• Title/Summary/Keyword: Drainage flow

Search Result 511, Processing Time 0.027 seconds

Estimation Error of Areal Average Rainfall and Its Effect on Runoff Computation (면적평균강우의 추정오차와 유출계산에 미치는 영향)

  • Yu, Cheol-Sang;Kim, Sang-Dan;Yun, Yong-Nam
    • Journal of Korea Water Resources Association
    • /
    • v.35 no.3
    • /
    • pp.307-319
    • /
    • 2002
  • This study used the WGR model to generate the rainfall input and the modified Clark method to estimate the runoff with the aim of investigating how the errors from the areal average rainfall propagates to runoff estimates. This was done for several cases of raingauge density and also by considering several storm directions. Summarizing the study results are as follows. (1) Rainfall and runoff errors decrease exponentially as the raingauge density increases. However, the error stagnates after a threshold density of raingauges. (2) Rainfall errors more affect to runoff estimates when the density of raingauges is relatively low. Generally, the ratio between estimation errors of rainfall and runoff volumes was found much less than one, which indicates that there is a smoothing effect of the basin. However, the ratio between estimation errors of rainfall to peak flow becomes greater than one to indicate the amplification of rainfall effect to peak flow. (3) For the study basin in this studs no significant effect of storm direction could be found. However, the runoff error becomes higher when the storm and drainage directions are identical. Also, the error was found higher for the peak flow than for the overall runoff hydrograph.

A study on the design of tunnel lining insulation based on measurement of temperature in tunnel (터널 온도계측을 통한 라이닝 단열 설계에 관한 연구)

  • Kim, Dea-Young;Lee, Hong-Sung;Sim, Bo-Kyoung
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.13 no.4
    • /
    • pp.319-345
    • /
    • 2011
  • In case of tunnels in cold regions, a freeze of groundwater around tunnel may act as a barrier of tunnel drainage in winter, or may cause the inner extrusion of lining. In spite of that, a design of insulation for preventing the frost damage of tunnel lining has not been introduced in Korea, while foreign countries such as Norway and so on have a standard on insulation. In this study, a few freezing cases of road tunnels have been reviewed, and the results show that the freezing protection is necessary. In order to characterize the thermal distribution in the tunnel, following measurements have been performed at Hwa-ak tunnel; the temperature distribution by longitudinal lengths, the internal temperature of lining and the temperature distribution of the ground under pavement. From these measurements, the characteristics of the tunnel's internal temperature distribution due to temperature change in the air has been analyzed. Based on the measurement results on the temperature distribution at Hwa-ak tunnel, thermal flow tests on the rock specimen with and without insulation have been performed in the artificial climate chamber to investigate the performance of the insulation. Also, a number of 3D numerical analyses have been performed to propose appropriate insulation and insulation thicknesses for different conditions, which could prevent the frost damage of tunnel lining. As a result of the numerical analysis, air freezing index of 291$^{\circ}C{\cdot}$ Hr has been suggested as the threshold value for freezing criteria of groundwater behind the tunnel lining.

Hydrologic Modeling for Agricultural Reservoir Watersheds Using the COMFARM (COMFARM을 이용한 농업용저수지 유역 수문 모델링)

  • Song, Jung-Hun;Park, Jihoon;Kim, Kyeung;Ryu, Jeong Hoon;Jun, Sang Min;Kim, Jin-Taek;Jang, Taeil;Song, Inhong;Kang, Moon Seong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.58 no.3
    • /
    • pp.71-80
    • /
    • 2016
  • The component-based modeling framework for agricultural water-resources management (COMFARM) is a user-friendly, highly interoperable, lightweight modeling framework that supports the development of watershed-specific domain components. The objective of this study was to evaluate the suitability of the COMFARM for the design and creation of a component-based modeling system of agricultural reservoir watersheds. A case study that focused on a particular modeling system was conducted on a watershed that includes the Daehwa and Dangwol serial irrigation reservoirs. The hydrologic modeling system for the study area was constructed with linkable components, including the modified Tank, an agricultural water supply and drainage model, and a reservoir water balance model. The model parameters were each calibrated for two years, based on observed reservoir water levels. The simulated results were in good agreement with the observed data. In addition, the applicability of the COMFARM was evaluated for regions where reservoir outflows, including not only spillway release but also return flow by irrigation water supply, substantially affect the downstream river discharge. The COMFARM could help to develop effective water-management measures by allowing the construction of a modeling system and evaluation of multiple operational scenarios customized for a specific watershed.

Atmospheric Characteristics of Fog Incidents at the Nakdong River : Case Study in Gangjeong-Goryeong Weir (낙동강 유역 안개 발생시 기상 특성: 강정고령보 사례를 중심으로)

  • Park, Jun Sang;Lim, Yun-Kyu;Kim, Kyu Rang;Cho, Changbum;Jang, Jun Yeong;Kang, Misun;Kim, Baek-Jo
    • Journal of Environmental Science International
    • /
    • v.24 no.5
    • /
    • pp.657-670
    • /
    • 2015
  • Visibility and Automatic Weather System(AWS) data near Nakdong river were analyzed to characterize fog formation during 2012-2013. The temperature was lower than its nearby city - Daegu, whereas the humidity was higher than the city. 157 fog events were observed in total during the 2 year period. About 65% of the events occurred in fall (September, October, and November) followed by winter, summer, and spring. 94 early morning fog events of longer than 30 minutes occurred when south westerly wind speed was lower than 2 m/s. During these events, the water temperature was highest followed by soil surface and air temperatures due to the advection of cold and humid air from nearby hill. The observed fog events were categorized using a fog-type classification algorithm, which used surface cooling, wind speed threshold, rate of change of air temperature and dew point temperature. As a result, frontal fog observed 6 times, radiation 4, advection 13, and evaporation 66. The evaporation fog in the study area lasted longer than other reports. It is due to the interactions of cold air drainage flow and warm surface in addition to the evaporation from the water surface. In particular, more than 60% of the evaporation fog events were accompanied with cold air flows over the wet and warm surface. Therefore, it is needed for the identification of the inland fog mechanism to evaluate the impacts of nearby topography and land cover as well as water body.

Mapping Inundation Areas by Flash Flood and Developing Rainfall Standards for Evacuation in Urban Settings (GIS를 이용한 도시지역 돌발홍수 침수예상지도 작성 및 대피강우기준 개발)

  • Shin, Sang-Young;Yeo, Chang-Geon;Baek, Chang-Hyun;Kim, Yoon-Jong
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.8 no.4
    • /
    • pp.71-80
    • /
    • 2005
  • As local flash flood exceeding planned capacity occurs frequently, localized preparedness and response to flood inundation are increasingly important. Using XP-SWMM model and GIS techniques, this study analyzes inundation areas by local flash flood and develops rainfall standards for evacuation with the case of Sadang-Cheon area, a local stream and its nearby highly populated watershed in the southern part of metropolitan Seoul, Flood inundation areas overflowed from drainage systems are analyzed and mapped by amount of rainfall that is derived from reference levels of stream flow. Rainfall standards for evacuation are comprised of 'watch' (40mm/hr) in preparing for near-future inundation and 'evacuation' (65mm/hr) in responding to realized inundation. The methods suggested by this case study may be applied to other urban areas for sound flood prevention policy measures and thus risk minimization.

  • PDF

Evaluation of the Numerical Liquefaction Model Behavior with Drainage Condition (배수조건에 따른 액상화 수치모델의 거동평가)

  • Lee, Jin-Sun;Kim, Seong-Nam;Kim, Dong-Soo
    • Journal of the Korean Geotechnical Society
    • /
    • v.35 no.11
    • /
    • pp.63-74
    • /
    • 2019
  • Numerical liquefaction model and response history analysis procedure are verified based on dynamic centrifuge test results. The test was a part of the Liquefaction Experiments Analysis Project (LEAP). The model ground was formed inside of rigid box by using the submerged Ottawa F65 sand with a relative density of 55% and 5° of surface inclination. A tapered sinusoidal wave with a frequency of 1 Hz was applied to the base of the model box. Numerical analyses were performed by two dimensional finite difference method in prototype scale. The soil is modeled to show hysteretic behavior before shear failure, and Mohr-Coulomb model is applied for shear failure criterion. Byrne's liquefaction model was applied to track the changes in pore pressure due to cyclic loading after static equilibrium. In order to find an appropriate flow condition for the liquefaction analysis, numerical analyses were performed both in drained and undrained condition. The numerical analyses performed under the undrained condition showed good agreement with the centrifuge test results.

Estimation of Rock Erodibility due to Energy Dissipation of Inflow Passing through the Sluice Gate of Seadike (배수갑문 유입수류의 에너지 감쇠에 따른 암석 침식 가능성 추정)

  • Jo, Jin-Hun;Park, Yeong-Jin;Park, Sang-Hyeon
    • Journal of Korea Water Resources Association
    • /
    • v.33 no.2
    • /
    • pp.237-245
    • /
    • 2000
  • Sihwa seadike is originally designed to control the water level In lake Sihwa. However the sluice gate is being operated everyday to preserve the water quality of lake. Due to the frequent operation of gates the bottom of drainage canal which is composed of weathered rock and soft rock is being scoured. Recently the bottom in the front area of apron was protected by putting underwater concrete. This study is carried out to understand the hydraulic situation for protection, and to estimate the trend of scouring by comparing between energy dissipation and registance of bottom rock. Annandale(1995) introduced the erodibility index theory, and suggested a criteria to judge the erodibility of rock through the relation between the erodibility index and energy dissipation. Determenation of erodibility index of rock is based on the results of sample core analysis, and the energy dissipation of flow is calculated from the estimation of total head on the scale model. These two values are plotted on the criteria, and the erodibility of rock is determined.

  • PDF

Optimal Parameters Estimation of Diffusion-Analogy Geomorphologic Instantaneous Unit Hydrograph Model (확산-유추 지형학적 순간단위도 모형의 최적매개변수 추정)

  • Kim, Joo-Cheol;Choi, Yong-Joon
    • Journal of Wetlands Research
    • /
    • v.13 no.3
    • /
    • pp.385-394
    • /
    • 2011
  • In this study, optimal parameters of diffusion-analogy GIUH were calculated by separating channel and hillslope from drainage structures in the basin. Parameters of the model were composed of channel and hillslope, each velocity($u_c$, $u_h$) and diffusion coefficient($D_c$, $D_h$). Tanbu subwatershed in Bocheong river basin as a target basin was classified as 4th rivers by Strahler's ordering scheme. The optimization technique was applied to the SCE-UA, the estimated optimal parameters are as follows. $u_c$ : 0.589 m/s, $u_h$ : 0.021 m/s, $D_c$ : $34.469m^2/s$, $D_h$ : $0.1333m^2/s$. As a verification for the estimated parameters, the error of average peak flow was about 11 % and the error of peaktime was 0.3 hr. By examining the variability of parameters, the channel diffusion coefficient didn't have significant effect on hydrological response function. by considering these results, the model is expected to be simplified in the future.

Identifying dominant parameters of storm-sewer-overflows in seperate sewer system (강우시 도시배수구역의 유출특성 지배인자 분석)

  • Jung, Si Mon;Park, In Hyeok;Ha, Sung Ryong
    • Journal of Wetlands Research
    • /
    • v.10 no.2
    • /
    • pp.105-114
    • /
    • 2008
  • Growth in population and urbanization has progressively increased the loadings of pollutants from non-point sources as well as point sources. Separated sewer overflows(SSO) have been considered as a major cause of water-quality deterioration of natural water-courses in the vicinity of the heavily urbanized areas. The factors defining the magnitude and occurrence of SSO are site-specific. It is important to know exact properties of pollutants contained in SSO to address water quality impacts that are caused by SSO inputs to the receiving waters. Site and event parameters found to have significant influences on urban runoff pollutant EMCs include total event rainfall, antecedent dry period, rainfall intensity. In this study, a field survey was carried out in some selected areas of Cheongju city. Literature from previous similar studies was consulted and some important factors affecting the runoff characteristics of urban drainage areas were analyzed for some selected survey points. It was found that the factors most affecting BOD are the number of dry days prior to rainfall and the intensity of the rainfall. The factor most affecting CODcr is the number of dry days prior to rainfall. The factors most affecting SS are the amount of rainfall and the number of dry days prior to rainfall. The factor most affecting TN is the amount of rainfall. The factor most affecting TP is the amount of rainfall and the number of dry days prior to rainfall.

  • PDF

A Simplified Design Method of Culvert Outlet for Detention Pond (저류지 방류암거의 간편설계기법)

  • Jang, Joo-Young;Lee, Jae-Joon
    • Journal of Korea Water Resources Association
    • /
    • v.44 no.4
    • /
    • pp.263-273
    • /
    • 2011
  • Recently increased rainfall by abnormal climate, risen peak runoff by urbanization, and shorten time of concentration are causing frequent overflow at downstream basin. This problem will be solved through the runoff reduction facilities like detention pond. However so far, most studies about detention pond in Korea are focused on its capacity. A study with respect to outlet facilities of detention pond was insignificant. Design of culvert usually used for outlet facilities of detention pond is generally carried out by using "Road Drainage Design" of Korea Expressway Corporation (1991). So detention pond is unreasonable to apply it. In this study, the culvert flow in submerged condition of upstream at culvert was analyzed., and simplified design procedure for culvert outlet facilities were presented for detention pond.