• Title/Summary/Keyword: Drop Safety

Search Result 328, Processing Time 0.024 seconds

Industry safety characteristic of Prismatic EDLCs (각형 전기이중층 커패시터의 산업 안전성)

  • 김경민;장인영;강안수
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2004.05a
    • /
    • pp.247-257
    • /
    • 2004
  • Electrodes were fabricated based on activated carbon powder BP-20, conducting agent such as Super P, vapor grown carbon fiber (VGCF) and acetylene black (AB), and the mixed binders of flexible poly(vinylidenefluoridehexafluoropropylene) [P(VdF-co-HFP)] and cross linking dispersion agent of polyvinylpyrrolidone (PVP) to increase mechanical strength. According to impedance measurement of the electrode with the addition of conducting agent, we found that it was possible to charge rapidly by the fast steady-state current convergence due to low equivalent series resistance (AC-ESR, fast charge transfer rate at interface between electrode and electrolyte and low RC time constant. The self-discharge of unit cell showed that diffusion process was controlled by the ion concentration difference of initial electrolyte due to the characteristics of Electric Double Layer Capacitor (EDLC) charged by ion adsorption in the beginning, but this by current leakage through the double-layer at the electrode/electrolyte interface had a minor effect and voltages of curves were remained constant regardless of electrode material. We found that the 2.3V/230F grade EDLC would be applied to industrial safety usage such as uninterrupted power supply (UPS) because of the constant DC-ESR by IR drop regardless of discharge current.

  • PDF

A Study On the Safety Management of construction equipment Using Smart Phone Technology (Focused on poclain and mobile elevated work platform) ("스마트폰" 기반을 활용한 건설장비 안전관리에 관한 연구 (굴삭기, 고소작업대중심으로))

  • Jo, Jeong-Ho;Im, Jae-Chang;Go, Yeong-Uk;Gang, Gyeong-Sik
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2012.04a
    • /
    • pp.43-59
    • /
    • 2012
  • As contemporary building construction type is getting higher and deeper,construction equipment usage is getting more, and related fatal accidents are on an increasing trend. In these days, due to the deteriorating construction business circumstance, job finding problem of equipment operator, and dumping contract, equipment lease suppliers are putin jeopardy. In high-rise building construction, especially tower crane, mobile elevated work platform and other High place operation cars among construction equipment cause many critical accidents because of drop supply of construction biding bringing out dumping contract could cause unsafe and poor construction management. Because of this, a method was drawn which could grasp the present state of construction equipment management and manage safety of the equipment more easily for accident prevention by choosing 2 kinds of Construction equipment which cause safety accident frequently among the equipment mainly used in construction site. This study suggested a method about construction equipment safety management using "smart phone" base which could be used in safety management for construction equipment by whomever in construction site. After attachment of QR code included safety checklist, It became possible that site managers could check more efficiently by scanning with their smart phone when they inspect equipment. Moreover, by the construction interested who didn't know what and how they have to inspect could point out unsafe condition in the early stage of equipment entering or take unsafe one out of the site by using new smart phone safety checking system is installed, it became possible that critical accident caused by construction equipment was prevented in advance.

  • PDF

Impact Resistance Testing of NK55 Ophthalmic Lenses in Domestic Market (국내 유통 NK55 재질 안경렌즈의 내충격 시험 평가)

  • Park, Mijung;Jeon, Inchul;Hwang, Kwang Hoon;Byun, Woongjin;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.3
    • /
    • pp.229-235
    • /
    • 2011
  • Purpose: The present study was performed to evaluate the safety of ophthalmic lenses in domestic market since eyeglasses wearers could be exposed to the negligent accident by damaged ophthalmic lenses. Method: Totally, 160 ophthalmic lenses (NK55, ${n_{d}}$ = 1.56) with the refractive powers of -3D, -6D, +3D, +6D manufactured by 4 companies in domestic market were evaluated using drop ball test. In accordance with FDA standard, steel ball (~16 g) was freely dropped on these ophthalmic lenses from 127 cm high and the surfaces of lenses were observed. Results: From the study, center thicknesses of NK55 ophthalmic lenses manufactured by 4 different companies showed somewhat different numbers even though the lenses had the same refractive index and powers. All convex lenses of +3D, +6D were evaluated as the safe lenses since there was no damage such as crack and broken found on the lens surfaces after drop ball testing. However, some noticeable broken was shown on the surfaces of concave lenses with relatively thinner center thickness. Especially, 59(73.8%) of total 80 concave lenses with the refractive power of -3D and -6D classified as unacceptable lenses to FDA standard. Conclusions: From the results, the negligent accident by damaged ophthalmic lenses should be considered as well as the correction of visual acuity, design and price when customers purchase eyeglasses. Thus, the enforcement regulation like drop ball testing of uncut ophthalmic lens could be suggested to guarantee the safety of ophthalmic lenses in domestic market.

Electrostatic Electrification Relaxation Properties of Polyester Rayon Non-woven Fabric due to Weight Variation (중량변화에 의한 폴리에스터 레이온 부직포의 정전기 대전 완화특성)

  • Lee, Sung-Ill;Park, Yong-Soon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.12
    • /
    • pp.977-981
    • /
    • 2011
  • Non-wovens polyester rayon samples were manufactured, and the electrification properties of electrostatics were measured for three different samples (15 g/$m^2$, 25 g/$m^2$, and 40 g/$m^2$) with the environmental settings of temperature (20~40$^{\circ}C$) and humidity (40~90%). The conclusions are as follows. Heavy sample generated more static electricity when the temperature was constant. The static electricity decreased slowly when the humidity is less than 70%, while it sharply decreased over 70% humidity condition. For non-woven polyester rayon, static charge decreased as temperature and humidity increased. As the weight increased, less time were taken for the electrification voltage to drop to the half.

Development of Multi Channel Gas Leakage Detector for Large Facility (대규모 시설을 위한 다채널 가스 누설 경보기 개발)

  • Jeong, Kyu-Won
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.3
    • /
    • pp.1-7
    • /
    • 2008
  • As a clean fuel, LNG or LPG is widely used in large restaurants or plants instead of coal. These fuels are easy to use and cheap. However, they are inflammable very much and easily exploded at the worst. So there are many laws and regulations legislated for the handling and usage of the gas facilities. Nevertheless, very harsh explosions occurred in several domestic or foreign places. In this paper a gas detection and alarm system was developed for large facilities. A new concept for connecting many gas detectors was proposed and based upon that a system including hardware and software have been developed and tested. Although up to 16 gas detectors apart 1 km from main controller can be connected currently, this system can be easily expanded for more detectors because each gas detector receiver communicates with main controller using industrial standard RS-485 multi drop technique. Furthermore several additive functions was included for the installation and maintenance convenience.

The Variation of Cooling Charateristics Due to the Weber Number of Droplet (액적의 Weber 수에 따른 냉각특성의 변화)

  • 방창훈;양창호
    • Journal of the Korean Society of Safety
    • /
    • v.18 no.1
    • /
    • pp.33-37
    • /
    • 2003
  • The objective of the present work is to examine the variation of cooling characteristics due to the Weber number of droplet on a heated surface. The surface temperatures varied from 72.5 - $106.1^{\circ}C$ on steel and Teflon, when Weber number was 60, 180, 300. The results are as follows; In the case of the same droplet size, the initial temperature of solid increases the indepth temperature of solid more drop. In the case of the same surface temperature, Weber number increases with increasing the cooling effect of droplet. The time-average heat flux increases with increasing the initial temperature of solid and Weber number. The evaporation time decreases with increasing the initial temperature of solid and Weber number.

A Study on Construction of POP System with Reliable Acquisition of Production Data (생산실적의 신뢰성 향상을 위한 POP시스템 구축에 관한 연구)

  • Park, Je-Won;Lee, Chang-Ho
    • Journal of the Korea Safety Management & Science
    • /
    • v.8 no.6
    • /
    • pp.79-90
    • /
    • 2006
  • Recently the construction of the ERP(Enterprise Resource Planning) system becomes accomplished actively from the many enterprises. But the many problems occur in acquisition of production data which is a fundamental data of system. Also to delay the acquisition of the production result is fatal in the efficient business operation. The construction of the POP(Point of Production) system which acquires production data at real time is become accomplished widely, In the POP system it is most important to acquire the production data which is accurate. But the many enterprises drop the competitive power with acquisition of the data which could not be trusted. In this paper, we analyze these causes and present the method which it can improve the reliability of production data. Also we introduce a real application case.

A Study on Corrosion Fatigue Crack Growth Behavior in Al-Alloy 7075-T651 (I) (Al-Alloy 7075-T651의 부식피로균열 성장거동에 관한 연구(I))

  • 김봉철;한지원;우흥식
    • Journal of the Korean Society of Safety
    • /
    • v.13 no.4
    • /
    • pp.113-120
    • /
    • 1998
  • Fatigue crack growth rates(i.e. crack initiation and crack growth of short and long crack) are investigated using commercial plates of high strength Al alloy 7075-T651 for the transverse-longitudinal(T-L) direction in air, water and sea water. Also, the evaluation direct current potential drop(D.C.P.D) method and the fractographical analysis by SEM are carried out. Near threshold region, short crack growth rates were much faster than those of comparable long cracks, and these short crack growth rates actually decrease with increasing crack growth and eventually merge with long crack data. Fatigue crack propagation rates in aggressive media(i.e. sea water) increase noticeably over three times those in air. One of the most significant characters in this phenomenon as a corrosion-fatigue causes an acceleration in crack growth rates. Sea water environment, particularly Cl$^{[-10]}$ solution brings the most detrimental effects to aluminum alloy. The result of fractographical morphology in air, water and sea water by SEM shows obvious dimpled rupture and typical striation in air, but transgranular fracture surface in water and sea water.

  • PDF

Instrumented Drop Weight Impact Testing of Polymer Materials (계장화에 의한 고분자 재료의 낙하추식 충격시험)

  • 장경영;김갑용;최만용
    • Journal of the Korean Society of Safety
    • /
    • v.13 no.2
    • /
    • pp.3-12
    • /
    • 1998
  • Polymer materials have been used offensively as construction materials for automobiles, ships, and airplanes in recent years, and their impact resistance has been obliged to be examined. In the present study, a dropped load and a specimen, equipped with high responsible strain gauges respectively, were dropped and then the changes of load and absorption energy with time were observed. It was found that the waveforms for dropped weight coincided with output signal wave for specimen during the destruction test. Based on this experimental result, three disc type of specimens with different compositions were prepared and examined. This instrumented impact test method showed that each specimen can be distinguished from each other better than conventional tests and is expected to contribute to assess test results of impact resistance for some materials under development.

  • PDF

J-R Curve Evaluation According to the Crack Length Measurement Techniques Under Reverse Cyclic Loading (역사이클하중하에서의 균열길이 측정법에 따른 파괴저항곡선의 평가)

  • 원종일;우흥식;석창성
    • Journal of the Korean Society of Safety
    • /
    • v.13 no.4
    • /
    • pp.96-101
    • /
    • 1998
  • J-R curve tests were performed on 1T compact specimens of SA516 Gr. 70 carbon steels under reverse cyclic loading. A Direct-Current Potential Drop (DCPD) method, one of the nondestructive techniques to detect flaw of structure, is being increasingly used for monitoring crack initiation and stable crack growth in typical fracture mechanics specimens for J-R testing. In many aspects this method is simpler than the unloading compliance method. The objective of this paper is to evaluate the J-R Curve according to the crack length measurement techniques under reverse cyclic loading. In order to prove the reliability and repeatability of the DCPD method, the crack length measured by using DCPD method was compared to one determined from unloading compliance. Consequently, this DCPD method correlated well with J-R curves and crack extension measurements determined from unloading compliance method.

  • PDF