• Title/Summary/Keyword: Down-sized computer

Search Result 12, Processing Time 0.024 seconds

Asan Medical Center Laboratory Information System (R) Information Communication System for Routine Hematology Using a Down-Sized Computer - (서울중앙병원 임상병리과 정보관리시스템(III))

  • 민원기;최윤미
    • Journal of Biomedical Engineering Research
    • /
    • v.15 no.3
    • /
    • pp.333-340
    • /
    • 1994
  • Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16 MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with two complete blood count analyzers (Sysmex WE-8000 and Coulter STKS) for unidirectional data transmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology.

  • PDF

심전계(ECG)의 제작설계

  • 서병설
    • Journal of Biomedical Engineering Research
    • /
    • v.9 no.2
    • /
    • pp.247-250
    • /
    • 1988
  • Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology.

  • PDF

A Study of the Effect of Medical Service Quality on Patient Satisfaction with a Focus on the Telemedicine Service of Colonoscopies

  • Lee, Jeong Sun;Lee, Min Jung
    • Journal of the Korea Society of Computer and Information
    • /
    • v.21 no.3
    • /
    • pp.47-56
    • /
    • 2016
  • Recently many small and mid-sized hospitals are closing down or experiencing financial difficulties. As a result, in order to provide exceptional service that would increase their competitiveness, they implemented telemedicine service for the prescription of medicine necessary before a colonoscopy. This study is an analysis of how telemedicine service affects patient satisfaction. Through the focus group interview (FGI) of medical service providers, regarding telemedicine service and face-to-face service, it was appraised that telemedicine service was more effective than face-to-face service. Afterward, a second survey aimed at endoscopy patients was conducted in order to find out the value of telemedicine service. First, through the analysis of the three main factors of telemedicine service, conclusions were drawn(safety/reliability, convenience/rapidity, and economics). A follow-up analysis showed that convenience/rapidity had the greatest effect on telemedicine service satisfaction. Next the factors of the quality of medical service were analyzed and 3 main factors were deduced (the superiority of the external and internal environments/appropriateness, superiority of the medical team, telemedicine service). A follow-up analysis found that telemedicine service had the greatest effect on patient satisfaction. This study found that providing exceptional medical service that utilizes telemedicine service would improve patient satisfaction. Therefore, we would be able to form a strategic plan that would strengthen the competitiveness of small and mid-sized hospitals.

Classification of TV Program Scenes Based on Audio Information

  • Lee, Kang-Kyu;Yoon, Won-Jung;Park, Kyu-Sik
    • The Journal of the Acoustical Society of Korea
    • /
    • v.23 no.3E
    • /
    • pp.91-97
    • /
    • 2004
  • In this paper, we propose a classification system of TV program scenes based on audio information. The system classifies the video scene into six categories of commercials, basketball games, football games, news reports, weather forecasts and music videos. Two type of audio feature set are extracted from each audio frame-timbral features and coefficient domain features which result in 58-dimensional feature vector. In order to reduce the computational complexity of the system, 58-dimensional feature set is further optimized to yield l0-dimensional features through Sequential Forward Selection (SFS) method. This down-sized feature set is finally used to train and classify the given TV program scenes using κ -NN, Gaussian pattern matching algorithm. The classification result of 91.6% reported here shows the promising performance of the video scene classification based on the audio information. Finally, the system stability problem corresponding to different query length is investigated.

천체 망원경의 자동화 : I. 컴퓨터 제어와 자동 관측을 위한 기본 설계 및 하드웨어의 제작

  • Gang, Yong-U;Lee, Hyeong-Mok;Yun, Gap-Su
    • Publications of The Korean Astronomical Society
    • /
    • v.6 no.1
    • /
    • pp.62-75
    • /
    • 1991
  • The small sized telescope can be best used if the control and observation can be made remotely and fully automatically by the aid of computers. We discuss the possible ways of automating the existing telescopes of various designs using personal computers. 'We have specifically designed the parts necessary to automate 16 inch Cassegrain Telescope at Pusan University Observatory. The degree of automation we have set for the present work is the interactive. remote observation including opening and shutting down of dome slit. The observational modes we have in mind are photoelectric photometry and CCD imaging. The basic components of the hardware are interface card for 16 or 32 bit IBM PC family of computers, relay switches for the control of telescope movements, stepping motor controller card for the control of observational equipments, and AID converter unit that accepts signal from sensors for the environment conditions such as temperature, wind speeds, precipitation, etc. We also have designed and built a photoelectric photometer that can be fully controlled by the command of a computer. Such observational equipment is also essential in order that the remote observation can be realized.

  • PDF

Development of Digital Signage System for Remote Video Advertisement in OSGi Service Platform (OSGi 서비스 플랫폼에서 원격 영상광고 송출 디지털 사이니지 시스템 개발)

  • Chung, Kyung Yong;Jeong, In Jae;Lee, Young Sil
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.20 no.4
    • /
    • pp.232-237
    • /
    • 2019
  • It has recently been combined with advanced technologies such as AR and VR, and its application range is expanding to various forms of smart signage. However, until now, digital signage service that reaches us is installed in many floating populations such as bus stops, elevators, and banks and is used in the form of providing news, weather, and advertisements. In addition, large companies, government offices, and outdoor advertising companies occupy the market. The use of such services in small and medium-sized businesses and small retail stores is costly and expensive to manage. Also, it is difficult to generalize the market because services and solutions are being deployed in the market in the form of top-down. Therefore, in this paper, we proposed a digital signage system for transmitting a remote video advertisement that uses a show window in front of the store as a beam project screen for small retail stores, and can remotely set and manage and update it in OSGi service platform.

A Study on Small-sized Index Structure and Fast Retrieval Method Using The RCB trio (RCB트라이를 이용한 빠른 검색과 소용량 색인 구조에 관한 연구)

  • Jung, Kyu-Cheol
    • Journal of the Korea Society of Computer and Information
    • /
    • v.12 no.4
    • /
    • pp.11-19
    • /
    • 2007
  • This paper proposes RCB(Reduced Compact Binary) tie to correct faults of both CB(Compact Binary) tie and HCB(Hierarchical Compact Binary) trie. First, in the case of CB trie, a compact structure was tried for the first time, but as the amount of data was increasing, that of inputted data gained and much difficulty was experienced in insertion due to the dummy nods used in balancing trees. On the other hand, if the HCB trie realized hierarchically, given certain depth to prevent the map from increasing on the right, reached the depth, the method for making new trees and connecting to them was used. Eventually, fast progress could be made in the inputting and searching speed, but this had a disadvantage of the storage space becoming bigger because of the use of dummy nods like CB trie and of many tree links. In the case of RCB trie in this thesis, the tree-map could be reduced by about 35% by completely cutting down dummy nods and the whole size by half, compared with the HCB trie.

  • PDF

Optimization of the growth of $CaF_2$ crystals by model experiments and numerical simulation

  • Molchanov, A.;Graebner, O.;Wehrhan, G.;Friedrich, J.;Mueller, G.
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.13 no.1
    • /
    • pp.15-18
    • /
    • 2003
  • High purity single crystalline calcium fluoride ($CaF_2$) has excellent optical transmission characteristics down to deep UV and is therefore selected as the main optical material for the next generation of lithography apparatus operating at wavelength of 157 nm. The growth of large sized $CaF_2$ single crystals with the required properties for this optical application can be achieved only by optimizing the crystal growth process by the aid of numerical simulation. This needs especially a precise calculation of the heat transport and temperature distribution in the solid and liquid $CaF_2$ under crystal growth conditions. As $CaF_2$ is considered to be semitransparent, the internal radiative heat transfer in $CaF_2$ plays an decisive role in the simulation of the heat transport. On the other hand it is very difficult to obtain quantitative experimental data for evaluating numerical models as $CaF_2$ is extremely corrosive at high temperatures. In this work we present a newly developed experimental technique to perform temperature measurements in $CaF_2$-crystal as well as in the melt under conditions of crystal growth process. These experimental results are compared to calculated temperature data, which were obtained by using different numerical models concerning the internal heat transfer in semitransparent $CaF_2$. It will be shown, that an advanced model, which was developed by the authors, gives a much better agreement with experimental data as a standard model, which was taken from the literature.

Strategies for Driving and Egress for the Vehicle of a Humanoid Robot in the DRC Finals 2015 (DRC Finals 2015 에서 휴머노이드 로봇의 자동차 운전과 하차에 관한 전략)

  • Ahn, DongHyun;Shin, JuSeong;Jun, Youngbum;Sohn, Kiwon;Jang, Giho;Oh, Paul;Cho, Baek-Kyu
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.22 no.11
    • /
    • pp.912-918
    • /
    • 2016
  • This paper presents various strategies for humanoid vehicle driving and egress tasks. For driving, a tele-operating system that controls a robot based on a human operator's commands is built. In addition, an autonomous assistant module is developed for the operator. Normal position control can result in severe damage to robots when they egress from vehicles. To prevent this problem, another approach that mixes various joint control techniques is adopted in this study. Additionally, a footplate is newly designed and attached to the vehicle floor for the ground landing phase of the egress task. The attached plate enables the robot to step down onto the ground in a safe manner. For stable locomotion, a balance controller is designed for the humanoid. For the design of the controller, the robot is modeled using an inverted pendulum that consists of a spring and a damper. Then, a state feedback controller (with pole placement and a state observer) is built based on the simplified model. Many approaches that are presented in this paper were successfully applied to a full-sized humanoid, DRC-HUBO+, in the DARPA Robotics Challenge Finals, which were held in the United States in 2015.

APICAL FITNESS OF NON-STANDARDIZED GUTTA-PERCHA CONES IN SIMULATED ROOT CANALS PREPARED WITH ROTARY ROOT CANAL INSTRUMENTS (전동화일로 형성된 근관에서 비표준화 Gutta-percha Cone의 적합성)

  • Kwon, O-Sang;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.3
    • /
    • pp.390-398
    • /
    • 2000
  • The purpose of this study was to evaluate the apical fitness of non-standardized gutta-percha cones in root canals prepared with rotary Ni-Ti root canal instruments of various tapers and apical tip sizes. Simulated sixty curved root canals of plastic blocks were prepared with crown-down technique using rotary root canal instruments of Maillefer ProFile$^{(R)}$ .04 and .06 taper (Maillefer Instrument SA, Switzerland). Specimens were divided into six groups and prepared as follows: Group 1, prepared up to size 25 of .04 taper ; Group 2, prepared up to size 30 of .04 taper ; Group 3, prepared up to size 35 of .04 taper ; Group 4, prepared up to size 25 of .06 taper ; Group 5, prepared up to size 30 of .06 taper ; Group 6 ; prepared up to size 35 of .06 taper. After cutting off the coronal portion of plastic, blocks perpendicular to the long axis of the canal with the use of a diamond saw, apical 5mm of canal space was analyzed. Prepared apical canal spaces were duplicated using rubber base impression material to evaluate two dimensional total area of apical canal space. Various sized gutta-percha cones were applied in the 5mm-apical canal space, which were size 25, size 30 and size 35 standardized gutta-percha cone, Diadent Dia-Pro ISO-.04$^{TM}$ and .06$^{TM}$(Diadent, Korea), and medium-fine (MF), fine (F), fine-medium (FM) and medium (M) sized non-standardized gutta-percha cones (Diadent, Korea). Coronal excess gutta-percha were cut off with a sharp blade. Photographs of impressed apical canal spaces and gutta-percha cones were taken with a CCD camera under a stereomicroscope and stored in a computer. Areas of the total canal space and gutta-percha cones were calculated using a digitalized image analysing program, CompuScope (Sungjin Multimedia Co., Korea). Ratio of apical fitness was obtained by calculating the area of gutta-percha cone to the total area of the canal space. The data were analysed statistically using One-way Analysis of Variance and Duncan's Multiple Range Test. The results were as follows: 1. In canals prepared up to size 25 ProFile$^{(R)}$ of .04 taper, non-standardized MF and F cones occupied significantly more canal space than Dia-Pro ISO-.04$^{TM}$ or size 25 standardized ones (p<0.05). 2. In canals prepared up to size 30 ProFile$^{(R)}$ of .04 taper, non-standardized F cones occupied significantly more canal space than Dia-Pro ISO-.04$^{TM}$ or size 30 standardized ones (p<0.05), and non-standardized MF cones occupied more canal space than size 30 standardized ones (p<0.05). 3. In canals prepared up to size 35 ProFile$^{(R)}$ of .04 taper, there was no significant difference in canal space occupation among non-standardized MF and F, size 35 standardized, and Dia-Pro ISO-.04$^{TM}$ cones (p>0.05). 4. In canals prepared up to size 25 ProFile$^{(R)}$ of .06 taper, non-standardized MF and F cones occupied significantly more canal space than Dia-Pro ISO-.06$^{TM}$, or size 25 standardized ones (p<0.05), and Dia-Pro ISO-.06$^{TM}$, cones occupied significantly more space than size 25 standardized ones (p<0.05). 5. In canals prepared up to size 30 ProFile$^{(R)}$ of .06 taper, non-standardized FM cones occupied significantly more canal space than Dia-Pro ISO-.06$^{TM}$ or size 30 standardized ones (p<0.05), and non-standardized F cones occupied significantly more canal space than size 30 standardized ones (p<0.05). 6. In canals prepared up to size 35 ProFile$^{(R)}$ of .06 taper, non-standardized M and FM, Dia-Pro ISO-.06$^{TM}$ occupied significantly more canal space than size 35 standardized ones (p<0.05). In summary, in both canals prepared with .04 or .06 taper ProFile$^{(R)}$, non-standardized cones showed better fitness than Dia-Pro ISO$^{TM}$ or standardized ones, which was more characteristic in smaller canals.

  • PDF