• Title/Summary/Keyword: Drop methods

Search Result 618, Processing Time 0.025 seconds

Prediction of Pressure Drop Using the Internal Flow Simulation of Pulse Air Jet Bag Filters (충격기류식 여과집진기의 내부 유동 시뮬레이션 해석을 통한 압력손실 예측)

  • Jang, Kyeong-Min;Jung, Eun-Sang;Suh, Jeong-Min
    • Journal of Environmental Science International
    • /
    • v.29 no.5
    • /
    • pp.457-468
    • /
    • 2020
  • With continuous industrial development, the types, and amount of particulate matter (PM) have been increasing. Since 2018, environmental standards regarding PM have become more stringent. Pulse air jet bag filters are suitable for PM under the 20 ㎛ and, can function regardless of size, concentration and type. Filtration velocity and shape are important factors in the operation and design of the pulse air jet bag filters however, few established studies support this theory. In this research, numerical simulations were conducted based on experimental values and, several methods were employed for minimizing the pressure drop. In the pilot system, as the inlet duct velocity was faster than 19 m/sec, flow was not distributed equally and, re-entrainment occurred due to the hopper directional vortex. The multi-inlet system decelerated the hopper directional vortex by 25 ~ 30%, thereby decreasing total pressure drop by 6.6 ~ 14.7%. The guide vane system blocked the hopper directional vortex, which resulted optimal vane angle of 53°. The total pressure of the guide vane system increased by 0.5 ~ 3% at 1.5 m/min conditions. However, the filtration pressure drop decreased by 4.8 ~ 12.3% in all conditions, thereby reducing the operating cost of filter bags.

Comparison of Hip Muscle Strengthening Exercise and Stretching of Lower Extremity on Pain, Navicular Drop and Foot and Ankle Functional Ability in Plantar Fasciitis (엉덩근육 강화 운동과 하지 스트레칭이 족저근막염 환자의 통증, 주상골 하강 및 발과 발목의 기능적 능력에 미치는 효과 비교 연구)

  • Yang, Su-bin;Lee, Sang-bin
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.27 no.3
    • /
    • pp.47-55
    • /
    • 2021
  • Background: Plantar fasciitis is one of the most common conditions of the lower limbs. The present study aimed to compare the effect of hip muscle strengthening exercise and stretching of lower extremity in plantar fasciitis, with regard to pain, navicular drop and foot and ankle functional ability. Methods: A total of 42 patients diagnosed with plantar fasciitis were randomly assigned to the experimental group (n=21) that applied the hip muscle strengthening exercise and the control group(n=21) that applied the general lower limb stretching. The intervention period was 6 weeks. Results: The results of the experiment showed that the exercises for strengthening the hip muscle had significant effects on pain, navicular drop and foot and ankle functional ability In addition, lower extremity stretching showed improvement effects in pain, navicular drop and foot and ankle functional ability, however, the difference between the groups except navicular drop did not reach statistical significance Conclusion: Both interventions tested in this study were confirmed to be effective treatment options for patients with plantar fasciitis.

Analysis on Differences in Dynamic Stability of Lower Extremity Caused by Unbalance of Hamstring/Quadriceps Ratio During Drop-landing (드롭랜딩 시 Hamstring/Quadriceps ratio 불균형에 따른 하지의 동적 안정성 차이 분석)

  • Hong, Wan-Ki;Kim, Min
    • Korean Journal of Applied Biomechanics
    • /
    • v.25 no.1
    • /
    • pp.49-56
    • /
    • 2015
  • Objectives : The purpose of this study was to present quantitative data and basic references to decrease the accident risk of soccer instructors. Methods : To obtain data, we conducted an investigation on how H/Q ratio affects the dynamic stability of the lower extremity at the time of drop landing. The study targeted 13 soccer players from C University who have not had any injuries or wounds in the lower extremity joints and in any other parts of their bodies over the last 6 months. By using CMIS (USA), the players were divided into two groups according to H/Q ratios higher and lower than 69%, respectively. The subjects in each group were instructed to perform a drop landing. Results : The H/Q ratio did not affect the maximal flexion angle of the knee joints at the time of drop landing. In addition the dominant group with a relatively high H/Q ratio was observed to have increased time to reduce shock and to efficiently absorb the ground reaction force during drop landing. Also, the dominant group with a relatively high H/Q ratio utilized the strong performances of the antagonistic muscles around the hamstrings and the controlled rotatory powers of the thighs that were applied to the tibias supported by the ground. Finally, H/Q ratio, load factors, and mean and maximum EMG were significantly negatively related, whereas GRFx showed a positive relationship. In fact, these factors all affected the impact of the load from the H/Q ratio to the knee joints. Conclusion : From these findings it can be concluded that unbalanced H/Q ratio can be considered as a predictor of knee joint injury at the time of drop landing.

Muscle Properties Analysis of SCM Muscle using Smartphone postures (자세유형별 스마트폰 사용에 따른 목빗근의 근육 속성 분석)

  • Kim, In-Suk;Kim, Kyun-Young;Park, Sang-Gwan;Choi, Young-Woo;Noh, Han-Na;Kim, Jin-A
    • Journal of Korean Clinical Health Science
    • /
    • v.5 no.4
    • /
    • pp.991-997
    • /
    • 2017
  • Purpose. The purpose of this study was to muscle properties analysis of SCM(sternocleidomastoid) Muscle according to posture type when using smartphone. Methods. This study was conducted on 73 college students who are using smartphone. Subjects were analyzed myotonPRO to confirm, prone posture group, stand posture group, drop head above $45^{\circ}$in sit posture on a chair group and drop head below $45^{\circ}$in sit posture on a chair group were measured SCM muscle. The myotonPRO were measured one measurer, total 3 times. Comparative analysis of the each groups were investigated of SCM muscle properties. Results. We found that Frequency, Stiffness, Creep and Relaxation were appeared difference in each posture. F index was increased at drop head below $45^{\circ}$group than stand posture group. S index was increased at drop head above $45^{\circ}$group than prone posture group. C index was decreased at drop head below $45^{\circ}$group and drop head above $45^{\circ}$group than prone posture group. R index was decreased at drop head above $45^{\circ}$group than prone posture group. Conclusions. The muscle properties were appeared difference in each posture of SCM muscle using smartphone.

Seven Cases Report on the Foot Drop Patients with Herniated Intervertebral Lumbar Disc by Muscle Energy Technique & Korean Traditional Medicine Therapy (근에너지기법 및 한방치료를 적용한 족하수를 동반한 요추추간판탈출증 환자 치험 7례)

  • Chung, Jai-Hyeon;Yun, Young-Ung;Cheong, Seong-Hyun;Kim, Tae-Ho;Choi, Young-Jun;Kim, Sin-Woong;Lee, Cha-Ro
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.9 no.1
    • /
    • pp.27-37
    • /
    • 2014
  • Objectives : The present study reports seven foot drop patients with herniated intervertebral lumbar disc treated by Muscle Energy Technique and Korean traditional medicine therapy. Methods : Seven foot drop patients with herniated intervertebral lumbar disc were treated by Muscle Energy Rechnique and Korean traditional medicine therapy and were assessed by Manual Muscle Test, numeric rating scale, and oswestry low back pain disability index. Results : Among seven foot drop patients, two cases showed complete recovery, three cases showed recovery over good grade, and two cases showed recovery over good grade after temporary weakness. numeric rating scale and oswestry low back pain disability index of all cases showed improvement. Conclusions : Seven foot drop patients with herniated intervertebral lumbar disc were treated by Muscle Energy Rechnique and Korean traditional medicine therapy and showed improvement. It is anticipated that this report benefits the future in depth study and clinical treatments on the foot drop symptom in korean medicine.

  • PDF

Evaluation of the Crack Initiation of Curved Compact Tension Specimens of a Zr-2.5Nb Pressure Tube Using the Unloading Compliance and Direct Current Potential Drop Methods (제하 컴플라이언스법 및 직류전위차법을 이용한 Zr-2.5Nb 압력관 휘어진 CT 시편의 균열시작 평가)

  • Jeong, Hyeon-Cheol;Ahn, Sang-Bok;Kim, Young-Suk
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.8 s.239
    • /
    • pp.1118-1122
    • /
    • 2005
  • The direct current potential drop (DCPD) method and the unloading compliance (UC) method with a crack opening displacement gauge were applied simultaneously to the Zr-2.5Nb curved compact tension (CCT) specimens to determine which of the two methods can precisely determine the crack initiation point and hence the crack length for evaluation of their fracture toughness. The DCPD method detected the crack initiation at a smaller load-line displacement compared to the UC method. As a verification, a direct observation of the fracture surfaces on the curved compact tension specimens was made on the CCT specimens experiencing either 0.8 to 1.0 mm load line displacement or various loads from $50\%\;to\;80\%$ of the maximum peak load, or $P_{max}$. The DCPD method is concluded to be more precise in determining the crack initiation and fracture toughness, J in Zr-2.5Nb CCT specimens than the UC method.

Development of Integrated HVAC Noise Analysis Program for Ships (선박용 통합 HVAC 소음해석 프로그램 개발)

  • Han, Ju-Bum;Hong, Suk-Yoon;Song, Jee-Hun;Kim, Nho-Seong;Chun, Seung-Hyun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.588-593
    • /
    • 2011
  • The Main design parameters of ship HVAC systems are pressure drop and noise analysis of ducts. The Noise prediction for HVAC(Heating, Ventilating and Air Conditioning) systems are normally performed by empirical method suggested by NEBB(National Environmental Balancing Bureau, 1994), but NEBB's method is not suitable for the ship HVAC systems. In this paper, numerical analysis methods are used to develop a noise prediction method for the ship HVAC systems, especially for large ducts. To develop regression formula of attenuation of sound pressure level in large duct, Boundary Element Method(BEM) is used. Using dynamic loss coefficient which is suggested by ASHRAE fitting data base and numerical methods of HVAC noise analysis, integrated HVAC noise analysis of Program is developed. The developed program can present pressure drop and noise analysis of the ship HVAC systems. To verify the accuracy and convenience of the developed program, prediction of HVAC system for Semi-Submersible Drilling RIG is carried out and the results are compared with measurement of noise level during sea trial.

  • PDF

Reinforced concrete beams under drop-weight impact loads

  • May, Ian M.;Chen, Yi;Owen, D. Roger J.;Feng, Y.T.;Thiele, Philip J.
    • Computers and Concrete
    • /
    • v.3 no.2_3
    • /
    • pp.79-90
    • /
    • 2006
  • This paper describes the results of an investigation into high mass-low velocity impact behaviour of reinforced concrete beams. Tests have been conducted on fifteen 2.7 m or 1.5 m span beams under drop-weight loads. A high-speed video camera has been used at rates of up to 4,500 frames per second in order to record the crack formation, propagation, particle spallation and scabbing. In some tests the strain in the reinforcement has been recorded using "Durham" strain gauged bars, a technique developed by Scott and Marchand (2000) in which the strain gauges are embedded in the bars, so that the strains in the reinforcement can be recorded without affecting the bond between the concrete and the reinforcement. The impact force acting on the beams has been measured using a load cell placed within the impactor. A high-speed data logging system has been used to record the impact load, strains, accelerations, etc., so that time histories can be obtained. This research has led to the development of computational techniques based on combined continuum/discontinuum methods (finite/discrete element methods) to permit the simulation of impact loaded reinforced concrete beams. The implementation has been within the software package ELFEN (2004). Beams, similar to those tested, have been analysed using ELFEN a good agreement has been obtained for both the load-time histories and the crack patterns.

Novel PWM-driven methods of inverter for removing DC offset current (인버터 출력 전류의 DC offset 제거를 위한 PWM 구동방법)

  • Hong, Kinam;Choy, Ick;Choi, Juyeop;An, Jinung;Lee, Dongha
    • Proceedings of the KIPE Conference
    • /
    • 2011.11a
    • /
    • pp.221-222
    • /
    • 2011
  • 본 논문은 인버터의 PWM구동 시 출력 전류에 발생하는 DC offset을 제거 하는 방법을 제안한다. 인버터의 PWM구동 시 소자 단락을 막기 위해 필수적으로 적용하는 deadtime과 각 스위치 소자의 voltage drop으로 인해 출력에 왜곡이 발생한다. 이상적인 스위치인 경우에는 이 두 가지의 왜곡을 feedforward로 보상하면 된다. 하지만 스위치 소자가 이상적이지 않기 때문에 각 스위치 소자의 voltage drop의 차이와 on & off time delay의 차이는 출력 전류에 DC offset을 발생시킨다. 따라서 deadtime과 스위치 voltage drop에 대한 보상과 함께 출력 전류의 DC offset을 feedback으로 하여 보상되지 못한 왜곡을 추가적으로 보상하여 결론적으로 출력 전류의 DC offset을 제거할 수 있게 하였다. 제안된 기법은 시뮬레이션을 통하여 그 타당성을 확인하였다.

  • PDF

A Study on the Mathematical Interpretation o Hydraulic Behaviour in Packing Tower (충전탑에서 수력학적 거동의 수학적 해석 연구)

  • 김석택
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.17 no.1
    • /
    • pp.51-56
    • /
    • 2001
  • This study was carried out to interpret mathematically hydraulic behaviour in packing tower which packed 50 mm plastic Hiflow-ring with a dimension of 300 mm wide and 1,400 mm high. In view of energy saving, the recent packing. 50 mm plastic Higlow-ring was superior to conventional packings because of low pressure drop in high loads. As relative error between numerically predicted and experimentally obtained values was less then 6% in the loading and flooding point, it found that therir results appeared to be adequate. Comparison of hose two values in both dry and wet packing conditions. relative errors amount to 3.96 and 5.6%, respectively. In order to evaluate the operating characteristics of packing, the type, size, and material for packings must be estimated in various system and loads. This study is able to calculated pressure drop, hold-up, gas and liquid loads using mathematical interpretation. For these calculation, the specific constants of each packings must be calculated first all. The method of mathematical interpretation in this study turned out to be superior to the existing methods because of reduced errors at loading and flooding point.

  • PDF