• Title/Summary/Keyword: Drag reduction rate

Search Result 58, Processing Time 0.018 seconds

Drag Reduction of Pipe Wall For Fluid Flow due to Injected Polymer Solution - II. Local Drag Reduction in Turbulent Flow- (고분자용액에 의한 유체수송관벽의 저항감소 -II. 난류흐름에서 국소저항감소-)

  • 추낙준;유경옥
    • Fire Science and Engineering
    • /
    • v.5 no.2
    • /
    • pp.11-20
    • /
    • 1991
  • Dilute polymer solutions were injected into turbulent pipe flow of a Newtonian fluid. The local drag reduction for injection of polymer solution at the pipe wall was larger than that at centerline. From the above result we may conclude that the polymer additives were found to influence the flow in the neighborhood of the wall. The effects of the injection apparatus on the local drag reduction are small compared to the drag-reducing effects. The extent of drag reduction increased with polymer concentration and injection flow rate, and the maximum drag reduction obtained were 47% for Polyox Coagulant and 35% for Separan AP-273. In respect to polymer degradation, the polyacrylamide showed better shear stability than the polyethyleneoxide and thus the former expected to have a sharper molecular weight distribution.

  • PDF

Experimental Study on Frictional Drag Reduction of Turbulent Flow by Polymer Solution Injection (폴리머 수용액 주입에 의한 난류마찰저항 감소에 대한 실험 연구)

  • 김형태;김덕수;김우전
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.40 no.3
    • /
    • pp.9-15
    • /
    • 2003
  • An experimental study has been carried out as a basic research for development of the friction drag reduction technology for ships by polymer injection. Experimental apparatus and procedures have been devised and prepared to measure the changes of the wall friction with injection of a polymer solution and basic experimental data on the friction drag reduction are obtained for a turbulent fiat-plate boundary layer and fully-developed channel flows. Variations of the friction drag reduction with some important parameters of polymer injection, such as the concentration of polymer solution, its injection flow rate and the measuring position downstream from the injection slot, are also investigated. Important experimental data and results obtained in the present study are presented. The amount of friction drag reduction up to 50% is observed.

Effect of Polymer Additives on Drag Reduction for a Plate Type Heat Exchanger in OTEC Applications (고분자 첨가제에 의한 OTEC용 판형 열교환기의 마찰저항감소 효과 연구)

  • Kim, N.S.;Yoon, S.M.;Seo, T.B.;Kim, C.B.
    • Solar Energy
    • /
    • v.19 no.2
    • /
    • pp.37-44
    • /
    • 1999
  • Experimental investigation has been carried out to determine drag reducing effects of polymer additives for a plate type heat exchanger(evaporator or condenser) in OTEC power plant applications, where the pressure drop in the heat exchangers takes up $70{\sim}80%$ of the total pumping power in the existing system. The rate of drag reduction was investigated with various polymer concentrations and mass flow rates. Experiments were undertaken for a test section in Alfa-Laval plate heat exchanger utilizing Poly Ethylene Oxide(Mw $5{\times}10^6$) as polymer additives. Concentrations of polymer additives were 5, 10, 20, 30, 40, 50, 100, 200, 400 wppm at $25^{\circ}C$ and mass flow rates were 0.6kg/s, 0.7kg/s, 0.8kg/s and 0.9kg/s in normal operating ranges for a 15kW Alfa-Laval plate heat exchanger. The maximum effects of drag reductions were found at approximately 0.7kg/s of mass flow rate. The results show that there exists the optimum mass flow rate for the plate heat exchanger to obtain maximum drag reductions. Drag reduction of 20% means considerable savings in pumping power for a large size of OTEC plant.

  • PDF

Drag Reduction on a Square Prism Using a Detached Splitter Plate (분리된 분할판에 의한 정방형주의 항력감소)

  • Ro, Ki-Deok;Yoon, Seong-Min;Choi, Dong-Hyeon;Kim, Jae-Hyeon;Sim, Eun-Chong
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2012.06a
    • /
    • pp.157-157
    • /
    • 2012
  • The Characteristics of the drag reduction of a square prism having a detached splitter plate at the wake side was investigated by measuring of fluid force on the square prism and by visualization of the field using PIV. The experimental parameters were the width ratios(H/B=0.5~1.5) of splitters to the prism width and the gap ratios (G/B=0~2) between the prism and the splitter plate. The drag reduction rate was increased with H/B, and was increased and decreased with G/B. The maximum drag reduction rate was represented by 24.2% at H/B=1.5 and G/B=0.5. The two vortices were generated by the splitter plate at the wake region of the prism. The direction of the vortex was clockwise at the upside of the splitter plate and counterclockwise at the downside.

  • PDF

A Study on Drag Reduction of Cylindrical Underwater Body Using Sintered Mesh (소결 메쉬를 이용한 원통형 수중운동체 항력 감소 연구)

  • Jung, Chulmin;Paik, Bugeun;Kim, Kyungyoul;Jung, Youngrae
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.21 no.2
    • /
    • pp.195-203
    • /
    • 2018
  • Among the techniques of reducing the drag to increase the speed of underwater moving bodies, we studied on the drag reduction method by gas injection. Researches on gas injection method have been paid much attention to reduce the drag of vessels or pipe inner walls. In this study, we used a sintered metal mesh that can uniformly distribute fine bubbles by gas injection method, and applied it to a cylindrical underwater moving body. Using the KRISO medium-sized cavitation tunnel, we measured both the bubble size on the surface of the sintered mesh and the bubble distribution in the boundary layer. Then, drag reduction tests were performed on the cylinder type underwater moving models with cylindrical or round type tail shape. Experiments were carried out based on the presence or absence of tail jet injection. In the experiments, we changed the gas injection amount using the sintered mesh gas injector, and changed flow rate accordingly. As a result of the test, we observed increased bubbles around the body and confirmed the drag reduction as air injection flow rate increased.

DNS of Drag-Reduced Turbulent Channel Flow due to Polymer Additives (폴리머 첨가제에 의한 항력감소 난류 채널 유동장의 직접수치모사)

  • Kim, Kyoung-Youn
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.8
    • /
    • pp.799-807
    • /
    • 2010
  • Direct numerical simulations (DNS) of turbulent channel flow for which the drag is reduced by using polymer additives have been performed by a pseudo-spectral method. The Reynolds number based on the friction velocity and half-channel height is 395, and the polymeric stresses due to the polymer additives are evaluated using the FENE-P (finitely extensible nonlinear elastic-Peterlin) model. The numerical results show that the drag reduction rate is significantly affected by the parameters used in the FENE-P model, such as the maximum extensibility and relaxation time of the polymer molecules. The turbulence data for both low- and high-drag reduction regimes are analyzed. In addition, the effects of FENE-P model parameters on the flow characteristics have been investigated for the same drag reduction rate due to the polymer additives. Finally, the present DNS results have been used to verify the correlation between rheological parameters and the extent of drag reduction, which was suggested by Li et al. (2006).

An Experimental Study on Friction Reduction by Additives in a Water Channel

  • Kim Wu-Joan;Kim Hyoung-Tae
    • Journal of Ship and Ocean Technology
    • /
    • v.9 no.1
    • /
    • pp.27-37
    • /
    • 2005
  • An experimental study has been carried out as a basic research for the development of the friction drag reduction technology for water-borne vehicles by injecting microbubbles or polymer solution. Experimental apparatus and procedures have been devised and prepared to measure the changes of the wall friction with the injection of additives and the basic experimental data on friction drag reduction are obtained for fully developed channel flows. The effects of key controlling parameters were investigated for higher drag reduction with varying the concentration and the injection rate of additives. The frictional drag has been reduced up to $25\%$ with the microbubble injection and $50\%$ with the polymer solution injection.

Long term drag reduction experiments of surfactant solutions in a pilot-scaled system (Pilot규모에서 계면활성제용액의 장기 마찰저항감소에 관한 연구)

  • Park, S.R.;Lee, S.N.;Moon, S.H.;Yoon, H.K.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.3
    • /
    • pp.401-409
    • /
    • 1997
  • The long term drag reduction characteristics of Habon-G solution were investigated in the KIER pilot-scaled district heating simulation system. Test runs were implemented for 30 days without interruption. Pressure drop, flow rate and power consumption of surfactant (Habon-G) solution were regularly observed and compared with those of plain water. The experimental results suggest that the surfactant can be effectively applied to the DH transmission system for considerably long period wthout significant loss of its drag reduction capability even though the concentration of the additive may gradually decrease in the first stage of the experiment because of absorption.

  • PDF

Pump and Temperature Effects on Drag Reducing Additives in Turbulent Pipe Flows (난류 관유동에서 마찰저항감소 첨가제에 대한 펌프와 온도의 영향)

  • Park, S.R.;Suh, H.S.;Yoon, H.K.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.3
    • /
    • pp.330-337
    • /
    • 1996
  • The effects of pump and temperature on drag reducing characteristics were investigated with a polymer(PAAM : Polyacrylamide) and three kinds of surfactants(CTAC, STAC, Habon-G) in fully developed turbulent pipe flows with various experimental parameters such as additive concentration(30~500ppm), pipe diameter(4.65mm, 10.85mm), Reynolds number($4{\times}10^4{\sim}10^5$) and working fluid temperature($20{\sim}80^{\circ}C$). The pump effect on PAAM was severe such that the drag reduction rates obtained with pump were decreased upto 30% as compared with those obtained with compressed air in 4.65mm test section. The temperature effect on PAAM was noticeably considerable, that is, the higher temperaute, the less drag reduction rate. On the other hand, no significant pump effect on the surfactants was observed. The drag reducing effectiveness of CTAC was totally lost in the temperature ragne of 60 to $80^{\circ}C$, whereas STAC and Habon-G kept their distinct drag reducing capability at a temperature of $80^{\circ}C$. This study clearly elucidated that for DHC application of drag reducing additives, the pump and temperature effects as well as additive concentration and pipe diameter should be carefully taken into consideration.

  • PDF

Drag Reduction on a Square Prism Using a Detached Splitter Plate (분리된 분할판에 의한 정방형주의 항력감소)

  • Ro, Ki-Deok;Yoon, Seong-Min;Choi, Dong-Hyeon;Kim, Jae-Hyeon;Sim, Eun-Chong
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.6
    • /
    • pp.808-813
    • /
    • 2012
  • The Characteristics of the drag reduction of a square prism having a detached splitter plate at the wake side were investigated by measuring of lift and drag on the square prism. The experimental parameters were the width ratios(H/B=0.5~1.5) of splitters to the prism width and the gap ratios (G/B=0~2) between the prism and the splitter plate. As the results the amplitude of the lift on the square prism having a detached splitter plate was remarkably decreased by comparison with the prototypical square prism. The drag reduction rate of the square prism was increased with H/B in case of the same G/B, and was increased and decreased with G/B in case of the same H/B. The maximum drag reduction rate was represented by 24.2% at H/B=1.5 and G/B=0.5.