• Title/Summary/Keyword: Drinking water treatment

Search Result 736, Processing Time 0.025 seconds

A mini-review on microplastics in drinking water treatment processes (정수처리장 내의 미세플라스틱의 유입 및 처리기술 현황에 관한 고찰)

  • Choi, Byeonggyu;Kim, Jiyoon;Choi, Soohoon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.34 no.5
    • /
    • pp.357-371
    • /
    • 2020
  • Microplastics have become a rising issue in due to its detection in oceans, rivers, and tap water. Although a large number of studies have been conducted on the detection and quantification in various water bodies, the number of research conducted on the removal and treatment of microplastics are still comparatively low. In the current research, the inflow and removal of microplastics were investigated for various drinking water treatment plants around the world. Addition to the investigation of filed research, a survey was also conducted on the current research trend on microplastic removal for different treatment processes in the drinking water treatment plants. This includes the researches conducted on coagulation/flocculation, sedimentation, dissolved air flotation, sand filtration and disinfection processes. The survey indicated mechanisms of microplastic removal in each process followed by the removal characteristics under various conditions. Limitations of current researches were also mentioned, regarding the gap between the laboratory experimental conditions and field conditions of drinking water treatment plants. We hope that the current review will aid in the understanding of current research needs in the field of microplastic removal in drinking water treatment.

Effects of drinking water containing trimethyl glycine or ascorbic acid on growth performance and blood parameter in ducks under scorching heat wave (폭염 하에서 음수 내 비타민 C와 트리메칠글리신 공급이 오리의 혈액 매개변수 및 생산성에 미치는 효과)

  • Kang, H.K.;Park, B.S.
    • Journal of the Korean Applied Science and Technology
    • /
    • v.33 no.3
    • /
    • pp.411-420
    • /
    • 2016
  • The objective of this study was to determine the effect of drinking water containing trimethyl glycine or ascorbic acid on growth performance and blood parameter profiles of duck exposed to scorching heat stress. A total of 480 ducks were randomly assigned to the following eight experiment groups for 42 days : control group C with general water, treatment group 1 (T1) with drinking water containing 100 ppm ascorbic acid, treatment group 2 (T2) with drinking water containing 200 ppm ascorbic acid, treatment group 3 (T3) with drinking water containing 300 ppm ascorbic acid, treatment group 4 (T4) with drinking water containing 400 ppm trimethyl glycine, treatment group 5 (T5) with drinking water containing 800 ppm trimethyl glycine, treatment group 6 (T6) with drinking water containing 1,200 ppm trimethyl glycine, treatment group 7 (T7) with electrolytes of KCl (0.5%) + $NaHCO_3$ (1.0%)+NaCl (0.5%). Our results revealed that the body weights and feed intakes of treatment groups, especially T3 and T6, were increased compared to the control group, where as the feed conversion ratios of treatment groups were decreased (p<0.05). Blood levels of total cholesterol, triglyceride, LDL-C, glucose, AST, ALT and pH in treatment groups were lower compared to those in the control group (p<0.05). Blood levels of red blood cell, platelets profiles, electrolyte and gas in treatment groups were higher compared to those of the control group (p<0.05).

Present State of Membrane Filtration for Water Treatment in Japan

  • Kiso, Yoshiaki
    • Membrane Journal
    • /
    • v.13 no.1
    • /
    • pp.1-8
    • /
    • 2003
  • Membrane filtration systems have been focusing and increasing rapidly in the filed of drinking water treatment because of several reasons. We describe briefly the present state of membrane filtration processes for drinking water treatment in Japan: including background, objectives, membrane suppliers, and some cases of actual plants.

Recent Development of Drinking Water Quality Standard and its Application (음용수질 기준과 관리방안)

  • 권숙표
    • Journal of environmental and Sanitary engineering
    • /
    • v.7 no.2
    • /
    • pp.83-94
    • /
    • 1992
  • Recently water demand is increasing as the industry prospers. The increase of water demand is followed by the increase of wastewater discharge which pollutes rivers and ground water extensively. These rivers, reservoirs and ground water are sources for drinking water and their contamination affects the quality of water supply and other potable water. In Korea there are 776 water treatment plants which supply drinking water from main rivers or reservoirs. Rivers are the biggest water source for drinking water is being contaminated, the innovation of treatment process is needed. The construction and operation of water supply facilities is under the control of the Ministry of Construction and the water supply offices of cities and provinces. However, drinking water quality is under the control of the bureau of sanitation in the Ministry of Health and Social Affairs. There are 33 items in drinking water quality standards of Korea. Trihalomethanes, Selenium, Diazinone and other three of pesticides have been included lately, The Ministry of Health and Social Affairs is planning to enhance. the level of $VOC_S$(Vola-tile Organic Compounds) standard. Drinking water quality standard is the goal to protect the quality of supply water and ground water. In order to protect the source water from domestic or industrial water, technological improvement and adequate investment should be urgently made. The ultimate goal of drinking water quality is safety and health of consumers. The more stringent the standard are, the better the water quality will be. As the drinking water quality standards become more stringent this year, various and positive solutions by the authorities concerned must be prepared.

  • PDF

Introduction of Water Quality Certification System for Confidence Improvement of Tap Water (수돗물 신뢰도 향상을 위한 품질 인증 제도 도입)

  • Kim, Jinkeun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.29 no.2
    • /
    • pp.155-163
    • /
    • 2015
  • Many advanced treatment processes have been introduced to WTPs, however, the consumer confidence on tap water is still low and the percentage of drinking water directly from the tap is less than 2 %. One of the methods to improve the credibility of tap water is to introduce a drinking water certification system. By introducing the system, water treatment processes can be optimized, which in turn, can significantly improve drinking water quality. In this paper, 6 water quality parameters(i.e., turbidity, CT, residual chlorine, geosmin, 2-MIB, Mn) which have significant influences on tap water quality and consumer confidence were identified, and their recommended guidelines were proposed. 3-Star or 5-Star certification can be awarded to the WTPs which have met the certification criteria. The drinking water certification system can be carried out as a voluntary program among drinking water suppliers.

Zeolite Filtration for Ammonium Nitrogen Removal in Drinking Water Treatment (정수처리에서 암모니아성질소 제거를 위한 제올라이트 여과)

  • 김우항;김충환
    • Journal of Environmental Science International
    • /
    • v.12 no.3
    • /
    • pp.281-286
    • /
    • 2003
  • This study was conducted to evaluate the feasibility of ammonia removal by zeolite adsorption in drinking water treatment. In generally, drinking water treatment process is conducted coagulation/flocculation, sedimentation, sand filtration and disinfection. We tested feasibility with two method, one is powdered zeolite dosing to coagulation tank and the other is to substitute granular zeolite for sand of sand filter. In powdered zeolite test, raw water is used tap water with putting of 2 mg/l of NH$_4$$\^$+/-N. Filtration of granular zeolite was conducted with 80 cm of effective column high and 120 m/d of flow rate. At above 100 mg/1 of zeolite dosage, ammonia concentration was decreased below 0.5 mg/l of NH$_4$$\^$+/-N in powdered zeolite test. But, turbidity was increased to 30 NTU by powdered zeolite dosage. That turbidity was scarcely decreased in generally coagulant using condition in drinking water treatment. In granular zeolite test, ammonia was not detected in treated water until 8 days. This result suggest that using of granular zeolite in sand filter could be removal ammonia in winter. But we need regeneration at zeolite filtration for ammonia removal. So, it is to make clear that zeolite regeneration ability was compared KCl with NaCl. The result reveal that KCl was more excellent than NaCl. Optimum regeneration concentration of KCl was revealed 100 mM. Regeneration efficient was not increased at pH range 10∼12.5.

The Regulations and Guidelines for Management of Corrosive Water and Pipe Corrosion in Drinking Water Distribution System in North America (상수원 관망 부식 제어를 위한 부식성 수질 관리: 북미지역 관리 사례 및 국외 현황)

  • Kim, Minhee;Hyun, Seunghun;Lee, Won-Seok;Loretta, Y. Li
    • Journal of Korean Society on Water Environment
    • /
    • v.33 no.3
    • /
    • pp.359-369
    • /
    • 2017
  • Water distribution systems supply drinking water to consumers' taps. Internal corrosion of metallic pipe used in drinking water distribution systems has reduced water quality and led to increased levels of toxic heavy metals such as lead, copper and nickel. These problems have been experienced to varying degrees by water utilities in many countries. North America has successfully managed and controlled pipe corrosion and corrosive water in water distribution system based on various policies, regulations and rules. Practical and engineering guidelines for evaluation of pipe corrosion and determination of treatment options are also provided to assist drinking water supplies. In addition, the corrosion mechanism in water distribution systems, such as the complex effects of physical and chemical parameters on the corrosion pipes has been improved to accurately predict corrosion rates of metallic pipes in actual water distribution systems. This paper reviews various regulations, policy statement, and treatment produces on controlling corrosion in drinking water distribution systems in US and Canada and then offers suggestion for management of corrosive water and pipe corrosion in drinking water distribution system in Korea.

Management Plan for the Production of Safe and High Quality Drinking Water From the Paldang Lake (고 품질 수돗물 생산을 위한 팔당 수질관리 방안)

  • Cho, Deok-Hee;Kim, Jong-Soo;Lee, Woo-Sik
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.6
    • /
    • pp.665-672
    • /
    • 2008
  • It is necessary to implement the management plan for the production of safe and high quality drinking water from lake Paldang. To set up the plan, the water quality items such as BOD, T-P, SS and coliform were monitored for ten years, 1997~2006, and the influence of raw water quality on the drinking water treatment process and the treated water quality was also evaluated from 2004 to 2006. In conclusion, water quality items such as turbidity(SS), T-P(eutrophication), pathogens(fecal coliforms, enterovirus, reovirus, giardia, cryptosporidium), DOC(precursor of disinfection by-products), and micro-pollutants(phthalates, VOCs, heavy metals) are should be managed to get safe and high quality drinking water from lake Paldang.

A Study on the Management Criteria of Chemiclas Impurities for Drinking Water Treatment by Risk Assessment (건강위해성 평가에 의한 정수용 수처리제의 불순물 관리 기준 설정 방법에 관한 연구)

  • Chung, Yong;Beck, Young-seog;Kwon, Dong-sik;Lee, Ki-gong;Kang, Hyeong-seok
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.5
    • /
    • pp.432-436
    • /
    • 2004
  • The principle and methodology of risk assessment was applied to establish the quality standard of potential impurities of drinking water treatment chemicals. The impurities(arsenic, lead, cadmium, chromium, mercury, etc.) are regulated as the contained quantity of chemicals in Korea while they are regulated as the quality standard with the idea of 10% of the national safety drinking water standard in U.S.A(NSF) and Japan(JWWA). According to risk assessment of the current standard implemented in Korea, the excess cancer risk of arsenic and lead were determined in around $10^{-5}$ and the hazard quotient(HQ) of cadmium and chromium were below $10^{-2}$, respectively. And the standard concentration of the impurities are regulated as much as 2%~6% of the national drinking water quality standard. The values are more enforced rather than the standards in U.S.A(NSF) and Japan(JWWA) regulating the concentration of impurities the 10% of the national drinking water quality standard. We conclude that the impurities standard of drinking water treatment chemicals should be reconsidered comprehensively concerning the national safety drinking water quality standard and risk assessment.

The Synthesis of Polyamine Polymeric Flocculant and Application of Drinking Water Treatment. (Polyamine 고분자 응집제의 합성과 상수처리의 적용)

  • 신명철;최상준
    • Journal of Environmental Science International
    • /
    • v.7 no.3
    • /
    • pp.409-413
    • /
    • 1998
  • Polyamine was synthesized for the drinking water treatment. Polyamine was produced by the two step polycondensation of dimethytamine(DMA) and epichlorohydrin(EPI) and its properties were characterized. The effects of mole ratio of (DMA1/1EPl), reaction temperature and reaction time on synthesis of polyamine were investigated. Polyamine flocculant was applied to Nak-dong river raw water to examine its efficiency in reducing turbidity. The synthesized polyamine was effective as flocculant for drinking water treatment. The addition of 1 mg/L of polyamlne flocculant caused the reduction of 50% PAC (polyaluminium chloride).

  • PDF