• Title/Summary/Keyword: Drift Effects

Search Result 269, Processing Time 0.023 seconds

Steady Drift Forces on Very Large Offshore Structures Supported by Multiple Floating Bodies in Waves(I) (다수의 부체로 지지된 초대형 해양구조물에 작용하는 정상표류력(I))

  • H.J. Jo;J.S. Goo;S.Y. Hong;C.H. Lee
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.32 no.4
    • /
    • pp.123-135
    • /
    • 1995
  • A numerical procedure is described for predicting steady drift forces an multiple three-dimensional bodies of arbitrary shape freely floating in waves. The developed numerical approach is based on combination of a three-dimensional source distribution method, wave interaction theory art the far-field method using momentum theory. Numerical results are compared with the experimental or numerical ones, which are obtained in the literature, of steady drift forces on 33(3 by 11) floating composite vertical cylinders in waves. The results of comparison confirmed the validity of the proposed approach. Finally, the interaction effects are examined in the case of an array of 40(4 by 10) freely floating rectangular bodies in shallow water.

  • PDF

Effects of the earth fissure on the seismic response characteristics of a nearby metro station

  • Jiang Chang;Yahong Deng;Huandong Mu
    • Earthquakes and Structures
    • /
    • v.24 no.1
    • /
    • pp.53-64
    • /
    • 2023
  • Earth fissures with several kilometers will inevitably approach or cross the metro line, significantly threatening the safety of the underground structure in the earth fissure site. However, the influence of the earth fissure site's amplification effect on the metro station's dynamic response is still unclear. A representative earth fissure in Xi'an was taken as an example to establish a numerical model of a metro station in the earth fissure site. The dynamic response characteristics of the metro stations at different distances from the earth fissure under various seismic waves were calculated. The results show that the existence of the earth fissure significantly amplifies the dynamic response of the nearby underground structures. The responses of the axial force, shear force, bending moment, normal stress, horizontal displacement, inter-story drift, and relative slip of the metro station were all amplified within a specific influence range. The amplification effect increases with the seismic wave intensity. The amplification effect caused by the earth fissure has relatively weak impacts on the axial shear, shear force, bending movement, normal stress, and horizontal movement; slightly larger impacts on the inter-story drift and acceleration; and a significant impact on the relative slip. The influence ranges of the axial force and normal stress are approximately 20 m. The influence ranges of the acceleration and inter-story drift can reach 30 m. Therefore, the seismic fortification level of the underground structure in the earth fissure site needs to be improved.

Studies on Evaluation for Long-Term Structural Performance of Pinus densiflora Sieb. et Zucc. (I) -Shear Creep and Mechano-Sorptive Behavior of Drift Pin Jointed Lumber-

  • Hong, Soon-Il;Park, Jun-Chul
    • Journal of the Korean Wood Science and Technology
    • /
    • v.34 no.5
    • /
    • pp.11-18
    • /
    • 2006
  • This study was carried out to evaluate the mechano-sorptive deflection of shear creep of drift pin jointed solid wood. Specimens were the solid wood of Pinus densiflora. The joint was composed with steel plate and drift pin, 85mm in length and 10mm in diameter. The creep tests were conducted under the constant loads in an variable environment. Five different shearing loads were applied parallel to the grain of specimens. The shearing loads applied were 170, 340, 510, 680 and 850 kgf. The stress levels were 10, 20, and 30, 40 and 50% of the bearing strength obtained from the tension-type lateral strength test. The creep tests for specimens were carried out for 10300 hours. A few general conclusions could be drawn from this study: The mechano-sorptive deflection (${\delta}$ ms) is defined as ${\delta}\;ms={\delta}\;t-({\delta}\;c+{\delta}\;sh)-{\delta}\;o$, where ${\delta}$ t is the total deflection, ${\delta}$ c is the pure creep, ${\delta}$ sh is shrinkage-swelling behavior, and ${\delta}$ o is the initial deflection. Changes of relative humidity may cause more severe creep deflection than those of constant humidity, especially during the drying process. The mechano-sorptive behaviors of specimens, except the effects of shrinkage and swelling, gradually increased with increasing time. The deflection is increased in desorption process and recovered in adsorption process. The deflections of drift pin jointed solid wood under different loads showed almost same tendency in all specimens. Although the creep deflection tendencies of each series are very similar, the specimens subjected to a large shearing load exhibit large creep deflections in the desorption process than do those to the small shearing load specimens.

Non-Prismatic Beam Element for Beams with RBS Connection (RBS 연결부를 갖는 보에 대한 부등 단면 보 요소)

  • Kim, Kee Dong;Ko, Man Gi;Hwang, Byoung Kuk;Pae, Chang Kyu
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.6 s.73
    • /
    • pp.833-846
    • /
    • 2004
  • This study presents a non-prismatic beam element for modeling the elastic behavior of steel beams, which have the post-Northridge connections in steel moment frames. The elastic stiffness matrix, including the shear effects for non-prismatic members with reduced beam section (RBS) connection, is in closed form. A simplified approach is also suggested, which uses a prismatic beam element to model beams with the RBS connection. This method can estimate quiteexactly the maximum story drift ratios of frames with the RBS connection. The effects of reduced beam section connection on the elastic stiffness of steel moment frames were investigated. The selection of a proper model to account for deformations at the joint might have a more important role in estimating the maximum story drift ratios of frames with better accuracy than the RBS cutouts.

Study on Integrated for Capacitive Pressure Sensor (용량성 압력센서의 집적화에 관한 연구)

  • 이윤희
    • Journal of the Korean Institute of Telematics and Electronics T
    • /
    • v.35T no.1
    • /
    • pp.48-58
    • /
    • 1998
  • For the purpose of designing novel capacitance pressure sensor, several effects on sensitivity such as parasitic capacitance effects, temperature/thermal drift and leakage current have to be eleiminated. This paper proposed the experimental studies on frequency compensation method by electronic circuit technique, C-V converting method with switched capacitor and C-F converting method with schmitt trigger circuit. The third interface circuit by frequency compensation method is composed to eliminate the drift and leakage component by comparision sensing frequency with reference frequency. The signal transmission is realized by digital signal to minimize the influence of noise and high resolution is obtained by means of increasing the number of digital bits. In the fabricated high performance C-V interface, the offset voltage was not appeared, and in case of voltage source, 4.0V, feed back capacitance, 10㎊, the pressure, 0~10 ㎪, the sensitivity of C-V converter is 28 ㎷/㎪.V, the temperature drift characteristic, 0.051 %F.S./$^{\circ}C$ and C-F converter shows -6.6 Hz/pa, 0.078 %F.S./$^{\circ}C$ respectively, relatively good ones.

  • PDF

The Effects of Coupling Beam on Lateral Drift of High-rise Buildings (고층건물의 횡변위에 대한 커플링보의 효과)

  • Kim, Jin-Sang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.12
    • /
    • pp.5931-5937
    • /
    • 2011
  • The effects of coupling beam, which is generally used in high-rise building structure system as shear wall-coupling beam, on the lateral drift of high-rise buildings are studied in this paper. Six different analytical models, which are combination of two inputs, such as concrete strength and wall thickness, are selected and analyzed on lateral drifts with different stiffness of coupling beams. MIDAS GEN was used for analysis. Calculated lateral drifts were compared with allowable limits(H/400~H/500) proposed by standard CEN EC 3/1, in order to analyze the control evaluation of coupling beams. Calculated x-direction displacements were 68~87 percent of allowable limit(H/500). With increase of wall thickness(100mm) and concrete strength(5Mpa), eight to ten percent and four percent of x and y-direction displacement were decreased individually. About three percent of lateral displacement was increased with 20 percent decrease of coupling beam stiffness and additional 20 percent decrease resulted in additional five to eight percent increase.

Shearing Strength Properties of Bolted, Drift-Pinned Joints of the Larix Glulam - Effects of Fastener Diameter, Slenderness and End-distance on Strength Properties - (낙엽송 집성재의 Bolt, Drift Pin 접합부의 전단강도 성능 평가 - 접합구 직경, 세장비, 끝면거리가 강도에 미치는 영향 -)

  • Kim, Keon-Ho;Hong, Soon-Il
    • Journal of the Korean Wood Science and Technology
    • /
    • v.36 no.1
    • /
    • pp.69-78
    • /
    • 2008
  • Shearing strength test in tension type was investigated to determine the shear resistance of bolt and drift-pin connection of domestic larix glulam. The specimen was connected with bolt and drift-pin in the inserted plate type, and only bolt in the side plate type. The diameter of bolt and drift-pin used in the experiment are 12, 16 and 20 mm. The hole of bolt was drilled at the end-distance 5 d and 7 d. Tension load was loaded in the direction parallel to grain. The shear resistance was evaluated according to end-distance through this, the yield load was compared with the experimental yield load, using Larsen's formula. The prototype design strength is based on the yield load of end-distance 7 d and the reduction factor of end-distance 5 d was calculated. The results were as follows. 1. The average of maximum load of drift-pin connection was higher by 3~30% at the inserted type than at bolt connection with increasing diameter. In bolt connection, the average of maximum load of the side type was 1.54~2.07 times higher than that of the inserted type. In the same diameter, the average of maximum load of end-distance 7 d was higher by 8~44% than that of 5 d. 2. The bearing stress was 1.16~1.41 times higher at the inserted connection than at drift-pin connection, and 1.37~1.86 times higher at 7 d than at 5 d. Also, when the slenderness ratio was below 7.5 at drift-pin connection and below 6.0 at inserted connection, the lateral capacity was good. 3. The ratio of the experimental yield load and the predicted yield load calculated by Larsen's formula proposed by Larsen was 0.80~1.10 at inserted connection, and 0.75~1.46 at side connection. 4. When the inserted bolt connection was based on the yield load of end-distance 7 d, the reduction factor was 0.89 at 12 mm connection, 0.93 at 16 mm and 0.85 at 20 mm. The reduction factor was 0.89 at 12 mm the inserted drift-pin connection, 0.93 at 16 mm, 0.93 at 20 mm. The reduction factor was 0.79 at the side connection of the 12 mm bolt connection and 0.80 at 16 mm.

Vibration Control of a Structure Using the Toggle-Rotational Inertia Damper (토글-회전관성댐퍼를 이용한 구조물의 진동제어)

  • Hwang, Jae-Seung;Choi, Rak-Sun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.586-590
    • /
    • 2006
  • This paper presents a new vibration control device by which the mass and damping of a structure is increased equivalently. The vibration control system, named toggle-rotational inertia-viscous damper, can be utilized effectively in applications of small structural drift. Numerical analysis shows that because the relative drift of a structure can be effectively amplified by the toggle system, the device has a great performance in the vibration control without the increase of the damper capacity and size. It is also observed that vibration control effects is caused by the increase of equivalent mass and damping due to the rotational inertia and damping of the device.

  • PDF

Hysteretic Energy Characteristics of Steel Moment Frames Under Strength Variations

  • Choi, Byong Jeong;Kim, Duck Jae
    • Architectural research
    • /
    • v.2 no.1
    • /
    • pp.61-69
    • /
    • 2000
  • This research focused on the hysteretic energy performance of 12 steel moment-resisting frames, which were intentionally designed by three types of design philosophies, strength control design, strength and drift control design, and strong-column and weak-beam control design. The energy performances of three designs were discussed In view of strength increase effect, stiffness increase effect, and strong-column and weak-beam effects. The mean hysteretic energy of the 12 basic systems were statically processed and compared to that of single-degree-of-freedom systems. Hysteretic energy was not always increased with an increase of strength and stiffness in the steel moment-resisting frames. Hysteretic energy between strong-column and weak-beam design and drift control design with the same stiffness was not sensitive each other for these types of mid-rises of steel moment-resisting frames.

  • PDF

Pushover Tests of 1 : 5 Scale 3-Story Reinforced Concrete Frames (1 : 5 축소 3층 철근콘크리트 골조의 횡방향 가력실험)

  • 이한선;우성우;허윤섭;송진규
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.04a
    • /
    • pp.529-536
    • /
    • 1999
  • The objective of the research stated herein is to observe th elastic and inelastic behaviors and ultimate capacity of 1 : 5 scale 3-story reinforced concrete frame. Pushover tests were performed to 1:5 scale 3-story reinforced concrete frames without and with infilled masonry. To simulate the earthquake effect, the lateral force distribution was maintained to be an inverted triangle by using the whiffle tree. From the results of tests, the relations between the total lateral load and the roof drift, the distribution of column shears, the relation between story shear and story drift, and the angular rotations at the critical portions of structures were obtained. The effects of infilled masonry are investigated with regards to the stiffness, strength, and ductility of structures. Final collapse modes of structures with and without infilled masonry are compared.

  • PDF