analysis of the plate heat exchanger, a lot of time are required in modeling work and calculation. Whereas, this paper was purposed to identify characteristic of the plate heat exchanger through simplification of modeling by interpreting the numerical analysis proximity with the actual model. This study was also examined temperature difference between inlet side and outlet side, inner pressure drop, heat transfer area of plate and change of heat transfer coefficient on the plate depending on the inner corrugation angle and corrugation pitch of a herring bon pattern of the plate heat exchanger among chevron types of the plate exchanger.

An experimental study on ice slurry fluid and pressure drop characteristics in along a horizontal circular tube around the valve (배관 내 밸브 주위의 아이스슬러리의 유동현상 및 압력강하특성에 관한 연구)

  • Oh, C.;Mun, S.B.;Son, Y.G.
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.30 no.3
    • /
    • pp.382-388
    • /
    • 2006
  • This study experimented to understand the effect of transporting ice slurry through in pipe with valve. And at this experiment it used ethylene glycol-water solution and a concentration is 30wt%. The experimental apparatus was constructed of ice slurry generation tank, turbo flow meter, manometers for differential pressure measuring, PIV system for flow pattern measuring. illumination and along a horizontal circular tube with valve as test section. The experiments were carried out under various conditions, with velocity of fluid at the entry ranging from 0.5 to 1.5 m/s and concentration of IPF is 30%. Also valve open rate is 50%, 75%, 100%.

Theoretical Prediction of Lung Hyperinflation(LHI) Due to Asymmetric Pressure-Flow Characteristics of Human Airways During High Frequency Ventilation (HFV)

  • Cha, Eun-Jong
    • Journal of Biomedical Engineering Research
    • /
    • v.11 no.2
    • /
    • pp.195-202
    • /
    • 1990
  • The hypothesis of asymmetric resistance to explain the phenomenon of lung hyperinflation (LHI) during hlgh frequency ventilation (HFV) was quantitatively studied. LHI was predicted by modeling the ism-volume pressure-flow (IVPF) data from 5 human subjects using the empirical Rohrer's equation. Non-steadiness during HFV was compensated by em- ploying recently proposed volume-frequency diagram. Tidal volume and ventilation frequency were 100 ml and 20 Hz, respectively. Airflow pattern was a symmetric sinusoid. The predic- tion results of mean pressure drop across the airways were averaged for those 5 subjects, and compared with zero by one-sided student's t-test. A marginally significant (P<0.1) increase in mean pressure drop was observed during HFV at low lung volumes (below FRC) , which could increase mean lung volume up to one liter When the lung volume was above FRC, no significant LHI (P >0.25) was resulted. LHI seemed to be inversely related to the lung volume. These results recommend to clinically apply HFV only at lung volumes above FRC.

  • PDF

Correlation between size and velocity of drops in a spray from an internal mixing twin-fluid atomizer (내부혼합형 이류체 분사노즐에서 발생한 분무내 액적들의 크기와 속도의 상관관계)

  • Kim, Sang-Jin;Hiroyasu, H.
    • Journal of ILASS-Korea
    • /
    • v.3 no.1
    • /
    • pp.27-33
    • /
    • 1998
  • Correlations of drop size and velocity in a spray from the disintegration of liquid jet and liquid film from an internal mixing twin-fluid atomizer, were determined by phase Doppler method. The distribution pattern of Sauter mean diameter(SMD) in a spray was changed by a behavior of liquid flow. As smaller droplets became faster and slower easily by the surrounding conditions, the correlation between drop size and mean velocity was found to be varied as next 3 steps; firstly smaller droplets have a higher mean velocity at the area near atomizer, droplets have almost the same mean velocity and finally larger droplets have a higher mean velocity at the area far from an atomizer.

  • PDF

Characteristics of Pressure Drop in the Membrane Support Sheet for Reverse Osmosis (역삼투압용 막지지천의 압력강하 특성)

  • 장호남;김동필;김연철
    • Membrane Journal
    • /
    • v.3 no.1
    • /
    • pp.22-28
    • /
    • 1993
  • Fabrics of polyester, polyacrylics, nylon and cotton were tested to investigate the possibility. of using these matehals as a membrane support sheet. Considering the physical properties such as compaction rate, membrane embossing, water flux, the chemical and mechanical properties, 50 denlet polyester fabrics was found to be the appropriate material as a membrane support sheet among the tested materials. The experimental parameters such as pressure drop, compression pressure and viscosity were changed to investigate the effects of these parameters on the flow patten in this membrane support sheet. As a result, it was shown that Darcy's law could be satisfactorily applied to describe the flow pattern in this membrane support sheet.

  • PDF