• 제목/요약/키워드: Drop Safety

검색결과 327건 처리시간 0.024초

멤브레인형 LNG선 화물창 단열시스템의 수면낙하 내충격 응답해석 -II : 내충격 응답거동에 미치는 영향 고찰- (Wet Drop Impact Response Analysis of CCS in Membrane Type LNG Carriers -II : Consideration of Effects on Impact Response Behaviors-)

  • 이상갑;황정오;김화수
    • 대한조선학회논문집
    • /
    • 제45권6호
    • /
    • pp.735-749
    • /
    • 2008
  • For the development of the original technique of structural safety assessment of Cargo Containment System(CCS) in membrane type LNG carriers, it is necessary to understand the characteristics of dynamic response behavior of CCS structure under sloshing impact pressure. In the previous study, the wet drop impact response analyses of CCS structure in membrane Mark III type LNG carriers were carried out by using Fluid-Structure Interaction(FSI) analysis technique of LS-DYNA code, and were also validated through a series of wet drop experiments for the enhancement of more accurate shock response analysis technique. In this study, the characteristics of structural shock response behaviors of CCS structure were sufficiently figured out by careful examinations of the effects of specimen weight, drop height, incident angle, corrugation and stiffness of inner hull on its shock response behaviors. The shock response analysis of upward shooting fluid to inner hull was performed, and the reason of faster strain response than shock pressure one was also figured out.

선박용 디젤엔진의 미세먼지저감 장치에 다공판과 믹서의 장착이 미치는 영향에 대한 수치해석적 연구 (Numerical Study of Impact for Particulate Matter Reduction Device According to Installation of Perforated Plate and Mixer on Marine Diesel Engine)

  • 윤병규;조상현;류영현
    • 해양환경안전학회지
    • /
    • 제25권7호
    • /
    • pp.968-973
    • /
    • 2019
  • 본 논문에서는 선박용 디젤엔진의 미세먼지저감 장치에 장착된 다공판 및 믹서의 형상과 배치에 따른 압력강하와 유동균일도 특성에 대한 연구를 진행하였다. 미세먼지저감 장치에 장착된 다공판 및 믹서는 미세먼지저감 장치 내의 배출가스 및 산화/환원제의 유동균일도를 높여 배출가스 저감 성능을 높이는 긍정적인 효과와 함께 시스템의 배압을 상승시키는 부정적인 효과도 동시에 지니고 있다. 본 연구에서는 5개의 다공판, 1개의 믹서를 Case 별로 조합하여 6개의 사양에 대해서 유동해석을 통해 각각 유동균일도 및 압력 강하를 계산하였으며, 최적의 다공판 및 믹서의 형상과 배치를 선정하였다.

원자력발전소의 방사성폐기물 드럼 운반을 위한 볼트체결방식의 두꺼운 철판을 이용한 IP-2형 운반용기의 구조 안전성 해석 및 시험 (Structural Safety Test and Analysis of Type IP-2 Transport Packages with Bolted Lid Type and Thick Steel Plate for Radioactive Waste Drums in a NPP)

  • 이상진;김동학;이경호;김정묵;서기석
    • 방사성폐기물학회지
    • /
    • 제5권3호
    • /
    • pp.199-212
    • /
    • 2007
  • IP-2형 운반용기는 정상운반조건에서의 자유낙하시험 및 적층시험을 수행한 후에 운반내용물의 분산 및 유실이 없어야 하며 외부표면에서의 방사선량률이 20%이상 증가할 수 있는 차폐능력의 상실이 없어야 한다. 본 연구에서는 두꺼운 철판을 구조재로 사용하며 볼트체결방식의 뚜껑을 가진 IP-2형 운반용기에 대한 구조 안전성을 평가하기 위한 해석적인 방안을 제안하였다. 해석적인 방법을 통하여 원자력발전소에서 발생된 방사성폐기물 드럼을 폐기물 처리시설에서 임시저장고까지 운반하기 위한 두 종류의 IP-2형 방사성폐기물 운반용기에 대하여 자유낙하조건에서 운반내용물의 분산 및 유실과 차폐손실이 없음을 확인하였다. 자유낙하조건에서 운반내용물의 분산 및 유실을 평가하기 위하여 최대 볼트단면 평균응력값과 최대 뚜껑열림량을 볼트의 인장강도와 뚜껑부에 존재하는 단차와 비교 평가하였다. 또한 최대 차폐두께 감소량을 이용하여 차폐손실을 평가하였다. 자유낙하조건에 대한 동적충돌해석을 검증하고 구조 안전성을 시험적으로 평가하기 위하여 자유낙하시험을 다양한 방향으로 실시하였다. 자유낙하시험에서는 운반내용물의 분산 및 유실은 볼트체결방식의 뚜껑에서 볼트의 파손 및 플랜지의 변형 등을 검사하여 평가하였으며, 차폐손실은 초음파 두께 측정기를 이용한 차폐두께를 측정하여 평가하였다. 해석에 대한 검증을 위하여 시험에서 취득한 변형률과 가속도를 동일한 위치에서 얻어진 해석결과와 비교하였다. 해석결과는 시험결과에 비하여 보수적인 결과를 보여주므로 해석에서 입증한 IP-2형 방사성폐기물 운반용기의 안전성은 보수적인 결과이다. 마지막으로 유한요소해석을 통하여 적층조건에 대한 IP-2형 방사성폐기물 운반용기는 안전함을 입증하였다.

  • PDF

낙하 충격을 받는 다점 구속 장치를 착용한 헬기 승무원의 상해도 평가에 관한 연구 (A Study on the Injury Assessment of Helicopter's Crew with Multi Point Restraint System under Drop Impact)

  • 이중현;이영신
    • 대한기계학회논문집A
    • /
    • 제33권6호
    • /
    • pp.590-599
    • /
    • 2009
  • In this paper, a method of modeling seat belts on crew seat during dynamic seat testing was studied. The body segments of the occupant were modeled with joints. The joints consisted with various stiffnesses, dampings, and frictions. Three types of seat belt restraint systems were investigated. The analysis for on the injury assessment of helicopter's crew under drop impact was conducted. The effectiveness of the seat belt system for crashworthiness and safety was evaluated. As the results of impact analysis, head, neck and spine of the crew can be easily damaged in the vertical direction more than the longitudinal direction. Based on the verified model, behavior of human body was studied with three-point restraint systems. The displacement and injury level of the 12-point restraint system was the smallest.

점안용 웅담약침액의 안점막자극실험 (Eye Irritation Test of Fel Ursi Pharmacopuncture Solutions for Eye Drop)

  • 서형식
    • 대한약침학회지
    • /
    • 제11권3호
    • /
    • pp.93-97
    • /
    • 2008
  • Objective: This study was done to investigate the safety of Fel Ursi pharmacopuncture solution manufactured with freezing dryness method to use eye drop. Methods: The eye irritation test of this material was performed according to the Regulation of Korea Food & Drug Administration(2005. 10. 21, KFDA 2005-60). After Fel Ursi pharmacopuncture solution was medicated in the left eye of the rabbits, the author observed eye irritation of the cornea, iris, conjunctiva at 1, 2, 3, 4 & 7day. Results: 1. After Fel Ursi pharmacopuncture solution was medicated in the left eye of the rabbits, there wasn't physical problem at 9 rabbits. 2. After Fel Ursi pharmacopuncture solution was medicated in the left eye of the rabbits, there wasn't eye irritation of the cornea, iris, conjunctiva at 1, 2, 3, 4 & 7day. Conclusions: I suggested that Fel Ursi pharmacopuncture solution didn't induced eye irritation in rabbits.

점안용 웅담.우황약침액의 안점막자극실험 (Eye Irritation Test of Fel Ursi & Bovis Calculus Pharmacopuncture Solutions for Eye Drop)

  • 서형식
    • 대한약침학회지
    • /
    • 제11권3호
    • /
    • pp.99-104
    • /
    • 2008
  • Objective: This study was done to investigate the safety of Fel Ursi & Bovis Calculus pharmacopuncture solution manufactured with freezing dryness method to use eye drop. Methods: The eye irritation test of this material was performed according to the Regulation of Korea Food & Drug Administration(2005. 10. 21, KFDA 2005-60). After Fel Ursi & Bovis Calculus pharmacopuncture solution was medicated in the left eye of the rabbits, the author observed eye irritation of the cornea, iris, conjunctiva at 1, 2, 3, 4 & 7day. Results: 1. After Fel Ursi & Bovis Calculus pharmacopuncture solution was medicated in the left eye of the rabbits, there wasn't physical problem at 9 rabbits. 2. After Fel Ursi & Bovis Calculus pharmacopuncture solution was medicated in the left eye of the rabbits, there wasn't eye irritation of the cornea, iris, conjunctiva at 1, 2, 3, 4 & 7day. Conclusions: I suggested that Fel Ursi & Bovis Calculus pharmacopuncture solution didn't induced eye irritation in rabbits.

점안용 소염약침액의 안점막자극실험 (Eye Irritation Test of Soyeom Pharmacopuncture Solution for Eye Drop)

  • 서형식
    • 대한약침학회지
    • /
    • 제11권2호
    • /
    • pp.75-79
    • /
    • 2008
  • Objectives This study was done to investigate the safety of Soyeom pharmacopuncture solution manufactured with freezing dryness method to use eye drop. Methods The eye irritation test of this material was performed according to the Regulation of Korea Food & Drug Administration(2005. 10. 21, KFDA 2005-60). After Soyeom pharmacopuncture solution was medicated in the left eye of the rabbits, the auther observed eye irritation of the cornea, iris, conjunctiva at 1, 2, 3, 4 & 7day. Results 1. After Soyeom pharmacopuncture solution was medicated in the left eye of the rabbits, there wasn't physical problem at 9 rabbits. 2. After Soyeom pharmacopuncture solution was medicated in the left eye of the rabbits, there wasn't eye irritation of the cornea, iris, conjunctiva at 1, 2, 3, 4 & 7day. Conclusions I suggested that Soyeom pharmacopuncture solution didn't induced eye irritation in rabbits.

점안용 우황약침액의 안점막자극실험 (Eye Irritation Test of Bovis Calculus Pharmacopuncture Solutions for Eye Drop)

  • 서형식
    • 대한약침학회지
    • /
    • 제11권2호
    • /
    • pp.81-85
    • /
    • 2008
  • Objective This study was done to investigate the safety of Bovis Calculus pharmacopuncture solution manufactured with freezing dryness method to use eye drop. Methods The eye irritation test of this material was performed according to the Regulation of Korea Food & Drug Administration (2005. 10. 21, KFDA 2005-60). After Bovis Calculus pharmacopuncture solution was medicated in the left eye of the rabbits, the auther observed eye irritation of the cornea, iris, conjunctiva at 1, 2, 3, 4 & 7day. Results 1. After Bovis Calculus pharmacopuncture solution was medicated in the left eye of the rabbits, there wasn't physical problem at 9 rabbits. 2. After Bovis Calculus pharmacopuncture solutionwas medicated in the left eye of the rabbits, there wasn't eye irritation of the cornea, iris, conjunctiva at 1, 2, 3, 4 & 7day. Conclusions I suggested that Bovis Calculus pharmacopuncture solution didn't induced eye irritation in rabbits.

Occupational Dose Analysis of Spent Resin Handling Accident During NPP Decommissioning

  • Hyunjin Lee;Chang-Lak Kim;Sang-Rae Moon;Sun-Kee Lee
    • 방사성폐기물학회지
    • /
    • 제21권2호
    • /
    • pp.247-253
    • /
    • 2023
  • According to NSSC Notice No. 2021-10, safety analysis needs to be introduced in the decommissioning plan. Public and occupational dose analyses should be conducted, specifically for unexpected radiological accidents. Herein, based on the risk matrix and analytic hierarchy process, the method of selecting accident scenarios during the decommissioning of nuclear power plants has been proposed. During decommissioning, the generated spent resin exhibits relatively higher activity than other generated wastes. When accidents occur, the release fraction varies depending on the conditioning method of radioactive waste and type of radioactive nuclides or accidents. Occupational dose analyses for 2 (fire and drop) among 11 accident scenarios have been performed. The radiation doses of the additional exposures caused by the fire and drop accidents are 1.67 and 4.77 mSv, respectively.

자동차용 강화유리와 그 시험방법에 대한 연구 (A Study on Toughened Glass Used for Vehicles and Its Testing Methods)

  • 안호순;권해붕;이광범;전상우;손영삼
    • 자동차안전학회지
    • /
    • 제7권3호
    • /
    • pp.14-18
    • /
    • 2015
  • Toughened glass is known to have about four times larger external impact resistance than that of original glass. This study is aimed to verify that ceramic-printed toughened glass does not meet of GTR(Global Technical Regulations) No. 6 and its strength is lower than that of original glass through tests. The tests were conducted on the test pieces of original glass, toughened glass, and ceramic-printed toughened glass from five glass manufacturers. In Test 1, a 227g steel ball was dropped from a height of 2 meters, and damage was checked according to the test method of GTR No. 6. In Test 2, a steel ball was freely dropped from different heights and limited damage height was determined. In the result of Test 1 according to the test method of GTR No. 6, while all five test pieces of toughened glasses were not damaged, all the ceramic-printed toughened glass from the five manufacturers were damaged. In the result of Test 2, none of the five test pieces of toughened glass were damaged by a 10m ball drop, meanwhile, the original glasses were damaged by an average of 3m ball drop. And the results of the tests show that the ceramic-printed toughened glass does not have the features of toughened glass due to its very low strength. Therefore, this study contributes to the safety of consumers by considering the GTR No. 6, and by revising the toughened glass test method.