• Title/Summary/Keyword: Drainage capacity

Search Result 309, Processing Time 0.031 seconds

Infiltration and Drainage Capacity of Unsaturated Soil-Aggregate Foundation System (조립질 지반재료로 이루어진 기초의 불포화 침투 및 배수성능 평가)

  • Sung, Yeoul-Jung;Park, Seong-Wan;Tae, Doo-Hyung
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.966-972
    • /
    • 2009
  • Soil-aggregate system in pavement foundations exist in unsaturated conditions. However, change in water content on foundation layers due to joint and structural cracks during rainfall may cause problems like layer deformations or partial settlements. Therefore, a need exist to evaluate the infiltration and drainage capacity of soil-aggregate foundation system under both saturated and unsaturated conditions. To do that, a laboratory soil-water characteristic curve and permeability under unsaturated conditions are assessed to establish hydraulic properties of geomaterials and limited numerical analysis are performed respectively. As a result, it was found that suction profiles and drainage process was greatly influenced by the initial suction of soil-aggregate system at the time of infiltration, soil water characteristics curves, and hysteresis effects.

  • PDF

Estimation Process for the Capacity of Emergency Drainage System on a Ship after Flooding Accident (선박 침수사고를 대비한 비상용 배수시스템 용량추정 프로세스에 관한 연구)

  • PARK, Byung-Soo;KIM, Sung-Soo;LEE, Soon-Sup;KANG, Dong-Hoon;CHO, Hyun-Kuk
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.28 no.6
    • /
    • pp.1739-1750
    • /
    • 2016
  • This paper proposed a process for estimating the required capacity of emergency drainage system on a ship when the ship encounters a flooding accident. The process was established by selecting target vessel, making a scenario of flooding accident, considering static behavior of flooding water and the effect of ship motion due to ocean condition. In order to obtain the object of the research, MATLAB codes were developed for analyzing of static behavior of flooding water. Additionally, Ansys AQWA-NAUT was used to analyze the motion of the ship under an ocean condition and then the effect of ship motion was considered when the static behavior of flooding water was studied. The research exploited a trawler as a target vessel, and estimate the necessary capacity of the trawler's emergency drainage system by simulating a flooding water in the vessel.

Affecting Discharge of Flood Water in Paddy Field from Selecting Rainfall with Fixed and Unfixed Duration (고정, 임의시간 강우량 선택에 따른 농경지 배수 영향 분석)

  • Hwang, Dong Joo;Kim, Byoung Gyu;Shim, Jwa Keun
    • KCID journal
    • /
    • v.19 no.1
    • /
    • pp.64-76
    • /
    • 2012
  • Recently, it has been increased disaster of crops and agricultural facilities with climate change such as regional storm, typhoon. However agricultural facilities have unsafe design criteria of improving drainage corresponding to this change. This study has analyzed the impact that inundation area and magnitude of drainage-facility is decided based on fixed- and unfixed-duration precipitation by applying revised design criteria of drainage for climate change. The result was shown that 1-day and 2-days rainfall for 20-years return period has increased about 11.4%, 4.4% respectively by changing fixed- to unfixed duration. And the increase rate of design flood was 15.0%. The result was also shown that Inundation area was enlarged by 6.6% as well as increased inundation duration under same basic condition in designed rainfall between fixed- and unfixed-duration. According to the analysis, it is necessary for pump capacity in unfixed-duration to be increased by 70% for same effect with fixed-duration. Therefore, when computing method of probability precipitation is changed from fixed one to unfixed-duration by applying revised design criteria, there seems to be improving effect in drainage design. Because 1440-minutes rainfall for 20-years return period with unfixed-duration is more effective than 1-day rainfall for 30-years return period with fixed-duration. By applying unfixed-duration rainfall, capacity of drainage facilities need to be expanded to achieve the same effects (Inundation depth & duration) with fixed-duration rainfall. Further study is required for considering each condition of climate, topography and drainage by applying revised design criteria.

  • PDF

Evaluation of Solution Mediator in Irrigation System Controlled by Drainage Level Sensor (배액전극제어법 적용시 배액 이동매개체 선발)

  • Kim, Sung-Eun;Sim, Sang-Youn;Lee, Sang-Don;Kim, Young-Shik
    • Journal of agriculture & life science
    • /
    • v.44 no.6
    • /
    • pp.23-26
    • /
    • 2010
  • Commercial fibers such as two kinds of micro-fiber, flannel, and cotton were analyzed for their nutrient solution absorption capacity to select hydrophilic mat used for the irrigation management by drainage level sensor in perlite bag culture. The selected mat was evaluated in terms of absorption capacity. Cotton had the highest absorption capacity and was revealed to be the most appropriate for the control system.

A Study on Application of LID Technology for Improvement of Drainage Capacity of Sewer Network in Urban Watershed (도시 유역의 우수관망 통수능 개선을 위한 LID 기술 적용 연구)

  • Baek, Jongseok;Kim, Baekjoong;Lee, Sangjin;Kim, Hyungsan
    • Journal of Korean Society on Water Environment
    • /
    • v.33 no.6
    • /
    • pp.617-625
    • /
    • 2017
  • Both domestic and overseas urban drainage systems have been actively researched to solve the problems of urban flash floods and the flood damage that is caused by local downpours. Recent urban planning has been designed to better manage the floods of decentralized rainfall-management systems, and the installation of green infrastructure and low-impact development (LID) facilities at national ministries has been recommended. In this study, we use the EPA SWMM model to construct a decentralized rainfall-management network for each small watershed, and we analyze the effect of the drainage-capacity improvement from the installation of the LID technologies in vulnerable areas that replaces the network-expansion process. In the design of the existing urban piping systems, it is common to increase the pipe size due to the increment of the impervious area, the steep terrain, and the sensitive entrance-ramp junction; however, the installation of green infrastructure and LID facilities will be sufficient for the construction of a safe urban drainage system. The applications of LID facilities and green infrastructure in urban areas can positively affect the recovery of the corresponding water cycles to a healthy standard, and it is expected that further research will occur in the future.

An analysis of snow melting process for a study of defrosting phenomena (제상 현상 연구를 위한 눈 융해 과정 해석)

  • Lee, K.S;Ko, Y.W.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.1
    • /
    • pp.38-47
    • /
    • 1999
  • An improved one-dimensional modeling of snow melting was obtained by considering both the effect of heat capacity and the decreasing influence of porosity. Using the improved model, the effects of initial snow temperature, initial snow density and the heat flux on the snow melting were investigated. It is found that the drainage starting time is delayed and the drainage rate becomes smaller with lower initial snow temperature. ResuIts also show that the drainage starts at the same time when an initial snow density is over a certain value. Melting efficiency increases linearly with an increasing initial snow temperature. With increasing the initial density of the snow and the amount of heat supplied, the melting efficiency increases, then converges to a constant value.

  • PDF

Analysis of Urban Flood Damage Using SWMM5 and FLUMEN Model of Sadang Area in Korea

  • Li, Heng;Kim, Yeonsu;Lee, Seungsoo;Song, Miyeon;Jung, Kwansue
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.396-396
    • /
    • 2015
  • Frequent urban floods affect the human safety and economic properties due to a lack of the capacity of drainage system and the increased frequency of torrential rainfall. The drainage system has played an important role in flooding control, so it is necessary to establish the effective countermeasures considering the connection between drainage system and surface flow. To consider the connection, we selected SWMM5 model for analyzing transportation capacity of drainage system and FLUMEN model for calculating inundation depth and time variation of inundation area. First, Thiessen method is used to delineate the sub-catchments effectively base on drainage network data in SWMM5. Then, the output data of SWMM5, hydrograph of each manhole, were used to simulate FLUMEN to obtain inundation depth and time variation of inundation area. The proposed method is applied to Sadang area for the event occurred in $27^{th}$ of July, 2011. A total of 11 manholes, we could check the overflow from the manholes during that event as a result of the SWMM5 simulation. After that, FLUMEN was utilized to simulate overland flow using the overflow discharge to calculate inundation depth and area on ground surface. The simulated results showed reasonable agreements with observed data. Through the simulations, we confirmed that the main reason of the inundation was the insufficient transportation capacities of drainage system. Therefore cooperation of both models can be used for not only estimating inundation damages in urban areas but also for providing the theoretical supports of the urban network reconstruction. As a future works, it is recommended to decide optimized pipe diameters for efficient urban inundation simulations.

  • PDF

Relationship between Inundated Areas and Environmental Characteristics in Watershed for Natural Drainage Capacity Assessment in Urban Area (도시의 자연배수능력 평가를 위한 유역 내 환경특성과 침수피해면적의 관계)

  • Chung, Kyung-Jin;Kim, Min-Jung;Kim, Ok-Soo
    • 한국방재학회:학술대회논문집
    • /
    • 2007.02a
    • /
    • pp.211-214
    • /
    • 2007
  • The purpose of this study was to establish the basic information for natural drainage capacity assessment in urban area. We sorted midium watershed of Han river and Nak-dong river, and selected 30 rainfall events during 1995 to 2000 according to high level of damage. The inundated area showed high watershed slope about 25% and it indicated the greatest damage around the watershed located in 200-300m of altitude. Besides, the great damage by inundation was occurred in the mountainous agriculture region, where the forest scale was high and the urbanization was being progressed gradually. However, inundated area was small in case of grassland, water tone such as riparian area, bare ground and wetland. Moreover, the inundated area was different according to river shape and characteristics of river distribution such as the density of the stream order, conservation constant of the river system, and the number of undulations in the watershed. Therefore, it showed that land use, river shape and distribution characteristics of stream influence on inundation.

  • PDF

Evaluating Unsaturated Hydraulic Properties of Compacted Geomaterials in Road Foundations (II) : Numerical Analysis (다져진 도로기초 재료의 불포화투수특성 평가 (II) : 수치해석)

  • Sung, Yeol-Jung;Park, Seong-Wan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.1D
    • /
    • pp.83-90
    • /
    • 2011
  • A need still exists that the unsaturated condition is to be considered when evaluating the infiltration and drainage capacity for compacted geomaterials in road foundation or embankments. For this reason, numerical analysis were used to analyze the time-dependent unsaturated infiltration and drainage condition depending on various geomaterial types. Therefore, laboratory data from the soil-water characteristic curve tests on geomaterials were adopted from previous studies. In addition, the unsaturated permeability was estimated using SWCC. Then the infiltration and drainage performance of unsaturated compacted soils were evaluated under various conditions based on the proposed method. The results demonstrated that the effect of initial suction and SWCC path on each material could be substantial and the proper application on analysis is very important to enhance the prediction on each capacity.

Application of Stormwater Detention Facilities for Lacking Capacity of Sewers (강우시 도시 하수관거통수능부족 해소를 위한 우수저류시설의 적용)

  • Kim, Young-Ran;Kim, Jin-Young;Hwang, Sung-Hwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.3
    • /
    • pp.343-350
    • /
    • 2004
  • For the last two decades, Seoul has always been affected by large floods. As climate change causes more frequent localized heavy rains exceeding the capacity of sewer or river to discharge water, flood damage is expected to increase. Under the situation, detention facilities for lacking capacity of sewers can control stormwater runoff to reduce flood damage in urbanized areas. In this study, in order to reduce flood damage in Cheonggyecheon areas, the capacity of detention facilities was decided to make up for the lacking capacity of main sewers in case of the rainfall in July, 2001 as large flood. The average amount of stormwater detained in eight Cheonggyecheon drainage areas is $235.09m^3/ha$. Location and size of stormwater detention facilities is designed to have effects in short term by targeting the reduction of flood damage. Schools and parks are suggested as optimal locations where detention facilities are constructed in drainage areas.