• Title/Summary/Keyword: Drop methods

Search Result 618, Processing Time 0.022 seconds

A Study on One Factorial Longitudinal Data Analysis with Informative Drop-out

  • Lee, Ki-Hoon
    • Journal of the Korean Data and Information Science Society
    • /
    • v.17 no.4
    • /
    • pp.1053-1065
    • /
    • 2006
  • This paper proposes a method in one-way layouts for longitudinal data with informative drop-out. When dropouts are informative, that is, correlated with unobserved data and/or the previous observed data, the simple imputation methods such as 'last observation carried forward' (LOCF) methods would arise the bias of the testing models. The maximum likelihood procedure combined with a logit model for the drop-out process is proposed to test treatment effects for one factorial designs and compared with LOCF method in two examples.

  • PDF

The Effect of Air Vent Holes and Stacking Methods of Fruits and Vegetables Boxes on Static Pressure Drop in Pressure Cooling System (청과물상자의 통기공 및 상자적재방법이 정압강하에 미치는 영향)

  • 김의웅;김병삼;남궁배;정진웅;김동철;금동혁
    • Journal of Biosystems Engineering
    • /
    • v.20 no.4
    • /
    • pp.360-367
    • /
    • 1995
  • The effect of air vent holes, stacking methods of boxes and clearance between boxes on static pressure drop, were measured to design of pressure cooling system. Static pressure drops in air vent hole of carton box were measured for different hole opening ratio from 1% to 5%. Static pressure drop was expressed as a function of superficial velocity as second-degree polynomial. At given static pressure in plenum chamber, static pressure drop in boxes was shown as second-degree polynomial of the number of carton box in series stacking method, as first-degree polynomial in height and parallel stacking method. In pressure cooling of 24 boxes of Tsugaru apple, air flow rates through clearance between the boxes were shown 1.27 and 1.65 times than those of through the inside of boxes at the plenum pressure of 10mmAq and 20mmAq, respectively.

  • PDF

Immediate Effect of Kinesiology Taping on Gait Function in Stroke Patients with Foot Drop

  • Kim, Jinuk
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.11 no.2
    • /
    • pp.2060-2064
    • /
    • 2020
  • Background: Recently, the kinesiology taping (KT) method was reported to be effective in improving walking ability in foot drop patients after stroke, but the clinical basis is still unclear. Objectives: The KT method was compared with ankle-foot orthotics (AFO) to investigate gait ability in foot drop patients after stroke. Design: Crossover study design. Methods: In this study, 11 stroke patients with foot drop participated. Walking ability of all subjects for both conditions (KT and AFO) was measured using the GAITRite system. The order of application of the two conditions was determined randomly by drawing lots. Wilcoxon signed-rank test was used to compare walking ability between the two conditions. The level of statistical significance was set at P<.05. Results: There were no significant differences between the KT and AFO methods in terms of velocity, cadence, step length, and stride length (P>.05, all). Conclusion: This study recommends KT as an alternative to the AFO, since KT provides evidence of preventing of foot drops and improving gait ability in stroke patient.

Static Pressure Drop of Airflow in Packed-bed of Fruits and Vegetables (청과물 퇴적층에서의 공기유동 정압강하)

  • 김의웅;김병삼;남궁배;정진웅;김동철;금동혁
    • Journal of Biosystems Engineering
    • /
    • v.21 no.1
    • /
    • pp.44-51
    • /
    • 1996
  • The purpose of this paper is to obtain the basic data for design of pressure cooling system. Static pressure drop, as a function of superficial velocity, was measured for different stacking methods and stacking heights of some fruits and vegetables. At given superficial velocity, sphericity and void fraction had a much greater influence on static pressure drop than average diameter of spherical fruits such as apple, peach, tomato and kiwi fruit. Among cylindrical vegetables such as cucumber, carrot, radish and chinese cabbage, cucumber showed different pattern of static pressure drop because of its bended shape, radish showed less static pressure drop than other vegetables because its large sizes of voids. When cucumber and spinach were stacked vertically and horizontally to air flow, a much greater static pressure drop was shown in vertical than in horizontal type, therefore static pressure drop was affected not only by void fraction but also by void shape. Also, in packed-beds of fruits and vegetables, static pressure drop could be estimated very well by Ramsins equation.

  • PDF

Immediate Effect of Foot Drop Stimulator in Outpatients with Chronic Stroke: A Mixed Method Study

  • Park, Jaeyoung;Lee, Dooho;Oh, Donghwan
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.11 no.1
    • /
    • pp.1992-1998
    • /
    • 2020
  • Background: The foot drop stimulator is designed to improve the walking ability of foot drop in patients after stroke, however, studies on clinical effects are still lacking. Objective: To investigate the effect of a foot drop stimulator on the walking and balancing abilities of foot drop patients after a stroke. Design: One-Group (Pretest-Posttest) Design. Methods: All subjects walked in all three conditions: foot drop stimulator (FDS) ankle foot orthosis (AFO) and barefoot. Primary outcome measures were assessed for walking and balance using a 10-m walking test (10MWT) and a timed up and go test (TUG). Secondary outcome measures consisted of a brief user interview, and the patients recorded the advantages and disadvantages of each condition. Results: FDS, AFO, and barefoot conditions showed a statistically significant difference in 10MWT and TUG (P<.001) as a result of comparing three conditions. FDS and AFO were significantly different from the barefoot condition as post-hoc results; however, there was no significant difference between the two conditions (P>.05). Conclusion: In this study, the foot drop stimulator contributed to improving the balance ability, and the walking ability was similar to the effect of the ankle-foot orthosis.

Influence of Longitudinal Arch of Foot on the Strength and Muscle Activity of the Abductor Hallucis in Subjects with and without Navicular Drop Sign

  • Jeon, In-Cheol
    • The Journal of Korean Physical Therapy
    • /
    • v.31 no.4
    • /
    • pp.222-227
    • /
    • 2019
  • Purpose: This study examined the influence of longitudinal arch on the strength and muscle activity of the abductor hallucis in the standing position in subjects with and without navicular drop signs. Methods: A sample of 34 subjects with and without navicular drop signs between 22 and 28 years of age were enrolled in this study. The strength and muscle activity of the abductor hallucis was measured using a tensiometer. The Smart KEMA System and electromyography device was used on the subjects with and without navicular drop signs. Two groups were classified using the navicular drop test to identify the longitudinal arch of the foot. The strength of the abductor hallucis was evaluated in standing, both with and without an external arch support condition. The two-way mixed ANOVA was used. The level of statistical significance was set to ${\alpha}=0.05$. Results: The strength and muscle activity of the abductor hallucis in standing was significantly higher with external arch support than that without the external arch support in the group with navicular drop signs. There was no significant difference in the abductor hallucis strength and muscle activity with and without external arch support in the subjects without navicular drop signs. Conclusions: The strength and muscle activity of the abductor hallucis in standing can be influenced by the external arch support in the group with navicular drop signs. The strength measurement of the abductor hallucis in standing should be separately performed in conditions with and without longitudinal arch of foot.

A numerical analysis and experimental study on the prediction of spray characteristics (분무특성 예측을 위한 이론적 접근과 실험적 연구)

  • Yoon, S.J.;Cho, D.J.
    • Journal of ILASS-Korea
    • /
    • v.3 no.2
    • /
    • pp.1-13
    • /
    • 1998
  • A theoretical and experimental study was carried out to predict the drop size distribution of the pressure swirl atomizer. Various analytical methods using the Kelvin-Helmholtz instability theory were tried to examine the wave growth on cylindrical liquid sheets. Cylinderical liquid sheets were extended to the case with the conical sheets. Perturbations due to tangential motion as well as longitudinal one were taken into account. And it was assumed that the breakup occurs when amplitude ratio exceeds exp(12), drop sizes were predicted only by theoretical approach. Drop size distribution was obtained by using maximum entropy formalism. Seven constraints in the form of the definition of mean diameter were used in this formulation in order to avoid the difficulties of estimating source terms. In this study $D_{10}$ only was introduced into the formulation as a constraint. The predicted drop size and drop size distribution agreed well with the measured data.

  • PDF

Sensitivity of a control rod worth estimate to neutron detector position by time-dependent Monte Carlo simulations of the rod drop experiment

  • Jong Min Park;Cheol Ho Pyeon;Hyung Jin Shim
    • Nuclear Engineering and Technology
    • /
    • v.56 no.3
    • /
    • pp.916-921
    • /
    • 2024
  • The control rod worth sensitivity to the neutron detector position in the rod drop experiment is studied by the time-dependent Monte Carlo (TDMC) neutron transport calculations for AGN-201K educational reactor and the Kyoto University Critical Assembly. The TDMC simulations of the rod drop experiments are conducted by the Seoul National University Monte Carlo (MC) code, McCARD, yielding time-dependent neutron densities at detector positions. The detector-position-dependent results of the total control rod worth calculated by the extrapolation, the integral counting, and the inverse methods are compared with the numerical reference using the MC eigenvalue calculations and the experimental results. From these comparisons, it is observed that the total control rod worth can be estimated with a considerable difference depending on the detector position through the rod drop experiment. The proposed TDMC simulation of the rod drop experiment can be applied for searching a better detector position or quantifying a bias for the control rod worth measurement.

Comparison of the thickness of the gastrocnemius through ultrasonography during heel-drop exercise performance

  • Gal, Dan-Bee;Lee, Su-Young
    • Physical Therapy Rehabilitation Science
    • /
    • v.5 no.2
    • /
    • pp.89-94
    • /
    • 2016
  • Objective: This study was aimed to compare the thickness and pennation angle of gastrocnemius through ultrasonography during the heel-drop exercise on ankle dorsiflexion angle. Design: Cross-sectional study. Methods: Nineteen normal adults in their 20s had voluntarily participated in this study. All subjects performed the ankle heel-drop exercise with ankle dorsiflexed to $0^{\circ}$, $10^{\circ}$, and $20^{\circ}$: heel-drop exercise with ankle dorsiflexed to $0^{\circ}$ was executed on floor-level, heel-drop exercise with ankle dorsiflexed to $10^{\circ}$ on a wooden-block of 2.3 cm in height, and heel-drop exercise with ankle dorsiflexed to $20^{\circ}$ on a wooden-block of 5.5 cm in height. In each regimen, the subjects completed a session of 100 heel-drop exercises (10 repetitions${\times}$10 sets; with 30 seconds rest following each set; with 24 hours rest following each exercise). Before and immediately after each heel-drop exercise, the thickness and pennation angle of gastrocnemius were measured using an ultrasonography. Results: After the performance of the heel drop exercises with ankle dorsiflexed to $0^{\circ}$, $10^{\circ}$, and $20^{\circ}$, the thickness of the gastrocnemius was significantly higher than pre-exercise (p<0.05), and furthermore heel-drop exercise with ankle dorsiflexed to $10^{\circ}$ was significantly higher than exercise with the ankle dorsiflexed to $0^{\circ}$ (p<0.05). However, as for the pennation angle of the gastrocnemius, there were no significant changes after each heel-drop exercise. Conclusions: This finding suggest that the heel-drop exercise with ankle dorsiflexed to $0^{\circ}$, $10^{\circ}$, and $20^{\circ}$ is effective on the strengthening of the gastrocnemius. Furthermore, the heel-drop exercise with the ankle dorsiflexed to $10^{\circ}$ is more effective than with the ankle dorsiflexed to $0^{\circ}$.

Reliability of Navicular Drop Measurements in Standing and Sitting Positions

  • Park, Ji-Won;Chang, Jong-Sung;Nam, Ki-Seok
    • The Journal of Korean Physical Therapy
    • /
    • v.22 no.6
    • /
    • pp.29-33
    • /
    • 2010
  • Purpose: This study was designed to investigate inter-rater and intra-rater reliability of navicular drop measurements by clinicians in sitting and standing positions. Methods: Fourteen subjects with pronated foot were recruited. Two physical therapists randomly assessed the same patients on different occasions but on the same day. Almost all patients were assessed on more than one day. The intra-rater and inter-rater reliability of navicular dropwas estimated by calculation of the intraclass correlation coefficient (ICC). Results: The intra-rater reliability of navicular drop measurements ranged from 0.93 to 0.87, the inter-rater reliability from 0.98 to 0.70 with the patient in standing and sitting positions. These results showed good reliability for calculated variables. Intra-rater and inter-rater reliability of navicular drop in standing position was higher than those of sitting position. Conclusion: Although inter-rater and intra-rater reliability of navicular drop in the sitting position was lower than in the standing position, measurement of navicular drop in the sitting position showed good reliability and was acceptable for patients who could not stand alone without assistance. We recommend that having the patient in the standing position is appropriate in navicular drop measurement.