• Title/Summary/Keyword: Drainage Gate

Search Result 41, Processing Time 0.034 seconds

Field Model Test of the Non-power Soil Cleaning System (무동력 토사제거시스템의 현장모형실험)

  • Park, Chan Keun;Lee, Young Hak;Hong, Seok Min;Lee, Dal Won
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.61 no.4
    • /
    • pp.63-73
    • /
    • 2019
  • Coastal and fishing facilities are gradually deteriorating in function due to the continual accumulation of soil sediments, which has affected local economic activities. Currently, there are many methods to remove soil sediments, but these methods are either a temporary solution or require a repetitive removal of the soil sediments, which is a huge financial burden for the maintenance of the facilities. To solve these problems, this study proposed a non-power soil cleaning system and evaluated field applicability by carrying out field model tests. The conditions for the evaluation focused on the drainage-elapsed time and drainage-outflow velocity according to the water level change in the water tank. In the field test, silty clay and sand were separately installed, and sedimentation soil removal test was practiced. As a result, the system was verified to have a sufficient outflow velocity for the removal of soil sediments. In addition, a generalization equation that can be used in different regions of the tide was suggested in this study. These results will greatly contribute to removing soil sediments in ports and dike gate facilities on the southwest coast. Since the system is an eco-friendly technology that does not require additional energy, thus it is expected to contribute to maintenance of sustainable facility performance as well as economic effect in the future.

A Technique of Inland Drainage Control Considering flood Characteristics of the Han River (한강홍수특성을 고려한 내배수 처리기법)

  • Lee, Won Hwan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.11 no.1
    • /
    • pp.99-108
    • /
    • 1991
  • Rapid changes of urban hydrologic events need new management operation rule of detention reservoir which is essential outflow control system in urban area. Therefore, this study is to develop the outflow management method of Seoul city considering the Han river flood characteristics, to analyze the inundation of detention reservoir according to variation of design storm patterns, and to examine the safety of gate due to design flood water level. From this study, new operation rule is presented. The design storm patterns are determined by instantaneous intensity method and Huff's quartile method. And the inflow hydrograph of detention reservoir is obtained by applying ILLUDAS model and RRL method. The operation rule of existing drainage pump is designed to have linear relation between storage and pumping discharge. But in this study, it is effective for preventing inundation when the operation rule of drainage pump have Gaussian function which is combined the storage of detention reservoir with its inflow according to increasing or decreasing of inflow hydrograph.

  • PDF

Estimation of Rock Erodibility due to Energy Dissipation of Inflow Passing through the Sluice Gate of Seadike (배수갑문 유입수류의 에너지 감쇠에 따른 암석 침식 가능성 추정)

  • Jo, Jin-Hun;Park, Yeong-Jin;Park, Sang-Hyeon
    • Journal of Korea Water Resources Association
    • /
    • v.33 no.2
    • /
    • pp.237-245
    • /
    • 2000
  • Sihwa seadike is originally designed to control the water level In lake Sihwa. However the sluice gate is being operated everyday to preserve the water quality of lake. Due to the frequent operation of gates the bottom of drainage canal which is composed of weathered rock and soft rock is being scoured. Recently the bottom in the front area of apron was protected by putting underwater concrete. This study is carried out to understand the hydraulic situation for protection, and to estimate the trend of scouring by comparing between energy dissipation and registance of bottom rock. Annandale(1995) introduced the erodibility index theory, and suggested a criteria to judge the erodibility of rock through the relation between the erodibility index and energy dissipation. Determenation of erodibility index of rock is based on the results of sample core analysis, and the energy dissipation of flow is calculated from the estimation of total head on the scale model. These two values are plotted on the criteria, and the erodibility of rock is determined.

  • PDF

Development of a Pump Operation Rule in a Drainage Pump Station using a Real Time Control Model for Urban Drainage System (내배수시스템 실시간 운영 모형을 이용한 배수펌프장 운영기법 개발)

  • Lee, Jung-Ho;Lee, Yang-Jae;Kim, Joong-Hoon;Jun, Hwan-Don
    • Journal of Korea Water Resources Association
    • /
    • v.40 no.11
    • /
    • pp.877-886
    • /
    • 2007
  • An urban drainage system consists of two major systems : flood drainage facilities and operating practices. The facilities are composed of sewer networks, gates, and pumping stations and the operating practice consists of pump or gate operation. Then, a real time simulation system which is able to simulate urban runoff and the pump operation and to consider the backwater effect is required to operate efficiently the pump. With this system, the efficient pump operating rule can be developed to diminish the possible flood damage on urban areas. In this study, a real time simulation system was developed using the SWMM 5.0 DLL and Visual Basic 6.0 equipped with EXCEL. Also, for developing efficient pump operating Rules, two new Rules were suggested. The first Rule is designed to operate pumps considering the condition of sewer networks such as depths of each junction. The second is to discharge all the amount of inflow at each time step. Results obtained by those Rules were compared with one by the current pump operating Rule which is able to consider only the depth of the retard basin. The developed model was applied to Joonggok retard basin and verified their applicability.

Evaluation for Determination of Optimum Size in Drainage Lock Gate (배수갑문 최적 규모 결정 검토)

  • Oh, Ji-Eun;Lee, Tae-Woo;Jung, Tae-Hwa;Lee, Jong-Seok
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2010.05a
    • /
    • pp.855-859
    • /
    • 2010
  • 우리나라는 국토면적이 작고 인구밀도가 높기 때문에 간척지를 조성해 농경지 및 대규모 공단으로 개발하여 사용하고 있다. 특히 서해안 지역은 조수간만의 차가 크지만 지형학적으로 간척지 개발의 적지가 많아 현재까지 방조제 설치가 가장 많이 이루어지고 있다. 그러나 방조제 설치 후, 호내 매립은 홍수위 및 홍수유출량의 급변으로 인해 외수위 변화에 따른 유출 배제 가능량을 재산정하여야 한다. 본 연구에서는 설계 홍수량, 시간별 외조위조건 그리고 유수지용량 등의 분석을 통하여 유역에서 홍수 발생 시 즉각적으로 대처할 수 있는 홍수배제용 배수갑문의 최적 규모를 결정하는 것이 목적이다.

  • PDF

A Study on the Composition Principle of the Gyeongbokgung Drainage Facility - Focused on the review of Gyeongbokgung excavation survey - (경복궁(景福宮) 배수시설(排水施設)의 조성원리(造成原理)에 관한 연구 - 경복궁 발굴조사 자료에 대한 검토를 중심으로 -)

  • Kim, Tae Min;Nam, Ho Hyun
    • Korean Journal of Heritage: History & Science
    • /
    • v.51 no.4
    • /
    • pp.120-145
    • /
    • 2018
  • This study intended to examine the drainage facility of Gyeongbokgung Palace based on the traces of the relic found during the excavation survey. Historical records indicate that various efforts have been made for smooth drainage facility for the palace since the foundation of the Joseon Dynasty. Although there are no drawings showing the image of early appearance of Gyeongbokgung Palace during the foundation, it is possible to estimate it through the drawings prepared after the King Yeongjo's reign. The image of the palace after reconstruction can be seen through the "Bukgwoldohyeong" and other relevant documents. At this present, since the survey intends to determine the image of Gyeongbokgung Palace during the reign of King Gojong based on the standard restoration plan of the Cultural Heritage Administration, this study also focused on the drainage facility of Gyeongbokgung Palace during King Gojong's reign, particularly on the collecting wells and culverts of six areas including "Chimjeon Hall", "Taewonjeon Hall", "Geoncheongung Hall", "Sojubang Hall", "Hamhwadang - Jipgyeongdang - Yeonghundang Hall", and "Heungbokjeon Hall". Gyeongbokgung Palace is divided into various zones composed of the central halls and surrounding corridors, and the drains also primarily start from each hall and later join the central drain of the zone. The central drain then leads to the "Eo-gu(御溝)" and the water led to the "Eo-gu" is finally discharged through the water gate. It appears that this series of processes were basically devised to coordinate artificial drain with the natural drain using the natural geographical features of the palace. Research showed that the collecting well where the draining begin was installed in the area where a large amount of household sewage was generated but mostly in the corners where corridors met or corridors and wall met. This appears to be an arrangement to handle the water falling from the roof and household sewage. Also, "Ju(廚)" was installed mainly at the end of the corridor to handle household sewage. The installation of these drainage facilities shows the possibility that the drainage of Gyeongbokgung was very compact under a series of plans.

Seepage Behaviors on the Box Culvert Side of Enlarged Levee (하천 보축제체의 배수통문 구조물 측면부 침투 특성)

  • Yang, Hakyoung;Kim, Youngmuk
    • Journal of the Korean GEO-environmental Society
    • /
    • v.21 no.4
    • /
    • pp.19-30
    • /
    • 2020
  • This numerical study is to investigate the seepage characteristics of the side of the structure in the event of leakage from the structural connection part of the drainage structure installed through the enlarged levee, and to analyze the effect of piping on the stabilization of the levee by the lateral penetration behavior. To take into account lateral seepage behavior, 2D and 3D numerical analyses were performed on the same model, and the effect of lateral seepage was analyzed to assess the validity of the numerical analysis. As a result, when leakage occurs and a lateral seepage is considered with the gate located on the riverside land, the maximum pore water pressure near the leakage point of the structure has been reduced by half compared to the normal seepage state where no leakage occurred. Excessive variation in the pore pressure was shown at the lower part of the structure, especially if lateral seepage is not considered. As a water level rises to the high water level, it shows the hydraulic gradient was larger than the critical hydraulic gradient, which will be vulnerable to long-term piping. If a gate is located in the inland and side seepage is not considered, the effect of the seepage water such as hydraulic gradient and seepage velocity is underestimated compared with the case of considering side seepage. The maximum hydraulic gradient is relatively small when lateral seepage is neglected if a gate is located in the riverside land and there was might be a risk of piping or loss of material. In addition, the period exceeding the critical hydraulic gradient was interpreted as a short time zone. As a result, it is considered that the possibility of piping can be underestimated if side seepage is ignored.

The Study of the Decision Criteria for the Urgency Released Valve in Hydraulic Dam (수력댐 비상방류밸브의 선정조건에 관한 연구)

  • Roh, H.W.;Lee, G.S.;Park, Y.M.;Kim, B.S.;Lee, Y.H.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.613-616
    • /
    • 2005
  • In general, the hollow jet valve, the fixed cone valve had been used for the urgency released or maintenance of the flow rate. Nowadays, the butterfly valve, the gate valve are applied in economic performance and operation maintenance more than the hollow jet valve, the fixed cone valve. However, in the case of butterfly valve, it should be required the strict application standard to the cavitation coefficient because the structural axis and disk were situated in pipe channel and the occurring the shock problem by Karman Vortex. And, the judgment data for choice were slight lowdown in water supply and drainage facilities standard or Japanese penstock technology standard, various standard of KOWACO etc. Therefore. there were investigated the valve inside phenomenon (cavitation, disk chattering, vibration) by velocity of flow and the stability examination of body by high velocity of flow through flow scale model test using the numerical analysis and PIV to establish the applicable extensibility of the butterfly valve for the urgency released valve.

  • PDF

Impact assessment of drainage gate operations on water resources in an estuarine reservoir (담수호의 배수갑문 운영에 따른 수자원 영향 분석)

  • Kim, Sinae;Kim, Seokhyeon;Lee, Hyunji;Kwak, Jihye;Jun, Sang-Min;Kang, Moon-Seong
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.165-165
    • /
    • 2022
  • 담수호는 하구에 방조제를 축조하여 인위적으로 조성된 저수지로, 배수갑문을 통해 적정수위를 유지하면서 이수 목적의 수자원으로 재활용할 경우 경제적이며 효율적인 수자원이 될 수 있다. 한편, 담수호는 유역의 최하류에 위치하므로 담수호의 통합적 수자원 관리를 위해서는 상류 유역 특성과 유입 오염물질 및 수체 특성에 대한 종합적인 이해를 바탕으로 수문, 수질, 염도 등 다양한수자원 요소를 고려하여 적절한 관리방안을 수립할 필요가 있다. 따라서 본 연구에서는 유역모형 및 호소모형을 연계하여 담수호의 내외 수위차를 고려한 배수갑문 운영 시나리오에 따른 호내 수문 및 수질 측면에서의 영향을 정량적으로 분석하였다. 충청남도 서산시에 위치한 간월호를 대상으로 HSPF (Hydrological Simulation Program-FORTRAN) 모형을 적용하여 상류유역의 장기유출량 및 수질 모의를 수행하여 호내 유입량 자료로 활용하였다. 호소 내 수리-수질 모의를 위해 3차원 수리해석 모형인 EFDC (Environmental Fluid Dynamics Code)와 호소수질모의 모형인 WASP (Water Quality Analysis Simulation Program)을 연계하여 배수갑문 운영에 따른 호내 수문 및 수질 변화를 모의하였다. 본 연구의 결과는 향후 수문 및 수질 영향을 고려한 담수호의 최적 수자원 관리방안 수립하는데 기초자료로 활용될 수 있을 것으로 기대된다.

  • PDF

Minimizing Nutrient Loading from SCB Treated Paddy Rice Fields through Water Management (SCB 액비 시용 논에서 물관리를 통한 양분의 수계 부하 최소화 방안)

  • Kim, Min-Kyeong;Kwon, Soon-Ik;Kang, Seong-Soo;Jung, Goo-Bok;Hong, Seung-Chang;Chae, Mi-Jin;So, Kyu-Ho
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.45 no.5
    • /
    • pp.671-675
    • /
    • 2012
  • This study was conducted to establish the BMPs (Best Management Practices) for preventing pollutant loadings from paddy rice field applied livestock liquid manure from 2008 through 2011. Cultivated paddy rice fields (Gyeonggi province, Korea) were treated with SCB (Slurry composting and bio-filtration process) liquid fertilizer. The BMPs for paddy rice field developed in this study includes: 1) the controlling a drainage water gate in paddy rice field from right after SCB liquid fertilizer application to 3 weeks after rice transplanting; 2) livestock liquid fertilizer application to paddy rice soils in 20 days before rice transplanting to encourage the utilization of liquid fertilizer; 3) preservation of surface water depth to 5 cm in a paddy field right after SCB liquid fertilizer applied to minimize a water pollution and enhance the utilization of liquid fertilizer; and 4) blocking a water gate at least for 2 days to inactivate E. coli survival. The findings of this study will provide useful and practical guideline to applicators of agricultural soil in deciding appropriate handling and time frames for preventing pollution of water quality for sustainable agriculture.