• 제목/요약/키워드: Drop Size Distribution

검색결과 156건 처리시간 0.028초

압력식 스월 노즐의 액적 크기분포 예측에 관한 연구 (A Study on the Prediction of the Drop Size Distribution of Pressure-Swirl Atomizer)

  • 조대진;윤석주;김동우
    • 한국분무공학회지
    • /
    • 제1권1호
    • /
    • pp.44-54
    • /
    • 1996
  • A theoretical and experimental study was carried out on the prediction of drop size distribution of the pressure swirl atomizer. Drop size distribution was obtained by using maximum entropy formal ism. Several constraints in the form of the definition of mean diameter were used in this formulation in order to avoid the difficulties of the estimating source terms. In this study $D_{10}$ was only introduced into the formulation as a constraint. A drop size obtained by using linear Kelvin-Helmholtz instability theory was considered as an unknown characteristic length scale. As a result, the calculated drop size was agreed well with measured mean diameter, particularly with $D_{32}$. The predicted drop size distribution was agreed welt with experimental data measured wi th Malvern 2600.

  • PDF

분무특성 예측을 위한 이론적 접근과 실험적 연구 (A numerical analysis and experimental study on the prediction of spray characteristics)

  • 윤석주;조대진
    • 한국분무공학회지
    • /
    • 제3권2호
    • /
    • pp.1-13
    • /
    • 1998
  • A theoretical and experimental study was carried out to predict the drop size distribution of the pressure swirl atomizer. Various analytical methods using the Kelvin-Helmholtz instability theory were tried to examine the wave growth on cylindrical liquid sheets. Cylinderical liquid sheets were extended to the case with the conical sheets. Perturbations due to tangential motion as well as longitudinal one were taken into account. And it was assumed that the breakup occurs when amplitude ratio exceeds exp(12), drop sizes were predicted only by theoretical approach. Drop size distribution was obtained by using maximum entropy formalism. Seven constraints in the form of the definition of mean diameter were used in this formulation in order to avoid the difficulties of estimating source terms. In this study $D_{10}$ only was introduced into the formulation as a constraint. The predicted drop size and drop size distribution agreed well with the measured data.

  • PDF

Raindrop Size Distribution Over Northeastern Coast of Brazil

  • Tenorio Ricardo Sarmento;Kwon Byung-Hyuk;Silva Moraes Marcia Cristina da
    • Journal of information and communication convergence engineering
    • /
    • 제4권1호
    • /
    • pp.46-52
    • /
    • 2006
  • Precipitation measurement with ground-based radar needs an information of the raindrop size distribution (RSD) characteristics. A 10-month dataset was collected in tropical Atlantic coastal zone of northeastern Brazil where the weather radar was installed. The number of drop was mainly recorded in 300 - 500 drop $mm^{-3}$, of which the maximum was registered around 1.1 mm drop diameter.

PARSIVEL 측정 자료를 활용한 대관령 산악지역 강수입자분포 모형 연구 (A Study on a Model of Rainfall Drop-Size Distribution over Daegwanryeong Mountainous Area Using PARSIVEL Observations)

  • 박래설;장민;오성남;홍윤기
    • 한국지구과학회지
    • /
    • 제35권7호
    • /
    • pp.518-528
    • /
    • 2014
  • 본 연구에서는 대관령 지역에서의 광학우적계(PARSIVEL disdrometer) 강수관측으로부터 산출된 강수율에 따른 강수입자분포 자료를 바탕으로 기존의 강수입자분포 모형을 개선하였다. 선행 연구에서 제안한 다양한 강수입자분포 모형과 측정 자료와의 상관성을 분석한 결과, 대관령 지역에 적용 가능한 원형 모형은 개선된 ${\Gamma}$ 분포 모형임을 확인하였다. 원형 모형을 대관령 지역에 적용할 수 있도록, 민감도 실험을 통해 최적의 매개변수들(${\alpha}$, A, B)을 산정하였으며, 다섯 가지 강수율에 대한 강수입자분포 모형을 제안하였다. 강수율에 따른 강수입자분포 모형의 결과는 관측에서 측정된 값과 높은 상관성($R^2=0.975$)을 보였다. 강수율에 따라 표현되는 강수입자분포 모형을 일반화 형태로 개선하기 위해 강수율과 매개변수의 상관성을 도출하여 일반식을 결정하였다. 일반화된 강수입자분포 모형은 대관령 지역의 강수입자분포 측정 자료와 높은 상관성($R^2=0.953$)을 보였으며, 이는 본 연구에서 제안한 모형이 대관령 지역의 강수입자분포를 모의하는데 효과적임을 의미한다. 그러나 본 연구에서 제안된 강수입자분포 모형은 대관령 지역의 강수입자분포에만 최적화 되었다는 한계성이 있어, 따라서 한반도를 대표하는 모형을 개발하기 위해서는 다른 지역에 대한 광범위한 측정이 필요하다.

액주형 이류체노즐의 반경반향 분무특성에 관한 연구 (A Study on the Radial Spray Performance of a Plaint-Jet Twin-Fluid Nozzle)

  • 최진철;노병준;강신재
    • 대한기계학회논문집
    • /
    • 제18권3호
    • /
    • pp.662-669
    • /
    • 1994
  • In the combustion system, the optimum spray conditions reduce the pollutant emission of exhaust gas and enhance the fuel efficiency. The spray characteristics-the drop size, the drop velocity, the number density and the mass flux, become increasingly important in the design of combustor and in testifying numerical simulation of spray flow in the combustor. The purposes of this study are to clarify the spray characteristics of twin-fluid nozzle and to offer the data for combustor design and the numerical simulation of a spray flow. Spatial drop diameter was measured by immersion sampling method. The mean diameter, size distribution and uniformity of drop were analyzed with variations of air/liquid mass flow ratio. The results show that the SMD increases with the liquid supply flow rate and decreases with the air supply velocity. The radial distribution of SMD shows the larger drops can diffuse farther to the boundary of spray. And the drop size range is found to be wider close to the spray boundary where the maximum SMD locates.

현탁중합의 계면안정에 따른 폴리스티렌 입자 제조 (Preparation of Polystyrene particles based on interfacial stability of suspension polymerization)

  • 이진호;이상남;박문수;김은경;문명준
    • 한국인쇄학회지
    • /
    • 제20권1호
    • /
    • pp.65-78
    • /
    • 2002
  • The suspension polymerization of styrene was carried out to obtain the narrow-size distribution of particle by using poly(vinyl alcohol) (PVA) as suspension stabilizer according to the degree of hydrolysis and the molecular weight. The stabilizing properties of suspension are also dependent on the interfacial tension of aqueous solution when PVA is added. When the polymerization process was carried out with low hydrolyzed PVA, it gave single, well-defined particles, while high hydrolyzed PVA gave clusters. The size of particle produced in this study ranged between 5${\mu}{\textrm}{m}$ and 10${\mu}{\textrm}{m}$. The suspending agent, PVA, influences on the drop size and drop stability, When the molecular weight of PVA is increased, the drop size decreases and the drops become more stable toward coalescence. An increase in the PVA concentration decreases the mean drop size and narrows the drop size distribution.

  • PDF

공기보조 분사기와 고압 선회식 분사기의 특성 비교 - Part II: 미시적 분무특성 (Comparison of Overall Characteristics between an Air-Assisted Fuel Injector and a High-Pressure Swirl Injector- Part II: Microscopic Spray Characteristics)

  • 장창수;최상민
    • 한국자동차공학회논문집
    • /
    • 제8권5호
    • /
    • pp.28-35
    • /
    • 2000
  • As a second part of the comparison study, microscopic features of an air-assisted fuel injector(AAFI) and a high-pressure swirl injector (HPSI) were characterized. They consist of the internal spray structure in terms of fuel mass and drop diameter, the overall atomization performance with respect to operating parameters and the drop size distribution. Large droplets are concentrated in around the head part of a spray field of the HPSI, while in the case of the AAFI, they were distributed in the tail part. Although the AAFI showed the better atomization performance, the feasible ranges of operating parameters such as injection and ambient pressure were found to be wider in the HPSI. Drop size distribution of the AAFI sprays was more dispersed than that of the HPSI. Drop size distribution of the AAFI sprays was more dispersed than that of the HPSI. However, at the well-atomized condition, it appeared to be very uniform.

  • PDF

나무 아래 빗방울(雨滴)의 물리적 특성변화 분석 (Evaluation of Changesin the Physical Characteristics of Raindrops Under a Canopy in Central Korea)

  • 김진관;김민석;양동윤;임영신
    • 한국지형학회지
    • /
    • 제23권3호
    • /
    • pp.105-122
    • /
    • 2016
  • To evaluate the changes in the physical characteristics of open rainfall related to canopy effects and rainfall intensity in Korea, the terminal velocity of raindrops and drop size distributions(DSD) were continuously measured by an optical-laser disdrometer in an open site(Op) and in two forest stands(Th1: Larix leptolepis, Th2: Pinus koraiensis) during five rainfall events in 2008. The terminal velocity, DSD and two forms of kinetic energy(KE, $Jm^{-2}$ $mm^{-1}$; KER, $Jm^{-2}$ $h^{-1}$) of open rainfall drops were determined and were compared with those of throughfall drops under two different canopy heights. The effects of the canopy and rainfall intensity, together with wind speed, on the changes in drop size and kinetic energy of throughfall were evaluated. Throughfall drops were larger than open rainfall drops. The distribution of terminal velocities for the drop sizes measured at Th2 was lower than that at Op; however, at Th1 the distribution was similar to that at Op. The total kinetic energy of throughfall at Th1 and Th2 was higher than the total kinetic energy of open rainfall, and the kinetic energy distribution for the drop sizes wassimilar to the drop size distribution. The observed throughfall-KER at Th1 was lower than an estimate previously produced using a model. The overestimation from the modeled value at Th1 was likely to be due to overestimated values of a square root transformation of fall height and its coefficient in the model because the distributions of terminal velocity for the drop size measured at Th1 were similar to those of open rainfall.

주위기체내에서의 두 액체분무간의 유동간섭현상에 대한 정상적 고찰 (An Experimental Study on the Behavior of Twin-Spray with Flow Interaction in a Condensable Environment)

  • 이상룡;정태식;한기수
    • 대한기계학회논문집
    • /
    • 제10권3호
    • /
    • pp.326-334
    • /
    • 1986
  • The effects of flow interaction between adjacent sprays in twin-spray system on the spatial distribution of injected liquid (water) and drop size distribution in condensable (steam) environment were carefully observed through experiments. The spatial distribution of injected liquid in twin-spray system appears to be more uniform than the simple superposition of the spatial distributions of liquid obtained from each individual spray. Drop size distribution was obtained by using the immersion sampling technique. It was found that, in the twin-spray, the larger numbers of small drops are collected throughout the spraying region due to the increase of entrainment velocity of ambient steam compared with the case of simple superposition of each individual spray. Moreover, in the overlapped portion of the twin-spray, the drop size distribution was changed also due to the collision between large drops. As a result, the behavior of twin-spray system (and eventually multiple-spray system) can not be predicted precisely by simple superposition of the behaviors of each constituting spray. Hence, for the design of multiple spray system, the effect of flow interaction between sprays should be taken into account seriously.

Gaussian 액적 크기 분포 함수를 이용한 분무형 화재 현상 해석 (Analysis of Sodium Spray Fire Using Gaussian Droplet Size Distribution)

  • 김병호;한도희;서숭혁
    • 한국수소및신에너지학회논문집
    • /
    • 제15권1호
    • /
    • pp.72-81
    • /
    • 2004
  • Study on the analysis of sodium spray fire using Gaussian drop size distribution, which redistributes a droplet spectrum with given mean diameter if its size classes with critical diameter(D>8mm) occur, was carried out. In this case, the oversized droplets were reduced to a stable diameter. Results calculated by the code using Gaussian drop size distribution were in better agreement with AI experimental results than those of NACOM and SPRAY code. The effect of variance on pressure in the test cell appeared greatly by introducing Gaussian function, which could represent various sodium droplet size distribution. The increase of the variance with mean droplet size resulted had an important effect upon the pressure in the test cell.