• Title/Summary/Keyword: Drainage pipe

Search Result 168, Processing Time 0.023 seconds

Establishing Automated Mapping/Facilities Management System Using PC-CAD (PC용 CAD를 이용한 단지기반시설 정보화)

  • 이규석;안승만;탁형렬
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.15 no.2
    • /
    • pp.141-148
    • /
    • 1997
  • Continuous development of Personal Computer(PC) combined with the decrease of price and the expansion of operating system in PC like Windows 95, and Windows N/T makes it possible for the user to consider PC-bas-ed Automated Happing/Facilities Management (AM/FM) system. Therefore, the purpose of this study is to establish a PC-based data automation system of pipe infrastructures-water, sewer, and drainage-and road in Korea Land Corporation. In order to achieve this goal, relevant literature survey was done first. Secondly, the study site was determined by discussion with Korea Land Institute. Thirdly, PC-based CAD software for AM/FM in the world market were surveyed, and AutoCAD Map was selected because KLC had been using hundreds of AutoCAD copies already. After that user needs assessment was done to visit on-site office, local branch office, and the corresponding city office for the system design and database design. After the graphic data were digitized and the attribute data were entered into the batabase, the data automation system was established, and tested for application. Finally, the guidelines and problems for PC-based data automation in AM/FM was discussed.

  • PDF

Comparison of Optimization Techniques in Cost Design of Stormwater Drainage Systems (우수관망 시스템 설계에 있어서의 최적화기법의 비교)

  • Kim, Myoung-Su;Lee, Chang-Yong;Kim, Tae-Jin;Lee, Jung-Ho;Kim, Joong-Hoon
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.6 no.2 s.21
    • /
    • pp.51-60
    • /
    • 2006
  • The objective of this research is to develop a least cost system design method for branched storm sewer systems while satisfying all the design constraints using heuristic techniques such as genetic algorithm and harmony search. Two sewer system models have been developed in this study. The SEWERGA and SEWERHS both determine the optimal discrete pipe installation depths as decision variables. Two models also determine the optimal diameter of sewer pipes using the discrete installation depths of the pipes while satisfying the discharge and velocity requirement constraints at each pipe. Two models are applied to the example that was originally solved by Mays and Yen (1975) using their dynamic programming(DP). The optimal costs obtained from SEWERGA and SEWERHS are about 4% lower than that of the DP approach.

Study on the discharge of soil particles and ground collapse through cracks in underground structures (지중구조물 균열을 통한 토립자 유출 및 지반함몰 특성 연구)

  • Kim, Ho-Jong;Kim, Kang-Hyun;Shin, Jong-Ho
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.5
    • /
    • pp.699-715
    • /
    • 2019
  • Recently, in urban areas, cavities and ground collapse adjacent to underground structures are frequently reported. Several studies on the cavity generation by structure cracks have been made, however they are focused on the cause of cracks and settlement of the ground. In this paper, soil particle and groundwater discharge through pipe cracks and cavity generation mechanism are investigated. The theoretical analysis of the groundwater, which is the main factor of the drainage of the soil particles, and the particle transport mechanism and flow characteristics were investigated. An experimental model test was carried out to identify the mechanism of cavity generation by underground buried pipe cracks. The soil particle weight of discharge through the cracks, and the movement characteristics of the particles were analyzed using PIV. In this study, it is clearly identified that soil particle movements, cavity generation and ground collapse that occur in the ground are basically caused by the movement of groundwater.

Applicability of Huff Model & ABM Method for Discharge Capacity of Sewer Pipe (하수관거 통수능 해석을 위한 Huff 모형과 ABM 법의 적용성 분석)

  • Hyun, Inhwan;Jeon, SeungHui;Kim, Dooil
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.36 no.4
    • /
    • pp.229-237
    • /
    • 2022
  • The sewer capacity design have been based on the Huff model or the rational equation in South Korea and often failed to determine optimal capacity, resulting in frequent urban flooding or over-sizing. A time distribution of rainfall (i.e., Huff or ABM method) could be used instead of a rainfall hyetograph obtained from statistical analysis of previous rainfalls. In this study, the Huff method and the ABM method, which predict the time distribution of rain intensity, which are widely used to calculate sewage pipe drainage capacity using the SWMM, were compared with the standard rainfall intensity hyetograph of Seoul. If the rainfall duration was 30 minutes to 180 minutes, the rainfall intensity value calculated by the Huff model tended to be less than the rainfall intensity value of the standard rainfall intensity in the initial 5-10 minutes. As a result, more than 10% to 30% of under-design would be made. In addition, the rainfall intensity value calculated by the Huff model from the section excluding the initial 5-10 minutes of rainfall to the rainfall duration was calculated larger than the value using the standard rainfall intensity equation, which would result in an over-design of 10% to 30%. In the case of a relatively long rainfall duration of 360 minutes (6 hours) to 1,440 minutes (24 hours), it showed an lower rainfall intensity of 60 to 90% in the early stages of rainfall, but the problem of under-design had been solved as the rainfall duration time had elapsed. On the other hand, in the alternating block method (ABM) method, it was found that the rainfall intensity at the entire period at each assumed rainfall duration accurately matched the standard rainfall intensity hyetograph of Seoul.

An Overview of Geoenvironmental Implications of Mineral Deposits in Korea (한반도 광상 성인유형에 따른 환경 특성)

  • 최선규;박상준;이평구;김창성
    • Economic and Environmental Geology
    • /
    • v.37 no.1
    • /
    • pp.1-19
    • /
    • 2004
  • Metallic deposits in Korea have a variety of genetic types such as hydrothermal veins, skarns, hydrothermal replacement and alaskite deposits and so on. Geological, mineralogical and geochemical features including host rock, wall-rock alteration, ore and gangue mineralogy, mineral texture and secondary mineralogy related to weathering process control the environmental signatures of mining areas. The environmental signatures of metallic deposits closed from early 1970s to late 1990s in Korea show complicate geochemistry and mineralogy due to step weathering of primary and secondary minerals such as oxidation-precipitation-remobilization. The potentiality of low pH and high heavy metal Concentration s from acid mine drainage is great in base-metal deposits associated with polymetallic mineralization, breccia-pipe type and Cretaceous hydrothermal Au veins with the amount of pyrite whereas skam, hydrothermal replacement, hydrothermal Cu and Au-Ag vein deposits are in low contamination possibility. The geoenvironmental models reflecting the various geologic features closely relate to disuibution of sulfides and carbonates and their ratios and finally effect on characteristics of environmental signatures such as heavy metal species and their concentrations in acid mine drainage.

An experimental study on increased pressure in Shinwol rainwater storage and drainage system by undular bore (불규칙 단파에 의한 신월 빗물저류배수시설 내 압력상승에 관한 실험 연구)

  • Oh, Jun Oh;Park, Jae Hyeon;Jun, Sang Mi
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.4
    • /
    • pp.303-312
    • /
    • 2020
  • An underground deep tunnel system is a facility in form of a reverse siphon for an under flood defense structure. In this study, the 'Shinwol rainwater storage and drainage system', which is under construction for the first time in South Korea, in order to confirm the effects of undular bore and pressurized air on the hydraulic stability of the facility in various flood scenarios a hydraulic model experiment was performed. As a result of this study, it was analyzed that the undular bore generated downstream pushed the pressurized air collected in the facility while moving upstream, and the pressure inside the pipe increased at this time. It was analyzed that the pressure during the passage of the undular bore was greater than the sum of the static pressure and dynamic pressure at the time and overflow occurred when the cross-sectional size of the pressurized air was more than 40% of the cross sectional area of the tunnel. It is determined that this is correlated with the volume of pressurized air collected in the facility, and it is determined that it is necessary to study the relationship between velocity of undular bore and the volume of pressurized air in the future.

Characteristics of Environmental Contamination for the Groundwater and Stream Water in the Vicinity of the Woonjeongdong Sanitary Landfill Area in Kwangju-city, Korea (광주광역시 운정동 위생매립장 주변 지하수와 하천수의 환경지구화학적 오염특성)

  • 오근창;윤정환;김경웅;박천영;김정빈
    • Economic and Environmental Geology
    • /
    • v.34 no.6
    • /
    • pp.523-537
    • /
    • 2001
  • The physical properties of pH, turbidity, TDS and salt contents in the stream water near the entrance of Woonjcongdong sanitary landfill area with a drainage pipe are higher than those in neighbored drainage system, but DO it lower than that in neighbored drainage system blue to the eutrophication. In the ground water, pH, turbidity, TDS and salt contents at A ,F and C where may be under effect of the Woonjeongdong sanitary landfill area, are also shown higher values in contrast to other groundwater site, like B , D , and E , Particularly, the groundwater in A , F and C are plotted in Na-Cl type (If the piper diagram, which is an another important prolf of the contaminapion by the leachate and washing water from the Woonjeongdong sanitary landfill area. Some elements and physical properties of the waters in rainy season are desplayed a clear characteristics of contaminaton, compared to the theose of winter in thes study. Elements such as Ca, Mg, Na, K, Cl­,$SO_4^{2-} , \;and \;F­^-$) are accompanied well with each other by the result of water in the vicinity of landfillarea.

  • PDF

Development of flood inundation area GIS database for Samsung-1 drainage sector, Seoul, Korea (서울 삼성 1분구에 대한 침수면적 GIS 데이터베이스 구축)

  • Oh, Minkwan;Lee, Dongryul;Kwon, Hyunhan;Kim, Dongkyun
    • Journal of Korea Water Resources Association
    • /
    • v.49 no.12
    • /
    • pp.981-993
    • /
    • 2016
  • This study explains the GIS database of flood inundation area developed for Samsung-1 Drainage Sector, Seoul, Korea. The XP-SWMM dual drainage model was developed for the study area, and the time series observed at the watershed outlet was used to obtain the watershed time of concentration and to calibrate the XP-SWMM model. The rainfall scenario was developed by dividing the 40 minute watershed time of concentration into two 20-minute time steps and then applying the gradually increasing 5 mm/hr interval rainfall intensity to each of the time step up to 200 mm/hr, which is the probable maximum precipitation of the study area. The developed rainfall scenarios was used as the input of the XP-SWMM model to obtain the database of the flood inundation area. The analysis on the developed GIS database revealed that: (1) For the same increment of the rainfall, the increase of the flooded area can be different, and this was caused by topographic characteristics and spatial formation of pipe network of the study area; (2) For the same flooded area, the spatial extent can be significantly different depending on the temporal distribution of rainfall; and (3) For the same amount of the design rainfall, the flood inundation area and the extent can be significantly different depending on the temporal distribution of rainfall.

Evaluation of High-Resolution QPE data for Urban Runoff Analysis (고해상도 QPE 자료의 도시유출해석 적용성 평가)

  • Choi, Sumin;Yoon, Seongsim;Lee, Byongju;Choi, Youngjean
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.9
    • /
    • pp.719-728
    • /
    • 2015
  • In this study, urban runoff analyses were performed using high resolution Quantitative Precipitation Estimation (QPE), and variation of rainfall and runoff were analyzed to evaluate QPE data for urban runoff analysis. The five drainage districts (Seocho3, 4, 5, Yeoksam and Nonhyun) around Gangnam station were chosen as study area, the area is $7.4km^2$. Rainfall data from KMA AWS (34 stations), SKP AWS (156 stations) and Gwanduk radar were used for QPEs in Seoul area. Four types of QPE(QPE1: KMA AWS, QPE2: KMA+ SKP AWS, QPE3: Gwangduk radar, QPE4: QPE2+QPE3) of 6 events in July 2013 were generated by using Krigging and conditional merging. The temporal and spatial resolution of QPEs are 10 minutes and 250 m, respectively. The complex pipe network were treated as 773 manholes, 772 sub-drainage districts and 1,059 pipelines for urban runoff analysis as input data. QPE2 and QPE4 show spatial variation of rainfall by sub-drainage districts as 1.9 times bigger than QPE1. The peak runoff of QPE2 and QPE4 also show spatial variation as 6 times bigger than Gangnam and Seocho AWS. Thus, the spatial variation of rainfall and runoff could exist in small area such as this study area, and using high-resolution rainfall data is desirable for accurate urban runoff analysis.

Study on long-term monitoring of heat exchanger installed in the tunnel lining (터널 라이닝 내부에 설치한 열교환기의 현장모니터링 연구)

  • Lee, Chulho;Park, Moonseo;Choi, Hangseok;Sohn, Byunghu;Jeoung, Jaehyeung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.195.1-195.1
    • /
    • 2011
  • This paper presents an experimental study on a new potential geothermal energy source obtained from tunnel structures. An "energy textile", which is a textile-type ground heat exchanger, was fabricated between a shotcrete layer and a guided drainage geotextile in the tunnel lining system. To examine the long-term thermal behavior of the energy textile, the difference in temperatures of the inlet and outlet fluid circulating through the heat exchange pipe within the energy textile was monitored using a constant-temperature water bath. Daily heat exchange rate of the energy textile during cooling operation was estimated from the measured temperatures of the inlet and outlet fluid through the energy textile. The air and ground temperature was also continuously monitored. The operation of the energy textile as a ground heat exchanger was simulated using a 3D numerical CFD model (Fluent). The thermal conductivity of shotcrete and concrete lining components and temperature variation of air in the tunnel were incorporated in the model. The numerical analysis shows a good agreement with the long-term monitoring result.

  • PDF