• Title/Summary/Keyword: Driving pressure

Search Result 668, Processing Time 0.024 seconds

A Numerical Study of the Effect of Small Passenger Car's Grille Shape on the Aerodynamic Performance (소형 승용 차량의 그릴 형상이 차량의 공력 성능에 미치는 영향에 관한 수치해석 연구)

  • Kim, Jaemin;Cho, Hyeongkyu;Kim, Taekgi;Kim, Moonsang;Kim, Yongsuk;Kim, Yongnyun
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.23 no.1
    • /
    • pp.74-87
    • /
    • 2015
  • A numerical parametric study has been accomplished to figure out the effect of grille shape built in a small passenger car on the aerodynamic performance such as drag and mass flow rate through CRFM(Condenser Radiator Fan Module). Three grille opening parameters and three grille mesh parameters are selected and adopted to a simple shape passenger car model. This research will provide a design guideline for grille opening geometry and mesh shape in the grille. FLUENT, which is very well known commercial code, hires k-${\epsilon}$ turbulence model at the driving speed of 110km/h with moving wall boundary condition. A porous media condition is prepared to estimate the pressure drop amount through CRFM parts.

One-Touch Type Immunosenging Lab-on-a-chip for Portable Point-of-care System (휴대용 POC 시스템을 위한 원터치형 면역 센싱 랩온어칩)

  • Park, Sin-Wook;Kang, Tae-Ho;Lee, Jun-Hwang;Yoon, Hyun-C.;Yang, Sang-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.8
    • /
    • pp.1424-1429
    • /
    • 2007
  • This paper presents a simple and reliable one-touch type multi-immunosensing lab-on-a-chip (LOC) detecting antibodies as multi-disease markers using electrochemical method suitable for a portable point-of-care system (POCS). The multi-stacked LOC consists of a PDMS space layer for liquids loading, a PDMS valve layer with 50 im in height for the membrane, a PDMS channel layer for the fluid paths, and a glass layer for multi electrodes. For the disposable immunoassay which needs sequential flow control of sample and buffer liquids according to the designed strategies, reliable and easy-controlled on-chip operation mechanisms without any electric power are necessary. The driving forces of sequential liquids transfer are the capillary attraction force and the pneumatic pressure generated by air bladder push. These passive fluid transport mechanisms are suitable for single-use LOC module. Prior to the application of detection of the antibody as a disease marker, the model experiments were performed with anti-DNP antibody and anti-biotin antibody as target analytes. The flow test results demonstrate that we can control the fluid flow easily by using the capillary stop valve and the PDMS check valves. By the model tests, we confirmed that the proposed LOC is easily applicable to the bioanalytic immunosensors using bioelectrocatalysis.

Design and Prototyping of a Novel Type Piezoelectric Micro-pump

  • Oh, Jin-Heon;Lim, Jong-Nam;Lee, Seung-Su;Heo, Jun;Lim, Kee-Joe
    • Transactions on Electrical and Electronic Materials
    • /
    • v.9 no.5
    • /
    • pp.181-185
    • /
    • 2008
  • Using the extensional vibration mode of PZT ring, a piezopump is successfully made. The PZT ring is polarized with thickness direction. The traveling extensional wave along the circumference of the ring is obtained by dividing two standing waves which are temporally and spatially phase shifted by 90 degrees from each other. The proposed piezopump is consisted of coaxial cylindrical shells that are bonded piezoelectric ceramic ring. The pump takes an unobtrusive operation into the simple displacing mechanism using peristaltic traveling waves without the physical moving parts. The finite elements analysis on the proposed pump model is carried out to verify its operation principle and design by the commercial FEM software. Components of piezopump were made, assembled, and tested to validate the concepts of the proposed pump and confirm the simulation results. The performance of the proposed piezopump is about 580 ${\mu}l/min$ in flow rate with the highest pressure level of 0.85 kPa, when the driving voltage is 150 $V_p$, 57 kHz.

An Experimental Investigation of Direct Condensation of Steam Jet in Subcooled Water

  • Kim, Yeon-Sik;Chung, Moon-Ki;Park, Jee-Won;Chun, Moon-Hyun
    • Nuclear Engineering and Technology
    • /
    • v.29 no.1
    • /
    • pp.45-57
    • /
    • 1997
  • The direct contact condensation phenomenon, which occurs when steam is injected into the subcooled water, has been experimentally investigated. Two plume shapes in the stable condensation regime are found to be conical and ellipsoidal shapes depending on the steam mass flux and the liquid subcooling. Divergent plumes, however, are found when the subcooling is relatively small. The measured expansion ratio of the maximum plume diameter to the injector inner diameter ranges from 1.0 to 2.3. By means of fitting a large amount of measured data, an empirical correlation is obtained to predict the steam plume length as a function of a dimensionless steam mass flux and a driving potential for the condensation process. The average heat transfer coefficient of direct contact condensation has been found to be in the range 1.0~3.5 ㎿/$m^2$.$^{\circ}C$. Present results show that the magnitude of the average condensation heat transfer coefficient depends mainly on the steam mass fin By using dynamic pressure measurements and visual observations, six regimes of direct contact condensation have been identified on a condensation regime map, which are chugging, transition region from chugging to condensation oscillation, condensation oscillation, bubbling condensation oscillation, stable condensation, and interfacial oscillation condensation. The regime boundaries are quite clearly distinguishable except the boundaries of bubbling condensation oscillation and interfacial oscillation condensation.

  • PDF

A Study on Gerotor Design with Optimum Tip Clearance for Low Speed High Torque Gerotor Hydraulic Motor (저속 고토오크 제로터 유압모터의 최적 이 끝 틈새를 갖는 제로터 설계 연구)

  • Seo, J.S.;Chung, H.S.;Jeong, H.M.
    • Journal of Power System Engineering
    • /
    • v.10 no.4
    • /
    • pp.119-126
    • /
    • 2006
  • Gerotor hydraulic motor is widely used in hydraulic systems due to its low speed, high torque output and compactness in rotational direct driving of a heavy weight. Gerotor is a Planar mechanism consisted of a pair of rotor and circular teeth of stator assembly which forms a closed space, so called a chamber. The motion of rotor relative to the circular tooth is produced by the pressure difference of hydraulic operating fluid between the adjacent chamber. As all active contact points of rotor and circular teeth are subjected to very high sliding friction, a reduction in the performance of the gerotor hydraulic motor can not be avoided. Therefore, the core design parameters of gerotor profile used in hydraulic motors is to minimize a friction force by high contact stresses. The analytical design method of gerotor profile, based on envelope of a family of curves, is proposed. In this study, the influence of the tip clearances on three critical contact points between rotor and circular teeth of stator assembly has been explored by experimental data in this paper. At the same time a improvement method to reduce the friction force is proposed and the tip clearances on three critical points for getting an optimum gerotor profile are also analyzed.

  • PDF

Synchronous Control of an Asymmetrical Dual Redundant EHA (비대칭 이중화 EHA의 동기 제어)

  • Lee, Seong Ryeol;Hong, Yeh Sun
    • Journal of Drive and Control
    • /
    • v.13 no.2
    • /
    • pp.1-9
    • /
    • 2016
  • In this paper, an elementary force fighting problem was investigated. The problem is encountered when a double-rod type EHA(electro-hydrostatic actuator) is combined with a single-rod type EHA to build a redundant actuator system with synchronized motion. When the rod-side chambers of the two different types of EHAs have the same effective piston areas and are simultaneously pressurized by an external load, the two EHAs behave identically, sharing the external load equally. However, when the piston head-side chamber of the single rod type EHA, having a larger effective area than the rod-side chamber, is pressurized by the external load, an abnormal force fighting between the two EHAs occurs, unless their pump speeds are properly decoupled. In this study, the output drive forces of each EHA were obtained from the cylinder pressure signals and applied to the position control for each EHA to maintain the balance between their pump speeds. Adding minor force difference feedback loops to the position control, the force fighting phenomena could be eliminated and steady state synchronization errors were reduced. The power consumption of the pumps also could be remarkably reduced, avoiding unnecessarily high load pressures to the pumps.

Selection of Evaluation Indicators for Flood Risk Assessment Using DPSIR Framework (DPSIR 체계를 이용한 홍수위험도 평가을 위한 평가인자의 선정)

  • Lee, Gyu-Min;Chung, Eun-Sung;Jun, Kyung-Soo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.51-51
    • /
    • 2011
  • 유역의 홍수위험도를 산정하기 위해서는 홍수의 발생가능성과 유역의 홍수방어 능력 등의 환경적, 공학적 요소 이외에도 홍수로 인한 피해 및 영향의 종류에 따라 사회적, 경제적, 문화적, 공학적인 요소를 반영해야 한다. 이들 홍수 피해 요소는 그 중요성이나 특성별로 홍수로부터의 방어 비중이 다르게 설정될 수 있으며 지역별로도 차이를 나타낼 수 있다. 본 연구에서는 홍수위험도를 평가하기 위한 인자 선정에 지속가능성 평가 모형인 DPSIR (Driving force-Pressure-States-Impacts-Response)을 이용하여 환경적, 공학적 요소뿐만 아니라 사회적, 경제적, 문화적인 요소를 반영하고자 한다. DPSIR 모형은 유역의 영향 인자들을 지표로 선정하며 각 지표간의 유기적 관계를 반영하는 구조로 이루어져 홍수로 인하여 인자 간에 발생하는 반응을 묘사할 수 있는 장점이 있다. 또한 인자를 선정함에 있어서 전문가 및 이해당사자들의 견해에 따른 평가 지역의 특성과 지속적인 변화 가능성 등을 유기적으로 연결될 수 있도록 평가요소로 반영할 수 있다. 본 연구는 추가 연구를 통해 남한강의 하도구간 별로 적용될 예정이며 각 인자들에 대한 자료는 문헌조사, 통계자료 조사 및 수리학적 수치모형 등의 분석을 통해 수집될 예정이다. 인자들에 대한 가중치는 전문가들의 의견을 반영할 예정이다. 향후 하천의 구간별 상대적 홍수취약도를 사회, 경제, 문화, 환경적인 측면을 고려한 인자들을 반영하여 정량적으로 제시하므로 하천 구간별 치수관리 우선순위를 결정하는데 적극적으로 활용될 수 있다.

  • PDF

Development of Valve Balance Test Equipment for Power Steering Gear (파워 스티어링 기어의 밸브 밸런스 테스트 장비 개발)

  • Go, S.J.;Park, M.K.;Won, T.H.;Kim, H.S.;Kim, K.H.
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.1
    • /
    • pp.65-71
    • /
    • 2011
  • Steering gear is the part of an automobile that change circular movement of steering wheel to lateral movement of rack to change driving direction. This can be classified with manual and power steering gear. Manual steering gear is operated only with human power while power steering gear use oil pressure support. These days power steering gear is more common to almost of the car. Recently a korean company manufactures a speed sensitive power steering which provide variable steering feel depend on the speed of car. The Broens company of Australia produces and exports the test equipments for the manufacture of power steering valves and assemblies to major vehicle manufactures. Some korean companies imported the test equipments from Australia, thus increasing the cost. The purpose of this study is development of the valve balance test equipment to measure the valve torque of the power steering gear. This study designed and manufactured the valve balance test equipment to take hold of the power steering valve using CAE analysis. In order to evaluate the performance of the developed valve balance test equipment, the R&R tests have been conducted.

Combustion Characteristics of a Gas Generator Associated with a Turbopump (터보펌프 연계상태의 가스발생기 연소 특성)

  • Seo, Seong-Hyeon;Ahn, Kyu-Bok;Han, Yeoung-Min;Choi, Hwan-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.133-136
    • /
    • 2008
  • The present study presents experimental results of combustion tests of a fuel-rich gas generator associated with a turbopump. Five combustion tests had been successfully executed. Static pressures of the gas generator promptly reacted to propellant supply variations from the turbopump. A closed-loop test for driving the turbopump revealed no flaw. Exit gas temperature results are very similar to previous ones. An orifice was effective on the suppression of pressure fluctuations although tests conducted below 45 bar showed the same dynamic behaviour as that of component-only tests.

  • PDF

Performance Comparison of Automotive Air conditioning System by using R134a and R152a (R134a와 R152a 냉매를 이용한 자동차용 에어컨 시스템의 성능 비교)

  • Kim, Jeong-Su;Nam, Su-Byung;Lee, Dae-Woong;Yoo, Seong-Yeon;Kim, Jin-Hyuck
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.9-14
    • /
    • 2006
  • This study presented the feasibility of R152a refrigerant as an alternative of R134a which is used in the current automobile air conditioning system. The performance of air conditioning system installed in the actual vehicle was tested using the climate wind tunnel. The experiments were conducted at various refrigerant charge quantities and various driving conditions such as city traffic, highway traffic and parking. Same components and lubricant were used for both R134a and R152a system. The effects of air set values of thermal expansion valve on the performance were also investigated. In case of the R152a system, refrigerant charge quantity can be reduced about 20%, better performance and superior compressor durability is expected due to the lower discharge pressure compared to the R134a system.

  • PDF